YWYongmei Wang

Yongmei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yongmei Wang has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-sensitivity tilt sensor based on a cascaded core-offset and spherical single-mode fiber interferometer

    by Xiangyu Liao, Songwei Li, Lianghua Chen, Qiunan Zhang, Yongmei Wang, Yun Chen, Liangyu Huang, Jian Tang, Junhui Hu

    A high-sensitivity fiber-optic tilt sensor based on Mach–Zehnder interference is proposed. The design uses a controlled core-offset to excite higher-order cladding modes in a few-mode fiber (FMF) and incorporates a spherical structure to enhance intermodal coupling efficiency. This configuration yields high fringe contrast and provides a sensitive, monotonic response to tilt angle variation. The influences of FMF length on the free spectral range, core-offset higher-order modes excitation, and spherical structure diameter on interference fringe contrast were systematically investigated. Experimental results demonstrated that, over a tilt range from 15.26° to 32.47°, the sensor achieves a sensitivity as high as −5.07 nm/°, while the temperature sensitivity is only 0.03 nm°C −1 between 24 °C and 36 °C. The corresponding temperature cross-sensitivity is as low as 0.006°/°C. The combination of high tilt responsivity and suppressed thermal crosstalk makes the sensor well suited for stable operation in complex environments and suggests strong potential for deformation monitoring of engineering structures.

  • Single-mode low-loss small-mode-field hollow-core anti-resonant fiber with arc-shaped tubes

    by Pufan Zhong, Min Zhou, Min Lu, Yan He, Shuyu Xi, Yongmei Wang, Hanglin Lu, Junhui Hu, Jian Tang, Zhe Zhang

    Although hollow-core anti-resonant fibers (HC-ARFs) have achieved remarkable progress in realizing low transmission loss and broad operating bandwidths, their performance optimization generally relies on enlarging the core size and mode field area. However, this approach weakens light–gas interactions and reduces the optical power density. To overcome this limitation, we propose a small-mode-field HC-ARF incorporating arc-shaped tubes, which simultaneously achieves low loss, broad bandwidth, and excellent single-mode performance with a core diameter of only 20 μm. Finite-element-method simulations show that the higher-order mode extinction ratio (HOMER) remains above 2151 across a wide transmission bandwidth from 1150 to 2050 nm, reaching a maximum value of 15535 at 1550 nm. Additionally, a minimum confinement loss (CL) of 0.001 dB km −1 is achieved at 1550 nm. The bending loss (BL) is kept below 0.046 dB km −1 for a bending radius ( R b ) of 15 cm. These results indicate that the proposed HC-ARF offers a promising platform for applications in gas Raman scattering, nonlinear optics, and high-sensitivity gas sensing.


  • Open Access

    Ultralow Loss Hollow-Core Anti-Resonant Fiber With Elliptical Nested Elements

    by Pufan Zhong, Jian Tang, Zhe Zhang, Min Zhou, Min Lu, Yan He, Shuyu Xi, Yongmei Wang, Hanglin Lu, Junhui Hu

    Continued loss reduction in hollow-core anti-resonant fibers remains an essential challenge. This work presents an ultra-low loss hollow-core anti-resonant fiber design featuring a triple-nested cladding architecture with elliptical nested elements and six auxiliary compensation tubes located between the external circular tubes. Through fiber structure optimization using the finite element method, a broad transmission bandwidth from 1380–1700 nm and a confinement loss of less than 4.63 × 10−5 dB/km is achieved. At the 1550 nm operating wavelength, the structure exhibits a minimum confinement loss of 3.29 × 10−6 dB/km, which is two orders of magnitude lower than that of double-layer circular nested structures, and surface scattering loss of approximately 1.1 × 10−2 dB/km. At a 6 cm bending radius, the bending loss is below 5.8 × 10−3 dB/km. The low-loss performance of this fiber structure has potential applications including long-haul optical fiber communications, fiber gas lasers, and distributed sensing systems.


  • A peanut-shaped structure fiber optic sensor for curvature sensing via intermodal interference

    by Yangtao Liu, Xiangyu Liao, Zhenbo Yan, Qiunan Zhang, Zhangwei Tong, Yongmei Wang, Chuanyang Huang, Jian Tang, Junhui Hu

    This paper presents and experimentally demonstrates a curvature sensor utilizing intermodal interference. The sensor is constructed by splicing a no-core fiber (NCF) between 2 single-mode fibers (SMFs) and incorporating several peanut-shaped (P-S) structures. While adding multiple P-S structures enhances the excitation of high-order cladding modes, thereby influencing both curvature sensitivity and measurement range. The research results reveal that a 1 P-S structure yields a maximum curvature sensitivity of −31.95 nm/m −1 . In comparison, the sensitivity decreases by 3.43 nm/m −1 with 2 P-S structures and by 17.5 nm/m −1 when the number increases to 3, with a corresponding reduction in sensing range of 0.467 m −1 . Temperature tests reveal a sensitivity of 0.058 nm/°C and a temperature-induced curvature crosstalk of 0.0018 m −1 /°C for the single-structure sensor. By adjusting the number of the peanut-shaped structures in the sensor, the sensitivity and detection range can be tailored for specific applications, such as extreme environment detection and deep-sea exploration.


  • U-Shaped PCF-SPR Temperature Sensor with High Sensitivity

    by Qiunan Zhang, Zhangwei Tong, Xiangyu Liao, Yongmei Wang, Yangtao Liu, Weijia Shao, Junhui Hu


  • Fiber Vector Torsion Sensor With Low Crosstalk for Temperature and Strain Based on Mach–Zehnder Interference

    by Laipeng Shao, Chuanyang Huang, Zhenbo Yan, Yongmei Wang, Hongdong Chen, Caner Cheng, Songwei Li, Qiunan Zhang, Xiangyu Liao, Jian Tang, et al.

