Gitte Slingers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gitte Slingers has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Marc Raes
Universiteit Hasselt Faculteit Geneeskunde en Levenswetenschappen
5 shared publicationsEddy Goelen
VITO NV
3 shared publicationsGudrun Koppen
VITO NV
3 shared publicationsMaarten Spruyt
VITO NV
3 shared publications- Gudrun Koppen
VITO Health, Flemish Institute for Technological Research (VITO), 2400 Mol, Belgium
2 shared publications Ibbo Willems
Flemish Institute for Technological Research
2 shared publications
Latest Publications
- Open Access
- 7 August 2023
- Published by Wiley
Exhaled volatile biomarkers for differentiating noisy breathing infants: a pilot study
Background Early differentiation of rattling infants, frequently misdiagnosed as wheezing, is important to prevent under- and overtreatment. Exhaled breath biomarkers reflect metabolic processes and can potentially aid differential diagnosis. This study investigated the potential of exhaled biomarkers in differentiating rattling infants. Methods Exhaled breath collected from infants (2-18months) with an adjusted breath sampler was analysed using gas chromatography mass spectrometry (GC-MS) and selected ion flow tube mass spectrometry (SIFT-MS). Linear discriminant analysis was used to classify recovered, mild, moderate and severe rattling infants in a one-vs-all approach. The potential of parent reported outcome about symptoms and burden to improve the discriminant models was also investigated. Results Classifying the diagnostic groups (recovered, mild, moderate, severe rattling) based on exhaled breath showed potential with accuracies between 69.12-75.0% for GC-MS and 59.21-69.74% for SIFT-MS. Highest accuracy and specificity was achieved for severe rattling vs all other diagnostic groups. Adding parent reported symptoms in past the three days to the discriminant model increased accuracies (69.12-86.76% GC-MS; 65.79-88.16% SIFT-MS), particularly for moderate and severe rattling infants. The differentiating VOCs were of the type alkane, acids, amine, imine, triazine and ketone. Conclusion Exhaled breath analysis has potential to differentiate infants with different rattling severities and recovered infants. Additionally, combining parent reported symptoms in the past three days with exhaled breath biomarkers improved the performance of the diagnostic models.
- 7 August 2023
- Published by Wiley
Open AccessExhaled volatile biomarkers for differentiating noisy breathing infants: a pilot study
Background Early differentiation of rattling infants, frequently misdiagnosed as wheezing, is important to prevent under- and overtreatment. Exhaled breath biomarkers reflect metabolic processes and can potentially aid differential diagnosis. This study investigated the potential of exhaled biomarkers in differentiating rattling infants. Methods Exhaled breath collected from infants (2-18months) with an adjusted breath sampler was analysed using gas chromatography mass spectrometry (GC-MS) and selected ion flow tube mass spectrometry (SIFT-MS). Linear discriminant analysis was used to classify recovered, mild, moderate and severe rattling infants in a one-vs-all approach. The potential of parent reported outcome about symptoms and burden to improve the discriminant models was also investigated. Results Classifying the diagnostic groups (recovered, mild, moderate, severe rattling) based on exhaled breath showed potential with accuracies between 69.12-75.0% for GC-MS and 59.21-69.74% for SIFT-MS. Highest accuracy and specificity was achieved for severe rattling vs all other diagnostic groups. Adding parent reported symptoms in past the three days to the discriminant model increased accuracies (69.12-86.76% GC-MS; 65.79-88.16% SIFT-MS), particularly for moderate and severe rattling infants. The differentiating VOCs were of the type alkane, acids, amine, imine, triazine and ketone. Conclusion Exhaled breath analysis has potential to differentiate infants with different rattling severities and recovered infants. Additionally, combining parent reported symptoms in the past three days with exhaled breath biomarkers improved the performance of the diagnostic models.
