Qing Sun
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qing Sun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Michael Y. Sha
Diacarta Inc
4 shared publications Aiguo Zhang
Affiliation DiaCarta, Inc., Richmond, California, United States of America
3 shared publicationsLarry Pastor
Affiliation DiaCarta, Inc., Richmond, California, United States of America
3 shared publications- Chuanyi Mark Lu
Department of Laboratory Medicine, University of California, San Francisco, San Francisco, CA 94143, USA
2 shared publications Hui Ren
Affiliation DiaCarta Inc., Richmond, California, United States of America
2 shared publicationsJonathan Li
Affiliation DiaCarta Inc., Richmond, California, United States of America
2 shared publications
Latest Publications
- Open Access
- 5 October 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (10) , e0244332
A novel xenonucleic acid-mediated molecular clamping technology for early colorectal cancer screening
Background: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape TM assay for early colorectal cancer diagnostics. Methods: Nineteen mutations in four genes (APC, KRAS, BRAF and CTNNB1) associated with early events in CRC pathogenesis are targeted in the ColoScapeTM assay. Xenonucleic Acid (XNA)-mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and an ROC curve was applied to evaluate its performance. Results: The data showed that the assay analytical sensitivity was 0.5% Variant Allele Frequency, corresponding to ~7–8 copies of mutant DNA with 5 ng total DNA input per test. This assay is highly reproducible with intra-assay CV of <3% and inter-assay CV of <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were: 100% (95% CI, 80.3–97.5%) and 92.2% (95% CI, 94.7–100%), respectively, with AUC of 0.96; 96% specificity (95% CI, 77.6–99.7%) and 92% sensitivity (95% CI, 86.1–95.6%) with AUC of 0.94 for CRC FFPE; 95% specificity (95% CI, 82.5%–99.1%) and 62.5% sensitivity (95% CI, 35.8%–83.7%) with AUC of 0.79 for precancerous lesions cfDNA. Conclusions: The XNA-mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.
- 5 October 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (10) , e0244332
Open AccessA novel xenonucleic acid-mediated molecular clamping technology for early colorectal cancer screening
Background: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape TM assay for early colorectal cancer diagnostics. Methods: Nineteen mutations in four genes (APC, KRAS, BRAF and CTNNB1) associated with early events in CRC pathogenesis are targeted in the ColoScapeTM assay. Xenonucleic Acid (XNA)-mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and an ROC curve was applied to evaluate its performance. Results: The data showed that the assay analytical sensitivity was 0.5% Variant Allele Frequency, corresponding to ~7–8 copies of mutant DNA with 5 ng total DNA input per test. This assay is highly reproducible with intra-assay CV of <3% and inter-assay CV of <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were: 100% (95% CI, 80.3–97.5%) and 92.2% (95% CI, 94.7–100%), respectively, with AUC of 0.96; 96% specificity (95% CI, 77.6–99.7%) and 92% sensitivity (95% CI, 86.1–95.6%) with AUC of 0.94 for CRC FFPE; 95% specificity (95% CI, 82.5%–99.1%) and 62.5% sensitivity (95% CI, 35.8%–83.7%) with AUC of 0.79 for precancerous lesions cfDNA. Conclusions: The XNA-mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.
- Open Access
Irrigable Measures for Weighted Irrigation Plans
A model of irrigation network, where lower branches must be thicker in order to support the weight of the higher ones, was recently introduced in BSUN2 [4]. This leads to a countable family of ODEs, describing the thickness of every branch, solved by backward induction. The present paper determines what kind of measures can be irrigated with a finite weighted cost. Indeed, the boundedness of the cost depends on the dimension of the support of the irrigated measure, and also on the asymptotic properties of the ODE which determines the thickness of branches.
Open AccessIrrigable Measures for Weighted Irrigation Plans
A model of irrigation network, where lower branches must be thicker in order to support the weight of the higher ones, was recently introduced in BSUN2 [4]. This leads to a countable family of ODEs, describing the thickness of every branch, solved by backward induction. The present paper determines what kind of measures can be irrigated with a finite weighted cost. Indeed, the boundedness of the cost depends on the dimension of the support of the irrigated measure, and also on the asymptotic properties of the ODE which determines the thickness of branches.
