Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreia T. Pereira has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Embedded 3D Printing of Graphene Oxide‐Containing, Chemically Crosslinkable Poly(Ethylene Glycol) Inks

    by Helena P. Ferreira, Monize C. Decarli, Duarte Moura, Rúben F. Pereira, Andreia T. Pereira, Lorenzo Moroni, Inês C. Gonçalves

    The incorporation of graphene‐based materials into hydrogels enhances their mechanical, electroconductive, and antimicrobial properties, offering significant potential for biomedical applications. However, 3D printing graphene‐containing inks may present challenges because of their unsuitable shape retention or the fact that the concentration of the graphene component can hinder photocrosslinking. This study explores embedded 3D printing to process a chemically crosslinkable poly(ethylene glycol) ink with a high (4% w/v) graphene oxide concentration (PEG/GO). Given the PEG/GO ink's insufficient shape retention and slow crosslinking, various support baths are screened, with the microparticulate bath of the crystal self‐healing embedding bioprinting (CLADDING) method proving most effective. The interstitial solution of the CLADDING bath influences the mechanical properties of printed PEG/GO constructs. Multilayered PEG/GO cylindrical constructs with <500 μm filament width and up to 4.5 mm height (30 layers) are fabricated, presenting better tensile properties when printed within CLADDING in calcium chloride (vs. baths in crosslinking initiators). The surface of PEG/GO constructs is anti‐adhesive toward human foreskin fibroblasts, and their extracts are cytocompatible. Hence, embedded 3D printing emerges as an innovative strategy to surpass limitations of shaping graphene‐containing hydrogels into complex geometries, broadening the biomanufacturing possibilities for diverse biomedical applications requiring kPa‐range mechanical properties.

  • Open Access

    Using Graphene-Based Materials for Stiff and Strong Poly(ethylene glycol) Hydrogels

    by Helena P. Ferreira, Duarte Moura, Andreia T. Pereira, Patrícia C. Henriques, Cristina C. Barrias, Fernão D. Magalhães, Inês C. Gonçalves

    Blood-contacting devices are increasingly important for the management of cardiovascular diseases. Poly(ethylene glycol) (PEG) hydrogels represent one of the most explored hydrogels to date. However, they are mechanically weak, which prevents their use in load-bearing biomedical applications (e.g., vascular grafts, cardiac valves). Graphene and its derivatives, which have outstanding mechanical properties, a very high specific surface area, and good compatibility with many polymer matrices, are promising candidates to solve this challenge. In this work, we propose the use of graphene-based materials as nanofillers for mechanical reinforcement of PEG hydrogels, and we obtain composites that are stiffer and stronger than, and as anti-adhesive as, neat PEG hydrogels. Results show that single-layer and few-layer graphene oxide can strengthen PEG hydrogels, increasing their stiffness up to 6-fold and their strength 14-fold upon incorporation of 4% w/v (40 mg/mL) graphene oxide. The composites are cytocompatible and remain anti-adhesive towards endothelial cells, human platelets and Staphylococcus aureus, similar to neat hydrogels. To the best of our knowledge, this is the first work to report such an increase of the tensile properties of PEG hydrogels using graphene-based materials as fillers. This work paves the way for the exploitation of PEG hydrogels as a backbone material for load-bearing applications.


  • Graphene-based materials: the key for the successful application of pHEMA as a blood-contacting device

    by Andreia T. Pereira, Patrícia C. Henriques, Karl H. Schneider, Ana L. Pires, André M. Pereira, Maria Cristina L. Martins, Fernão D. Magalhães, Helga Bergmeister, Inês C. Gonçalves

    Thrombosis and infection are the leading causes of blood-contacting device (BCD) failure, mainly due to the poor performance of existing biomaterials. Poly(2-hydroxyethyl methacrylate) (pHEMA) has excellent hemocompatibility but the weak mechanical properties impair its use as a bulk material for BCD. As such, pHEMA has been explored as a coating, despite the instability and difficulty of attachment to the underlying polymer compromise its success. This work describes the hydrogel composites made of pHEMA and graphene-based materials (GBM) that meet the biological and mechanical requirements for a stand-alone BCD. Five GBM differing in thickness, oxidation degree, and lateral size were incorporated in pHEMA, revealing that only oxidized-GBM can reinforce pHEMA. pHEMA/oxidized-GBM composites are cytocompatible and prevent the adhesion of endothelial cells, blood platelets, and bacteria (S. aureus), thus maintaining pHEMA's anti-adhesive properties. As a proof of concept, the thrombogenicity of the tubular prototypes of the best formulation (pHEMA/Graphene oxide (GO)) was evaluated in vivo, using a porcine arteriovenous-shunt model. pHEMA/GO conduits withstand the blood pressure and exhibit negligible adhesion of blood components, revealing better hemocompatibility than ePTFE, a commercial material for vascular access. Our findings reveal pHEMA/GO, a synthetic and off-the-shelf hydrogel, as a preeminent material for the design of blood-contacting devices that prevent thrombosis and bacterial adhesion.


  • Benchmarking of density functionals for the kinetics and thermodynamics of the hydrolysis of glycosidic bonds catalyzed by glycosidases

    by Andreia T. Pereira, António J. M. Ribeiro, Pedro A. Fernandes, Maria J. Ramos

    In recent years, there has been an increased interest in understanding the enzymatic mechanism of glycosidases resorting mostly to DFT and DFT/MM calculations. However, the performance of density functionals (DFs) is well known to be system and property dependent. Trends drawn from general studies, despite important to evaluate the quality of the DFs and to pave the way for the development of new DFs, may be misleading when applied to a single specific system/property. To overcome this issue, we carried out a benchmarking study of 40 DFs applied to the geometry optimization and to the electronic barrier height (EBarrier) and electronic energy of reaction (ER) of prototypical glycosidase‐catalyzed reactions. Additionally, we report calculations with SCC‐DFTB and four semiempirical MO methods applied to the same problem. We have used a universal molecular model for retaining glycosidases, comprising only a 22‐atoms system that mimics the active site and substrate. High accuracy reference geometries and energies were calculated at the CCSD(T)/CBS//MP2/aug‐cc‐pVTZ level of theory. Most DFs reproduce the reference geometries extremely well, with mean unsigned errors (MUE) smaller than 0.05 Å for bond lengths and 3° for bond angles. Among the DFs, wB97X‐D, CAM‐B3LYP, B3P86, and PBE1PBE have the best performance in geometry optimizations (MUE = 0.02 Å). Conversely, semiempirical MO and SCC‐DFTB methods yielded less accurate geometries (MUE between 0.09 and 0.17 Å). The inclusion of D3 correction has a small, but still relevant, influence in the geometry predicted by some DFs. Regarding EBarrier, 11 DFs (MPW1B95, CAM‐B3LYP, M06 ‐ 2X, PBE1PBE, wB97X ‐ D, B1B95, BMK, MN12 – SX, M05, M06, and M11) presented errors below 1 kcal.mol−1, in relation to the reference energy. Most of these functionals belong to the family of hybrid functionals (H‐GGA, HH‐GGA, and HM‐GGA), which shows a positive influence of HF exchange in the determination of EBarrier. The inclusion of D3 correction has not affected significantly the EBarrier and ER. The use of geometries at the accurate but expensive MP2/aug‐cc‐pVTZ level of theory has a small, albeit not insignificant, influence in the EBarrier when compared with energies calculated with geometries determined with the DFs (usually a few tenths of kcal.mol−1, with exceptions). In general, semiempirical MO methods and DFTB are associated with larger errors in the determination of EBarrier, with unsigned errors from 6.9 to 24.7 kcal.mol−1.