    A Mach-Zehnder interferometer (MZI) based on a polarization-maintaining fiber-few-mode fiber (PMF-FMF) structure is proposed to achieve high-sensitivity vector torsion sensing. The effects of fiber lengths, core offset directions, and offset magnitudes of both PMF and FMF on the interference spectra are investigated. Leveraging the properties of PMF, when the sensor is twisted, changes in the polarization state of the transmitted light alter the intensity of interference dips, causing the wavelengths of the envelope valleys to shift in opposite directions, which enables the discrimination of torsion direction. Additionally, the influence of PMF and FMF lengths on the interference spectra is studied, and experimental measurements of torsion, temperature, and strain sensing are conducted. Experimental results show that the maximum torsion sensitivity for clockwise (CW) rotation is 0.91 nm/(rad/m), and that for counterclockwise (CCW) rotation is -0.61 nm/(rad/m). Additionally, the sensor features simple fabrication, low sensitivity to strain and temperature interference, and a measurement error of less than 4%. These characteristics make it highly suitable for structural health monitoring applications in civil engineering and aerospace industries.


  • Highly sensitive PCF sensor based on SPR effect for dual-parameter detection of cancer cells and temperature

    by Qiunan Zhang, Xiangyu Liao, Yongmei Wang, Caner Cheng, Chuanyang Huang, Yangtao Liu, Weijia Shao, Qingjia Zhou, Jian Tang, Junhui Hu, et al.

    The sensor proposed in the present study is a novel bilateral polished D-type photonic crystal fiber (PCF)-based dual-parameter device that operates on the principle of surface plasmon resonance (SPR). It was designed for the simultaneous detection of six types of cancer—skin cancer, cervical cancer, blood cancer, adrenal gland cancer, and two subtypes of breast cancer (type 1 and type 2)—alongside temperature measurement. Numerical simulations employing the full-vector finite element method indicate that, within the refractive index (RI) range of 1.360 – 1.401, the sensor achieved a maximum wavelength sensitivity of 32,000 nm RIU−1 for breast cancer type 2 detection, with a high figure of merit (FOM) of 914 RIU−1 and a detection resolution of 3.125 × 10−6 RIU. Further, the sensor exhibited an ultrahigh temperature sensitivity of −28.7 nm °C−1 within the 0 °C–50 °C range, accompanied by a FOM of −0.164 °C−1 and a resolution of 3.484 × 10−3 °C. Compared to similar designs, the proposed sensor enfs independent and highly sensitive detection of both refractive index and temperature, while featuring a simplified structure and low fabrication complexity. These characteristics underscore its strong potential for application in biomedical diagnostics, particularly for cancer detection and monitoring.


  • Planar, broadband, and tunable hot-electron photodetection with chromium-involved Tamm plasmons

    by Yaoyao Li, Weihao Cui, Yongmei Wang, Qingjia Zhou, Junhui Hu, Weijia Shao

    Planar hot-electron photodetectors (HE PDs) often operate at specified working wavelengths at which devices exhibit high optical absorption efficiencies. Recently, several planar HE PDs with strong optical absorptions across broad wavelength ranges have been demonstrated. However, the studies about spectral tunability of broadband HE PDs remain scarce and planar hot-electron photodetection with customized spectral linewidths are still absent. Herein, we propose a Tamm plasmon (TP) design of planar, broadband, and tunable HE PDs that have a thin Cr film on a distributed Bragg reflector. Optical investigations show that the thickness of dielectric layer adjacent to Cr layer is a critical factor in determining TP-induced optical responses, including prominent anti-reflection characteristic and broadband strong absorption in the Cr layer. Subsequent electrical analysis verify that device electrical spectra are strongly related to the thickness of critical dielectric layer that have great effects on spectral properties about electronic processes. Comparison studies between the designed Cr-involved device and referenced Au-involved device highlight the superiority of the designed device in high average responsivity and variable broad linewidth.


  • Highly Sensitive PCF Sensor Based on Au-TiO2 for Cancer Cell Detection

    by Qiunan Zhang, Can'ER Cheng, Chuanyang Huang, Xiangyu Liao, Yongmei Wang, Jian Tang, Junhui Hu, Weijia Shao, Jun Liu

    This study introduces a bilaterally polished D-shaped surface plasmon resonance sensor based on Au-TiO2 for early detection of cancer cells. The refractive indices of the six different types of normal and cancer cells detected ranged from 1.36 ~ 1.401. The finite element method is used for numerical analysis. The spectral interrogation method is used to detect the refractive index variations of cancer cells. According to numerical results, blood cancer has the highest wavelength sensitivity (23643 nm/RIU) in the structure of the optimal parameters. The wavelength sensitivities for the rest of the cancer cells are 10150 nm/RIU for skin cancer basal cells, 18291 nm/RIU for cervical cancer HeLa cells, 20642 nm/RIU for adrenal gland cancer PC 12 cells, 13142 nm/RIU for breast cancer type 1 MDA-MB-231 cells and 9142 nm/RIU breast cancer type 2 MCF-7 cells. Moreover, the FOM reaches a maximum of 382.28 /RIU with a maximum resolution of 4.23×10-6 RIU. Compared to related studies, the sensor design exhibits superior sensitivity, resolution, and figure of merit, making it highly beneficial for medical applications in cancer detection.


  • Research on D-shape PCF temperature sensor with simple structure and high sensitivity

    by Qiunan Zhang, Zhao Zhang, Can’eR Cheng, Chuanyang Huang, Xiangyu Liao, Jian Tang, Junhui Hu, Yongmei Wang, Weijia Shao