Li Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Li Xie has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Lei Hu
Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of People's Republic of China, Hefei, China (L.H.).
2 shared publications Chong Pei
Department of Respiratory and Critical Care Medicine, The First People's Hospital of Hefei City, Third Affiliated Hospital of Anhui Medical University, Hefei, China
1 shared publicationHang Cheng Zhou
Department of Pathology, The First Affiliated Hospital of the University of Science and Technology of China, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
1 shared publication- Nianan He
Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China
1 shared publication - Nianan He
Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230001, China
1 shared publication Wen Zhong
Department of Pathology, The First Affiliated Hospital of the University of Science and Technology of China, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
1 shared publication
Latest Publications
- Open Access
- 16 February 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 823411
Evaluation of Ultrasound Elastography Combined With Chi-Square Automatic Interactive Detector in Reducing Unnecessary Fine-Needle Aspiration on TIRADS 4 Thyroid Nodules
Background: Conventional ultrasound diagnosis of thyroid nodules (TNs) had a high false-positive rate, resulting in many unnecessary fine-needle aspirations (FNAs).Objective: This study aimed to establish a simple algorithm to reduce unnecessary FNA on TIRADS 4 TNs using different quantitative parameters of ultrasonic elasticity and chi-square automatic interactive detector (CHAID) method.Methods: From January 2020 to May 2021, 432 TNs were included in the study, which were confirmed by FNA or surgical pathology. Each TN was examined using conventional ultrasound, sound touch elastography, and Shell measurement function. The quantitative parameters E and Eshell were recorded, and the Eshell/E values were calculated for each TN. The diagnostic performance of the quantitative parameters was evaluated using the receiver operating characteristic curves. The CHAID was used to classify and analyze the quantitative parameters, and the prediction model was established.Results: A total of 226 TNs were malignant and 206 were benign. Eshell and Eshell/E ratio were included in the classification algorithm, which showed a depth of two ramifications (Eshell/E ≤ 0.988 or 0.988–1.043 or >1.043; if Eshell/E ≤ 0.988, then Eshell ≤ 64.0 or 64.0–74.0 or >74.0; if Eshell/E = 0.988–1.043, then Eshell ≤ 66.0 or > 66.0; if Eshell/E >1.043, then Eshell ≤ 69.0 or >69.0). The unnecessary FNAs could have been avoided in 57.3% of the cases using this algorithm.Conclusion: The prediction model using quantitative parameters had high diagnostic performance; it could quickly distinguish benign lesions and avoid subjective influence to some extent.
- 16 February 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 823411
Open AccessEvaluation of Ultrasound Elastography Combined With Chi-Square Automatic Interactive Detector in Reducing Unnecessary Fine-Needle Aspiration on TIRADS 4 Thyroid Nodules
Background: Conventional ultrasound diagnosis of thyroid nodules (TNs) had a high false-positive rate, resulting in many unnecessary fine-needle aspirations (FNAs).Objective: This study aimed to establish a simple algorithm to reduce unnecessary FNA on TIRADS 4 TNs using different quantitative parameters of ultrasonic elasticity and chi-square automatic interactive detector (CHAID) method.Methods: From January 2020 to May 2021, 432 TNs were included in the study, which were confirmed by FNA or surgical pathology. Each TN was examined using conventional ultrasound, sound touch elastography, and Shell measurement function. The quantitative parameters E and Eshell were recorded, and the Eshell/E values were calculated for each TN. The diagnostic performance of the quantitative parameters was evaluated using the receiver operating characteristic curves. The CHAID was used to classify and analyze the quantitative parameters, and the prediction model was established.Results: A total of 226 TNs were malignant and 206 were benign. Eshell and Eshell/E ratio were included in the classification algorithm, which showed a depth of two ramifications (Eshell/E ≤ 0.988 or 0.988–1.043 or >1.043; if Eshell/E ≤ 0.988, then Eshell ≤ 64.0 or 64.0–74.0 or >74.0; if Eshell/E = 0.988–1.043, then Eshell ≤ 66.0 or > 66.0; if Eshell/E >1.043, then Eshell ≤ 69.0 or >69.0). The unnecessary FNAs could have been avoided in 57.3% of the cases using this algorithm.Conclusion: The prediction model using quantitative parameters had high diagnostic performance; it could quickly distinguish benign lesions and avoid subjective influence to some extent.
