Gerson Henrique dos Santos
Research Subjects
Gerson Henrique dos Santos has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Eduardo Melo Lima
Federal University of Technology - Parana
3 shared publications - Douglas Pereira Vasconcellos
Pontifícia Universidade Católica do Paraná Curitiba Engenharia Mecânica
2 shared publications - Rhayssa Maryell Marra Ribas
Universidade Tecnológica Federal do Paraná, Brasil
2 shared publications - Roberto Zanetti Freire
Department of Electrical Engineering - DAELT-CT, Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba, Brazil
2 shared publications - Thiago Antonini Alves
UTFPR
2 shared publications - Victor Vaurek Dimbarre
Graduate Program in Mechanical Engineering (PPGEM), Federal University of Technology—Parana (UTFPR), Rua Doutor Washington Subtil Chueire, 330, Ponta Grossa 84017-220, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2025 (1)
Behavior of Salt Transport in Concrete Structures Under Temperature and Moisture Gradients
Concrete is one of the materials most widely used in building construction. The deterioration of foundations and load‐bearing structures can cause economic and environmental damage to such building types. Concrete degradation can occur in several ways due to mechanical stresses, climatic changes, and chemical attacks, such as the migration of salts into concrete pores. This last process can concentrate the salt in some points, which crystallizes, increasing the internal pressure and causing fissures and cracks, making the whole structure susceptible to other agents of deterioration. In this context, this work is aimed at numerically analyzing the effect of the coupled heat and moisture transport on the salt migration in concrete. The governing equations were initially modeled and discretized using the finite volume method. The multi‐tridiagonal matrix algorithm (MTDMA) was used to solve the system of algebraic equations, which allows the simultaneous solution of the governing equations. A comparison with other work found in the literature has been performed to verify the present model. A recognized agreement between the findings of the present model and those documented in the existing literature is noticeable, with recorded root mean square deviation values of 2.94% for 3 months (minimal) and 6.63% for the 12 months (maximum), both in this verification analysis duration. After this, simulations were performed to analyze the influence of temperature and moisture gradients on salt transport in a concrete sample. The results showed the effects of the imbibition and drying process in salt transport and the importance of the energy conservation equation present in this model despite the literature frequently considering isothermal conditions. These conclusions can be valuable in providing knowledge to prevent the deterioration of concrete structures. Furthermore, the salts’ analysis results illustrate sodium chloride’s capacity to undergo crystallization. Following a year of simulation, the sodium chloride attained a solubility level that was nearly uniform throughout the sample, in contrast to the concentration of magnesium sulfate.
- 1 January 2025
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2025 (1)
Open AccessBehavior of Salt Transport in Concrete Structures Under Temperature and Moisture Gradients
Concrete is one of the materials most widely used in building construction. The deterioration of foundations and load‐bearing structures can cause economic and environmental damage to such building types. Concrete degradation can occur in several ways due to mechanical stresses, climatic changes, and chemical attacks, such as the migration of salts into concrete pores. This last process can concentrate the salt in some points, which crystallizes, increasing the internal pressure and causing fissures and cracks, making the whole structure susceptible to other agents of deterioration. In this context, this work is aimed at numerically analyzing the effect of the coupled heat and moisture transport on the salt migration in concrete. The governing equations were initially modeled and discretized using the finite volume method. The multi‐tridiagonal matrix algorithm (MTDMA) was used to solve the system of algebraic equations, which allows the simultaneous solution of the governing equations. A comparison with other work found in the literature has been performed to verify the present model. A recognized agreement between the findings of the present model and those documented in the existing literature is noticeable, with recorded root mean square deviation values of 2.94% for 3 months (minimal) and 6.63% for the 12 months (maximum), both in this verification analysis duration. After this, simulations were performed to analyze the influence of temperature and moisture gradients on salt transport in a concrete sample. The results showed the effects of the imbibition and drying process in salt transport and the importance of the energy conservation equation present in this model despite the literature frequently considering isothermal conditions. These conclusions can be valuable in providing knowledge to prevent the deterioration of concrete structures. Furthermore, the salts’ analysis results illustrate sodium chloride’s capacity to undergo crystallization. Following a year of simulation, the sodium chloride attained a solubility level that was nearly uniform throughout the sample, in contrast to the concentration of magnesium sulfate.
