Kiyoshi Kanno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kiyoshi Kanno has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Masaaki Andou
25 shared publicationsMari Sawada
19 shared publicationsShiori Yanai
Department of Obstetrics and Gynecology, Kurashiki Medical Center, Kurashiki, Japan
19 shared publicationsShintaro Sakate
Department of Obstetrics and Gynecology, Kurashiki Medical Center, Kurashiki, Japan
10 shared publicationsSayaka Masuda
9 shared publicationsTsutomu Hoshiba
8 shared publications
Latest Publications
- 17 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Robot-assisted hysterectomy for large uteri: perioperative outcomes with the da Vinci Xi and SP systems
- 17 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Robot-assisted hysterectomy for large uteri: perioperative outcomes with the da Vinci Xi and SP systems
- Open Access
- 23 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8274
Simultaneous Single-Port Robotic Excision of Diaphragmatic Endometriosis and Mucosa-Sparing Nodulectomy in Rectal Endometriosis
The simultaneous appearance of symptomatic severe pelvic and diaphragmatic deep endometriosis represents a particular challenge in surgical treatment of the disease. We report a symptomatic patient with a history of six previous laparoscopic surgeries for endometriosis who underwent a single-port robotic-assisted complete excision of histopathologically confirmed endometriosis with combined mucosa-sparing rectal nodulectomy and full-thickness resection of the central right diaphragm, performed through a single 3 cm supraumbilical incision. The single-port robotic approach, recently introduced into gynecological minimally invasive surgery, enabled resection of two anatomically distant disease sites—the deep pelvis and the right hemidiaphragm—through one access port without repositioning of the port site. To the best of our knowledge, this is the first case report on simultaneous single-port robotic excision of diaphragmatic and rectal deep endometriosis.
- 23 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8274
Open AccessSimultaneous Single-Port Robotic Excision of Diaphragmatic Endometriosis and Mucosa-Sparing Nodulectomy in Rectal Endometriosis
The simultaneous appearance of symptomatic severe pelvic and diaphragmatic deep endometriosis represents a particular challenge in surgical treatment of the disease. We report a symptomatic patient with a history of six previous laparoscopic surgeries for endometriosis who underwent a single-port robotic-assisted complete excision of histopathologically confirmed endometriosis with combined mucosa-sparing rectal nodulectomy and full-thickness resection of the central right diaphragm, performed through a single 3 cm supraumbilical incision. The single-port robotic approach, recently introduced into gynecological minimally invasive surgery, enabled resection of two anatomically distant disease sites—the deep pelvis and the right hemidiaphragm—through one access port without repositioning of the port site. To the best of our knowledge, this is the first case report on simultaneous single-port robotic excision of diaphragmatic and rectal deep endometriosis.
- 20 July 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 691
Real-time near-infrared fluorescence-guided identification of the hypogastric nerve during robot-assisted nerve-sparing surgery for deep endometriosis
Identification and preservation of pelvic autonomic nerves is essential for preventing postoperative functional disorders during surgery for deep endometriosis (DE); however, nerve-sparing surgery in patients with severe fibrosis and cul-de-sac obliteration remains technically demanding. Herein, we describe a surgical technique and perioperative outcomes of fluorescence-guided intraoperative identification of the hypogastric nerve using indocyanine green (ICG) during robot-assisted nerve-sparing hysterectomy (NSH) for DE. This retrospective cohort study included 41 consecutive patients who underwent robot-assisted NSH for DE between November 2020 and December 2025. A low-dose intravenous bolus of ICG (0.25 mg/kg) was administered intraoperatively, and near-infrared fluorescence imaging was used to facilitate intraoperative identification of the hypogastric nerve. Fluorescence onset was retrospectively assessed via surgical video review. The hypogastric nerve was successfully identified in 38 of 41 cases, yielding an overall identification rate of 92.7% (95% CI, 80.6–97.5%). The median time from ICG injection to fluorescence onset was 25 s (range, 12–42 s). No ICG-related adverse events or major perioperative complications occurred. In the three unsuccessful cases, nerve-sparing surgery was completed under conventional white-light visualization without conversion or additional complications. Real-time near-infrared ICG fluorescence imaging is a simple and minimally invasive adjunctive technique that facilitates fluorescence-guided intraoperative identification of the hypogastric nerve during robot-assisted nerve-sparing pelvic surgery. This approach may improve the reproducibility of anatomical nerve-sparing dissection and facilitate safer anatomical navigation during complex pelvic surgery. Larger prospective studies are warranted to validate these preliminary findings.
- 20 July 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 691
Real-time near-infrared fluorescence-guided identification of the hypogastric nerve during robot-assisted nerve-sparing surgery for deep endometriosis
Identification and preservation of pelvic autonomic nerves is essential for preventing postoperative functional disorders during surgery for deep endometriosis (DE); however, nerve-sparing surgery in patients with severe fibrosis and cul-de-sac obliteration remains technically demanding. Herein, we describe a surgical technique and perioperative outcomes of fluorescence-guided intraoperative identification of the hypogastric nerve using indocyanine green (ICG) during robot-assisted nerve-sparing hysterectomy (NSH) for DE. This retrospective cohort study included 41 consecutive patients who underwent robot-assisted NSH for DE between November 2020 and December 2025. A low-dose intravenous bolus of ICG (0.25 mg/kg) was administered intraoperatively, and near-infrared fluorescence imaging was used to facilitate intraoperative identification of the hypogastric nerve. Fluorescence onset was retrospectively assessed via surgical video review. The hypogastric nerve was successfully identified in 38 of 41 cases, yielding an overall identification rate of 92.7% (95% CI, 80.6–97.5%). The median time from ICG injection to fluorescence onset was 25 s (range, 12–42 s). No ICG-related adverse events or major perioperative complications occurred. In the three unsuccessful cases, nerve-sparing surgery was completed under conventional white-light visualization without conversion or additional complications. Real-time near-infrared ICG fluorescence imaging is a simple and minimally invasive adjunctive technique that facilitates fluorescence-guided intraoperative identification of the hypogastric nerve during robot-assisted nerve-sparing pelvic surgery. This approach may improve the reproducibility of anatomical nerve-sparing dissection and facilitate safer anatomical navigation during complex pelvic surgery. Larger prospective studies are warranted to validate these preliminary findings.
