Jie Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jie Deng has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Junchi Liu
Medical Imaging Research Center and Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA 60616
2 shared publicationsMark P. Supanich
2 shared publications- Yunan Wu
Northwestern University
2 shared publications Gregory M. White
Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Chicago, IL, USA
1 shared publication- Gregory White
Department of Radiology, Rush University Medical Center, Chicago, IL, USA
1 shared publication Indraneel Gowdar
Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Chicago, IL, USA
1 shared publication
Latest Publications
- Open Access
Image-based Motion Artifact Reduction on Liver Dynamic Contrast Enhanced MRI
Liver MRI images often suffer degraded quality from ghosting or blurring artifact caused by patient respiratory or bulk motion. In this study, we developed a two-stage deep learning model to reduce motion artifact on dynamic contrast enhanced (DCE) liver MRIs. The stage-I network utilized a deep residual network with a densely connected multi-resolution block (DRN-DCMB) network to remove the majority of motion artifacts. The stage-II network applied the perceptual loss to preserve image structural features by updating the parameters of the stage-I network via backpropagation. The stage-I network was trained using small image patches simulated with five types of motion, i.e., rotational, sinusoidal, random, elastic deformation and through-plane, to mimic actual liver motion patterns. The stage-II network training used full-size images with the same types of motion as the stage-I network. The motion reduction deep learning model was testing using simulated motion images and images with real motion artifacts. The resulted images after two-stage processing demonstrated substantially reduced motion artifacts while preserved anatomic details without image blurriness. This model outperformed existing methods of motion reduction artifact on liver DCE-MRI.
Open AccessImage-based Motion Artifact Reduction on Liver Dynamic Contrast Enhanced MRI
Liver MRI images often suffer degraded quality from ghosting or blurring artifact caused by patient respiratory or bulk motion. In this study, we developed a two-stage deep learning model to reduce motion artifact on dynamic contrast enhanced (DCE) liver MRIs. The stage-I network utilized a deep residual network with a densely connected multi-resolution block (DRN-DCMB) network to remove the majority of motion artifacts. The stage-II network applied the perceptual loss to preserve image structural features by updating the parameters of the stage-I network via backpropagation. The stage-I network was trained using small image patches simulated with five types of motion, i.e., rotational, sinusoidal, random, elastic deformation and through-plane, to mimic actual liver motion patterns. The stage-II network training used full-size images with the same types of motion as the stage-I network. The motion reduction deep learning model was testing using simulated motion images and images with real motion artifacts. The resulted images after two-stage processing demonstrated substantially reduced motion artifacts while preserved anatomic details without image blurriness. This model outperformed existing methods of motion reduction artifact on liver DCE-MRI.
- Open Access
- 1 January 2021
- Published by Nexus Press B. V. in Journal of Artificial Intelligence for Medical Sciences
- Vol. 2 (1-2) , 12-20
Ensembled Deep Neural Network for Intracranial Hemorrhage Detection and Subtype Classification on Noncontrast CT Images
Rapid and accurate diagnosis of intracranial hemorrhage is clinically significant to ensure timely treatment. In this study, we developed an ensembled deep neural network for the detection and subtype classification of intracranial hemorrhage. The model consisted of two parallel network pathways, one using three different window level/width settings to enhance the image contrast of brain, blood, and soft tissue. The other extracted spatial information of adjacent image slices to the target slice. Both pathways exploited the EfficientNet-B0 as the basic architecture and were ensembled to generate the final prediction. Class activation mapping was applied in both pathways to highlight the regions of detected hemorrhage and the associated subtypes. The model was trained and tested using Intracranial Hemorrhage Detection Challenge (IHDC) dataset launched by the Radiological Society of North America (RSNA) in 2019, which contained 674,258 head noncontrasts computer tomography images acquired from 19,530 patients. An independent dataset (CQ500) acquired from another institution was used to test the generalizability of the trained model. The overall accuracy, sensitivity, and F1 score for intracranial hemorrhage detection were 95.7%, 85.9%, and 86.7% on IHDC testing dataset and 92.4%, 92.6%, and 93.4% on external CQ500 testing dataset. The heatmaps by class activation mapping successfully demonstrated discriminative feature regions of the predicted hemorrhage locations and subtypes, providing visual guidance for radiologists to assist in rapid diagnosis of intracranial hemorrhage.
- 1 January 2021
- Published by Nexus Press B. V. in Journal of Artificial Intelligence for Medical Sciences
- Vol. 2 (1-2) , 12-20
Open AccessEnsembled Deep Neural Network for Intracranial Hemorrhage Detection and Subtype Classification on Noncontrast CT Images
Rapid and accurate diagnosis of intracranial hemorrhage is clinically significant to ensure timely treatment. In this study, we developed an ensembled deep neural network for the detection and subtype classification of intracranial hemorrhage. The model consisted of two parallel network pathways, one using three different window level/width settings to enhance the image contrast of brain, blood, and soft tissue. The other extracted spatial information of adjacent image slices to the target slice. Both pathways exploited the EfficientNet-B0 as the basic architecture and were ensembled to generate the final prediction. Class activation mapping was applied in both pathways to highlight the regions of detected hemorrhage and the associated subtypes. The model was trained and tested using Intracranial Hemorrhage Detection Challenge (IHDC) dataset launched by the Radiological Society of North America (RSNA) in 2019, which contained 674,258 head noncontrasts computer tomography images acquired from 19,530 patients. An independent dataset (CQ500) acquired from another institution was used to test the generalizability of the trained model. The overall accuracy, sensitivity, and F1 score for intracranial hemorrhage detection were 95.7%, 85.9%, and 86.7% on IHDC testing dataset and 92.4%, 92.6%, and 93.4% on external CQ500 testing dataset. The heatmaps by class activation mapping successfully demonstrated discriminative feature regions of the predicted hemorrhage locations and subtypes, providing visual guidance for radiologists to assist in rapid diagnosis of intracranial hemorrhage.
