Mengyuan He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mengyuan He has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Ning Shang
College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, China
7 shared publicationsBo Zheng
College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang 464000, China
4 shared publicationsYu Xiao
College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang 464000, China
3 shared publicationsYuanhang Wei
College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang 464000, China
3 shared publications- Zhihong Liu
Hubei University
3 shared publications Gege Yue
College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, China
2 shared publications
Latest Publications
- Open Access
- 26 October 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (45) , 31720-31727
Semiquantitative and visual detection of ferric ions in real samples using a fluorescent paper-based analytical device constructed with green emitting carbon dots
A simple and portable paper-based analytical device was developed for visual and semiquantitative detection of ferric ion in real samples using green emitting carbon dots (CDs), which were prepared via microwave method using sodium citrate, urea and sodium hydroxide as raw materials and then loaded on the surface of paper substrate. When Fe3+ exists, the green fluorescence of CDs was quenched and significant color change from green to dark blue were observed, resulting the visual detection of Fe3+ with a minimum distinguishable concentration of 100 μM. By analyzing the intensity changes of green channels of test paper with the help of smartphone, the semiquantitative detection was realized within the range of 100 μM to 1200 μM. The proposed paper-based analytical devices have great application prospects in on site detection of Fe3+ in real samples.
- 26 October 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (45) , 31720-31727
Open AccessSemiquantitative and visual detection of ferric ions in real samples using a fluorescent paper-based analytical device constructed with green emitting carbon dots
A simple and portable paper-based analytical device was developed for visual and semiquantitative detection of ferric ion in real samples using green emitting carbon dots (CDs), which were prepared via microwave method using sodium citrate, urea and sodium hydroxide as raw materials and then loaded on the surface of paper substrate. When Fe3+ exists, the green fluorescence of CDs was quenched and significant color change from green to dark blue were observed, resulting the visual detection of Fe3+ with a minimum distinguishable concentration of 100 μM. By analyzing the intensity changes of green channels of test paper with the help of smartphone, the semiquantitative detection was realized within the range of 100 μM to 1200 μM. The proposed paper-based analytical devices have great application prospects in on site detection of Fe3+ in real samples.
- 19 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5769-5779
Portable smartphone-assisted ratiometric fluorescent test paper based on one-pot synthesized dual emissive carbon dots for visualization and quantification of mercury ions
Dual-emissive fluorescent carbon dots (CDs) were prepared through the solvothermal method with citric acid and urea as raw materials and dimethylformamide as the solvent. Two emission peaks were observed at 465 nm and 630 nm. Hg2+ could selectively quench the fluorescence at 630 nm, but the fluorescence intensity at 465 nm was less affected. Accordingly, a ratiometric fluorescence sensor for Hg2+ detection was developed, with a linear detection range of 0.5–40 μM and a limit of detection (LOD) of 37 nM. The dual-emissive CDs were loaded on the surface of the filter paper to fabricate Hg2+ detection test paper. The color of the test paper could be changed from pink purple to blue by the addition of Hg2+, and thus the qualitative and quantitative detection of Hg2+ could be realized. The concentration distinguishable by the naked eye reached 50 μM, and the quantitative detection range was 5–10,000 μM. This method shows excellent selectivity for Hg2+ and can be used to detect Hg2+ in real water samples, providing a highly potential sensing platform for rapid on-site detection of mercury ions. Graphical Abstract
- 19 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5769-5779
Portable smartphone-assisted ratiometric fluorescent test paper based on one-pot synthesized dual emissive carbon dots for visualization and quantification of mercury ions
Dual-emissive fluorescent carbon dots (CDs) were prepared through the solvothermal method with citric acid and urea as raw materials and dimethylformamide as the solvent. Two emission peaks were observed at 465 nm and 630 nm. Hg2+ could selectively quench the fluorescence at 630 nm, but the fluorescence intensity at 465 nm was less affected. Accordingly, a ratiometric fluorescence sensor for Hg2+ detection was developed, with a linear detection range of 0.5–40 μM and a limit of detection (LOD) of 37 nM. The dual-emissive CDs were loaded on the surface of the filter paper to fabricate Hg2+ detection test paper. The color of the test paper could be changed from pink purple to blue by the addition of Hg2+, and thus the qualitative and quantitative detection of Hg2+ could be realized. The concentration distinguishable by the naked eye reached 50 μM, and the quantitative detection range was 5–10,000 μM. This method shows excellent selectivity for Hg2+ and can be used to detect Hg2+ in real water samples, providing a highly potential sensing platform for rapid on-site detection of mercury ions. Graphical Abstract
