Shujing Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shujing Lin has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Daxiang Cui
School of Electronic Information and Electrical Engineering Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument Key Lab. for Thin Film and Microfabrication Technology of Ministry of Education Shanghai Jiao Tong University Shanghai 200240 P. R. China
5 shared publicationsDi Chen
5 shared publications- Jiaqi Niu
Institute of Intelligent Health Diagnosis and Treatment, School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China
5 shared publications Yanlei Liu
5 shared publications- Daxiang Cui
Medical and Engineering Cross Research Institute, The First Affiliated Hospital of Henan University, Kaifeng, China
4 shared publications - Di Chen
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
4 shared publications
Latest Publications
- 23 April 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 462
An integrated microfluidic platform for exosome efficient separation and drug loading
- 23 April 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 462
An integrated microfluidic platform for exosome efficient separation and drug loading
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Reflective Grating Linear Encoder Based on Moiré Signals Reconstruction and Arctangent Subdivision Method
In the research of linear displacement sensors, the primary focus has been on displacement sensors based on gratings. However, the limitation of grating pitch and the substantial noise inherently present in the original Moiré signals from gratings seriously affect the accuracy of grating displacement sensors. Therefore, this paper proposes a grating displacement measurement method based on Moiré signal reconstruction and arctangent subdivision to improve the accuracy of grating displacement sensors. First, improvements were made to the least mean square (LMS) algorithm and coordinate rotation digital computer (CORDIC) algorithm, which are essential for Moiré signals reconstruction method. Based on these enhanced algorithms, the Moiré signals reconstruction process was developed to improve signal quality, and the arctangent subdivision method was employed to subdivide the Moiré signals. Finally, the effectiveness of the Moiré signal reconstruction method was verified through a built performance test platform for linear displacement sensors, and the accuracy of the linear displacement sensors was tested. Experimental results show that the subdivision errors before and after Moiré signals reconstruction are 1.985 rad and 0.157 rad, respectively. The system's measurement accuracy is within 1 μm, and both repeatability and reproducibility errors are less than 0.6 μm.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Reflective Grating Linear Encoder Based on Moiré Signals Reconstruction and Arctangent Subdivision Method
In the research of linear displacement sensors, the primary focus has been on displacement sensors based on gratings. However, the limitation of grating pitch and the substantial noise inherently present in the original Moiré signals from gratings seriously affect the accuracy of grating displacement sensors. Therefore, this paper proposes a grating displacement measurement method based on Moiré signal reconstruction and arctangent subdivision to improve the accuracy of grating displacement sensors. First, improvements were made to the least mean square (LMS) algorithm and coordinate rotation digital computer (CORDIC) algorithm, which are essential for Moiré signals reconstruction method. Based on these enhanced algorithms, the Moiré signals reconstruction process was developed to improve signal quality, and the arctangent subdivision method was employed to subdivide the Moiré signals. Finally, the effectiveness of the Moiré signal reconstruction method was verified through a built performance test platform for linear displacement sensors, and the accuracy of the linear displacement sensors was tested. Experimental results show that the subdivision errors before and after Moiré signals reconstruction are 1.985 rad and 0.157 rad, respectively. The system's measurement accuracy is within 1 μm, and both repeatability and reproducibility errors are less than 0.6 μm.
- Open Access
- 2 January 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (1) , 167-198
Microfluidic-based electrically driven particle manipulation techniques for biomedical applications
Microfluidic chips exhibit unique advantages in both economy and rapidity, particularly for the separation and detection of biomolecules.
- 2 January 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (1) , 167-198
Open AccessMicrofluidic-based electrically driven particle manipulation techniques for biomedical applications
Microfluidic chips exhibit unique advantages in both economy and rapidity, particularly for the separation and detection of biomolecules.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (1) , 111-114
Foam-Structured Strain Sensor-Based Elastic Wearable System for Pulse Wave Detection
Timely detection of abnormal pulse wave conditions can provide early warnings for cardiovascular emergencies. Strain sensors can detect subtle pulse wave changes, however, they often face a trade-off between flexibility and accuracy. Herein, we present a cost-effective, high-sensitivity elastic strain sensor based on foam-structured silicone rubber@nanocarbon black (SR@CB). The sensor exhibits excellent linearity within a strain range of 0-60%, with a detection sensitivity of 0.1% and a gauge factor of up to 32. Thus, it can detect not only subtle pulse wave signals, but also be used for motion monitoring. Moreover, we have developed an elastic circuit detection system prototype, significantly enhancing wearer comfort while achieving a fully elastic detection system. We foresee this fully elastic detection system holds promise for health monitoring and motion detection applications.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (1) , 111-114
Foam-Structured Strain Sensor-Based Elastic Wearable System for Pulse Wave Detection
Timely detection of abnormal pulse wave conditions can provide early warnings for cardiovascular emergencies. Strain sensors can detect subtle pulse wave changes, however, they often face a trade-off between flexibility and accuracy. Herein, we present a cost-effective, high-sensitivity elastic strain sensor based on foam-structured silicone rubber@nanocarbon black (SR@CB). The sensor exhibits excellent linearity within a strain range of 0-60%, with a detection sensitivity of 0.1% and a gauge factor of up to 32. Thus, it can detect not only subtle pulse wave signals, but also be used for motion monitoring. Moreover, we have developed an elastic circuit detection system prototype, significantly enhancing wearer comfort while achieving a fully elastic detection system. We foresee this fully elastic detection system holds promise for health monitoring and motion detection applications.
