AKAnna N. Khoruzhaya

Anna N. Khoruzhaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anna N. Khoruzhaya has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the clinical applicability of artificial intelligence systems for detecting infiltrative changes on chest x-rays in inpatient care

    by R. A. Erizhokov, P. A. Sakharova, V. V. Kirsanov, A. N. Khoruzhaya, M. D. Varyukhina, K. M. Arzamasov, A. V. Vladzymyrskyy, Y. A. Vasilev

    Aim: to investigate the capabilities of artificial intelligence systems (AIS) in an inpatient setting, specifically in identifying signs of infiltration in chest radiographs (RG OGK). Materials and methods. The initial data were chest X-rays (CXRs) in a frontal projection of 1,537 inpatients aged 18 to 102 years, obtained from the Unified Radiological Information System of the Unified Medical Information and Analytical Service (ERIS EMIAS). The presence of infiltration on the chest X-ray was determined by a radiologist (Radiologist 1) and an expert radiologist (Radiologist 2) with more than 5 years of experience. Radiologist 2 annotated the studies in two stages: at the first stage, only the chest X-rays were provided; at the second stage, in addition to the radiological data, access to information about the patient’s condition was provided. Results. The accuracy rates for patients with a shifting state were 0.755 for AIS, 0.756 for Radiologist 1, and 0.856 for Radiologist 2, respectively. No statistically significant differences in accuracy were found between AIS and Radiologist 1 (p>0.05). When considering the scenario of using the AIS as a second opinion the accuracy for patients with a shifting state was 0.833, which is statistically significantly higher than the accuracy of Radiologist 1 and the AIS (pConclusion. AIS can be used as a second opinion when detecting signs of infiltration based on RG OGK data in a hospital setting. However, since the diagnostic accuracy of the AIS is still insufficient for practical use, further research is needed to train algorithms using both visual data and electronic medical record data.

  • Open Access

    MosMedReg Subtraction Software effectiveness in Multiple Sclerosis Diagnosis Using Magnetic Resonance Imaging Data

    by E. I. Kremneva, D. S. Semenov, A. K. Smorchkova, A. N. Khoruzhaya, D. V. Kuligovskiy, N. D. Adamia, R. A. Erizhokov, O. V. Omelyanskaya, A. V. Vladzymyrskyy, Yu. A. Vasilev

    The aim of this study was to evaluate the effectiveness of the automated MosMedReg software for subtraction analysis of longitudinal brain MRI in patients with multiple sclerosis in a routine outpatient setting. The study included 30 paired MRI examinations performed on 1.5 T scanners from different manufacturers using T2, FLAIR, and contrast-enhanced T1 sequences with variable slice thicknesses. Image processing was performed using registration and subtraction algorithms based on the SimpleElastix library. Images were assessed manually by an expert and with the assistance of the software; results were evaluated using clinical and technical scoring systems. The software provided successful registration and subtraction in all cases, including series different in slice thickness and projections. The average number of newly identified lesions using MosMedReg did not differ from expert assessment (p = 0.25); however, in several cases, subtraction enabled the detection of clinically significant changes that were not observed in standard analysis. False-positive findings associated with technical artifacts due to scan parameter mismatches were also noted. The results confirm the reproducibility and practical applicability of subtraction analysis with MosMedReg for improving the objectivity and standardization of multiple sclerosis diagnosis in outpatient practice.

  • Open Access

    MEDAI-LLM-SUMM: a reporting checklist for medical text summarization studies using large language models

    by Anna N. Khoruzhaya, Mariya D. Varyukhina, Rustam A. Erizhokov, Ivan A. Blokhin, Roman V. Reshetnikov, Mariya R. Kodenko, Anastasia P. Pamova, Tikhon A. Burtsev, Kirill M. Arzamasov, Olga V. Omelyanskaya, et al.

