Kai Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kai Liu has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Yaxiaerjiang Muhetaer
5 shared publications- Guo-Wei Tu
Department of Cardiac Intensive Care Center, Zhongshan Hospital, Fudan University, Shanghai, China
4 shared publications - Ming Zhong
Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
4 shared publications Shi-Min Zhang
4 shared publications- Heling Zhao
Department of Critical Care Medicine, Hebei General Hospital, Shijiazhuang, China
3 shared publications - Shen-Ji Yu
Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China
3 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Wiley in Nursing Open
- Vol. 13 (11) , e70968
Perceptions and Needs Regarding Training in Nurse‐Performed Lung Ultrasound in ICU: A Nationwide Cross‐Sectional Survey
Aim: This research aims to assess the awareness, willingness to participate in training and specific requirements of Chinese ICU nurses regarding nurse‐performed lung ultrasound (LUS). Design: The survey was a cross‐sectional study targeting eligible nurses officially working in Chinese ICUs. Methods: A structured questionnaire was distributed online to ICU nurses nationwide from May 22, 2023 to August 12, 2023. The questionnaire was designed by a multidisciplinary team, and revised based on expert feedback and pilot testing. It consists of three parts: basic information of participants and their departments, nurses' recognition and application experience with LUS and demand for standardized nurse‐performed LUS training. Ethical approval was obtained and informed consent was obtained from all participants before they completed the questionnaire. Results: A total of 1104 questionnaires were analysed. The survey involved 486 hospitals in 31 provinces of Chinese Mainland. Among them, 52.4% were clinical staff nurses without official positions, 86.6% came from tertiary hospitals and 63.0% were working in integrated ICUs. 6.6% of respondents reported that their department did not have an ultrasound machine. 91.8% of the participants were willing to participate in standardized nurse‐performed LUS training. 93.6% of the participants believed that nurses should master the technique, and 97.4% recognized the benefits of mastering LUS for patient treatment. Multivariate regression analysis revealed that non‐staff‐nurse positions, hospital level, previous ultrasound training experience, recognition of the need for mastering LUS, belief in the benefits of mastering LUS for patient treatment, and paying attention to research related to LUS were positively associated with greater willingness to participate in standardized nurse‐performed LUS training. Furthermore, the participants expressed the desire to acquire relevant theoretical and operational knowledge in various aspects, including lung diseases (81.4%), basic knowledge of ultrasound (86.3%), theoretical knowledge (81.8%), practical operation of LUS (85.7%), image interpretation (82%) and nursing plans guided by LUS (80.4%). Conclusion: Chinese ICU nurses showed a high level of willingness to participate in standardized nurse‐performed LUS training and recognized its clinical value. However, their training needs were diverse, and some reported limited access to ultrasound equipment. These findings support the development of structured, accessible training programmes tailored to ICU nursing practice. Implications for the Profession and/or Patient Care: The findings suggest a pressing need for more training and education to promote the use of nurse‐performed LUS in ICUs. Adequate resources, including equipment and time, should be provided to facilitate LUS practice. These measures may help support safer, more timely bedside assessment and patient care. Impact: This study provides preliminary insights into the training preferences of ICU nurses regarding nurse‐performed LUS and identifies factors associated with willingness to participate in training. The findings may inform future structured training programmes and support the integration of nurse‐performed LUS into ICU practice. Reporting Method: This study was reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist for cross‐sectional studies. Patient or Public Contribution: Patients and the public were not involved in the design, conduct, analysis or reporting of this study.