- 4 November 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (2) , 740-773
Microneedles: multifunctional devices for drug delivery, body fluid extraction, and bio-sensing
Used in drug delivery, body-fluid extraction, and bio-sensing, microneedle-based devices provide a novel perspective to overcome the traditional limits of biomedical engineering.
- 4 November 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (2) , 740-773
Microneedles: multifunctional devices for drug delivery, body fluid extraction, and bio-sensing
Used in drug delivery, body-fluid extraction, and bio-sensing, microneedle-based devices provide a novel perspective to overcome the traditional limits of biomedical engineering.
- 9 October 2024
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 8 (23) , 3925-3934
Au-based conjugated microporous polymers for combined photodynamic and radiation therapy in cancer treatment
Radiotherapy (RT) is a cornerstone of cancer treatment, and the radiation dose is the key factor determining its lethality. However, achieving ideal therapeutic effects requires balancing the radiation tolerance of tumor cells and the damage to surrounding healthy tissues by selecting the optimal radiation dose. Herein, we developed gold-coordinated porphyrin conjugated microporous polymers (Au-CMP) as novel radiosensitizers, aiming to achieve optimal therapeutic effects at low radiation doses. These polymers were synthesized and PEGylated to form nanoparticles (Au-CMP NPs) that enhance both photodynamic therapy (PDT) and RT by utilizing porphyrin structures for efficient singlet oxygen generation and superior radiation absorption by the high-Z element Au. In vivo studies with BEL-7402 tumor-bearing mice have confirmed that under the mediation of Au-CMP NPs, even a low dose of X-ray irradiation can exhibit significant tumor suppression effects. Furthermore, when combined with PDT, tumor proliferation is further inhibited, a finding that has also been validated in cellular experiments through increased DNA damage and reactive oxygen species generation. This research underscores the potential of Au-CMP NPs as a multifunctional, biodegradable platform to improve cancer treatment outcomes through integrated PDT and RT. The innovative approach of integrating Au-CMP NPs into cancer therapy may pave the way for more effective and less invasive treatment options, ultimately benefiting patients directly.
- 9 October 2024
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 8 (23) , 3925-3934
Au-based conjugated microporous polymers for combined photodynamic and radiation therapy in cancer treatment
Radiotherapy (RT) is a cornerstone of cancer treatment, and the radiation dose is the key factor determining its lethality. However, achieving ideal therapeutic effects requires balancing the radiation tolerance of tumor cells and the damage to surrounding healthy tissues by selecting the optimal radiation dose. Herein, we developed gold-coordinated porphyrin conjugated microporous polymers (Au-CMP) as novel radiosensitizers, aiming to achieve optimal therapeutic effects at low radiation doses. These polymers were synthesized and PEGylated to form nanoparticles (Au-CMP NPs) that enhance both photodynamic therapy (PDT) and RT by utilizing porphyrin structures for efficient singlet oxygen generation and superior radiation absorption by the high-Z element Au. In vivo studies with BEL-7402 tumor-bearing mice have confirmed that under the mediation of Au-CMP NPs, even a low dose of X-ray irradiation can exhibit significant tumor suppression effects. Furthermore, when combined with PDT, tumor proliferation is further inhibited, a finding that has also been validated in cellular experiments through increased DNA damage and reactive oxygen species generation. This research underscores the potential of Au-CMP NPs as a multifunctional, biodegradable platform to improve cancer treatment outcomes through integrated PDT and RT. The innovative approach of integrating Au-CMP NPs into cancer therapy may pave the way for more effective and less invasive treatment options, ultimately benefiting patients directly.
The Evolution of Microfluidic‐Based Drug‐Loading Techniques for Cells and Their Derivatives
Conventional drug delivery techniques face challenges related to targeting and adverse reactions. Recent years have witnessed significant advancements in nanoparticle‐based drug carriers. Nevertheless, concerns persist regarding their safety and insufficient metabolism. Employing cells and their derivatives, such as cell membranes and extracellular vesicles (EVs), as drug carriers effectively addresses the challenges associated with nanoparticle carriers. However, an essential hurdle remains in efficiently loading drugs into these carriers. With the advancement of microfluidic technology and its advantages in precise manipulation at the micro‐ and nanoscales, as well as minimal sample loss, it has found extensive application in the loading of drugs using cells and their derivatives, thereby fostering the development of drug‐loading techniques. This paper outlines the characteristics and benefits of utilizing cells and their derivatives as drug carriers and provides an overview of current drug‐loading techniques, particularly those rooted in microfluidic technology. The significant potential for microfluidic technology in targeted disease therapy through drug delivery systems employing cells and their derivatives, is foreseen.