    Background: Medical text summarization using large language models (LLMs) has reached an inflection point in 2024–2025, with adapted models demonstrating capability to match or exceed human expert performance in specific tasks. However, critical gaps persist in safety validation, evaluation frameworks, and clinical deployment readiness. A comprehensive review revealed that only 7% of studies conducted external validation and 3% performed patient safety assessments, with hallucination rates ranging from 1.47% to 61.6%. Existing reporting guidelines, including CONSORT-AI, SPIRIT-AI, TRIPOD-LLM, and DEAL, do not adequately address the specific requirements of medical text summarization tasks. Objective: to develop MEDAI-LLM-SUMM, the first specialized reporting checklist for research on medical text summarization using LLMs, addressing critical gaps in existing reporting standards. Methods: A modified iterative consensus approach was employed, comprising three sequential stages: (1) a systematic literature review of 216 publications from PubMed and eLibrary (2023–2025) following PRISMA guidelines and an analysis of existing reporting standards (TRIPOD-LLM, DEAL, CONSORT-AI, SPIRIT-AI, TRIPOD + AI, CLAIM, STARD-AI); (2) development of an initial 44-item, 7-section checklist by a supervisory group; (3) three rounds of face-to-face consensus discussions with a multidisciplinary expert panel of 11 specialists (3 radiologists, 2 clinicians, 3 medical informatics experts, 1 biostatistician, and 2 medical LLM developers). The consensus criterion required unanimous agreement from all panel members. Results: The final MEDAI-LLM-SUMM checklist comprises 24 items organized into six sections: (A) Clinical validity (4 items addressing clinical task definition, expert involvement, hypothesis formulation, and medical expertise requirements); (B) Model Selection (5 items covering model justification, system requirements, deployment environment, LLM-as-judge approach, and prompt documentation); (C) Data (3 items on datasets, reference summaries with expert consensus, and data stratification); (D) Quality Assessment (8 items including evaluation metrics, clinical metrics, expert evaluation, hallucination detection, LLM-judge assessment, sample size justification, pilot testing, and limitations documentation); (E) Safety (2 items on ethical approval and data anonymization); and (F) Data Availability (2 items on code and dataset accessibility). Comparative analysis with six existing reporting standards demonstrated that MEDAI-LLM-SUMM uniquely addresses hallucination assessment requirements, reference summary creation methodology, LLM-as-judge validation protocols, and detailed pilot testing specifications.


  • Open Access

    Standalone AI Versus AI-Assisted Radiologists in Emergency ICH Detection: A Prospective, Multicenter Diagnostic Accuracy Study

    by Anna N. Khoruzhaya, Polina A. Sakharova, Kirill M. Arzamasov, Elena I. Kremneva, Dmitriy V. Burenchev, Rustam A. Erizhokov, Olga V. Omelyanskaya, Anton V. Vladzymyrskyy, Yuriy A. Vasilev

    Background/Objectives. Intracranial hemorrhages (ICHs) require immediate diagnosis for optimal clinical outcomes. Artificial intelligence (AI) is considered a potential solution for optimizing neuroimaging under conditions of radiologist shortage and increasing workload. This study aimed to directly compare diagnostic effectiveness between standalone AI services and AI-assisted radiologists in detecting ICHs on brain CT. Methods. A prospective, multicenter comparative study was conducted in 67 medical organizations in Moscow over 15+ months (April 2022–December 2024). We analyzed 3409 brain CT studies containing 1101 ICH cases (32.3%). Three commercial AI services with state registration were compared with radiologist conclusions formulated with access to AI results as auxiliary tools. Statistical analysis included McNemar’s test for paired data and Cohen’s h effect size analysis. Results. Radiologists with AI assistance statistically significantly outperformed AI services across all diagnostic metrics (p < 0.001): sensitivity 98.91% vs. 95.91%, specificity 99.83% vs. 87.35%, and accuracy 99.53% vs. 90.11%. The radiologists’ diagnostic odds ratio exceeded that of AI by 323-fold. The critical difference was in false-positive rates: 293 cases for AI vs. 4 for radiologists (73-fold increase). Complete complementarity of ICH misses was observed: all 12 cases undetected by radiologists were identified by AI, while all 45 cases missed by AI were diagnosed by radiologists. Agreement between methods was 89.6% (Cohen’s kappa 0.776). Conclusions. Radiologists maintain their role as the gold standard in ICH diagnosis, significantly outperforming AI services. Error complementarity indicates potential for improvement through systematic integration of AI as a “second reader” rather than a primary diagnostic tool. However, the high false-positive rate of standalone AI requires substantial algorithm refinement. The optimal implementation strategy involves using AI as an auxiliary tool within radiologist workflows rather than as an autonomous diagnostic system, with potential for delayed verification protocols to maximize diagnostic sensitivity while managing the false-positive burden.


