Seok-Gyu Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seok-Gyu Kim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chae-Heon Chung
Department of Prosthodontics, School of Dentistry, Chosun University, Gwangju, Republic of Korea
2 shared publications - Mee-Kyoung Son
Professor, Department of Prosthodontics, College of Dentistry, Chosun University, Gwangju, Republic of Korea
2 shared publications - Dohyun Kim
Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, Seoul, Republic of Korea
1 shared publication Dong-Hwan Lee
1 shared publication- Jong-Eun Kim
Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea
1 shared publication - Ju-Ri Lee
Department of Prosthodontics, Samsung Medical Center, College of Medicine, Sungkyunkwan University, Seoul, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (3) , 207-213
Effect of cement washout on loosening of abutment screws andvice versain screw- and cement- retained implant-supported dental prosthesis
Kim SG, et al. J Adv Prosthodont. 2015 Jun;7(3):207-213. https://doi.org/10.4047/jap.2015.7.3.207
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (3) , 207-213
Open AccessEffect of cement washout on loosening of abutment screws andvice versain screw- and cement- retained implant-supported dental prosthesis
Kim SG, et al. J Adv Prosthodont. 2015 Jun;7(3):207-213. https://doi.org/10.4047/jap.2015.7.3.207
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 53 (4) , 330-336
Effect of interproximal undercut on the dimensional accuracy of impression
Lee JR, et al. J Korean Acad Prosthodont. 2015 Oct;53(4):330-336. http://dx.doi.org/10.4047/jkap.2015.53.4.330
- 1 January 2015
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 53 (4) , 330-336
Open AccessEffect of interproximal undercut on the dimensional accuracy of impression
Lee JR, et al. J Korean Acad Prosthodont. 2015 Oct;53(4):330-336. http://dx.doi.org/10.4047/jkap.2015.53.4.330
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 53 (4) , 301-309
Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis
Chung CH, et al. J Korean Acad Prosthodont. 2015 Oct;53(4):301-309. http://dx.doi.org/10.4047/jkap.2015.53.4.301
- 1 January 2015
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 53 (4) , 301-309
Open AccessClinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis
Chung CH, et al. J Korean Acad Prosthodont. 2015 Oct;53(4):301-309. http://dx.doi.org/10.4047/jkap.2015.53.4.301
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (5) , 368-374
Effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations:in vitrostudy of color masking ability
Oh SH, et al. J Adv Prosthodont. 2015 Oct;7(5):368-374. http://dx.doi.org/10.4047/jap.2015.7.5.368
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (5) , 368-374
Open AccessEffect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations:in vitrostudy of color masking ability
Oh SH, et al. J Adv Prosthodont. 2015 Oct;7(5):368-374. http://dx.doi.org/10.4047/jap.2015.7.5.368
- Open Access
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (4) , 428-433
In vitroevaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material
The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (4) , 428-433
Open AccessIn vitroevaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material
The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.