Jian Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jian Zheng has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Mingcheng Lyu
College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
3 shared publications - Shoudao Huang
Hunan University
3 shared publications Cunxing Peng
Hunan University of Technology
2 shared publicationsFang Liu
Hunan University of Technology
2 shared publications- Kaihui Zhao
School of Transportation and Electrical Engineering Hunan University of Technology Zhuzhou China
2 shared publications - Li Zhao
College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (5) , 1291-1302
Analytical Models of Common-Mode Voltage Under Discontinuous Pulse Width Modulation for Three-Phase Inverters
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (5) , 1291-1302
Analytical Models of Common-Mode Voltage Under Discontinuous Pulse Width Modulation for Three-Phase Inverters
- 13 April 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
An Improved Virtual Space Vector Modulation for Suppressing Common‐Mode Voltages of Three‐Phase Inverters
In three‐phase two‐level inverters, the virtual space vector modulation (VSVM) has attracted widespread attention due to its ability to reduce the amplitude of common‐mode voltage and third harmonics. However, there are still problems such as rich harmonic components of common‐mode voltage and a high rate of occurrence of amplitude and direction changes. To address these issues, an improved VSVM method is proposed. By analyzing the vector synthesis and common‐mode voltage characteristics of the classic VSVM, the basic vectors corresponding to the virtual vector and the virtual zero vector are optimally sorted, so that the common‐mode voltage waveform of each switching cycle is the same, which are all single rectangular waves. The common‐mode harmonic, dead time compensation, and switching losses of the proposed method are further analyzed. Simulations and experiments are conducted in an inverter‐permanent magnet synchronous motor system. The results show that, compared with the classic VSVM, the proposed method reduces the rate of occurrence of amplitude and direction changes by three times while maintaining the low amplitude of the common‐mode voltage. It completely eliminates the baseband harmonics and sideband harmonic components and reduces the peak value of the high‐frequency segment of the common‐mode voltage by an average of 6 dB. Meanwhile, the performance of line voltages, line currents, torque, and speed remains excellent. This method can more effectively suppress common‐mode current without increasing the system volume and cost, which is beneficial for the design of common‐mode filters and provides a reference for the research of other common‐mode suppression PWM methods.
- 13 April 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
An Improved Virtual Space Vector Modulation for Suppressing Common‐Mode Voltages of Three‐Phase Inverters
In three‐phase two‐level inverters, the virtual space vector modulation (VSVM) has attracted widespread attention due to its ability to reduce the amplitude of common‐mode voltage and third harmonics. However, there are still problems such as rich harmonic components of common‐mode voltage and a high rate of occurrence of amplitude and direction changes. To address these issues, an improved VSVM method is proposed. By analyzing the vector synthesis and common‐mode voltage characteristics of the classic VSVM, the basic vectors corresponding to the virtual vector and the virtual zero vector are optimally sorted, so that the common‐mode voltage waveform of each switching cycle is the same, which are all single rectangular waves. The common‐mode harmonic, dead time compensation, and switching losses of the proposed method are further analyzed. Simulations and experiments are conducted in an inverter‐permanent magnet synchronous motor system. The results show that, compared with the classic VSVM, the proposed method reduces the rate of occurrence of amplitude and direction changes by three times while maintaining the low amplitude of the common‐mode voltage. It completely eliminates the baseband harmonics and sideband harmonic components and reduces the peak value of the high‐frequency segment of the common‐mode voltage by an average of 6 dB. Meanwhile, the performance of line voltages, line currents, torque, and speed remains excellent. This method can more effectively suppress common‐mode current without increasing the system volume and cost, which is beneficial for the design of common‐mode filters and provides a reference for the research of other common‐mode suppression PWM methods.
- Open Access
A Low Common-Mode SVPWM for Two-Level Three-Phase Voltage Source Inverters
In order to reduce the common-mode voltage (CMV) generated by the use of space vector pulse width modulation (SVPWM) in two-level three-phase voltage source inverters, a low common-mode SVPWM method is proposed. In this method, the voltage plane is divided into 12 sectors, and on each sector, two non-zero vectors of the same class and one single zero vector are adopted for synthesis. The action time of the zero vector is placed at both ends of each switching cycle, the currents are sampled at the beginning of each switching cycle, and the action time and sequence of vectors on each sector is provided. Simulation and experimental results show that, in the vector control system of a permanent magnet synchronous motor fed by the inverter, compared with the conventional SVPWM, the proposed method reduces the CMV peak-to-valley value by 33.333%, the CMV jump frequency by three times, and the performance of the line voltage and line current. The electromagnetic torque and rotor speed remain good, which has good application value in high-performance drives.