- 10 May 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (6) , 1-9
Ultrasensitive fluorescence detection of microRNA through DNA-induced assembly of carbon dots on gold nanoparticles with no signal amplification strategy
An ultrasensitive fluorescence assay strategy on the basis of carbon dots (CDs) and cDNA-modified gold nanoparticles (AuNP-cDNA) was developed for the determination of microRNA-21 (miRNA-21) via internal filtering effect (IFE). Positively charged CDs (PEI-CDs), the fluorophores in IFE, were synthesized via a hydrothermal method using polyethyleneimine (PEI) as surface ligand. The maximum emission wavelength is located at 500 nm under the excitation of 410 nm. AuNPs, the absorbers, were modified with single-stranded DNA (cDNA), which is completely complementary to miRNA-21. The fluorescence of PEI-CDs is quenched due to the assembly of PEI-CDs and AuNPs-cDNA. In the presence of miRNA-21, the hybridization between miRNA-21 and cDNA causes the release of PEI-CDs and the recovery of fluorescence intensity.The fluorescence recovery degree is linearly correlated with the logarithm of miRNA-21 concentration in the range of 1–1000 fM. This method can be applied to determine miRNA-21 in real serum samples, and the detection results are in well agreement with those of qRT-PCR. The determination of miRNA-21 spiked into diluted human serum samples displays satisfactory recovery within the range 88.44–112.7%, which confirmed the reliability for miRNAs detection in real samples. Graphical Abstract
- 10 May 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (6) , 1-9
Ultrasensitive fluorescence detection of microRNA through DNA-induced assembly of carbon dots on gold nanoparticles with no signal amplification strategy
An ultrasensitive fluorescence assay strategy on the basis of carbon dots (CDs) and cDNA-modified gold nanoparticles (AuNP-cDNA) was developed for the determination of microRNA-21 (miRNA-21) via internal filtering effect (IFE). Positively charged CDs (PEI-CDs), the fluorophores in IFE, were synthesized via a hydrothermal method using polyethyleneimine (PEI) as surface ligand. The maximum emission wavelength is located at 500 nm under the excitation of 410 nm. AuNPs, the absorbers, were modified with single-stranded DNA (cDNA), which is completely complementary to miRNA-21. The fluorescence of PEI-CDs is quenched due to the assembly of PEI-CDs and AuNPs-cDNA. In the presence of miRNA-21, the hybridization between miRNA-21 and cDNA causes the release of PEI-CDs and the recovery of fluorescence intensity.The fluorescence recovery degree is linearly correlated with the logarithm of miRNA-21 concentration in the range of 1–1000 fM. This method can be applied to determine miRNA-21 in real serum samples, and the detection results are in well agreement with those of qRT-PCR. The determination of miRNA-21 spiked into diluted human serum samples displays satisfactory recovery within the range 88.44–112.7%, which confirmed the reliability for miRNAs detection in real samples. Graphical Abstract
- Open Access
- 15 June 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (34) , 21137-21144
An ultrasensitive colorimetric and fluorescence dual-readout assay for glutathione with a carbon dot–MnO2 nanosheet platform based on the inner filter effect
An ultrasensitive colorimetric and fluorescence dual-readout assay based on carbon dot–MnO2 nanosheets platform was developed for GSH detection in human body fluid samples.
- 15 June 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (34) , 21137-21144
Open AccessAn ultrasensitive colorimetric and fluorescence dual-readout assay for glutathione with a carbon dot–MnO2 nanosheet platform based on the inner filter effect
An ultrasensitive colorimetric and fluorescence dual-readout assay based on carbon dot–MnO2 nanosheets platform was developed for GSH detection in human body fluid samples.
- 1 January 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1143, 93-100
Paper-based upconversion fluorescence aptasensor for the quantitative detection of immunoglobulin E in human serum
- 1 January 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1143, 93-100
Paper-based upconversion fluorescence aptasensor for the quantitative detection of immunoglobulin E in human serum
- Open Access
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (15) , 5372
Correction: A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum
Correction for ‘A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum’ by Mengyuan He et al., Analyst, 2020, 145, 4181–4187, DOI: 10.1039/c9an02307k.
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (15) , 5372
Open AccessCorrection: A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum
Correction for ‘A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum’ by Mengyuan He et al., Analyst, 2020, 145, 4181–4187, DOI: 10.1039/c9an02307k.
