YTYunbo Tian

Yunbo Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yunbo Tian has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Zhenxing Wang

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, People’s Republic of China

    3 shared publications
  • Jianhua Wang

    Xi'an Jiaotong University 1 State Key Laboratory of Electrical Insulation and Power Equipment Xi'an 710049, China

    2 shared publications
  • Yingsan Geng

    Xi'an Jiaotong University 1 State Key Laboratory of Electrical Insulation and Power Equipment Xi'an 710049, China

    2 shared publications
  • Zhiyuan Liu

    Xi'an Jiaotong University 1 State Key Laboratory of Electrical Insulation and Power Equipment Xi'an 710049, China

    2 shared publications
  • Flyura Djurabekova

    University of Helsinki

    1 shared publication
  • Haoran Wang

    Xi'an Jiaotong University State Key Laboratory of Electrical Insulation and Power Equipment Xi'an 710049, China

    1 shared publication

Latest Publications

  • Modelling of crater formation on anode surface by high-current vacuum arcs

    by Yunbo Tian, Zhenxing Wang, Yanjun Jiang, Hui Ma, Zhiyuan Liu, Yingsan Geng, Jianhua Wang, Kai Nordlund, Flyura Djurabekova

    Anode melting and crater formation significantly affect interruption of high-current vacuum arcs. The primary objective of this paper is to theoretically investigate the mechanism of anode surface crater formation, caused by the combined effect of surface heating during the vacuum arc and pressure exerted on the molten surface by ions and electrons from the arc plasma. A model of fluid flow and heat transfer in the arc anode is developed and combined with a magnetohydrodynamics model of the vacuum arc plasma. Crater formation is observed in simulation for a peak arcing current higher than 15 kA on 40 mm diam. Cu electrodes spaced 10 mm apart. The flow of liquid metal starts after 4 or 5 ms of arcing, and the maximum velocities are 0.95 m/s and 1.39 m/s for 20 kA and 25 kA arcs, respectively. This flow redistributes thermal energy, and the maximum temperature of the anode surface does not remain in the center. Moreover, the condition for the liquid droplet formation on the anode surfaces is developed. The solidification process after current zero is also analyzed. The solidification time has been found to be more than 3 ms after 25 kA arcing. The long solidification time and sharp features on crater rims induce Taylor cone formation.


  • Fully kinetic model of breakdown during sheath expansion after interruption of vacuum arcs

    by Zhenxing Wang, Haoran Wang, Zhipeng Zhou, Yunbo Tian, Yingsan Geng, Jianhua Wang, Zhiyuan Liu

    Research on sheath expansion is critical to the understanding of the dielectric recovery process in a vacuum interrupter after interruption of vacuum arcs. In this paper, we investigated how residual plasma affects breakdown in the sheath expansion period after the current zero. To simulate sheath expansion and breakdown, we developed a fully kinetic particle-in-cell Monte Carlo collision model with one spatial dimension and three velocity dimensions. The model accounted for various collisions, including ionization, excitation, elastic collisions, charge exchange, and momentum exchange, and we added an external circuit to the model to make the calculations self-consistent. The existence of metal vapor slowed the sheath expansion in the gap and caused high electric field formation in front of the cathode surface. The initial residual plasma, which was at sufficiently low density, seemed to have a limited impact on breakdown, and the metal vapor dominated the breakdown in this case. Additionally, the breakdown probability was sensitive to the initial plasma density if the value exceeded a specific threshold, and plasma at sufficiently high density could mean that breakdown would occur more easily. We found that if the simulation does not take the residual plasma into account, it could overestimate the critical value of the metal vapor density, which is always used to describe the boundary of breakdown after interruption of vacuum arcs. We discussed the breakdown mechanism in sheath expansion, and the breakdown is determined by a combination of metal vapor, residual plasma, and the electric field in front of the cathode surface.


  • Simulation of breakdown in Cu-Cr metal vapor after vacuum arc extinctions

    by Zhenxing Wang, Yunbo Tian, Yingsan Geng, Zhiyuan Liu

    Metal vapor has a significant influence on dielectric recovery behaviors after interrupting a high vacuum arc. The objective of this paper is to study breakdowns in copper, chromium and copper-chromium vapors employing the PIC-MCC method. A 2d model with a given DC voltage is applied to study the breakdown processes in the metal vapor after vacuum arc extinctions taking into account thermal-field emission, secondary electron emission, plasma and neutral transport. The results confirm that the breakdown voltage decreased with the increase of the surface temperature. At the same surface temperature, the breakdown voltages for different metal vapors follow the trend of copper> chromium > copper-chromium.