- 26 February 2023
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 22 (5) , 888-893
Exhaled breath profiles to detect lung infection with Staphylococcus aureus in children with cystic fibrosis
- 26 February 2023
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 22 (5) , 888-893
Exhaled breath profiles to detect lung infection with Staphylococcus aureus in children with cystic fibrosis
- 30 October 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (4) , e8994
Real‐time versus thermal desorption selected ion flow tube mass spectrometry for quantification of breath volatiles
Rationale: Selected ion flow tube mass spectrometry (SIFT‐MS) is versatile, rapidly provides result output and determines a wide range of volatiles, making it suitable for biomedical applications. When direct sampling into the SIFT‐MS instrument is impractical, combining thermal desorption (TD) and SIFT‐MS might offer a solution as it allows sample storage on sorbent tubes for later analysis. This work compares off‐line TD SIFT‐MS and real‐time SIFT‐MS for the quantification of selected breath volatiles. Methods: Ten healthy non‐smoking individuals provided 60 breath samples per method. For off‐line analysis, breath was collected onto sorbent tubes via a breath sampler provided with filtered inspiratory air. After TD, samples were re‐collected in Tedlar bags which were then connected to the SIFT‐MS instrument. For real‐time analysis, breath was sampled directly into the instrument. In both cases the analytical method included a total of 155 product ions, and 14 selected volatiles were quantified. The agreement between the methods was assessed using Pearson correlation coefficients and Bland–Altman plots. Results: Overall, correlations between real‐time and off‐line analysis were moderate to very strong ( r = 0.43–0.92) depending on the volatile of interest, except for 2,3‐butanedione and styrene. The difference between real‐time and off‐line measured breath concentrations (average bias) ranged between −14.57 and 20.48 ppbv. For acetone and isoprene, it was 251.53 and 31.9 ppbv, respectively. Conclusions: Real‐time SIFT‐MS and off‐line TD SIFT‐MS for quantification of selected breath volatiles did not show optimal agreement. Analyzing a multitude of analytes in breath via direct exhalation into a SIFT‐MS instrument for real‐time analysis is challenging. On the other hand, off‐line analysis using a breath collection device also has its issues such as possible sample losses due to selective absorption depending on the sorbent used or during desorption and transfer to the instrument. Despite these drawbacks, both methods were moderately well correlated.
- 30 October 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (4) , e8994
Real‐time versus thermal desorption selected ion flow tube mass spectrometry for quantification of breath volatiles
Rationale: Selected ion flow tube mass spectrometry (SIFT‐MS) is versatile, rapidly provides result output and determines a wide range of volatiles, making it suitable for biomedical applications. When direct sampling into the SIFT‐MS instrument is impractical, combining thermal desorption (TD) and SIFT‐MS might offer a solution as it allows sample storage on sorbent tubes for later analysis. This work compares off‐line TD SIFT‐MS and real‐time SIFT‐MS for the quantification of selected breath volatiles. Methods: Ten healthy non‐smoking individuals provided 60 breath samples per method. For off‐line analysis, breath was collected onto sorbent tubes via a breath sampler provided with filtered inspiratory air. After TD, samples were re‐collected in Tedlar bags which were then connected to the SIFT‐MS instrument. For real‐time analysis, breath was sampled directly into the instrument. In both cases the analytical method included a total of 155 product ions, and 14 selected volatiles were quantified. The agreement between the methods was assessed using Pearson correlation coefficients and Bland–Altman plots. Results: Overall, correlations between real‐time and off‐line analysis were moderate to very strong ( r = 0.43–0.92) depending on the volatile of interest, except for 2,3‐butanedione and styrene. The difference between real‐time and off‐line measured breath concentrations (average bias) ranged between −14.57 and 20.48 ppbv. For acetone and isoprene, it was 251.53 and 31.9 ppbv, respectively. Conclusions: Real‐time SIFT‐MS and off‐line TD SIFT‐MS for quantification of selected breath volatiles did not show optimal agreement. Analyzing a multitude of analytes in breath via direct exhalation into a SIFT‐MS instrument for real‐time analysis is challenging. On the other hand, off‐line analysis using a breath collection device also has its issues such as possible sample losses due to selective absorption depending on the sorbent used or during desorption and transfer to the instrument. Despite these drawbacks, both methods were moderately well correlated.
