P. Alberto Giuliano Albo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
P. Alberto Giuliano Albo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Simona Lago
Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce 91, 10135 Torino, Italy
6 shared publications - Adriano Troia
Ultrasounds & Chemistry Lab, Advanced Metrology for Quality of Life, Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.), Turin, Italy.
1 shared publication - Chiara Musacchio
Istituto Nazionale di Ricerca Metrologica (INRIM), 10135 Turin, Italy
1 shared publication G. Benedetto
Istituto Nazionale di Ricerca Metrologica
1 shared publication- Giuseppe Cavuoto
Italian National Research Council (CNR)
1 shared publication - Giuseppe Cavuoto1 shared publication
Latest Publications
- Open Access
- 31 January 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 105, 1178-1185
Towards the validation of ultrasonic flowmeters operating in hydrogen-enriched natural gas mixtures through speed of sound measurements obtained by a clamp-on meter
- 31 January 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 105, 1178-1185
Open AccessTowards the validation of ultrasonic flowmeters operating in hydrogen-enriched natural gas mixtures through speed of sound measurements obtained by a clamp-on meter
- Open Access
- 1 August 2021
- Published by Elsevier in Measurement
- Vol. 180, 109526
Towards a new transfer standard for speed of sound measurements in liquids at cryogenic temperatures
- 1 August 2021
- Published by Elsevier in Measurement
- Vol. 180, 109526
Open AccessTowards a new transfer standard for speed of sound measurements in liquids at cryogenic temperatures
- 19 October 2018
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 149 (15) , 154503
Experimental densities of subcooled deuterium oxide at pressures up to 160 MPa
In this work, the experimental results of deuterium oxide density at high pressure and in a wide range of temperatures, by means of the pseudo-isochoric method, are presented. A specific stainless steel cell was devised to be used as a pycnometer and filled with variable mass of heavy water. The latter was measured by weighing with an analytical balance and using the substitution method. The volume of the pycnometric cell was measured by the gravimetric method and corrected for the effect of temperature and pressure. Each measurement cycle was performed at constant mass, measuring pressure as a function of temperature at equilibrium. From the mass and volume values, density was calculated according to its definition. Heavy water density was measured for temperatures down to 253 K and for pressures up to 163 MPa, thus both in stable and supercooled metastable states. All terms contributing to the uncertainty in determining the volume and the mass were considered, obtaining an expanded relative uncertainty of deuterium oxide density of 0.04%.
- 19 October 2018
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 149 (15) , 154503
Experimental densities of subcooled deuterium oxide at pressures up to 160 MPa
In this work, the experimental results of deuterium oxide density at high pressure and in a wide range of temperatures, by means of the pseudo-isochoric method, are presented. A specific stainless steel cell was devised to be used as a pycnometer and filled with variable mass of heavy water. The latter was measured by weighing with an analytical balance and using the substitution method. The volume of the pycnometric cell was measured by the gravimetric method and corrected for the effect of temperature and pressure. Each measurement cycle was performed at constant mass, measuring pressure as a function of temperature at equilibrium. From the mass and volume values, density was calculated according to its definition. Heavy water density was measured for temperatures down to 253 K and for pressures up to 163 MPa, thus both in stable and supercooled metastable states. All terms contributing to the uncertainty in determining the volume and the mass were considered, obtaining an expanded relative uncertainty of deuterium oxide density of 0.04%.
- 1 January 2017
- Published by Elsevier in Biomass and Bioenergy
- Vol. 96, 87-95
Density, viscosity and specific heat capacity of diesel blends with rapeseed and soybean oil methyl ester
- 1 January 2017
- Published by Elsevier in Biomass and Bioenergy
- Vol. 96, 87-95
Density, viscosity and specific heat capacity of diesel blends with rapeseed and soybean oil methyl ester
- 16 February 2016
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 144 (7) , 074501
Density measurements of subcooled water in the temperature range of (243 and 283) K and for pressures up to 400 MPa
In this work, accurate density measurements of subcooled water (freshly double-distilled water) were performed along eight constant-mass curves in the temperature range of (243 to 283) K and in the pressure range of (140 to 400) MPa, by a pseudo-isochoric method. The experimental apparatus mainly consisted of a high pressure vessel, especially designed for this experiment, of known volume as a function of temperature and pressure, used to perform measurements in the T-p range under study. The density of subcooled water was obtained by measuring the equilibrium pressure at different temperatures, keeping the mass constant. All terms contributing to the uncertainty of subcooled water density measurements were considered; the estimated relative uncertainty, in the investigated temperature and pressure range, is about 0.07%. The experimental results were compared with the literature densities. In particular, the trend of density versus temperature for a constant mass of sample observed experimentally differs from the trend calculated by the equation provided by the International Association for Properties of Water and Steam (IAPWS-95) outside the range of validity, i.e., in the metastable region.
- 16 February 2016
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 144 (7) , 074501
Density measurements of subcooled water in the temperature range of (243 and 283) K and for pressures up to 400 MPa
In this work, accurate density measurements of subcooled water (freshly double-distilled water) were performed along eight constant-mass curves in the temperature range of (243 to 283) K and in the pressure range of (140 to 400) MPa, by a pseudo-isochoric method. The experimental apparatus mainly consisted of a high pressure vessel, especially designed for this experiment, of known volume as a function of temperature and pressure, used to perform measurements in the T-p range under study. The density of subcooled water was obtained by measuring the equilibrium pressure at different temperatures, keeping the mass constant. All terms contributing to the uncertainty of subcooled water density measurements were considered; the estimated relative uncertainty, in the investigated temperature and pressure range, is about 0.07%. The experimental results were compared with the literature densities. In particular, the trend of density versus temperature for a constant mass of sample observed experimentally differs from the trend calculated by the equation provided by the International Association for Properties of Water and Steam (IAPWS-95) outside the range of validity, i.e., in the metastable region.
- 1 February 2015
- Published by Elsevier in Ultrasonics
- Vol. 56, 210-219
Acoustical characterization of polysaccharide polymers tissue-mimicking materials
- 1 February 2015
- Published by Elsevier in Ultrasonics
- Vol. 56, 210-219
Acoustical characterization of polysaccharide polymers tissue-mimicking materials
- 27 July 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (7) , 1248-1258
Modeling Steady Acoustic Fields Bounded in Cavities with Geometrical Imperfections
- 27 July 2010
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 31 (7) , 1248-1258
Modeling Steady Acoustic Fields Bounded in Cavities with Geometrical Imperfections
- 1 April 2010
- Published by Elsevier in The Journal of Chemical Thermodynamics
- Vol. 42 (4) , 462-465
A recursive equation method for the determination of density and heat capacity: Comparison between isentropic and isothermal integration paths
- 1 April 2010
- Published by Elsevier in The Journal of Chemical Thermodynamics
- Vol. 42 (4) , 462-465
A recursive equation method for the determination of density and heat capacity: Comparison between isentropic and isothermal integration paths