- Open Access
- 23 February 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (2) , e0243183
Saliva as a testing specimen with or without pooling for SARS-CoV-2 detection by multiplex RT-PCR test
Background: Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patients. Here we report the performance of QuantiVirus™ SARS-CoV-2 test using saliva as the testing specimens with or without pooling. Methods: Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical performance studies were performed with the QuantiVirus™ SARS-CoV-2 test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 test were also obtained and analyzed. Additionally, testing of pooled saliva samples was evaluated. Results: The LOD for the QuantiVirus™ SARS-CoV-2 test was confirmed to be 100–200 copies/mL. The clinical performance studies using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus™ SARS CoV-2 test had 80% concordance rate and no significant difference (p = 0.13) between paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from local communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples (1:6 pooling) for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%). Conclusion: The studies demonstrated that the QuantiVirus™ SARS-CoV-2 test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™ SARS-CoV-2 test offers a highly desirable testing platform during the ongoing COVID-19 pandemic.
- 23 February 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (2) , e0243183
Open AccessSaliva as a testing specimen with or without pooling for SARS-CoV-2 detection by multiplex RT-PCR test
Background: Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patients. Here we report the performance of QuantiVirus™ SARS-CoV-2 test using saliva as the testing specimens with or without pooling. Methods: Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical performance studies were performed with the QuantiVirus™ SARS-CoV-2 test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 test were also obtained and analyzed. Additionally, testing of pooled saliva samples was evaluated. Results: The LOD for the QuantiVirus™ SARS-CoV-2 test was confirmed to be 100–200 copies/mL. The clinical performance studies using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus™ SARS CoV-2 test had 80% concordance rate and no significant difference (p = 0.13) between paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from local communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples (1:6 pooling) for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%). Conclusion: The studies demonstrated that the QuantiVirus™ SARS-CoV-2 test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™ SARS-CoV-2 test offers a highly desirable testing platform during the ongoing COVID-19 pandemic.
- Open Access
Saliva as a testing specimen with or without pooling for SARS-CoV-2 detection by multiplex RT-PCR test
Background: Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patient. Here we report the performance of QuantiVirus™ SARS-CoV-2 multiplex test using saliva as the testing specimens with or without pooling. Methods: Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical evaluation studies were performed with the QuantiVirus™ SARS-CoV-2 multiplex test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 multiplex test were also obtained and analyzed. Moreover, saliva pooling with 6 and 12 samples together were also evaluated. Results: The LOD for the QuantiVirus™ SARS-CoV-2 multiplex test was confirmed to be 100-200 copies/mL. The clinical evaluation using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 multiplex test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 multiplex test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus ™SARS CoV-2 multiplex test had 80% concordance rate and no significant difference ( p =0.13) in paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from the communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%). Conclusion: The studies demonstrated that the QuantiVirus™ SARS-CoV-2 multiplex test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™SARS-CoV-2 multiplex test offers a highly desirable test during the ongoing COVID-19 pandemic.
Open AccessSaliva as a testing specimen with or without pooling for SARS-CoV-2 detection by multiplex RT-PCR test
Background: Sensitive and high throughput molecular detection assays are essential during the coronavirus disease 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The vast majority of the SARS-CoV-2 molecular assays use nasopharyngeal swab (NPS) or oropharyngeal swab (OPS) specimens collected from suspected individuals. However, using NPS or OPS as specimens has apparent drawbacks, e.g. the collection procedures for NPS or OPS specimens can be uncomfortable to some people and may cause sneezing and coughing which in turn generate droplets and/or aerosol particles that are of risk to healthcare workers, requiring heavy use of personal protective equipment. There have been recent studies indicating that self-collected saliva specimens can be used for molecular detection of SARS-CoV-2 and provides more comfort and ease of use for the patient. Here we report the performance of QuantiVirus™ SARS-CoV-2 multiplex test using saliva as the testing specimens with or without pooling. Methods: Development and validation studies