- 17 March 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 354
Comparative analysis of nerve-sparing modified radical hysterectomy for deep endometriosis using the da Vinci SP versus Xi systems
- 17 March 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 354
Comparative analysis of nerve-sparing modified radical hysterectomy for deep endometriosis using the da Vinci SP versus Xi systems
- 14 January 2026
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 33 (7) , 861
Is Identifying the Ureter Using Indocyanine Green in Severe Deep Endometriosis Always Useful?
- 14 January 2026
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 33 (7) , 861
Is Identifying the Ureter Using Indocyanine Green in Severe Deep Endometriosis Always Useful?
- Open Access
- 8 December 2025
- Published by Galenos Yayinevi in Human Reproduction Open
- Vol. 17 (4) , 411-412
Fluorescence-guided nerve-sparing surgery for deep endometriosis using indocyanine green
Fluorescence-guided nerve-sparing surgery for deep endometriosis using indocyanine green - Facts, Views and Vision in ObGyn
- 8 December 2025
- Published by Galenos Yayinevi in Human Reproduction Open
- Vol. 17 (4) , 411-412
Open AccessFluorescence-guided nerve-sparing surgery for deep endometriosis using indocyanine green
Fluorescence-guided nerve-sparing surgery for deep endometriosis using indocyanine green - Facts, Views and Vision in ObGyn
- 23 June 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 19 (1) , 320
Comparing approaches to benign hysterectomy using conventional multi-port and newer single-port robots: a propensity score matching analysis of surgical outcomes and literature review
To compare the surgical outcomes of robot-assisted hysterectomy (RAH) for benign diseases using da Vinci SP (SP) and da Vinci Xi (Xi). A retrospective study with propensity score matching (PSM) analysis. An urban general hospital in Japan. 346 patients who underwent RAH at a single institution between May 2023 and April 2024. A 1:1 PSM analysis was performed using age, body mass index, number of previous deliveries, history of abdominal surgery, uterine weight, and severe endometriosis as covariates. Variables extracted for analysis included operative time, docking time, console time, estimated blood loss (EBL), hemoglobin drop, postoperative hospital stay, major intraoperative complication rates, and postoperative complication rates (Clavien-Dindo classification ≥ Grade 3), conversion to laparotomy, and blood transfusion requirements. After PSM, 262 patients (131 in each group) were included in this study. The median (range) of operative time, docking time, console time, EBL, and postoperative hospital stay were 94 (39-191) vs. 77 (33-194) min (p < 0.001), 2 (1-8) vs. 2 (1-6) min (p=0.088), 66 (27-178) vs. 62 (25-144) min (p=0.003), 5 (5-650) vs. 5 (5-350) mL (p=0.394), and 4 (3-15) vs. 4 (3-9) days (p=0.688), respectively, for SP and Xi groups. No major intraoperative complications, blood transfusions, or conversions to laparotomy were observed in either group. Postoperative complications occurred in 3.1% and 1.5% of patients of SP and Xi groups, respectively (p=0.684). The learning curve for RAH using SP indicated proficiency after eight cases. SP can be a safe alternative robotic platform to Xi for RAH.
- 23 June 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 19 (1) , 320
Comparing approaches to benign hysterectomy using conventional multi-port and newer single-port robots: a propensity score matching analysis of surgical outcomes and literature review
To compare the surgical outcomes of robot-assisted hysterectomy (RAH) for benign diseases using da Vinci SP (SP) and da Vinci Xi (Xi). A retrospective study with propensity score matching (PSM) analysis. An urban general hospital in Japan. 346 patients who underwent RAH at a single institution between May 2023 and April 2024. A 1:1 PSM analysis was performed using age, body mass index, number of previous deliveries, history of abdominal surgery, uterine weight, and severe endometriosis as covariates. Variables extracted for analysis included operative time, docking time, console time, estimated blood loss (EBL), hemoglobin drop, postoperative hospital stay, major intraoperative complication rates, and postoperative complication rates (Clavien-Dindo classification ≥ Grade 3), conversion to laparotomy, and blood transfusion requirements. After PSM, 262 patients (131 in each group) were included in this study. The median (range) of operative time, docking time, console time, EBL, and postoperative hospital stay were 94 (39-191) vs. 77 (33-194) min (p < 0.001), 2 (1-8) vs. 2 (1-6) min (p=0.088), 66 (27-178) vs. 62 (25-144) min (p=0.003), 5 (5-650) vs. 5 (5-350) mL (p=0.394), and 4 (3-15) vs. 4 (3-9) days (p=0.688), respectively, for SP and Xi groups. No major intraoperative complications, blood transfusions, or conversions to laparotomy were observed in either group. Postoperative complications occurred in 3.1% and 1.5% of patients of SP and Xi groups, respectively (p=0.684). The learning curve for RAH using SP indicated proficiency after eight cases. SP can be a safe alternative robotic platform to Xi for RAH.