Open AccessA Low Common-Mode SVPWM for Two-Level Three-Phase Voltage Source Inverters
In order to reduce the common-mode voltage (CMV) generated by the use of space vector pulse width modulation (SVPWM) in two-level three-phase voltage source inverters, a low common-mode SVPWM method is proposed. In this method, the voltage plane is divided into 12 sectors, and on each sector, two non-zero vectors of the same class and one single zero vector are adopted for synthesis. The action time of the zero vector is placed at both ends of each switching cycle, the currents are sampled at the beginning of each switching cycle, and the action time and sequence of vectors on each sector is provided. Simulation and experimental results show that, in the vector control system of a permanent magnet synchronous motor fed by the inverter, compared with the conventional SVPWM, the proposed method reduces the CMV peak-to-valley value by 33.333%, the CMV jump frequency by three times, and the performance of the line voltage and line current. The electromagnetic torque and rotor speed remain good, which has good application value in high-performance drives.
- Open Access
A Harmonic Suppression SVPWM Strategy for the Asymmetric Six-Phase Motor Fed by Two-Level Six-Phase VSI Operating in the Overmodulation Region
For the asymmetric six-phase motor fed by a two-level six-phase voltage source inverter (VSI), when the modulation index is less than 0.5774, the motor operates in the linear region, and the harmonics in the Z1 − Z2 subspace can be suppressed to zero. When the modulation index is beyond 0.5774 and less than 0.6221, the motor operates in overmodulation regions, and the harmonics in the Z1 − Z2 subspace cannot be suppressed to zero. To minimize the harmonics in the Z1 − Z2 subspace for these regions, a harmonic suppression strategy, namely, harmonic suppression overmodulation strategy (HSOS), is proposed in this paper. The lower-order harmonics of the Z1 − Z2 subspace, namely, the 5th, 7th, 17th and 19th, are considered. Compared with the traditional four-vector overmodulation strategy (TFOS), the content of the 5th harmonic is reduced by about 20%, and the total harmonic distortion (THDZ1Z2) of these four kinds of harmonics is reduced by about 21% in the proposed HSOS. Finally, the simulation and experiment are carried out to verify the effectiveness of the proposed strategy.
Open AccessA Harmonic Suppression SVPWM Strategy for the Asymmetric Six-Phase Motor Fed by Two-Level Six-Phase VSI Operating in the Overmodulation Region
For the asymmetric six-phase motor fed by a two-level six-phase voltage source inverter (VSI), when the modulation index is less than 0.5774, the motor operates in the linear region, and the harmonics in the Z1 − Z2 subspace can be suppressed to zero. When the modulation index is beyond 0.5774 and less than 0.6221, the motor operates in overmodulation regions, and the harmonics in the Z1 − Z2 subspace cannot be suppressed to zero. To minimize the harmonics in the Z1 − Z2 subspace for these regions, a harmonic suppression strategy, namely, harmonic suppression overmodulation strategy (HSOS), is proposed in this paper. The lower-order harmonics of the Z1 − Z2 subspace, namely, the 5th, 7th, 17th and 19th, are considered. Compared with the traditional four-vector overmodulation strategy (TFOS), the content of the 5th harmonic is reduced by about 20%, and the total harmonic distortion (THDZ1Z2) of these four kinds of harmonics is reduced by about 21% in the proposed HSOS. Finally, the simulation and experiment are carried out to verify the effectiveness of the proposed strategy.