- Open Access
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Effects of Soil Hygrothermal Properties on the Performance of an Earth-Air Heat Exchanger
Buildings are responsible for a large part of energy demand worldwide. To collaborate to reduce this demand, the use of passive air conditioning has proven to be beneficial for energy savings. In order to improve thermal comfort in built environments, Earth-Air Heat Exchangers (EAHE) can be installed as a low-cost option. Using low energy consumption, in this system, the ambient air circulates through a pipe buried at a certain depth in the ground, causing it to heat up or cool down, depending on weather conditions. These effects are possible due to the high thermal inertia of the soil. In this context, the climatization performance of EAHE depends directly on the hygrothermal properties of the soil, and the effects of heat, moisture, and air transport on the operation of an EAHE are barely explored in the literature due to many difficulties, such as modeling complexity, computer run time, numerical convergence and highly moisture-dependent properties. Therefore, to analyze the effects of hygrothermal properties of soil, a 2D model has been developed to calculate the coupled heat, air, and moisture transfer. The linearized set of discretized governing equations was obtained using the finite-volume method and solved via the MultiTriDiagonal-Matrix Algorithm, substantially improving the numerical stability and reducing the computer run time. To validate the temperature distribution along EAHE, a prototype was built on the Federal University of Technology of Paraná (UTFPR) - Campus Ponta Grossa, which includes 100 mm diameter Polyvinyl Chloride (PVC) ducts, a fan for airflow control, where a series of k-type thermocouples were inserted along the EAHE. Data were recorded hourly using a data acquisition system during the summer period.
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Open AccessEffects of Soil Hygrothermal Properties on the Performance of an Earth-Air Heat Exchanger
Buildings are responsible for a large part of energy demand worldwide. To collaborate to reduce this demand, the use of passive air conditioning has proven to be beneficial for energy savings. In order to improve thermal comfort in built environments, Earth-Air Heat Exchangers (EAHE) can be installed as a low-cost option. Using low energy consumption, in this system, the ambient air circulates through a pipe buried at a certain depth in the ground, causing it to heat up or cool down, depending on weather conditions. These effects are possible due to the high thermal inertia of the soil. In this context, the climatization performance of EAHE depends directly on the hygrothermal properties of the soil, and the effects of heat, moisture, and air transport on the operation of an EAHE are barely explored in the literature due to many difficulties, such as modeling complexity, computer run time, numerical convergence and highly moisture-dependent properties. Therefore, to analyze the effects of hygrothermal properties of soil, a 2D model has been developed to calculate the coupled heat, air, and moisture transfer. The linearized set of discretized governing equations was obtained using the finite-volume method and solved via the MultiTriDiagonal-Matrix Algorithm, substantially improving the numerical stability and reducing the computer run time. To validate the temperature distribution along EAHE, a prototype was built on the Federal University of Technology of Paraná (UTFPR) - Campus Ponta Grossa, which includes 100 mm diameter Polyvinyl Chloride (PVC) ducts, a fan for airflow control, where a series of k-type thermocouples were inserted along the EAHE. Data were recorded hourly using a data acquisition system during the summer period.
- Open Access
- 5 July 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1113
Numerical and Experimental Analysis of an Earth–Air Heat Exchanger
Buildings are responsible for a large part of energy demand worldwide. To collaborate to reduce this demand, this paper aims to present a computational model to analyze the performance of an earth–air heat exchanger (EAHE) based on computational fluid dynamics using the ANSYS/Fluent® software in the simulations. This passive air conditioning system uses the soil as a heat exchanger, taking advantage of the fact that the temperature of the soil at a certain depth remains relatively constant, regardless of the weather conditions above the surface, promoting heating, cooling, or ventilation for buildings. The air temperature values obtained were compared with experimental data from sensors installed in an EAHE at the Federal University of Technology—Parana, Ponta Grossa/Brazil (25.1° South, 50.16° West) to validate the computational model. A high computational effort would be demanded to perform these simulations involving the whole soil domain and the climatic boundary conditions. In order to optimize the numerical analysis of EAHE, two reduced models for the soil and heat exchanger domains were verified. First, a constant temperature of 23.7 °C was imposed on the surface of the exchanger tube, corresponding to the average soil temperature at a depth of 1.5 m. Afterward, a reduced soil domain extending 0.5 m in all directions from the heat exchanger serpentine was considered. Likewise, constant temperatures were imposed on the upper and lower surfaces of the soil domain, also obtained experimentally. In both cases, the temperature values obtained through the fast simulations showed good agreement compared to the experimental values. Barely explored in the literature, the thermal behavior of the two identical indoor environments at the university was also compared, in which the climatized environment, with the EAHE working in a closed loop, obtained milder and smaller amplitude air temperatures.