- 5 November 2026
- Published by Wiley in Nursing Open
- Vol. 13 (11) , e70968
Open AccessPerceptions and Needs Regarding Training in Nurse‐Performed Lung Ultrasound in ICU: A Nationwide Cross‐Sectional Survey
Aim: This research aims to assess the awareness, willingness to participate in training and specific requirements of Chinese ICU nurses regarding nurse‐performed lung ultrasound (LUS). Design: The survey was a cross‐sectional study targeting eligible nurses officially working in Chinese ICUs. Methods: A structured questionnaire was distributed online to ICU nurses nationwide from May 22, 2023 to August 12, 2023. The questionnaire was designed by a multidisciplinary team, and revised based on expert feedback and pilot testing. It consists of three parts: basic information of participants and their departments, nurses' recognition and application experience with LUS and demand for standardized nurse‐performed LUS training. Ethical approval was obtained and informed consent was obtained from all participants before they completed the questionnaire. Results: A total of 1104 questionnaires were analysed. The survey involved 486 hospitals in 31 provinces of Chinese Mainland. Among them, 52.4% were clinical staff nurses without official positions, 86.6% came from tertiary hospitals and 63.0% were working in integrated ICUs. 6.6% of respondents reported that their department did not have an ultrasound machine. 91.8% of the participants were willing to participate in standardized nurse‐performed LUS training. 93.6% of the participants believed that nurses should master the technique, and 97.4% recognized the benefits of mastering LUS for patient treatment. Multivariate regression analysis revealed that non‐staff‐nurse positions, hospital level, previous ultrasound training experience, recognition of the need for mastering LUS, belief in the benefits of mastering LUS for patient treatment, and paying attention to research related to LUS were positively associated with greater willingness to participate in standardized nurse‐performed LUS training. Furthermore, the participants expressed the desire to acquire relevant theoretical and operational knowledge in various aspects, including lung diseases (81.4%), basic knowledge of ultrasound (86.3%), theoretical knowledge (81.8%), practical operation of LUS (85.7%), image interpretation (82%) and nursing plans guided by LUS (80.4%). Conclusion: Chinese ICU nurses showed a high level of willingness to participate in standardized nurse‐performed LUS training and recognized its clinical value. However, their training needs were diverse, and some reported limited access to ultrasound equipment. These findings support the development of structured, accessible training programmes tailored to ICU nursing practice. Implications for the Profession and/or Patient Care: The findings suggest a pressing need for more training and education to promote the use of nurse‐performed LUS in ICUs. Adequate resources, including equipment and time, should be provided to facilitate LUS practice. These measures may help support safer, more timely bedside assessment and patient care. Impact: This study provides preliminary insights into the training preferences of ICU nurses regarding nurse‐performed LUS and identifies factors associated with willingness to participate in training. The findings may inform future structured training programmes and support the integration of nurse‐performed LUS into ICU practice. Reporting Method: This study was reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist for cross‐sectional studies. Patient or Public Contribution: Patients and the public were not involved in the design, conduct, analysis or reporting of this study.
- Open Access
- 1 August 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (8) , 948
Artificial intelligence in mechanical ventilation: a narrative review of clinical applications and research gaps
Background and Objective: Artificial intelligence (AI) has been increasingly applied to various aspects of mechanical ventilation (MV) to address the complexity and data-intensive nature of respiratory management in intensive care units (ICUs). Despite rapid growth in algorithm development and frequently reported high predictive performance, the clinical adoption of AI-based tools in MV remains limited. This review aims not only to summarize current AI applications in MV, but more importantly, to critically examine the barriers that have hindered their translation into routine clinical practice. Methods: We conducted a narrative review of studies published up to June 2026 that developed or evaluated AI applications across five key domains of MV: intubation prediction or assistance, ventilation strategy optimization, detection of patient-ventilator asynchrony (PVA), prediction of weaning or extubation, and prediction of noninvasive ventilation (NIV) failure. Studies were identified through PubMed, Google Scholar, and ResearchGate searches. Methodological quality and risk of bias were assessed using the Prediction model Risk Of Bias ASsessment Tool (PROBAST) tool. Key Content and Findings: A total of 104 studies were included. Most AI models demonstrated good to excellent discriminative performance, with reported area under the curve (AUC) values commonly exceeding 0.80. However, the majority of studies were retrospective, single-center, and exploratory in nature, with limited external validation and scarce prospective evaluation. Importantly, few studies assessed the real-world clinical impact of AI-assisted decision-making on patient-centered outcomes, workflow integration, or clinician behavior. Conclusions: Although AI models for MV frequently achieve high performance in controlled research settings, their translation into routine clinical care remains minimal. The primary challenges are no longer related to algorithmic capability, but rather to methodological limitations, lack of generalizability, insufficient integration into clinical workflows, and absence of outcome-driven evidence. Addressing these translational barriers is essential before AI can meaningfully contribute to safe, effective, and sustainable MV management.