  • Open Access

    The impact of brain computed tomography metadata on the performance of diagnostic artificial intelligence services: a pilot study

    by A. N. Khoruzhaya, D. V. Kuligovskiy, Yu. A. Vasilev

    The aim of the study is to evaluate the impact of metadata added to the training dataset on the performance of an artificial intelligence system aimed at working with diagnostic brain images. Material and Methods. An expanded set of computed tomography scans of the brain with and without signs of intracranial haemorrhage, supplemented with clinical and technical parameters, was used as a basis. From the dataset, 176 studies were selected (106 for training, 70 for testing), which were specially prepared for input into the neural network: they were segmented with the region of interest (the brain) highlighted, normalized, and the background was removed. The ResNet10 neural network architecture, which is capable of analyzing 3D medical images, was used as the underlying neural network. It was combined with another neural network to form the ResNet10_Meta architecture, which, using a One-HotEnconding (OHE) approach, connects other metadata to analyze images directly. Four parameters were selected as metadata: ‘Manufacturer’, ‘SliceThickness’, ‘PatientAge’, and ‘XrayTubeCurrent’. Results. Twelve experiments were conducted to train the neural network with one, two, or all of the additional parameters added alternately. The model with the addition of the ‘XTube’ parameter showed the highest specificity (82.3 %, 95 % confidence interval (95 % CI) [69.6–94.9]), outperforming the Baseline model without additional metadata (specificity 79.4 %, 95 % CI [66.0–92.8]). The ‘XTube + SliceT’ model with the addition of multiple metadata showed comparatively higher sensitivity (69.7 %, 95 % CI [54.5–84.9]) relative to Baseline model. The model with the addition of all metadata ‘All params’ did not show significant improvements. However, all differences found were statistically insignificant (p > 0.05). Conclusions. Our data demonstrated that there were no statistically significant differences in the performance of a neural network analyzing diagnostic images without or with metadata added to the training dataset. However, this study is pilot and was conducted on a limited sample, so it remains to be seen whether commercially available artificial intelligence tools can be completely insensitive to image specifications.

  • Open Access

    Predictors of morphofunctional features of somatotrophic tumors and of the effectiveness of treatment with first-generation somatostatin receptor ligands

    by E. V. Pronin, V. S. Pronin, M. B. Antsiferov, A. V. Petryaykin, T. M. Alexeeva, A. M. Lapshina, L. S. Urusova, A. N. Khoruzhaya, S. M. Tamaeva

