Shiqin Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiqin Jiang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Chen Zhao
Tongji Univ, Coll Elect & Informat Engn, Shanghai 201804, Peoples R China
4 shared publicationsDietrich Grönemeyer
University Witten/Herdecke
2 shared publicationsLu Bing
Department of Control Science and Engineering, School of Electronics and Information Engineering, Tongji University, Shanghai 201804, China
2 shared publicationsMengpei Chen
Department of Control Science and Engineering, School of Electronics and Information Engineering, Tongji University, Shanghai 201804, China
2 shared publications- Peter Van Leeuwen
University Witten/Herdecke
2 shared publications B Hailer
Department of Internal Medicine, Philippusstift, University Witten/Herdecke, Essen, Germany
1 shared publication
Latest Publications
- 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (13) , 138701-138701-14
Current source reconstructing and magnetic imaging of cardiac electrical activity during P-wave
用超导量子干涉仪在人体胸腔表面测量的磁场数据重建心脏电流源及其成像, 是一种无创获取心脏电活动信息的新技术. 由于P波间期的心脏磁信号比R波峰值弱, 信噪比较低, 本文提出了一种可提高分布源空间谱估计强度对比度(IIC)的波束成形方法. 该方法分两步: 1)在空间滤波器的加权矩阵中引入导联场矩阵, 使滤波器输出估计对磁场电流源及其分布比较敏感. 通过求解逆问题, 可以改进重建分布源强度的对比度; 2)通过设置源强度阈值, 提取每个时刻重建源中偶极矩强度极大的电流源, 消除其他位置上相对弱的伪源, 可提高P波间期电流源重建的精度. 文中采用理论分析与仿真试验, 比较了IIC与3种其他电流源重建方法的性能. 结果表明, IIC的单源空间谱估计的强度对比度较高, 电流源重建精度相对较好. 文中还分析了2个健康人的61通道心磁测量数据, 以及他们P波间期的心脏电活动成像. 与其他3种方法相比, IIC的电流源成像结果最优. 能够显示健康人P波峰时刻心房的电活动较心室强. P波间期右心房除极时, 心脏电活动具有方向特征.
- 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (13) , 138701-138701-14
Current source reconstructing and magnetic imaging of cardiac electrical activity during P-wave
用超导量子干涉仪在人体胸腔表面测量的磁场数据重建心脏电流源及其成像, 是一种无创获取心脏电活动信息的新技术. 由于P波间期的心脏磁信号比R波峰值弱, 信噪比较低, 本文提出了一种可提高分布源空间谱估计强度对比度(IIC)的波束成形方法. 该方法分两步: 1)在空间滤波器的加权矩阵中引入导联场矩阵, 使滤波器输出估计对磁场电流源及其分布比较敏感. 通过求解逆问题, 可以改进重建分布源强度的对比度; 2)通过设置源强度阈值, 提取每个时刻重建源中偶极矩强度极大的电流源, 消除其他位置上相对弱的伪源, 可提高P波间期电流源重建的精度. 文中采用理论分析与仿真试验, 比较了IIC与3种其他电流源重建方法的性能. 结果表明, IIC的单源空间谱估计的强度对比度较高, 电流源重建精度相对较好. 文中还分析了2个健康人的61通道心磁测量数据, 以及他们P波间期的心脏电活动成像. 与其他3种方法相比, IIC的电流源成像结果最优. 能够显示健康人P波峰时刻心房的电活动较心室强. P波间期右心房除极时, 心脏电活动具有方向特征.
- 1 January 2018
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 67 (15) , 158702
The method of suppressing spatial filter output noise-power gain for cardiac electrical activity imaging
利用人体表面测量的心脏磁场数据无创成像心脏电活动,需要解决的关键问题是提高其重建分布电流源偶极矩强度的分辨率.本文在最小方差波束成形(MVB)方法的基础上,提出了一种可抑制空间滤波器输出噪声功率增益(SONG)的波束成形方法,目的是通过构造一种新的滤波器权矩阵,约束空间滤波器的输出噪声功率增益,提高重建分布电流源偶极矩强度的分辨率,即分布电流源空间谱估计的源分辨能力,从而增强心脏电活动磁成像的分辨率.文中给出了电流源重建的理论分析和仿真结果;比较了该方法与MVB方法的差别;并给出了两个健康人36通道心脏磁场数据的电活动成像.结果表明,SONG方法分辨电流源的能力较强,能够观察到心脏电磁场信号R峰时刻健康人的心室电活动较强,心房电活动较弱等特征
- 1 January 2018
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 67 (15) , 158702
The method of suppressing spatial filter output noise-power gain for cardiac electrical activity imaging
利用人体表面测量的心脏磁场数据无创成像心脏电活动,需要解决的关键问题是提高其重建分布电流源偶极矩强度的分辨率.本文在最小方差波束成形(MVB)方法的基础上,提出了一种可抑制空间滤波器输出噪声功率增益(SONG)的波束成形方法,目的是通过构造一种新的滤波器权矩阵,约束空间滤波器的输出噪声功率增益,提高重建分布电流源偶极矩强度的分辨率,即分布电流源空间谱估计的源分辨能力,从而增强心脏电活动磁成像的分辨率.文中给出了电流源重建的理论分析和仿真结果;比较了该方法与MVB方法的差别;并给出了两个健康人36通道心脏磁场数据的电活动成像.结果表明,SONG方法分辨电流源的能力较强,能够观察到心脏电磁场信号R峰时刻健康人的心室电活动较强,心房电活动较弱等特征
- 6 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (2) , 495-502
An Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
We present a new approach of integrated maximum current density (IMCD) for the noninvasive detection of myocardial infarction (MI) using magnetocardiography (MCG) data acquired from a superconducting quantum interference device (SQUID) system. In this paper, we investigated the relationship of the maximum current density (MCD) in the current density map and the underlying equivalent current dipole (ECD) based on a novel method of reconstructing the ECD in the extremum circle of the magnetic field map. The performance of IMCD and the integrated ECD (IECD) approaches were also evaluated by using 61-channel MCG data from 39 healthy subjects and 102 patients with ST elevation myocardial infarction (STEMI). Statistical analysis of the healthy and STEMI groups demonstrate that the IMCD approach obtains sensitivity and specificity up to 91.2% and 84.6%, somewhat higher than that of IECD, respectively. The results indicate that IMCD provides spatiotemporal information regarding cardiac electrical activity during ventricular repolarization. This approach may be helpful to diagnose MI in clinic application. The physical concept of the approach is also explained in this paper.
