Andrei Iantsen
Research Subjects
Andrei Iantsen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Dimitris Visvikis
LaTIM, INSERM, UMR 1101, University Brest, Brest, France
3 shared publicationsMathieu Hatt
LaTIM, INSERM, UMR 1101, University Brest, Brest, France
3 shared publicationsVincent Jaouen
LaTIM, INSERM, UMR 1101, University Brest, Brest, France
3 shared publicationsAugustin Mervoyer
Department of Radiation Oncology, Institut de Cancérologie de l’Ouest (ICO), Nantes, France
1 shared publicationCaroline Reinhold
Department of Radiology, McGill University Health Centre (MUHC), Montreal, Canada
1 shared publicationCaroline Rousseau
Nuclear Medicine Department, Institut de Cancérologie de l’Ouest (ICO), Nantes, France
1 shared publication
Latest Publications
- 6 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Automated tumor segmentation in multimodal PET / CT / MR imaging
Segmentation automatique de tumeurs en imagerie multimodale TEP / TDM / IRM: Les systèmes de reconnaissance visuelle fondés sur des réseaux de neurones convolutionnels (RNC) ont le potentiel d’améliorer le processus de prise en charge des patients. La fiabilité et la précision de solutions utilisant des RNC sont le sujet de cette thèse, dans le contexte de la segmentation automatisée de tumeurs. Quatre tâches dans différentes modalités d’images ont été considérées. (1) Un modèle pour la segmentation de tumeurs du col de l’utérus en imagerie TEP a été entraîné sur des références fiables dans un contexte multicentrique, obtenant des performances robustes en s’appuyant sur de simples techniques d’augmentation de données. (2) Un module de norme ≪squeeze-and-excitation≫ a été introduit dans le contexte de la segmentation de tumeurs tête et cou sur des images TEP/TDM multicentriques, obtenant de bons résultats sans standardisation spécifique. (3) La même approche, avec des modifications mineures, a été employée dans le contexte de tumeurs cérébrales dans des séquences IRM. Les deux méthodes ont obtenu des résultats compétitifs dans des compétitions en 2020, sans nécessité d’ajustement spécifique. (4) Un modèle a été construit pour la détection et la segmentation de lésions de lymphomes et de sarcoïdoses en imagerie TEP/TDM, avec de bons résultats sur les pathologies considérées, confirmant ainsi le potentiel des RNCs dans un contexte de plusieurs pathologies différentes. Les résultats présentés dans cette thèse représentent une avancée vers l’intégration de ces méthodes en routine clinique.
- 6 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Automated tumor segmentation in multimodal PET / CT / MR imaging
Segmentation automatique de tumeurs en imagerie multimodale TEP / TDM / IRM: Les systèmes de reconnaissance visuelle fondés sur des réseaux de neurones convolutionnels (RNC) ont le potentiel d’améliorer le processus de prise en charge des patients. La fiabilité et la précision de solutions utilisant des RNC sont le sujet de cette thèse, dans le contexte de la segmentation automatisée de tumeurs. Quatre tâches dans différentes modalités d’images ont été considérées. (1) Un modèle pour la segmentation de tumeurs du col de l’utérus en imagerie TEP a été entraîné sur des références fiables dans un contexte multicentrique, obtenant des performances robustes en s’appuyant sur de simples techniques d’augmentation de données. (2) Un module de norme ≪squeeze-and-excitation≫ a été introduit dans le contexte de la segmentation de tumeurs tête et cou sur des images TEP/TDM multicentriques, obtenant de bons résultats sans standardisation spécifique. (3) La même approche, avec des modifications mineures, a été employée dans le contexte de tumeurs cérébrales dans des séquences IRM. Les deux méthodes ont obtenu des résultats compétitifs dans des compétitions en 2020, sans nécessité d’ajustement spécifique. (4) Un modèle a été construit pour la détection et la segmentation de lésions de lymphomes et de sarcoïdoses en imagerie TEP/TDM, avec de bons résultats sur les pathologies considérées, confirmant ainsi le potentiel des RNCs dans un contexte de plusieurs pathologies différentes. Les résultats présentés dans cette thèse représentent une avancée vers l’intégration de ces méthodes en routine clinique.