    Introduction. Timely differential diagnosis between densely and sparsely granulated somatotrophic tumors allows predicting the most probable scenario of acromegaly course, receptor phenotype and proliferative potential of tumor cells, risk of continued postoperative growth, as well as the efficacy of planned drug therapy with first-generation somatostatin receptor ligands.Aim. To validate cytological, radiological and therapeutic predictors allowing to evaluate the morphofunctional composition of somatotrophic tumors and to predict sensitivity to first-generation somatostatin receptor ligands.Materials and methods. 525 patients (153 men) aged 60.2 ± 14.0 years receiving drug therapy with first-generation somatostatin receptor ligands for 72.0 ± 51.9 months were examined.Results. Treatment efficacy was evaluated according to the final level of IGF-1 index (≤1) and compared with the data of pathomorphologic (97 patients) and repeated radiologic (53 patients) examination. The influence of cellular composition of densely and sparsely granulated somatotrophic tumors on immunohistochemical and radiologic characteristics with the designation of leading predictors of morphologic identification of somatotrophic tumors was investigated. Additional radio markers for quantitative assessment of relative intensity of tumor signal on T2-, T1and (T2-T1)-weighted MRI for non-invasive differential diagnostics of densely and sparsely granulated somatotrophic tumors and determination of optimal treatment tactics were proposed. The expediency of using pharmacotherapeutic testing with short-term (3–6 months) first-generation somatostatin receptor ligands administration to assess the intactness of receptor and postreceptor mechanisms and to choose optimal drug therapy was substantiated.Conclusion. The precision approach based on comprehensive clinical, radiological, pathomorphological and functional characteristics allows stratification of patients with acromegaly to optimize treatment benefit. Achievement of acromegaly control in drug therapy with first-generation somatostatin receptor ligands depends on tumor volume and its hormonal activity, absolute and relative expression of the 2nd subtype of somatostatin receptors, severity of destructive changes and features of cellular composition. In case of refractoriness to first-generation somatostatin receptor ligands, the use of pegvisomant is expedient.


  • Open Access

    Comparison of an Ensemble of Machine Learning Models and the BERT Language Model for Analysis of Text Descriptions of Brain CT Reports to Determine the Presence of Intracranial Hemorrhage

    by A.N. Khoruzhaya, D.V. Kozlov, K.M. Arzamasov, E.I. Kremneva

    The aim of this study is to train and test an ensemble of machine learning models, as well as to compare its performance with the BERT language model pre -trained on medical data to perform simple binary classification, i.e., determine the presence/absence of the signs of intracranial hemorrhage (ICH) in brain CT reports. Materials and Methods. Seven machine learning algorithms and three text vectorization techniques were selected as models to solve the binary classification problem. These models were trained on textual data represented by 3980 brain CT reports from 56 inpatient medical facilities in Moscow. The study utilized three text vectorization techniques: bag of words, TF-IDF, and Word2Vec. The resulting data were then processed by the following machine learning algorithms: decision tree, random forest, logistic regression, nearest neighbors, support vector machines, Catboost, and XGboost. Data analysis and pre-processing were performed using NLTK (Natural Language Toolkit, version 3.6.5), libraries for character -based and statistical processing of natural language, and Scikit-learn (version 0.24.2), a library for machine learning containing tools to tackle classification challenges. MedRuBertTiny2 was taken as a BERT transformer model pre -trained on medical data. Results. Based on the training and testing outcomes from seven machine learning algorithms, the authors selected three algorithms that yielded the highest metrics (i.e. sensitivity and specificity): CatBoost, logistic regression, and nearest neighbors. The highest metrics were achieved by the bag of words technique. These algorithms were assembled into an ensemble using the stacking technique. The sensitivity and specificity for the validation dataset separated from the original sample were 0.93 and 0.90, respectively. Next, the ensemble and the BERT model were trained on an independent dataset containing 9393 textual radiology reports also divided into training and test sets. Once the ensemble was tested on this dataset, the resulting sensitivity and specificity were 0.92 and 0.90, respectively. The BERT model tested on these data demonstrated a sensitivity of 0.97 and a specificity of 0.90. Conclusion. When analyzing textual reports of brain CT scans with signs of intracranial hemorrhage, the trained ensemble demonstrated high accuracy metrics. Still, manual quality control of the results is required during its application. The pre -trained BERT transformer model, additionally trained on diagnostic textual reports, demonstrated higher accuracy metrics (p<0.05). The results show promise in terms of finding specific values for both binary classification task and in-depth analysis of unstructured medical information.