The Evolution of Microfluidic‐Based Drug‐Loading Techniques for Cells and Their Derivatives
Conventional drug delivery techniques face challenges related to targeting and adverse reactions. Recent years have witnessed significant advancements in nanoparticle‐based drug carriers. Nevertheless, concerns persist regarding their safety and insufficient metabolism. Employing cells and their derivatives, such as cell membranes and extracellular vesicles (EVs), as drug carriers effectively addresses the challenges associated with nanoparticle carriers. However, an essential hurdle remains in efficiently loading drugs into these carriers. With the advancement of microfluidic technology and its advantages in precise manipulation at the micro‐ and nanoscales, as well as minimal sample loss, it has found extensive application in the loading of drugs using cells and their derivatives, thereby fostering the development of drug‐loading techniques. This paper outlines the characteristics and benefits of utilizing cells and their derivatives as drug carriers and provides an overview of current drug‐loading techniques, particularly those rooted in microfluidic technology. The significant potential for microfluidic technology in targeted disease therapy through drug delivery systems employing cells and their derivatives, is foreseen.
A Fully Elastic Wearable Electrochemical Sweat Detection System of Tree‐Bionic Microfluidic Structure for Real‐Time Monitoring
Fresh sweat contains a diverse range of physiological indicators that can effectively reflect changes in the body. However, existing wearable sweat detection systems face challenges in efficiently collecting and detecting fresh sweat in real‐time. Additionally, they often lack the necessary deformation capabilities, resulting in discomfort for the wearer. Here, a fully elastic wearable electrochemical sweat detection system is developed that integrates a sweat‐collecting microfluidic chip, a multi‐parameter electrochemical sensor, a micro‐heater, and a sweat detection elastic circuit board system. The unique tree‐bionic structure of the microfluidic chip significantly enhances the efficiency of fresh sweat collection and discharge, enabling real‐time detection by the electrochemical sensors. The sweat multi‐parameter electrochemical sensor offers high‐precision and high‐sensitivity measurements of sodium ions, potassium ions, lactate, and glucose. The electronic system is built on an elastic circuit board that matches perfectly to wrinkled skin, ensuring improved wearing comfort and enabling multi‐channel data sampling, processing, and wireless transmission. This state‐of‐the‐art system represents a significant advancement in the field of elastic wearable sweat detection and holds promising potential for extending its capabilities to the detection of other sweat markers or various wearable applications.
A Fully Elastic Wearable Electrochemical Sweat Detection System of Tree‐Bionic Microfluidic Structure for Real‐Time Monitoring
Fresh sweat contains a diverse range of physiological indicators that can effectively reflect changes in the body. However, existing wearable sweat detection systems face challenges in efficiently collecting and detecting fresh sweat in real‐time. Additionally, they often lack the necessary deformation capabilities, resulting in discomfort for the wearer. Here, a fully elastic wearable electrochemical sweat detection system is developed that integrates a sweat‐collecting microfluidic chip, a multi‐parameter electrochemical sensor, a micro‐heater, and a sweat detection elastic circuit board system. The unique tree‐bionic structure of the microfluidic chip significantly enhances the efficiency of fresh sweat collection and discharge, enabling real‐time detection by the electrochemical sensors. The sweat multi‐parameter electrochemical sensor offers high‐precision and high‐sensitivity measurements of sodium ions, potassium ions, lactate, and glucose. The electronic system is built on an elastic circuit board that matches perfectly to wrinkled skin, ensuring improved wearing comfort and enabling multi‐channel data sampling, processing, and wireless transmission. This state‐of‐the‐art system represents a significant advancement in the field of elastic wearable sweat detection and holds promising potential for extending its capabilities to the detection of other sweat markers or various wearable applications.
- Open Access
- 2 August 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (17) , 3277
Correction: Recent advances in microfluidic-based electroporation techniques for cell membranes
Correction for ‘Recent advances in microfluidic-based electroporation techniques for cell membranes’ by Fei Wang et al., Lab Chip, 2022, 22, 2624–2646, https://doi.org/10.1039/D2LC00122E.
- 2 August 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (17) , 3277
Open AccessCorrection: Recent advances in microfluidic-based electroporation techniques for cell membranes
Correction for ‘Recent advances in microfluidic-based electroporation techniques for cell membranes’ by Fei Wang et al., Lab Chip, 2022, 22, 2624–2646, https://doi.org/10.1039/D2LC00122E.