- 15 May 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (11) , 2183-2193
Evaluation of the Perinodular Stiffness Potentially Predicts the Malignancy of Thyroid Nodules
Objectives: To evaluate the surrounding tissue stiffness measured by sound touch elastography for differential diagnosis of thyroid nodules (TNs).Methods: Thirty‐nine benign and 90 malignant TNs were included in this study. The conventional ultrasound features, the maximum Young modulus value of the stiffness of the TNs (recorded as E), and the stiffness of the 0.5‐, 1.0‐, 1.5‐, and 2.0‐mm perinodular regions of the TNs (recorded as Eshell0.5, Eshell1.0, Eshell1.5, and Eshell2.0, respectively) were prospectively analyzed and compared to histopathologic results. The abundance of collagen fibers at various widths in the perinodular regions of the TNs was evaluated by Masson staining and ImageJ software (National Institutes of Health, Bethesda, MD). The fibrous structures in the perinodular regions of the TNs were classified.Results: The various Eshell values of malignant TNs were significantly higher than those of benign TNs (P < .001 for all). Eshell0.5 correlated highly with E in the malignant TNs and in all samples (r = 0.722 and 0.772; P < .001 for both). Eshell2 yielded the highest area under the receiving operating characteristic curve value (0.96) for the differential diagnosis of TNs. The abundance of collagen fibers in the 2‐mm perinodular region of the TNs was closely correlated with Eshell2 in the malignant TNs and in all samples (r =0.729 and 0.867; P < .001). The Eshell2 values for different levels of disorder of the tissue surrounding TNs were significantly different (P < .01 for all).Conclusions: Perinodular stiffness measured by sound touch elastography improved the diagnostic accuracy in TNs.
- 15 May 2020
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (11) , 2183-2193
Evaluation of the Perinodular Stiffness Potentially Predicts the Malignancy of Thyroid Nodules
Objectives: To evaluate the surrounding tissue stiffness measured by sound touch elastography for differential diagnosis of thyroid nodules (TNs).Methods: Thirty‐nine benign and 90 malignant TNs were included in this study. The conventional ultrasound features, the maximum Young modulus value of the stiffness of the TNs (recorded as E), and the stiffness of the 0.5‐, 1.0‐, 1.5‐, and 2.0‐mm perinodular regions of the TNs (recorded as Eshell0.5, Eshell1.0, Eshell1.5, and Eshell2.0, respectively) were prospectively analyzed and compared to histopathologic results. The abundance of collagen fibers at various widths in the perinodular regions of the TNs was evaluated by Masson staining and ImageJ software (National Institutes of Health, Bethesda, MD). The fibrous structures in the perinodular regions of the TNs were classified.Results: The various Eshell values of malignant TNs were significantly higher than those of benign TNs (P < .001 for all). Eshell0.5 correlated highly with E in the malignant TNs and in all samples (r = 0.722 and 0.772; P < .001 for both). Eshell2 yielded the highest area under the receiving operating characteristic curve value (0.96) for the differential diagnosis of TNs. The abundance of collagen fibers in the 2‐mm perinodular region of the TNs was closely correlated with Eshell2 in the malignant TNs and in all samples (r =0.729 and 0.867; P < .001). The Eshell2 values for different levels of disorder of the tissue surrounding TNs were significantly different (P < .01 for all).Conclusions: Perinodular stiffness measured by sound touch elastography improved the diagnostic accuracy in TNs.