- 5 July 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1113
Open AccessNumerical and Experimental Analysis of an Earth–Air Heat Exchanger
Buildings are responsible for a large part of energy demand worldwide. To collaborate to reduce this demand, this paper aims to present a computational model to analyze the performance of an earth–air heat exchanger (EAHE) based on computational fluid dynamics using the ANSYS/Fluent® software in the simulations. This passive air conditioning system uses the soil as a heat exchanger, taking advantage of the fact that the temperature of the soil at a certain depth remains relatively constant, regardless of the weather conditions above the surface, promoting heating, cooling, or ventilation for buildings. The air temperature values obtained were compared with experimental data from sensors installed in an EAHE at the Federal University of Technology—Parana, Ponta Grossa/Brazil (25.1° South, 50.16° West) to validate the computational model. A high computational effort would be demanded to perform these simulations involving the whole soil domain and the climatic boundary conditions. In order to optimize the numerical analysis of EAHE, two reduced models for the soil and heat exchanger domains were verified. First, a constant temperature of 23.7 °C was imposed on the surface of the exchanger tube, corresponding to the average soil temperature at a depth of 1.5 m. Afterward, a reduced soil domain extending 0.5 m in all directions from the heat exchanger serpentine was considered. Likewise, constant temperatures were imposed on the upper and lower surfaces of the soil domain, also obtained experimentally. In both cases, the temperature values obtained through the fast simulations showed good agreement compared to the experimental values. Barely explored in the literature, the thermal behavior of the two identical indoor environments at the university was also compared, in which the climatized environment, with the EAHE working in a closed loop, obtained milder and smaller amplitude air temperatures.
- Open Access
- 1 January 2023
- Published by Even3 in Anais Do Congresso Internacional de Engenharia Mecânica E Industrial
- Vol. 1, 1
TROCADOR DE CALOR SOLO-AR (TCSA): UMA ALTERNATIVA SUSTENTÁVEL PARA CONDICIONAMENTO DE AR
Anais do Congresso Internacional de Engenharia Mecânica e Industrial (2764-4294) - Trocador De Calor Solo-Ar (Tcsa): Uma Alternativa Sustentável Para Condicionamento De Ar
- 1 January 2023
- Published by Even3 in Anais Do Congresso Internacional de Engenharia Mecânica E Industrial
- Vol. 1, 1
Open AccessTROCADOR DE CALOR SOLO-AR (TCSA): UMA ALTERNATIVA SUSTENTÁVEL PARA CONDICIONAMENTO DE AR
Anais do Congresso Internacional de Engenharia Mecânica e Industrial (2764-4294) - Trocador De Calor Solo-Ar (Tcsa): Uma Alternativa Sustentável Para Condicionamento De Ar
- Open Access
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 21 (4) , 143-156
Modelagem para o acoplamento do transporte de umidade, calor e cloreto de sódio em estruturas de concreto
Resumo A durabilidade dos materiais está diretamente ligada a sua capacidade de resistir aos agentes de deterioração. Nesse contexto, as estruturas de concreto podem estar sujeitas aos efeitos da umidade e do sal, reduzindo consideravelmente o seu tempo de vida útil. Os sais que entram pelos poros do concreto podem atacar sua armadura, bem como se concentrar em alguns pontos e cristalizar, gerando trincas e fissuras e reduzindo, deste modo, a sua resistência. Nesse sentido, este trabalho apresenta um modelo matemático para o transporte acoplado de calor, umidade e sal em meios porosos. As equações governantes foram discretizadas por meio do método dos volumes finitos resolvidas simultaneamente a partir do algoritmo MultiTriDiagonal Matrix Algorithm (MTDMA). A verificação do modelo foi realizada a partir da comparação de estudos de casos obtidos na literatura, mostrando uma boa concordância entre os resultados.
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 21 (4) , 143-156
Open AccessModelagem para o acoplamento do transporte de umidade, calor e cloreto de sódio em estruturas de concreto
Resumo A durabilidade dos materiais está diretamente ligada a sua capacidade de resistir aos agentes de deterioração. Nesse contexto, as estruturas de concreto podem estar sujeitas aos efeitos da umidade e do sal, reduzindo consideravelmente o seu tempo de vida útil. Os sais que entram pelos poros do concreto podem atacar sua armadura, bem como se concentrar em alguns pontos e cristalizar, gerando trincas e fissuras e reduzindo, deste modo, a sua resistência. Nesse sentido, este trabalho apresenta um modelo matemático para o transporte acoplado de calor, umidade e sal em meios porosos. As equações governantes foram discretizadas por meio do método dos volumes finitos resolvidas simultaneamente a partir do algoritmo MultiTriDiagonal Matrix Algorithm (MTDMA). A verificação do modelo foi realizada a partir da comparação de estudos de casos obtidos na literatura, mostrando uma boa concordância entre os resultados.