- Open Access
A Common-Mode Voltage Suppression Strategy Based on Double Zero-Sequence Injection PWM for Two-Level Six-Phase VSIs
A common-mode voltage (CMV) suppression strategy, namely double zero-sequence injection common-mode voltage (DZICMV), is proposed in this paper for an asymmetrical six-phase induction motor fed by two-level dual three-phase voltage source inverters (VSIs). In this strategy, the sinusoidal waveforms injected by double zero-sequence signals are employed as modulation signals, and two opposite triangular waveforms are used as carriers. The fundamental period is divided into 24 sectors. In each sector, the carrier used by the medium amplitude phase is distinct from the carriers used by the other two phases in each set of three-phase windings. Using this method, the zero vectors (000) and (111) in each set of three-phase windings can be eliminated, and the peak values of sub-CMV and total CMV can be reduced from ±Udc/2 to ±Udc/6. The experiment results show that the root mean square (RMS) value of common-mode leakage current in DZICMV can be reduced by 51.83% compared with the double zero-sequence injection PWM (DZIPWM) strategy. It is also found in the other four existing benchmark CMV suppression strategies that the peak values of sub-CMV therein are nearly all ±Udc/2, and only in the low linear modulation region could one of these strategies suppress sub-CMV peak values to ±Udc/6. However, the proposed DZICMV can suppress the sub-CMV peak values to ±Udc/6 in the whole linear modulation range. Moreover, the maximum linear modulation index of the DZICMV is 1.15, which is larger than that of the four benchmark strategies, whose maximum modulation index is 1.
Open AccessA Common-Mode Voltage Suppression Strategy Based on Double Zero-Sequence Injection PWM for Two-Level Six-Phase VSIs
A common-mode voltage (CMV) suppression strategy, namely double zero-sequence injection common-mode voltage (DZICMV), is proposed in this paper for an asymmetrical six-phase induction motor fed by two-level dual three-phase voltage source inverters (VSIs). In this strategy, the sinusoidal waveforms injected by double zero-sequence signals are employed as modulation signals, and two opposite triangular waveforms are used as carriers. The fundamental period is divided into 24 sectors. In each sector, the carrier used by the medium amplitude phase is distinct from the carriers used by the other two phases in each set of three-phase windings. Using this method, the zero vectors (000) and (111) in each set of three-phase windings can be eliminated, and the peak values of sub-CMV and total CMV can be reduced from ±Udc/2 to ±Udc/6. The experiment results show that the root mean square (RMS) value of common-mode leakage current in DZICMV can be reduced by 51.83% compared with the double zero-sequence injection PWM (DZIPWM) strategy. It is also found in the other four existing benchmark CMV suppression strategies that the peak values of sub-CMV therein are nearly all ±Udc/2, and only in the low linear modulation region could one of these strategies suppress sub-CMV peak values to ±Udc/6. However, the proposed DZICMV can suppress the sub-CMV peak values to ±Udc/6 in the whole linear modulation range. Moreover, the maximum linear modulation index of the DZICMV is 1.15, which is larger than that of the four benchmark strategies, whose maximum modulation index is 1.
- Open Access
Characteristic Analysis and Predictive Torque Control of the Modular Three-Phase PMSM for Low-Voltage High Power Application
In this study, a novel modular three-phase permanent magnet synchronous motor (PMSM) is proposed for low-voltage high power applications. The proposed modular three-phase PMSM has an independent segregated three-phase winding configuration, facilitating the implementation of the control algorithm. Firstly, on the basis of the electromagnetic properties, the mathematical model of the modular three-phase PMSM is established, considering the asymmetrical mutual inductances investigated by finite element analysis (FEA). Then, the predictive torque control (PTC) method combining the inductance characteristics of modular three-phase PMSM is developed, and excellent performance is obtained by adjusting the stator flux and torque. Finally, simulation and experiment are performed, and the results show that the proposed novel modular three-phase PMSM with the PTC method exhibits excellent control performance, and small stator current total harmonic distortion (THD).
Open AccessCharacteristic Analysis and Predictive Torque Control of the Modular Three-Phase PMSM for Low-Voltage High Power Application
In this study, a novel modular three-phase permanent magnet synchronous motor (PMSM) is proposed for low-voltage high power applications. The proposed modular three-phase PMSM has an independent segregated three-phase winding configuration, facilitating the implementation of the control algorithm. Firstly, on the basis of the electromagnetic properties, the mathematical model of the modular three-phase PMSM is established, considering the asymmetrical mutual inductances investigated by finite element analysis (FEA). Then, the predictive torque control (PTC) method combining the inductance characteristics of modular three-phase PMSM is developed, and excellent performance is obtained by adjusting the stator flux and torque. Finally, simulation and experiment are performed, and the results show that the proposed novel modular three-phase PMSM with the PTC method exhibits excellent control performance, and small stator current total harmonic distortion (THD).