- Open Access
- 3 March 2025
- Published by Springer Nature
- Vol. 15273, 230-240
Improving the U-Net Configuration for Automated Delineation of Head and Neck Cancer on MRI
Tumor volume segmentation on MRI is a challenging and time-consuming process that is performed manually in typical clinical settings. This work presents an approach to automated delineation of head and neck tumors on MRI scans, developed in the context of the MICCAI Head and Neck Tumor Segmentation for MR-Guided Applications (HNTS-MRG) 2024 Challenge. Rather than designing a new, task-specific convolutional neural network, the focus of this research was to propose improvements to the configuration commonly used in medical segmentation tasks, relying solely on the traditional U-Net architecture. The empirical results presented in this article suggest the superiority of patch-wise normalization used for both training and sliding window inference. They also indicate that the performance of segmentation models can be enhanced by applying a scheduled data augmentation policy during training. Finally, it is shown that a small improvement in quality can be achieved by using Gaussian weighting to combine predictions for individual patches during sliding window inference. The model with the best configuration obtained an aggregated Dice Similarity Coefficient (DSCagg) of 0.749 in Task 1 and 0.710 in Task 2 on five cross-validation folds. The ensemble of five models (one best model per validation fold) showed consistent results on a private test set of 50 patients with an DSCagg of 0.752 in Task 1 and 0.718 in Task 2 (team name: ). The source code and model weights are freely available at www.github.com/iantsen/hntsmrg.
- 3 March 2025
- Published by Springer Nature
- Vol. 15273, 230-240
Open AccessImproving the U-Net Configuration for Automated Delineation of Head and Neck Cancer on MRI
Tumor volume segmentation on MRI is a challenging and time-consuming process that is performed manually in typical clinical settings. This work presents an approach to automated delineation of head and neck tumors on MRI scans, developed in the context of the MICCAI Head and Neck Tumor Segmentation for MR-Guided Applications (HNTS-MRG) 2024 Challenge. Rather than designing a new, task-specific convolutional neural network, the focus of this research was to propose improvements to the configuration commonly used in medical segmentation tasks, relying solely on the traditional U-Net architecture. The empirical results presented in this article suggest the superiority of patch-wise normalization used for both training and sliding window inference. They also indicate that the performance of segmentation models can be enhanced by applying a scheduled data augmentation policy during training. Finally, it is shown that a small improvement in quality can be achieved by using Gaussian weighting to combine predictions for individual patches during sliding window inference. The model with the best configuration obtained an aggregated Dice Similarity Coefficient (DSCagg) of 0.749 in Task 1 and 0.710 in Task 2 on five cross-validation folds. The ensemble of five models (one best model per validation fold) showed consistent results on a private test set of 50 patients with an DSCagg of 0.752 in Task 1 and 0.718 in Task 2 (team name: ). The source code and model weights are freely available at www.github.com/iantsen/hntsmrg.
- Open Access
Improving the U-Net Configuration for Automated Delineation of Head and Neck Cancer on MRI
Tumor volume segmentation on MRI is a challenging and time-consuming process that is performed manually in typical clinical settings. This work presents an approach to automated delineation of head and neck tumors on MRI scans, developed in the context of the MICCAI Head and Neck Tumor Segmentation for MR-Guided Applications (HNTS-MRG) 2024 Challenge. Rather than designing a new, task-specific convolutional neural network, the focus of this research was to propose improvements to the configuration commonly used in medical segmentation tasks, relying solely on the traditional U-Net architecture. The empirical results presented in this article suggest the superiority of patch-wise normalization used for both training and sliding window inference. They also indicate that the performance of segmentation models can be enhanced by applying a scheduled data augmentation policy during training. Finally, it is shown that a small improvement in quality can be achieved by using Gaussian weighting to combine predictions for individual patches during sliding window inference. The model with the best configuration obtained an aggregated Dice Similarity Coefficient (DSCagg) of 0.749 in Task 1 and 0.710 in Task 2 on five cross-validation folds. The ensemble of five models (one best model per validation fold) showed consistent results on a private test set of 50 patients with an DSCagg of 0.752 in Task 1 and 0.718 in Task 2 (team name: andrei.iantsen). The source code and model weights are freely available at www.github.com/iantsen/hntsmrg.
Open AccessImproving the U-Net Configuration for Automated Delineation of Head and Neck Cancer on MRI
Tumor volume segmentation on MRI is a challenging and time-consuming process that is performed manually in typical clinical settings. This work presents an approach to automated delineation of head and neck tumors on MRI scans, developed in the context of the MICCAI Head and Neck Tumor Segmentation for MR-Guided Applications (HNTS-MRG) 2024 Challenge. Rather than designing a new, task-specific convolutional neural network, the focus of this research was to propose improvements to the configuration commonly used in medical segmentation tasks, relying solely on the traditional U-Net architecture. The empirical results presented in this article suggest the superiority of patch-wise normalization used for both training and sliding window inference. They also indicate that the performance of segmentation models can be enhanced by applying a scheduled data augmentation policy during training. Finally, it is shown that a small improvement in quality can be achieved by using Gaussian weighting to combine predictions for individual patches during sliding window inference. The model with the best configuration obtained an aggregated Dice Similarity Coefficient (DSCagg) of 0.749 in Task 1 and 0.710 in Task 2 on five cross-validation folds. The ensemble of five models (one best model per validation fold) showed consistent results on a private test set of 50 patients with an DSCagg of 0.752 in Task 1 and 0.718 in Task 2 (team name: andrei.iantsen). The source code and model weights are freely available at www.github.com/iantsen/hntsmrg.