- 6 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (2) , 495-502
An Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
We present a new approach of integrated maximum current density (IMCD) for the noninvasive detection of myocardial infarction (MI) using magnetocardiography (MCG) data acquired from a superconducting quantum interference device (SQUID) system. In this paper, we investigated the relationship of the maximum current density (MCD) in the current density map and the underlying equivalent current dipole (ECD) based on a novel method of reconstructing the ECD in the extremum circle of the magnetic field map. The performance of IMCD and the integrated ECD (IECD) approaches were also evaluated by using 61-channel MCG data from 39 healthy subjects and 102 patients with ST elevation myocardial infarction (STEMI). Statistical analysis of the healthy and STEMI groups demonstrate that the IMCD approach obtains sensitivity and specificity up to 91.2% and 84.6%, somewhat higher than that of IECD, respectively. The results indicate that IMCD provides spatiotemporal information regarding cardiac electrical activity during ventricular repolarization. This approach may be helpful to diagnose MI in clinic application. The physical concept of the approach is also explained in this paper.
- Open Access
- 21 September 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 633 (1) , 012138
A Fast Greedy Sparse Method of Current Sources Reconstruction for Ventricular Torsion Detection
A fast greedy sparse (FGS) method of cardiac equivalent current sources reconstruction is developed for non-invasive detection and quantitative analysis of individual left ventricular torsion. The cardiac magnetic field inverse problem is solved based on a distributed source model. The analysis of real 61-channel magnetocardiogram (MCG) data demonstrates that one or two dominant current source with larger strength can be identified efficiently by the FGS algorithm. Then, the left ventricle torsion during systole is examined on the basis of x, y and z coordination curves and angle change of reconstructed dominant current sources. The advantages of this method are non-invasive, visible, with higher sensitivity and resolution. It may enable the clinical detection of cardiac systolic and ejection dysfunction.
- 21 September 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 633 (1) , 012138
Open AccessA Fast Greedy Sparse Method of Current Sources Reconstruction for Ventricular Torsion Detection
A fast greedy sparse (FGS) method of cardiac equivalent current sources reconstruction is developed for non-invasive detection and quantitative analysis of individual left ventricular torsion. The cardiac magnetic field inverse problem is solved based on a distributed source model. The analysis of real 61-channel magnetocardiogram (MCG) data demonstrates that one or two dominant current source with larger strength can be identified efficiently by the FGS algorithm. Then, the left ventricle torsion during systole is examined on the basis of x, y and z coordination curves and angle change of reconstructed dominant current sources. The advantages of this method are non-invasive, visible, with higher sensitivity and resolution. It may enable the clinical detection of cardiac systolic and ejection dysfunction.
- 1 July 2015
- Published by Elsevier in Science Bulletin
- Vol. 60 (14) , 1235-1240
Sparse current source reconstruction in MCG
- 1 July 2015
- Published by Elsevier in Science Bulletin
- Vol. 60 (14) , 1235-1240
Sparse current source reconstruction in MCG
- 28 February 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (11) , 1123-1128
Noninvasively diagnosing coronary artery disease with 61-channel MCG data
- 28 February 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (11) , 1123-1128
Noninvasively diagnosing coronary artery disease with 61-channel MCG data
- 1 January 2014
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 63 (7) , 078702
Equivalent source reconstruction in inhomogeneous electromagnetic media
本文提出了一种用于等效源重构的磁场极值信号法. 并通过给定不同的电流偶极子作为信号源,仿真研究了多腔体心脏磁场模型及非均匀介质情况下等效源重构的精度. 分析了体电导对心脏磁场的影响,以及磁场极值信号反映的体电导作用. 文中将该方法与其他四种源估计方法:磁场梯度极值法、Nelder-Mead单纯形算法、信赖域反射算法和粒子群优化算法作了比较. 分析了这些方法的源重构精度和计算所需时间. 结果表明,这种针对非均匀介质情况提出的心脏磁场逆问题求解方法有一定的实用价值.
- 1 January 2014
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 63 (7) , 078702
Equivalent source reconstruction in inhomogeneous electromagnetic media
本文提出了一种用于等效源重构的磁场极值信号法. 并通过给定不同的电流偶极子作为信号源,仿真研究了多腔体心脏磁场模型及非均匀介质情况下等效源重构的精度. 分析了体电导对心脏磁场的影响,以及磁场极值信号反映的体电导作用. 文中将该方法与其他四种源估计方法:磁场梯度极值法、Nelder-Mead单纯形算法、信赖域反射算法和粒子群优化算法作了比较. 分析了这些方法的源重构精度和计算所需时间. 结果表明,这种针对非均匀介质情况提出的心脏磁场逆问题求解方法有一定的实用价值.