- Open Access
Common-Mode Reduction SVPWM for Three-Phase Motor Fed by Two-Level Voltage Source Inverter
Aiming at the problem of large magnitude and high frequency of common-mode voltage (CMV) when space vector pulse width modulation (SVPWM) is used in a three-phase motor fed by a two-level voltage source inverter, a common-mode reduction SVPWM (CMRSVPWM) is studied. In this method, six new sectors are obtained by rotating six sectors of conventional SVPWM by 30°. In odd-numbered sectors, only three non-zero vectors with odd subscripts are used for synthesis, while in even-numbered sectors, only three non-zero vectors with even subscripts are used for synthesis. The actuation durations of three non-zero vectors in each switching period in each sector are given. Simulation and experimental results show that, compared with the conventional SVPWM, the CMV magnitude of CMRSVPWM is reduced by 66.67% and the CMV frequency of CMRSVPWM is reduced from the original switching frequency to the triple fundamental frequency. At the same time, the current, torque and speed of the motor are still good.
Open AccessCommon-Mode Reduction SVPWM for Three-Phase Motor Fed by Two-Level Voltage Source Inverter
Aiming at the problem of large magnitude and high frequency of common-mode voltage (CMV) when space vector pulse width modulation (SVPWM) is used in a three-phase motor fed by a two-level voltage source inverter, a common-mode reduction SVPWM (CMRSVPWM) is studied. In this method, six new sectors are obtained by rotating six sectors of conventional SVPWM by 30°. In odd-numbered sectors, only three non-zero vectors with odd subscripts are used for synthesis, while in even-numbered sectors, only three non-zero vectors with even subscripts are used for synthesis. The actuation durations of three non-zero vectors in each switching period in each sector are given. Simulation and experimental results show that, compared with the conventional SVPWM, the CMV magnitude of CMRSVPWM is reduced by 66.67% and the CMV frequency of CMRSVPWM is reduced from the original switching frequency to the triple fundamental frequency. At the same time, the current, torque and speed of the motor are still good.
- Open Access
Predictive Power Control of Novel N*3-phase PM Energy Storage Motor for Urban Rail Transit
High power density energy storage permanent magnet (PM) motor is an important energy storage module in flywheel energy storage system for urban rail transit. To expand the application of the PM motor in the field of urban rail transit, a predictive power control (PPC) strategy for the N*3-phase PM energy storage motor is proposed in this paper. Firstly, the output characteristics of the N*3-phase PM energy storage motor are analyzed by using the finite element method, and the mathematical model of the N*3-phase PM energy storage motor is established. Then, the topological structure and operation principle of N*3-phase PM energy storage motor system is illustrated. Furthermore, the N*3-phase PM energy storage motor system driven by six parallel voltage source inverters (VSIs) is proposed to generate the required power. Finally, a novel predictive direct power control method is developed for the N*3-phase PM energy storage motor. The feasibility and effectively of the proposed PPC method are verified by experiment and simulation. Comprehensive simulation and experimental results both show that the proposed PPC method can obtain the lower torque/stator flux ripple, smaller values of THD of stator winding currents, and zero error tracking of stator winding flux.
Open AccessPredictive Power Control of Novel N*3-phase PM Energy Storage Motor for Urban Rail Transit
High power density energy storage permanent magnet (PM) motor is an important energy storage module in flywheel energy storage system for urban rail transit. To expand the application of the PM motor in the field of urban rail transit, a predictive power control (PPC) strategy for the N*3-phase PM energy storage motor is proposed in this paper. Firstly, the output characteristics of the N*3-phase PM energy storage motor are analyzed by using the finite element method, and the mathematical model of the N*3-phase PM energy storage motor is established. Then, the topological structure and operation principle of N*3-phase PM energy storage motor system is illustrated. Furthermore, the N*3-phase PM energy storage motor system driven by six parallel voltage source inverters (VSIs) is proposed to generate the required power. Finally, a novel predictive direct power control method is developed for the N*3-phase PM energy storage motor. The feasibility and effectively of the proposed PPC method are verified by experiment and simulation. Comprehensive simulation and experimental results both show that the proposed PPC method can obtain the lower torque/stator flux ripple, smaller values of THD of stator winding currents, and zero error tracking of stator winding flux.