- 1 September 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 71, 69-79
Motion artifacts reduction in brain MRI by means of a deep residual network with densely connected multi-resolution blocks (DRN-DCMB)
- 1 September 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 71, 69-79
Motion artifacts reduction in brain MRI by means of a deep residual network with densely connected multi-resolution blocks (DRN-DCMB)
- Open Access
- 1 June 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (11) , 701
Deep learning LI-RADS grading system based on contrast enhanced multiphase MRI for differentiation between LR-3 and LR-4/LR-5 liver tumors
Background: To develop a deep learning (DL) method based on multiphase, contrast-enhanced (CE) magnetic resonance imaging (MRI) to distinguish Liver Imaging Reporting and Data System (LI-RADS) grade 3 (LR-3) liver tumors from combined higher-grades 4 and 5 (LR-4/LR-5) tumors for hepatocellular carcinoma (HCC) diagnosis. Methods: A total of 89 untreated LI-RADS-graded liver tumors (35 LR-3, 14 LR-4, and 40 LR-5) were identified based on the radiology MRI interpretation reports. Multiphase 3D T1-weighted gradient echo imaging was acquired at six time points: pre-contrast, four phases immediately post-contrast, and one hepatobiliary phase after intravenous injection of gadoxetate disodium. Image co-registration was performed across all phases on the center tumor slice to correct motion. A rectangular tumor box centered on the tumor area was drawn to extract subset tumor images for each imaging phase, which were used as the inputs to a convolutional neural network (CNN). The pre-trained AlexNet CNN model underwent transfer learning using liver MRI data for LI-RADS tumor grade classification. The output probability number closer to 1 or 0 indicated a higher possibility of being combined LR-4/LR-5 tumor or LR-3 tumor, respectively. Five-fold cross validation was used for training (60% dataset), validation (20%) and testing processes (20%). Results: The DL CNN model for LI-RADS grading using inputs of multiphase liver MRI data acquired at three time points (pre-contrast, arterial, and washout phase) achieved a high accuracy of 0.90, sensitivity of 1.0, precision of 0.835, and AUC of 0.95 with reference to the expert human radiologist report. The CNN output of probability provided radiologists a confidence level of the model’s grading for each liver lesion. Conclusions: An AlexNet CNN model for LI-RADS grading of liver lesions provided diagnostic performance comparable to radiologists and offered valuable clinical guidance for differentiating intermediate LR-3 liver lesions from more-likely malignant LR-4/LR-5 lesions in HCC diagnosis.
- 1 June 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (11) , 701
Open AccessDeep learning LI-RADS grading system based on contrast enhanced multiphase MRI for differentiation between LR-3 and LR-4/LR-5 liver tumors
Background: To develop a deep learning (DL) method based on multiphase, contrast-enhanced (CE) magnetic resonance imaging (MRI) to distinguish Liver Imaging Reporting and Data System (LI-RADS) grade 3 (LR-3) liver tumors from combined higher-grades 4 and 5 (LR-4/LR-5) tumors for hepatocellular carcinoma (HCC) diagnosis. Methods: A total of 89 untreated LI-RADS-graded liver tumors (35 LR-3, 14 LR-4, and 40 LR-5) were identified based on the radiology MRI interpretation reports. Multiphase 3D T1-weighted gradient echo imaging was acquired at six time points: pre-contrast, four phases immediately post-contrast, and one hepatobiliary phase after intravenous injection of gadoxetate disodium. Image co-registration was performed across all phases on the center tumor slice to correct motion. A rectangular tumor box centered on the tumor area was drawn to extract subset tumor images for each imaging phase, which were used as the inputs to a convolutional neural network (CNN). The pre-trained AlexNet CNN model underwent transfer learning using liver MRI data for LI-RADS tumor grade classification. The output probability number closer to 1 or 0 indicated a higher possibility of being combined LR-4/LR-5 tumor or LR-3 tumor, respectively. Five-fold cross validation was used for training (60% dataset), validation (20%) and testing processes (20%). Results: The DL CNN model for LI-RADS grading using inputs of multiphase liver MRI data acquired at three time points (pre-contrast, arterial, and washout phase) achieved a high accuracy of 0.90, sensitivity of 1.0, precision of 0.835, and AUC of 0.95 with reference to the expert human radiologist report. The CNN output of probability provided radiologists a confidence level of the model’s grading for each liver lesion. Conclusions: An AlexNet CNN model for LI-RADS grading of liver lesions provided diagnostic performance comparable to radiologists and offered valuable clinical guidance for differentiating intermediate LR-3 liver lesions from more-likely malignant LR-4/LR-5 lesions in HCC diagnosis.