  • Open Access

    Expanded Brain CT Dataset for the Development of AI Systems for Intracranial Hemorrhage Detection and Classification

    by Anna N. Khoruzhaya, Tatiana M. Bobrovskaya, Dmitriy V. Kozlov, Dmitriy Kuligovskiy, Vladimir P. Novik, Kirill M. Arzamasov, Elena I. Kremneva

    Intracranial hemorrhage (ICH) is a dangerous life-threatening condition leading to disability. Timely and high-quality diagnosis plays a huge role in the course and outcome of this disease. The gold standard in determining ICH is computed tomography. This method requires a prompt involvement of highly qualified personnel, which is not always possible, for example, in case of a staff shortage or increased workload. In such a situation, every minute counts, and time can be lost. The solution to this problem seems to be a set of diagnostic decisions, including the use of artificial intelligence, which will help to identify patients with ICH in a timely manner and provide prompt and quality medical care. However, the main obstacle to the development of artificial intelligence is a lack of high-quality datasets for training and testing. In this paper, we present a dataset including 800 brain CT scans consisting of multiple series of DICOM images with and without signs of ICH, enriched with clinical and technical parameters, as well as the methodology of its generation utilizing natural language processing tools. The dataset is publicly available, which contributes to increased competition in the development of artificial intelligence systems and their advancement and quality improvement.


  • Open Access

    Routine Brain MRI Findings on the Long-Term Effects of COVID-19: A Scoping Review

    by Yuriy Vasilev, Ivan Blokhin, Anna Khoruzhaya, Maria Kodenko, Vasiliy Kolyshenkov, Olga Nanova, Yuliya Shumskaya, Olga Omelyanskaya, Anton Vladzymyrskyy, Roman Reshetnikov

    Rationale and Objectives: Post-COVID condition (PCC) is associated with long-term neuropsychiatric symptoms. Magnetic resonance imaging (MRI) in PCC examines the brain metabolism, connectivity, and morphometry. Such techniques are not easily available in routine practice. We conducted a scoping review to determine what is known about the routine MRI findings in PCC patients. Materials and Methods: The PubMed database was searched up to 11 April 2023. We included cohort, cross-sectional, and before–after studies in English. Articles with only advanced MRI sequences (DTI, fMRI, VBM, PWI, ASL), preprints, and case reports were excluded. The National Heart, Lung, and Blood Institute and PRISMA Extension tools were used for quality assurance. Results: A total of 7 citations out of 167 were included. The total sample size was 451 patients (average age 51 ± 8 years; 67% female). Five studies followed a single recovering cohort, while two studies compared findings between two severity groups. The MRI findings were perivascular spaces (47%), microbleeds (27%) and white matter lesions (10%). All the studies agreed that PCC manifestations are not associated with specific MRI findings. Conclusion: The results of the included studies are heterogeneous due to the low agreement on the types of MRI abnormalities in PCC. Our findings indicate that the routine brain MRI protocol has little value for long COVID diagnostics.


  • Recognition of text areas with personal data on diagnostic images

    by V. P. Novik, Н. С. Кульберг, K. M. Arzamasov, S. F. Chetverikov, A. N. Khoruzhaya, D. V. Kozlov, E. I. Kremneva

    The aim of the study is to develop a method for detecting areas of text with private data on medical diagnostic images using the Tesseract module and the modified Levenshtein distance. Materials and methods. For threshold filtering, the brightness of the points belonging to the text characters in the images is determined at the initial stage. The dynamic threshold is calculated from the histogram of the brightness of the pixels of the image. Next, the Tesseract module is used for primary text recognition. Based on the tag values from DICOM files, a set of strings was formed to search for them in the recognized text. A modified Levenshtein distance was used to search for these strings. A set of DICOM files of the “Dose Report” type was used to test the algorithm. The accuracy was assessed by experts marking up blocks of private information on images. Results. A tool has been developed with a set of metrics and optimal thresholds for choosing decisive rules in finding matches that allow detecting areas of text with private data on medical images. For this tool, the accuracy of localization of areas with personal data on a set of 1131 medical images was determined in comparison with expert markup, which is 99.86%. Conclusion. The tool developed within the framework of this study allows identifying personal data on digital medical images with high accuracy, which indicates the possibility of its practical application in the preparation of data sets.