- 1 August 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (8) , 948
Open AccessArtificial intelligence in mechanical ventilation: a narrative review of clinical applications and research gaps
Background and Objective: Artificial intelligence (AI) has been increasingly applied to various aspects of mechanical ventilation (MV) to address the complexity and data-intensive nature of respiratory management in intensive care units (ICUs). Despite rapid growth in algorithm development and frequently reported high predictive performance, the clinical adoption of AI-based tools in MV remains limited. This review aims not only to summarize current AI applications in MV, but more importantly, to critically examine the barriers that have hindered their translation into routine clinical practice. Methods: We conducted a narrative review of studies published up to June 2026 that developed or evaluated AI applications across five key domains of MV: intubation prediction or assistance, ventilation strategy optimization, detection of patient-ventilator asynchrony (PVA), prediction of weaning or extubation, and prediction of noninvasive ventilation (NIV) failure. Studies were identified through PubMed, Google Scholar, and ResearchGate searches. Methodological quality and risk of bias were assessed using the Prediction model Risk Of Bias ASsessment Tool (PROBAST) tool. Key Content and Findings: A total of 104 studies were included. Most AI models demonstrated good to excellent discriminative performance, with reported area under the curve (AUC) values commonly exceeding 0.80. However, the majority of studies were retrospective, single-center, and exploratory in nature, with limited external validation and scarce prospective evaluation. Importantly, few studies assessed the real-world clinical impact of AI-assisted decision-making on patient-centered outcomes, workflow integration, or clinician behavior. Conclusions: Although AI models for MV frequently achieve high performance in controlled research settings, their translation into routine clinical care remains minimal. The primary challenges are no longer related to algorithmic capability, but rather to methodological limitations, lack of generalizability, insufficient integration into clinical workflows, and absence of outcome-driven evidence. Addressing these translational barriers is essential before AI can meaningfully contribute to safe, effective, and sustainable MV management.
- Open Access
- 22 July 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1) , 89
EIT-assessed ventilation–perfusion responses to prone positioning and inhaled nitric oxide in mechanically ventilated COVID-19-related ARDS: a prospective sequential study
Prone positioning (PP) and inhaled nitric oxide (iNO) are widely utilized rescue therapies for severe hypoxemia during invasive mechanical ventilation. How
- 22 July 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1) , 89
Open AccessEIT-assessed ventilation–perfusion responses to prone positioning and inhaled nitric oxide in mechanically ventilated COVID-19-related ARDS: a prospective sequential study
Prone positioning (PP) and inhaled nitric oxide (iNO) are widely utilized rescue therapies for severe hypoxemia during invasive mechanical ventilation. How
- Open Access
- 7 May 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1)
Response to “Predicting high-flow nasal cannula failure: beyond static indices toward dynamic physiologic assessment”
- 7 May 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1)
Open AccessResponse to “Predicting high-flow nasal cannula failure: beyond static indices toward dynamic physiologic assessment”
- Open Access
- 1 April 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (4) , 347
Practice of airway clearance in critically ill patients: a cross-sectional survey of respiratory therapists and physiotherapists in China
Background: Airway clearance therapy is crucial for managing critically ill patients with impaired secretion clearance. However, clinical practices and preferences among respiratory therapists (RTs) and physiotherapists (PTs) in China are not well understood. This study aimed to investigate the current practices of airway clearance techniques, device utilization, and implementation barriers among respiratory therapists and physiotherapists in intensive care units across China. Methods: A cross-sectional online survey was conducted from July to August 2023, targeting RTs and PTs across the Chinese mainland. The survey collected demographic information, ACT application patterns, experiences with four specific devices: percussion therapy device, high-frequency chest wall oscillation (HFCWO), mechanical insufflation-exsufflation (MI-E), and continuous high-frequency oscillation therapy (CHFO), as well as perceived implementation challenges. Inferential nonparametric tests were used to analyze the data. Results: Of 1,204 complete responses, 984 reported clinically performing airway clearance therapy. Most practitioners were employed in tertiary hospitals (90.7%) and general ICU (46.7%). The frequency of different ACT modalities varied; conventional methods such as nebulization, humidification, and suctioning were common, whereas device-based methods showed significant variation. While the details of implementing ACT differed, a general consensus was found. The main barriers to ACT implementation included limited equipment availability, shortage of dedicated personnel, and lack of awareness. Conclusions: ACT is widely used in Chinese ICUs, but practices vary significantly. These findings highlight the urgent need for standardized protocols, dedicated training, and increased investment in ACT devices to support evidence-based practices.