- 6 May 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (12) , 4181-4187
A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum
In this paper, a paper-supported analytical device based on a sandwich immunoreaction and luminescence resonance energy transfer (LRET) was reported for the visual and quantitative determination of a cancer biomarker, in which upconversion nanoparticles (UCNPs) were located on the surface of the paper as energy donors and gold nanoparticles (AuNPs) were used as energy acceptors. Upon the recognition of the cancer biomarker by two rationally selected antibodies, the upconversion luminescence was quenched by the AuNPs in a biomarker concentration-dependent manner. As a model target, CEA was detected using this immunosensor, and a linear relationship within 0.5–30 ng mL−1 was obtained in buffer solution, with a detection limit of 0.21 ng mL−1. The immunosensor was also applicable in 20-fold diluted human serum with a linear range of 0.5–30 ng mL−1 and a detection limit of 0.36 ng mL−1. This technique also realized the qualitative judgment of the critical concentration of CEA in serum samples by the naked eye. This approach displays great application potential for point-of-care testing in clinical applications, as well as the potentiality to be extended to other kinds of disease-related biomolecules.
- 6 May 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (12) , 4181-4187
A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum
In this paper, a paper-supported analytical device based on a sandwich immunoreaction and luminescence resonance energy transfer (LRET) was reported for the visual and quantitative determination of a cancer biomarker, in which upconversion nanoparticles (UCNPs) were located on the surface of the paper as energy donors and gold nanoparticles (AuNPs) were used as energy acceptors. Upon the recognition of the cancer biomarker by two rationally selected antibodies, the upconversion luminescence was quenched by the AuNPs in a biomarker concentration-dependent manner. As a model target, CEA was detected using this immunosensor, and a linear relationship within 0.5–30 ng mL−1 was obtained in buffer solution, with a detection limit of 0.21 ng mL−1. The immunosensor was also applicable in 20-fold diluted human serum with a linear range of 0.5–30 ng mL−1 and a detection limit of 0.36 ng mL−1. This technique also realized the qualitative judgment of the critical concentration of CEA in serum samples by the naked eye. This approach displays great application potential for point-of-care testing in clinical applications, as well as the potentiality to be extended to other kinds of disease-related biomolecules.
- 22 January 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (3) , 1530-1534
Portable Upconversion Nanoparticles-Based Paper Device for Field Testing of Drug Abuse
We report the first portable upconversion nanoparticles (UCNPs)-based paper device for road-side field testing of cocaine. Upon the recognition of cocaine by two pieces of rationally designed aptamer fragments, the luminescence of UCNPs immobilized on the paper is quenched by Au nanoparticles (AuNPs), which indicates the cocaine concentration. This device can give quantitative results in a short time with high sensitivity using only a smartphone as the apparatus. Moreover, this device is applicable in human saliva samples, and it also can be used to monitor the cocaine content change in blood samples. The results of this work demonstrate the prospect of developing UCNPs-based paper devices for field testing of drug abuse.
- 22 January 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (3) , 1530-1534
Portable Upconversion Nanoparticles-Based Paper Device for Field Testing of Drug Abuse
We report the first portable upconversion nanoparticles (UCNPs)-based paper device for road-side field testing of cocaine. Upon the recognition of cocaine by two pieces of rationally designed aptamer fragments, the luminescence of UCNPs immobilized on the paper is quenched by Au nanoparticles (AuNPs), which indicates the cocaine concentration. This device can give quantitative results in a short time with high sensitivity using only a smartphone as the apparatus. Moreover, this device is applicable in human saliva samples, and it also can be used to monitor the cocaine content change in blood samples. The results of this work demonstrate the prospect of developing UCNPs-based paper devices for field testing of drug abuse.
- 3 December 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (24) , 11691-11694
Paper-Based Microfluidic Device with Upconversion Fluorescence Assay
A paper-based microfluidic device with upconversion fluorescence assay (named as UC-μPAD) is proposed. The device is fabricated on a normal office printing sheet with a simple plotting method. Upconversion phosphors (UCPs) tagged with specific probes are spotted to the test zones on the μPAD, followed by the introduction of assay targets. Upconversion fluorescence measurements are directly conducted on the test zones after the completion of the probe-to-target reactions, without any post-treatments. The UC-μPAD features very easy fabrication and operation, simple and fast detection, low cost, and high sensitivity. UC-μPAD is a promising prospect for a clinical point-of-care test.
- 3 December 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (24) , 11691-11694
Paper-Based Microfluidic Device with Upconversion Fluorescence Assay
A paper-based microfluidic device with upconversion fluorescence assay (named as UC-μPAD) is proposed. The device is fabricated on a normal office printing sheet with a simple plotting method. Upconversion phosphors (UCPs) tagged with specific probes are spotted to the test zones on the μPAD, followed by the introduction of assay targets. Upconversion fluorescence measurements are directly conducted on the test zones after the completion of the probe-to-target reactions, without any post-treatments. The UC-μPAD features very easy fabrication and operation, simple and fast detection, low cost, and high sensitivity. UC-μPAD is a promising prospect for a clinical point-of-care test.