Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qiang Zou has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Ying Tian

    Beijing Key Laboratory of Powertrain for New Energy Vehicle, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing, China

    3 shared publications
  • Ying Tian

    2 shared publications
  • Zezhao Lin

    Beijing Key Laboratory of Powertrain for New Energy Vehicle, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing, China

    2 shared publications
  • Feng Han

    Beijing Key Laboratory of Powertrain for New Energy Vehicle, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China

    1 shared publication
  • Jiaqi Liu

    Beijing Key Laboratory of Powertrain for New Energy Vehicle School of Mechanical Electronic and Control Engineering Beijing Jiaotong University Beijing 100044 P. R. China

    1 shared publication
  • Jin Han

    Beijing Key Laboratory of Powertrain for New Energy Vehicle School of Mechanical Electronic and Control Engineering Beijing Jiaotong University Beijing 100044 P. R. China

    1 shared publication

Latest Publications

  • Novel Hybrid Control Scheme of a Proton Exchange Membrane Fuel Cell Air Supply System

    by Ying Tian, Qiang Zou, Jiaqi Liu, Jin Han

    A hybrid control scheme of the fuel cell air supply system based on model predictive control (MPC) and proportional integral differential (PID) control is proposed for adjusting the oxygen excess ratio at a given setpoint in this paper. In the proposed scheme, the cooperative control of air compressor and back pressure valve in the fuel cell air supply system is realized by MPC. When the system is in steady state under the MPC, PID is introduced, so that the steady‐state error, which is caused by the mismatch between the control model in MPC and the controlled system during MPC control, can be eliminated. To reduce the mismatch between the control model and the controlled air supply system, back propagation neural network and look‐up table method based on bilinear interpolation are used to calculate the output air flow rate and efficiency of the air compressor in the air supply system. Simulation results show that the proposed control scheme has a better performance compared with proportional integral control, active disturbance rejection control, and single MPC. In addition, the proposed control scheme also shows good fault tolerance in the case of air supply system failure.


  • Open Access

    Data-Driven Fault Diagnosis for Automotive PEMFC Systems Based on the Steady-State Identification

    by Ying Tian, Qiang Zou, Jin Han

    Data-driven diagnosis methods for faults of proton exchange membrane fuel cell (PEMFC) systems can diagnose faults through the state variable data collected during the operation of the PEMFC system. However, the state variable data collected from the PEMFC system during the stack switching between different operating points can easily cause false alarms, such that the practical value of the diagnosis system is reduced. To overcome this problem, a fault diagnosis method for PEMFC systems based on steady-state identification is proposed in this paper. The support vector data description (SVDD) and relevance vector machine (RVM) optimized by the artificial bee colony (ABC) are used for the steady-state identification and fault diagnosis. The density-based spatial clustering of applications with noise (DBSCAN) and linear least squares fitting (LLSF) are used to identify the abnormal data in datasets and estimate change rates of the system state variables respectively. The proposed method can automatically identify the state variable data collected from the PEMFC system during the stack switching between different operating points, so that the diagnosis accuracy can be improved and false alarms can be reduced. The proposed method has a certain practical value and can provide a reference for further study.


  • Open Access

    Hydrogen Leakage Diagnosis for Proton Exchange Membrane Fuel Cell Systems: Methods and Suggestions on Its Application in Fuel Cell Vehicles

    by Ying Tian, Qiang Zou, Zezhao Lin

    Proton exchange membrane fuel cell vehicles using hydrogen as fuel has become one of the key development directions in the field of new energy vehicles. However, hydrogen is flammable, it is easy to trigger serious safety accidents once hydrogen leak occurs. Therefore, the application of hydrogen leakage diagnosis methods is essential for the safe operation of proton exchange membrane fuel cell system. This paper reviews the existing methods of diagnosing hydrogen leakage for proton exchange membrane fuel cell system. The principles, research status and application scopes of different methods are elaborated, and these methods are analyzed based on three aspects of on-line diagnosis, real-time performance and calculation complexity. Furthermore, suggestions are provided for the selection of on-line hydrogen leakage diagnosis methods for fuel cell vehicles. Based on this review, readers can easily understand the current status of hydrogen leakage diagnosis methods for proton exchange membrane fuel cell system, and it can provide references for the application selection of the hydrogen leakage diagnosis methods for fuel cell vehicles.


  • Open Access

    Research on the Fault Diagnosis of a Polymer Electrolyte Membrane Fuel Cell System

    by Feng Han, Ying Tian, Qiang Zou, Xin Zhang

    In this work, the possibilistic fuzzy C-means clustering artificial bee colony support vector machine (PFCM-ABC-SVM) method is proposed and applied for the fault diagnosis of a polymer electrolyte membrane (PEM) fuel cell system. The innovation of this method is that it can filter data with Gaussian noise and diagnose faults under dynamic conditions, and the amplitude of characteristic parameters is reduced to ±10%. Under dynamic conditions with Gaussian noise, the faults of the PEM fuel cell system are simulated and the original dataset is established. The possibilistic fuzzy C-means (PFCM) algorithm is used to filter samples with membership and typicality less than 90% and to optimize the original dataset. The artificial bee colony (ABC) algorithm is used to optimize the penalty factor C and kernel function parameter g. Finally, the optimized support vector machine (SVM) model is used to diagnose the faults of the PEM fuel cell system. To illustrate the results of the fault diagnosis, a nonlinear PEM fuel cell simulator model which has been presented in the literature is used. In addition, the PFCM-ABC-SVM method is compared with other methods. The result shows that the method can diagnose faults in a PEM fuel cell system effectively and the accuracy of the testing set sample is up to 98.51%. When solving small-sized, nonlinear, high-dimensional problems, the PFCM-ABC-SVM method can improve the accuracy of fault diagnosis.