- 30 June 2020
- Published by IOP Publishing in Journal of Breath Research
- Vol. 14 (3) , 036006
Real-time selected ion flow tube mass spectrometry to assess short- and long-term variability in oral and nasal breath
Breath-based non-invasive diagnostics have the potential to provide valuable information about a person’s health status. However, they are not yet widely used in clinical practice due to multiple factors causing variability and the lack of standardized procedures. This study focuses on the comparison of oral and nasal breathing, and on the variability of volatile metabolites over the short and long term. Selected ion flow tube mass spectrometry (SIFT-MS) was used for online analysis of selected volatile metabolites in oral and nasal breath of 10 healthy individuals five times in one day (short-term) and six times spread over three weeks (long-term), resulting in nearly 100 breath samplings. Intra-class correlation coefficients (ICCs) were used to assess short- and long-term biological variability. Additionally, the composition of ambient air was analyzed at different samplings. The selected volatiles common in exhaled breath were propanol, 2,3-butanedione, acetaldehyde, acetone, ammonia, dimethyl sulfide, isoprene, pentane, and propanal. Additionally, environmental compounds benzene and styrene were analyzed as well. Volatile metabolite concentrations in ambient air were not correlated with those in exhaled breath and were significantly lower than in breath samples. All volatiles showed significant correlation between oral and nasal breath. Five were significantly higher in oral breath compared to nasal breath, while for acetone, propanal, dimethyl sulfide, and ammonia, concentrations were similar in both matrices. Variability depended on the volatile metabolite. Most physiologically relevant volatiles (acetone, isoprene, propanol, acetaldehyde) showed good to very good biological reproducibility (ICC > 0.61) mainly in oral breath and over a short-term period of one day. Both breathing routes showed relatively similar patterns; however, bigger differences were expected. Therefore, since sampling from the mouth is practically more easy, the latter might be preferred.
- 30 June 2020
- Published by IOP Publishing in Journal of Breath Research
- Vol. 14 (3) , 036006
Real-time selected ion flow tube mass spectrometry to assess short- and long-term variability in oral and nasal breath
Breath-based non-invasive diagnostics have the potential to provide valuable information about a person’s health status. However, they are not yet widely used in clinical practice due to multiple factors causing variability and the lack of standardized procedures. This study focuses on the comparison of oral and nasal breathing, and on the variability of volatile metabolites over the short and long term. Selected ion flow tube mass spectrometry (SIFT-MS) was used for online analysis of selected volatile metabolites in oral and nasal breath of 10 healthy individuals five times in one day (short-term) and six times spread over three weeks (long-term), resulting in nearly 100 breath samplings. Intra-class correlation coefficients (ICCs) were used to assess short- and long-term biological variability. Additionally, the composition of ambient air was analyzed at different samplings. The selected volatiles common in exhaled breath were propanol, 2,3-butanedione, acetaldehyde, acetone, ammonia, dimethyl sulfide, isoprene, pentane, and propanal. Additionally, environmental compounds benzene and styrene were analyzed as well. Volatile metabolite concentrations in ambient air were not correlated with those in exhaled breath and were significantly lower than in breath samples. All volatiles showed significant correlation between oral and nasal breath. Five were significantly higher in oral breath compared to nasal breath, while for acetone, propanal, dimethyl sulfide, and ammonia, concentrations were similar in both matrices. Variability depended on the volatile metabolite. Most physiologically relevant volatiles (acetone, isoprene, propanol, acetaldehyde) showed good to very good biological reproducibility (ICC > 0.61) mainly in oral breath and over a short-term period of one day. Both breathing routes showed relatively similar patterns; however, bigger differences were expected. Therefore, since sampling from the mouth is practically more easy, the latter might be preferred.
- Open Access
- 10 June 2020
- Published by Wiley
Diagnostic characterization of respiratory allergies by means of a multiplex immunoassay.
Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.
- 10 June 2020
- Published by Wiley
Open AccessDiagnostic characterization of respiratory allergies by means of a multiplex immunoassay.
Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.
- Open Access
- 8 May 2020
- Published by Wiley
Diagnostic characterization of respiratory allergies by means of a multiplex immunoassay.
Background: Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. Methods: The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Results: Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). Conclusion: The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.
- 8 May 2020
- Published by Wiley
Open AccessDiagnostic characterization of respiratory allergies by means of a multiplex immunoassay.
Background: Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. Methods: The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Results: Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). Conclusion: The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.