- 5 July 2021
- Published by Walter de Gruyter GmbH
- p. 61-92
Distinct approaches to reproduce hygrothermal behavior of building materials based black-box models
Distinct approaches to reproduce hygrothermal behavior of building materials based black-box models was published in Frontiers of Science and Technology on page 61.
- 5 July 2021
- Published by Walter de Gruyter GmbH
- p. 61-92
Distinct approaches to reproduce hygrothermal behavior of building materials based black-box models
Distinct approaches to reproduce hygrothermal behavior of building materials based black-box models was published in Frontiers of Science and Technology on page 61.
- Open Access
- 1 April 2021
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 21 (2) , 435-455
Avaliação numérica do desempenho térmico de diferentes configurações de trocadores de calor solo-ar
Resumo Visando à diminuição do consumo de energia em edificações, devido ao uso de equipamentos de aquecimento, ventilação e ar condicionado, observa-se o aproveitamento do solo como fonte de energia. Por sua alta capacidade térmica, o solo atua como um reservatório térmico, aquecendo ou resfriando o ar do ambiente interno das edificações, conforme as condições climáticas aplicadas. Sendo assim, aplicou-se o método dos volumes finitos neste trabalho para análise do desempenho térmico desse tipo de trocador de calor solo-ar (TCSA). Inicialmente, os efeitos das propriedades térmicas do solo, da velocidade de escoamento do ar e do diâmetro do duto no desempenho térmico do TCSA foram investigados em regime permanente, por ser uma condição limite. Além disso, analisaram-se duas configurações para a distribuição do duto no solo (dois e quatro passos). A partir dos resultados, notou-se que o melhor desempenho para o TCSA foi obtido utilizando o solo saturado e operando com uma velocidade de ar de 2,5 m/s em um duto com diâmetro de 0,10 m. Em seguida, observou-se que uma distância entre as linhas de centro dos dutos de 0,5 m foi a mais apropriada. Adicionalmente, executaram-se simulações em regime transiente, empregando-se condições climáticas por meio de funções senoidais.
- 1 April 2021
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 21 (2) , 435-455
Open AccessAvaliação numérica do desempenho térmico de diferentes configurações de trocadores de calor solo-ar
Resumo Visando à diminuição do consumo de energia em edificações, devido ao uso de equipamentos de aquecimento, ventilação e ar condicionado, observa-se o aproveitamento do solo como fonte de energia. Por sua alta capacidade térmica, o solo atua como um reservatório térmico, aquecendo ou resfriando o ar do ambiente interno das edificações, conforme as condições climáticas aplicadas. Sendo assim, aplicou-se o método dos volumes finitos neste trabalho para análise do desempenho térmico desse tipo de trocador de calor solo-ar (TCSA). Inicialmente, os efeitos das propriedades térmicas do solo, da velocidade de escoamento do ar e do diâmetro do duto no desempenho térmico do TCSA foram investigados em regime permanente, por ser uma condição limite. Além disso, analisaram-se duas configurações para a distribuição do duto no solo (dois e quatro passos). A partir dos resultados, notou-se que o melhor desempenho para o TCSA foi obtido utilizando o solo saturado e operando com uma velocidade de ar de 2,5 m/s em um duto com diâmetro de 0,10 m. Em seguida, observou-se que uma distância entre as linhas de centro dos dutos de 0,5 m foi a mais apropriada. Adicionalmente, executaram-se simulações em regime transiente, empregando-se condições climáticas por meio de funções senoidais.