- 1 April 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (4) , 347
Open AccessPractice of airway clearance in critically ill patients: a cross-sectional survey of respiratory therapists and physiotherapists in China
Background: Airway clearance therapy is crucial for managing critically ill patients with impaired secretion clearance. However, clinical practices and preferences among respiratory therapists (RTs) and physiotherapists (PTs) in China are not well understood. This study aimed to investigate the current practices of airway clearance techniques, device utilization, and implementation barriers among respiratory therapists and physiotherapists in intensive care units across China. Methods: A cross-sectional online survey was conducted from July to August 2023, targeting RTs and PTs across the Chinese mainland. The survey collected demographic information, ACT application patterns, experiences with four specific devices: percussion therapy device, high-frequency chest wall oscillation (HFCWO), mechanical insufflation-exsufflation (MI-E), and continuous high-frequency oscillation therapy (CHFO), as well as perceived implementation challenges. Inferential nonparametric tests were used to analyze the data. Results: Of 1,204 complete responses, 984 reported clinically performing airway clearance therapy. Most practitioners were employed in tertiary hospitals (90.7%) and general ICU (46.7%). The frequency of different ACT modalities varied; conventional methods such as nebulization, humidification, and suctioning were common, whereas device-based methods showed significant variation. While the details of implementing ACT differed, a general consensus was found. The main barriers to ACT implementation included limited equipment availability, shortage of dedicated personnel, and lack of awareness. Conclusions: ACT is widely used in Chinese ICUs, but practices vary significantly. These findings highlight the urgent need for standardized protocols, dedicated training, and increased investment in ACT devices to support evidence-based practices.
- Open Access
- 3 March 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1) , 27
Prediction of high-flow nasal cannula failure in critically ill patients: a narrative review
High-flow nasal cannula (HFNC) therapy is widely used for respiratory support in critically ill patients, offering benefits such as improved oxygenation an
- 3 March 2026
- Published by Springer Nature in Journal of Intensive Care
- Vol. 14 (1) , 27
Open AccessPrediction of high-flow nasal cannula failure in critically ill patients: a narrative review
High-flow nasal cannula (HFNC) therapy is widely used for respiratory support in critically ill patients, offering benefits such as improved oxygenation an
- 26 February 2026
- Published by Springer Nature in Intensive Care Medicine
- Vol. 52 (4) , 821-823
Ultrasound visualization of diaphragmatic spasm in persistent singultus
- 26 February 2026
- Published by Springer Nature in Intensive Care Medicine
- Vol. 52 (4) , 821-823
Ultrasound visualization of diaphragmatic spasm in persistent singultus
- Open Access
- 26 June 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (6) , 37210
Pleural Effusion Trajectories and Clinical Outcomes in Cardiac Surgery Patients