were conducted following FDA-EUA and molecular assay validation guidelines. Using SeraCare Accuplex SARS-CoV-2 reference panel, the limit of detection (LOD) and clinical evaluation studies were performed with the QuantiVirus™ SARS-CoV-2 multiplex test. For clinical evaluation, 85 known positive and 90 known negative clinical NPS samples were tested. Additionally, twenty paired NPS and saliva samples collected from recovering COVID-19 patients were tested and the results were further compared to that of the Abbott m2000 SARS-CoV-2 PCR assay. Results of community collected 389 saliva samples for COVID-19 screening by QuantiVirus™ SARS-CoV-2 multiplex test were also obtained and analyzed. Moreover, saliva pooling with 6 and 12 samples together were also evaluated. Results: The LOD for the QuantiVirus™ SARS-CoV-2 multiplex test was confirmed to be 100-200 copies/mL. The clinical evaluation using contrived saliva samples indicated that the positive percentage agreement (PPA) of the QuantiVirus™ SARS-CoV-2 multiplex test is 100% at 1xLOD, 1.5xLOD and 2.5xLOD. No cross-reactivity was observed for the QuantiVirus™ SARS-CoV-2 multiplex test with common respiratory pathogens. Testing of clinical samples showed a positive percentage agreement (PPA) of 100% (95% CI: 94.6% to 100%) and a negative percentage agreement (NPA) of 98.9% (95% CI: 93.1% to 99.9%). QuantiVirus ™SARS CoV-2 multiplex test had 80% concordance rate and no significant difference ( p =0.13) in paired saliva and NPS specimens by Wilcoxon matched pairs signed rank test. Positive test rate was 1.79% for 389 saliva specimens collected from the communities for COVID-19 screening. Preliminary data showed that saliva sample pooling up to 6 samples for SARS-CoV-2 detection is feasible (sensitivity 94.8% and specificity 100%). Conclusion: The studies demonstrated that the QuantiVirus™ SARS-CoV-2 multiplex test has a LOD of 200 copies/mL in contrived saliva samples. The clinical performance of saliva-based testing is comparable to that of NPS-based testing. Pooling of saliva specimens for SARS-CoV-2 detection is feasible. Saliva based and high-throughput QuantiVirus™SARS-CoV-2 multiplex test offers a highly desirable test during the ongoing COVID-19 pandemic.
- Open Access
A Novel Xenonucleic Acid Mediated Molecular Clamping Technology for Early Colorectal Cancer Screening
Background: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape ™ for early colorectal cancer diagnostics. Methods: Nineteen mutations in four genes APC, KRAS, BRAF and CTNNB1 associated with early events in CRC pathogenesis are targeted in the ColoScape™ assay. Xenonucleic Acid (XNA) mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and a ROC cure was applied to evaluate its performance. Results: The data showed that the assay analytical sensitivity is 0.5% Variant Allele Frequency, corresponding to ~7-8 copies of mutant DNA with 5ng total DNA input per test. This assay is highly reproducible with intra-assay CV <3% and inter-assay <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were 100% (95% CI, 80.3-97.5%) and 92.2% (95% CI, 94.7-100%) respectively with AUC being about 0.96; and 96% (95% CI, 77.6-99.7%) specificity and 92% (95% CI, 86.1-95.6%) sensitivity with AUC 0.94 for CRC FFPE; and 95% specificity (95% CI, 82.5%-99.1%) and 62.5% sensitivity (95% CI, 35.8%-83.7%) with AUC 0.79 for precancerous lesions cfDNA. Conclusions: XNA mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.
Open AccessA Novel Xenonucleic Acid Mediated Molecular Clamping Technology for Early Colorectal Cancer Screening
Background: Colorectal cancer (CRC) is one of the leading causes of cancer-related death. Early detection is critical to reduce CRC morbidity and mortality. In order to meet this need, we developed a molecular clamping assay called the ColoScape ™ for early colorectal cancer diagnostics. Methods: Nineteen mutations in four genes APC, KRAS, BRAF and CTNNB1 associated with early events in CRC pathogenesis are targeted in the ColoScape™ assay. Xenonucleic Acid (XNA) mediated qPCR clamping technology was applied to minimize the wild-type background amplification in order to improve assay sensitivity of CRC mutation detection. The assay analytical performance was verified and validated, cfDNA and FFPE CRC patient samples were evaluated, and a ROC cure was applied to evaluate its performance. Results: The data showed that the assay analytical sensitivity is 0.5% Variant Allele Frequency, corresponding to ~7-8 copies of mutant DNA with 5ng total DNA input per test. This assay is highly reproducible with intra-assay CV <3% and inter-assay <5%. We have investigated 380 clinical samples including plasma cfDNA and FFPE samples from patients with precancerous and different stages of CRC. The preliminary assay clinical specificity and sensitivity for CRC cfDNA were 100% (95% CI, 80.3-97.5%) and 92.2% (95% CI, 94.7-100%) respectively with AUC being about 0.96; and 96% (95% CI, 77.6-99.7%) specificity and 92% (95% CI, 86.1-95.6%) sensitivity with AUC 0.94 for CRC FFPE; and 95% specificity (95% CI, 82.5%-99.1%) and 62.5% sensitivity (95% CI, 35.8%-83.7%) with AUC 0.79 for precancerous lesions cfDNA. Conclusions: XNA mediated molecular clamping assay is a rapid, precise, and sensitive assay for the detection of precancerous lesions cfDNA and CRC cfDNA or FFPE samples.