APAna Palazon-Cabanes

Ana Palazon-Cabanes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ana Palazon-Cabanes has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the Diagnostic Capability of Spectralis SD-OCT 8 × 8 Posterior Pole Software with the Grid Tilted at 7 Degrees and Horizontalized in Glaucoma

    by Aurora Alvarez-Sarrion, Jose Javier Garcia-Medina, Ana Palazon-Cabanes, Maria Dolores Pinazo-Duran, Monica Del-Rio-Vellosillo

    Background: The goal was to evaluate the diagnostic capability of different parameters obtained with the posterior pole (PP) software in Spectralis SD-OCT with the 8 × 8 grid tilted at 7° and horizontalized in glaucomatous eyes. Methods: A total of 299 eyes were included, comprising 136 healthy eyes and 163 with primary open-angle glaucoma (POAG). The following segmentations were evaluated: complete retina, retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), GCL and inner plexiform layer (GCLIPL), ganglion cell complex (GCC), outer plexiform layer and outer nuclear layer (OPLONL), inner retinal layer (IRL), and outer retinal layer (ORL). Different patterns of macular damage were represented using heatmaps for each studied layer, where the areas under the curve (AUROC) values and a retinal thickness cutoff point were defined to discriminate POAG patients. Results: There was not any difference in the diagnostic capability for detecting glaucoma between the grid tilted at 7° and horizontalized. The macular segmentations that offer the highest diagnostic ability in glaucoma discrimination were, in the following order, RNFL (AUROC = 0.796), GCC (AUROC = 0.785), GCL (AUROC = 0.784), GCLIPL (AUROC = 0.770), IRL (AUROC = 0.755), and the complete retina (AUROC = 0.752). In contrast, ORL and OPLONL do not appear to be helpful for discriminating POAG. Conclusions: Some results of PP software may be useful for discriminating POAG.


  • Open Access

    Normative Database of the Superior–Inferior Thickness Asymmetry for All Inner and Outer Macular Layers of Adults for the Posterior Pole Algorithm of the Spectralis SD-OCT

    by Ana Palazon-Cabanes, Begoña Palazon-Cabanes, Jose Javier Garcia-Medina, Aurora Alvarez-Sarrion, Monica Del-Rio-Vellosillo

    Background: This study aims to establish a reference for the superior–inferior hemisphere asymmetry in thickness values for all macular layers for the posterior pole algorithm (PPA) available for the Spectralis SD-OCT device. Methods: We examined 300 eyes of 300 healthy Caucasian volunteers aged 18–84 years using the PPA, composed of a grid of 64 (8 × 8) cells, to analyze the thickness asymmetries of the following automatically segmented macular layers: retinal nerve fiber layer (RNFL); ganglion cell layer (GCL); inner plexiform layer (IPL); inner nuclear layer (INL); outer plexiform layer (OPL); outer nuclear layer (ONL); retinal pigment epithelium (RPE); inner retina; outer retina; complete retina. Mean ± standard deviation and the 2.5th and 97.5th percentiles of the thickness asymmetry values were obtained for all the corresponding cells. Results: All the macular layers had significant superior–inferior thickness asymmetries. GCL, IPL, INL, ONL and RPE showed significantly greater thicknesses in the superior than the inferior hemisphere, whereas RNFL and OPL were thicker in the inferior hemisphere. The largest differences between hemispheres were for RNFL and ONL. Conclusions: This is the first normative database of macular thickness asymmetries for the PPA and should be considered to distinguish normal from pathological values when interpreting superior–inferior macular asymmetries.


  • Amblyopia due a dentigerous cyst. Case report and literature review

    by M.J. Quiroz-Quiroga, H. González Valdivia, A. Palazón Cabanes, J. Rubio Palau, J. Prat Bartomeu


  • Open Access

    Normative Database for All Retinal Layer Thicknesses Using SD-OCT Posterior Pole Algorithm and the Effects of Age, Gender and Axial Lenght

    by Ana Palazon-Cabanes, Begoña Palazon-Cabanes, Elena Rubio-Velazquez, Maria Dolores Lopez-Bernal, Jose Javier Garcia-Medina, Maria Paz Villegas-Perez

    Our aim was to provide, for the first time, reference thickness values for the SD-OCT posterior pole algorithm (PPA) available for Spectralis OCT device (Heidelberg Engineering, Heidelberg, Germany) and to analyze the correlations with age, gender and axial length. We recruited 300 eyes of 300 healthy Caucasian subjects between 18 and 84 years. By PPA, composed of 64 (8 × 8) cells, we analyzed the thickness of the following macular layers: retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigment epithelium (RPE), inner retina, outer retina and full retina. Mean ± SD, 1st, 5th, 95th percentiles were obtained for each cell at all macular layers. Significant negative correlations were found between age and thickness for most macular layers. The mean thickness of most macular layers was thicker for men than women, except for RNFL, OPL and RPE, with no gender differences. GCL, IPL and INL thicknesses positively correlated with axial length in central cells, and negatively in the cells near the optic disk. The mean RNFL thickness was positively associated with axial length. This is the first normative database for PPA. Age, gender and axial length should be taken into account when interpreting PPA results.


  • Open Access

    Glaucomatous Maculopathy: Thickness Differences on Inner and Outer Macular Layers between Ocular Hypertension and Early Primary Open-Angle Glaucoma Using 8 × 8 Posterior Pole Algorithm of SD-OCT

    by Jose Javier Garcia-Medina, Monica Del-Rio-Vellosillo, Ana Palazon-Cabanes, Maria Dolores Pinazo-Duran, Vicente Zanon-Moreno, Maria Paz Villegas-Perez

    The purpose of this study was to compare the thickness of all inner and outer macular layers between ocular hypertension (OHT) and early primary open-angle glaucoma (POAG) using spectral domain optical coherence tomography (SD-OCT) 8 × 8 posterior pole algorithm (8 × 8 PPA). Fifty-seven eyes of 57 OHT individuals and fifty-seven eyes of 57 early POAG patients were included. The thickness of macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform and nuclear layer, photoreceptor layer (PRL) and retinal pigment epithelium were obtained in 64 cells for each macular layer and mean thickness of superior and inferior hemispheres was also calculated. Thinning of superior and inferior hemisphere mean thickness in mRNFL, GCL and IPL and thickening of superior and inferior hemisphere mean thickness in PRL and inferior hemisphere in INL were found in early GPAA group. Otherwise, heatmaps representing cell-to-cell comparisons showed thinning patterns in inner retinal layers (except for INL) and thickening patterns in outer retinal layers in GPAA group. We found that 8 × 8 PPA not only allows the detection of significant thinning patterns in inner retinal layers, but also thickening patterns in outer retinal layers when comparing early POAG eyes to OHT eyes.