Background: Pleural effusion (PE) commonly occurs in cardiac surgery patients, often requiring tube drainage. This study aimed to investigate associations between PE drainage trajectories and clinical outcomes in patients undergoing cardiac surgery. Methods: Patients who underwent cardiac surgery and subsequent tube drainage during hospitalization in the intensive care unit, due to substantial PE, were enrolled. PE drainage volumes were recorded daily. The relationships between PE drainage and poor outcome or mortality risks were examined using logistic regression analysis. Latent class growth analysis (LCGA) was used to classify PE trajectories, and the characteristics of each latent class were compared. Results: In total, 386 patients were enrolled over 3 years, of whom 113 (29.3%) developed poor outcomes. These patients had significantly higher average PE drainage volumes on days 2–4 (1.7 vs. 1.2 mL/kg/day; p = 0.002) and days 5–7 (0.9 vs. 0 mL/kg/day; p < 0.001). Average PE drainage volumes during the first 2–4 and 5–7 days were associated with poor outcomes (odds ratio (OR) = 1.10 (95% confidence interval (CI): 1.02–1.20); p = 0.014 and 1.19 (95% CI: 1.08–1.32); p < 0.001, respectively). LCGA identified three distinct PE drainage trajectory classes: persistently high (Class 1, n = 39), gradually declining from high to low (Class 2, n = 128), and persistently low (Class 3, n = 219). Among these, Class 1 had the highest mortality and poor outcome risks. Conclusions: A trend in PE formation demonstrated a strong correlation with mortality and poor outcomes in patients who underwent cardiac surgery. Patients with persistently high PE drainage volumes required close monitoring and attention.
- 26 June 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (6) , 37210
Open AccessPleural Effusion Trajectories and Clinical Outcomes in Cardiac Surgery Patients
Background: Pleural effusion (PE) commonly occurs in cardiac surgery patients, often requiring tube drainage. This study aimed to investigate associations between PE drainage trajectories and clinical outcomes in patients undergoing cardiac surgery. Methods: Patients who underwent cardiac surgery and subsequent tube drainage during hospitalization in the intensive care unit, due to substantial PE, were enrolled. PE drainage volumes were recorded daily. The relationships between PE drainage and poor outcome or mortality risks were examined using logistic regression analysis. Latent class growth analysis (LCGA) was used to classify PE trajectories, and the characteristics of each latent class were compared. Results: In total, 386 patients were enrolled over 3 years, of whom 113 (29.3%) developed poor outcomes. These patients had significantly higher average PE drainage volumes on days 2–4 (1.7 vs. 1.2 mL/kg/day; p = 0.002) and days 5–7 (0.9 vs. 0 mL/kg/day; p < 0.001). Average PE drainage volumes during the first 2–4 and 5–7 days were associated with poor outcomes (odds ratio (OR) = 1.10 (95% confidence interval (CI): 1.02–1.20); p = 0.014 and 1.19 (95% CI: 1.08–1.32); p < 0.001, respectively). LCGA identified three distinct PE drainage trajectory classes: persistently high (Class 1, n = 39), gradually declining from high to low (Class 2, n = 128), and persistently low (Class 3, n = 219). Among these, Class 1 had the highest mortality and poor outcome risks. Conclusions: A trend in PE formation demonstrated a strong correlation with mortality and poor outcomes in patients who underwent cardiac surgery. Patients with persistently high PE drainage volumes required close monitoring and attention.
- 30 May 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 135 (1) , 289-291
Enhancing diaphragmatic ultrasound for weaning success prediction: timing, respiratory drive, and a new index
- 30 May 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 135 (1) , 289-291
Enhancing diaphragmatic ultrasound for weaning success prediction: timing, respiratory drive, and a new index
- Open Access
- 23 May 2025
- Published by Springer Nature in Critical Care
- Vol. 29 (1) , 1-3
Application of one-way speaking valves in adult tracheostomy patients: the time should be earlier
- 23 May 2025
- Published by Springer Nature in Critical Care
- Vol. 29 (1) , 1-3
Open AccessApplication of one-way speaking valves in adult tracheostomy patients: the time should be earlier