- 14 May 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (11) , 8945-8953
Numerical Assessment of Convective Heat Transfer Coefficients in Buildings Conditioned by Parallel Split Systems
- 14 May 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (11) , 8945-8953
Numerical Assessment of Convective Heat Transfer Coefficients in Buildings Conditioned by Parallel Split Systems
- Open Access
Genetic Algorithm Applied to Multi-Criteria Selection of Thermal Insulation on Industrial Shed Roof
The rational use of energy has motivated research on improving the energy efficiency of buildings, which are responsible for a large share of world consumption. A strategy to achieve this goal is the application of optimized thermal insulation on a building envelope to avoid thermal exchanges with the external environment, reducing the use of heating, ventilation and air-conditioning (HVAC) systems. In order to contribute to the best choice of insulation applied to an industrial shed roof, this study aims to provide an optimization tool to assist this process. Beyond the thermal comfort and cost of the insulation, some hygrothermic properties also have been analysed to obtain the best insulation option. To implement this optimization technique, several thermo-energetic simulations of an industrial shed were performed using the Domus software, applying 4 types of insulation material (polyurethane, expanded polystyrene, rockwool and glass wool) on the roof. Ten thicknesses ranging from 0.5 cm to 5 cm were considered, with the purpose of obtaining different thermal comfort indexes (PPD, predicted percentage dissatisfied). Posteriorly, the best insulation ranking has been obtained from the weights assigned to the parameters in the objective function, using the technique of the genetic algorithm (GA) applied to multi-criteria selection. The optimization results showed that polyurethane (PU) insulation, applied with a thickness of 1 cm was the best option for the roof, considering the building functional parameters, occupant metabolic activity, clothing insulation and climate conditions. On the other hand, when the Brazilian standard was utilized, rock wool (2 cm) was considered the best choice.
Open AccessGenetic Algorithm Applied to Multi-Criteria Selection of Thermal Insulation on Industrial Shed Roof
The rational use of energy has motivated research on improving the energy efficiency of buildings, which are responsible for a large share of world consumption. A strategy to achieve this goal is the application of optimized thermal insulation on a building envelope to avoid thermal exchanges with the external environment, reducing the use of heating, ventilation and air-conditioning (HVAC) systems. In order to contribute to the best choice of insulation applied to an industrial shed roof, this study aims to provide an optimization tool to assist this process. Beyond the thermal comfort and cost of the insulation, some hygrothermic properties also have been analysed to obtain the best insulation option. To implement this optimization technique, several thermo-energetic simulations of an industrial shed were performed using the Domus software, applying 4 types of insulation material (polyurethane, expanded polystyrene, rockwool and glass wool) on the roof. Ten thicknesses ranging from 0.5 cm to 5 cm were considered, with the purpose of obtaining different thermal comfort indexes (PPD, predicted percentage dissatisfied). Posteriorly, the best insulation ranking has been obtained from the weights assigned to the parameters in the objective function, using the technique of the genetic algorithm (GA) applied to multi-criteria selection. The optimization results showed that polyurethane (PU) insulation, applied with a thickness of 1 cm was the best option for the roof, considering the building functional parameters, occupant metabolic activity, clothing insulation and climate conditions. On the other hand, when the Brazilian standard was utilized, rock wool (2 cm) was considered the best choice.
- Open Access
Numerical Two-Dimensional Steady-State Evaluation of the Thermal Transmittance Reduction in Hollow Blocks
After the first concerns about global energy consumption around the 70 s, some standards were established with the aim of improving the energy efficiency in buildings. In this context, according to the US Department of Energy, heating, ventilation, and air conditioning (HVAC) systems comprise about 50% of the building energy consumption and 20% of total consumption in the United States. Energy consumption of this kind of equipment depends on several factors, one of the most important factors being the heat transfer through the building envelope. In the walls, hollow concrete blocks have become common in recent years due to advantages such as their strength, their space for pipes and wiring, and fast construction, among others. In order to reduce the thermal load, several forms of insulation were tested on these constructive elements. Thus, effects of the low emissivity, insulating material, radiant shields, and baffles on the inner cavities of the blocks are presented in this paper. Effects of temperature differences between the exterior surfaces on the thermal transmittance and on the combined average heat transfer coefficient inside the cavities are also shown.
Open AccessNumerical Two-Dimensional Steady-State Evaluation of the Thermal Transmittance Reduction in Hollow Blocks
After the first concerns about global energy consumption around the 70 s, some standards were established with the aim of improving the energy efficiency in buildings. In this context, according to the US Department of Energy, heating, ventilation, and air conditioning (HVAC) systems comprise about 50% of the building energy consumption and 20% of total consumption in the United States. Energy consumption of this kind of equipment depends on several factors, one of the most important factors being the heat transfer through the building envelope. In the walls, hollow concrete blocks have become common in recent years due to advantages such as their strength, their space for pipes and wiring, and fast construction, among others. In order to reduce the thermal load, several forms of insulation were tested on these constructive elements. Thus, effects of the low emissivity, insulating material, radiant shields, and baffles on the inner cavities of the blocks are presented in this paper. Effects of temperature differences between the exterior surfaces on the thermal transmittance and on the combined average heat transfer coefficient inside the cavities are also shown.