- Open Access
Optimal Modeled Six-Phase Space Vector Pulse Width Modulation Method for Stator Voltage Harmonic Suppression
Dual Y shift 30° six-phase motors are expected to be extensively applied in high-power yet energy-effective fields, and a harmonic-suppressing control strategy plays a vital role in extending their prominent features of low losses and ultra-quiet operation. Aiming at the suppression of harmonic voltages, this paper proposes a six-phase space vector pulse width modulation method based on an optimization model, namely OM-SVPWM. First, four adjacent large vectors are employed in each of 12 sectors on a fundamental sub-plane. Second, the optimization model is constructed to intelligently determine activation durations of the four vectors, where its objective function aims to minimize the synthesis result on a harmonic sub-plane, and its constraint condition is that the synthesis result on the fundamental sub-plane satisfies a reference vector. Finally, to meet the real-time requirement, optimum solutions are obtained by using general central path following algorithm (GCPFA). Simulation and experiment results prove that, the OM-SVPWM performs around 37% better than a state-of-the-art competitive SVPWM in terms of harmonics suppression, which promise the proposed OM-SVPWM conforms to the energy-effective direction in actual engineering applications.
Open AccessOptimal Modeled Six-Phase Space Vector Pulse Width Modulation Method for Stator Voltage Harmonic Suppression
Dual Y shift 30° six-phase motors are expected to be extensively applied in high-power yet energy-effective fields, and a harmonic-suppressing control strategy plays a vital role in extending their prominent features of low losses and ultra-quiet operation. Aiming at the suppression of harmonic voltages, this paper proposes a six-phase space vector pulse width modulation method based on an optimization model, namely OM-SVPWM. First, four adjacent large vectors are employed in each of 12 sectors on a fundamental sub-plane. Second, the optimization model is constructed to intelligently determine activation durations of the four vectors, where its objective function aims to minimize the synthesis result on a harmonic sub-plane, and its constraint condition is that the synthesis result on the fundamental sub-plane satisfies a reference vector. Finally, to meet the real-time requirement, optimum solutions are obtained by using general central path following algorithm (GCPFA). Simulation and experiment results prove that, the OM-SVPWM performs around 37% better than a state-of-the-art competitive SVPWM in terms of harmonics suppression, which promise the proposed OM-SVPWM conforms to the energy-effective direction in actual engineering applications.
- Open Access
Six-Phase Space Vector PWM under Stator One-Phase Open-Circuit Fault Condition
The torque pulsation and speed pulsation of a six-phase induction machine with double Y-connected windings displaced by 30° increase after one phase of the stator winding is open-circuited. To reduce the pulsations, a method of six-phase space vector pulse width modulation (PWM) with fault-tolerance is proposed. The star point of the open-circuit winding group is connected to the centre point of the converter DC voltage. The 32 column matrices, which represent 32 stator winding voltages, are mapped to the d-q and z1-z2 planes using a new five-dimensional orthogonal matrix; then, 32 basic vectors are obtained. By using an optimal model, six auxiliary vectors and an equivalent null vector are constructed, the magnitudes of which are all zero in the z1-z2 plane. By using the auxiliary vectors and equivalent null vector, the reference vector is synthesized, the zero magnitude of which in the z1-z2 plane can suppress the harmonic voltages, and the circular trajectory of which in the d-q plane can make the torque smooth. The simulation and experimental results show that the torque pulsation range and speed pulsation range of the proposed method with fault-tolerance are 30% and 25% of those of the classical method without fault-tolerance, respectively. Thus, the phase-deficient operation performance of the system is improved.
Open AccessSix-Phase Space Vector PWM under Stator One-Phase Open-Circuit Fault Condition
The torque pulsation and speed pulsation of a six-phase induction machine with double Y-connected windings displaced by 30° increase after one phase of the stator winding is open-circuited. To reduce the pulsations, a method of six-phase space vector pulse width modulation (PWM) with fault-tolerance is proposed. The star point of the open-circuit winding group is connected to the centre point of the converter DC voltage. The 32 column matrices, which represent 32 stator winding voltages, are mapped to the d-q and z1-z2 planes using a new five-dimensional orthogonal matrix; then, 32 basic vectors are obtained. By using an optimal model, six auxiliary vectors and an equivalent null vector are constructed, the magnitudes of which are all zero in the z1-z2 plane. By using the auxiliary vectors and equivalent null vector, the reference vector is synthesized, the zero magnitude of which in the z1-z2 plane can suppress the harmonic voltages, and the circular trajectory of which in the d-q plane can make the torque smooth. The simulation and experimental results show that the torque pulsation range and speed pulsation range of the proposed method with fault-tolerance are 30% and 25% of those of the classical method without fault-tolerance, respectively. Thus, the phase-deficient operation performance of the system is improved.