- Open Access
- 27 March 2021
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (11) , 3444-3456
Convolutional neural networks for PET functional volume fully automatic segmentation: development and validation in a multi-center setting
Purpose: In this work, we addressed fully automatic determination of tumor functional uptake from positron emission tomography (PET) images without relying on other image modalities or additional prior constraints, in the context of multicenter images with heterogeneous characteristics.Methods: In cervical cancer, an additional challenge is the location of the tumor uptake near or even stuck to the bladder. PET datasets of 232 patients from five institutions were exploited. To avoid unreliable manual delineations, the ground truth was generated with a semi-automated approach: a volume containing the tumor and excluding the bladder was first manually determined, then a well-validated, semi-automated approach relying on the Fuzzy locally Adaptive Bayesian (FLAB) algorithm was applied to generate the ground truth. Our model built on the U-Net architecture incorporates residual blocks with concurrent spatial squeeze and excitation modules, as well as learnable non-linear downsampling and upsampling blocks. Experiments relied on cross-validation (four institutions for training and validation, and the fifth for testing).Results: The model achieved good Dice similarity coefficient (DSC) with little variability across institutions (0.80 ± 0.03), with higher recall (0.90 ± 0.05) than precision (0.75 ± 0.05) and improved results over the standard U-Net (DSC 0.77 ± 0.05, recall 0.87 ± 0.02, precision 0.74 ± 0.08). Both vastly outperformed a fixed threshold at 40% of SUVmax (DSC 0.33 ± 0.15, recall 0.52 ± 0.17, precision 0.30 ± 0.16). In all cases, the model could determine the tumor uptake without including the bladder. Neither shape priors nor anatomical information was required to achieve efficient training.Conclusion: The proposed method could facilitate the deployment of a fully automated radiomics pipeline in such a challenging multicenter context.
- 27 March 2021
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (11) , 3444-3456
Open AccessConvolutional neural networks for PET functional volume fully automatic segmentation: development and validation in a multi-center setting
Purpose: In this work, we addressed fully automatic determination of tumor functional uptake from positron emission tomography (PET) images without relying on other image modalities or additional prior constraints, in the context of multicenter images with heterogeneous characteristics.Methods: In cervical cancer, an additional challenge is the location of the tumor uptake near or even stuck to the bladder. PET datasets of 232 patients from five institutions were exploited. To avoid unreliable manual delineations, the ground truth was generated with a semi-automated approach: a volume containing the tumor and excluding the bladder was first manually determined, then a well-validated, semi-automated approach relying on the Fuzzy locally Adaptive Bayesian (FLAB) algorithm was applied to generate the ground truth. Our model built on the U-Net architecture incorporates residual blocks with concurrent spatial squeeze and excitation modules, as well as learnable non-linear downsampling and upsampling blocks. Experiments relied on cross-validation (four institutions for training and validation, and the fifth for testing).Results: The model achieved good Dice similarity coefficient (DSC) with little variability across institutions (0.80 ± 0.03), with higher recall (0.90 ± 0.05) than precision (0.75 ± 0.05) and improved results over the standard U-Net (DSC 0.77 ± 0.05, recall 0.87 ± 0.02, precision 0.74 ± 0.08). Both vastly outperformed a fixed threshold at 40% of SUVmax (DSC 0.33 ± 0.15, recall 0.52 ± 0.17, precision 0.30 ± 0.16). In all cases, the model could determine the tumor uptake without including the bladder. Neither shape priors nor anatomical information was required to achieve efficient training.Conclusion: The proposed method could facilitate the deployment of a fully automated radiomics pipeline in such a challenging multicenter context.
- 26 March 2021
- Published by Springer Nature
- p. 366-373
Squeeze-and-Excitation Normalization for Brain Tumor Segmentation
- 26 March 2021
- Published by Springer Nature
- p. 366-373
Squeeze-and-Excitation Normalization for Brain Tumor Segmentation
- 13 January 2021
- Published by Springer Nature
- p. 37-43
Squeeze-and-Excitation Normalization for Automated Delineation of Head and Neck Primary Tumors in Combined PET and CT Images
- 13 January 2021
- Published by Springer Nature
- p. 37-43
Squeeze-and-Excitation Normalization for Automated Delineation of Head and Neck Primary Tumors in Combined PET and CT Images
- 19 May 2020
- Published by Springer Nature
- p. 296-302
Encoder-Decoder Network for Brain Tumor Segmentation on Multi-sequence MRI
- 19 May 2020
- Published by Springer Nature
- p. 296-302
Encoder-Decoder Network for Brain Tumor Segmentation on Multi-sequence MRI