Anna L. Roethe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna L. Roethe has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Peter Vajkoczy
Charite Univ Med Berlin, Dept Neurosurg, Berlin, Germany
3 shared publicationsThomas Picht
Charite Univ Med Berlin, Dept Neurosurg, Berlin, Germany
3 shared publicationsJudith Rösler
Charite Univ Med Berlin, Dept Neurosurg, Berlin, Germany
2 shared publicationsMartin Misch
Department of Neurosurgery, Charité-Universitätsmedizin Berlin, Berlin, Germany
2 shared publications- Thomas Picht
Department of Neurosurgery, Charité – Universitätsmedizin Berlin, Berlin, Germany
2 shared publications Adrien Lavalley
Charite Univ Med Berlin, Dept Neurosurg, Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 9 November 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 20, 100573
Non-cadaveric spine surgery simulator training in neurosurgical residency
- 9 November 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 20, 100573
Open AccessNon-cadaveric spine surgery simulator training in neurosurgical residency
- Open Access
- 5 February 2024
- Published by Elsevier in World Neurosurgery
- Vol. 185, 60-70
Tailored Concept for Accurate Neuroendoscopy: A Comparative Retrospective Single-Center Study on Image-Guided Neuroendoscopic Procedures
- 5 February 2024
- Published by Elsevier in World Neurosurgery
- Vol. 185, 60-70
Open AccessTailored Concept for Accurate Neuroendoscopy: A Comparative Retrospective Single-Center Study on Image-Guided Neuroendoscopic Procedures
- Open Access
- 28 February 2023
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (4) , 1087-1098
Personalized surgical informed consent with stereoscopic visualization in neurosurgery—real benefit for the patient or unnecessary gimmick?
Background: Informed consent of the patient prior to surgical procedures is obligatory. A good and informative communication improves patients’ understanding and confidence, thus may strengthen the patient-doctor relationship. The aim of our study was to investigate the usefulness of additional stereoscopic visualization of patient-specific imaging during informed consent conversation. Methods: Patients scheduled for a brain tumor surgery were screened for this study prospectively. The primary exclusion criteria were cognitive or visual impairments. The participants were randomized into two groups. The first group underwent a conventional surgical informed consent performed by a neurosurgeon including a demonstration of the individual MRI on a 2D computer screen. The second group received an additional stereoscopic visualization of the same imaging to explain the pathology more in-depth. The patients were then asked to fill in a questionnaire after each part. This questionnaire was designed to assess the potential information gained from the patients with details on the anatomical location of the tumor as well as the surgical procedure and possible complications. Patients’ subjective impression about the informed consent was assessed using a 5-point Likert scale. Results: A total of 27 patients were included in this study. After additional stereoscopic visualization, no significant increase in patient understanding was found for either objective criteria or subjective assessment. Participants’ anxiety was not increased by stereoscopic visualization. Overall, patients perceived stereoscopic imaging as helpful from a subjective perspective. Confidence in the department was high in both groups. Conclusion: Stereoscopic visualization of MRI images within informed consent conversation did not improve the objective understanding of the patients in our series. Although no objective anatomical knowledge gain was noted in this series, patients felt that the addition of stereoscopic visualization improved their overall understanding. It therefore potentially increases patient confidence in treatment decisions.
- 28 February 2023
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (4) , 1087-1098
Open AccessPersonalized surgical informed consent with stereoscopic visualization in neurosurgery—real benefit for the patient or unnecessary gimmick?
Background: Informed consent of the patient prior to surgical procedures is obligatory. A good and informative communication improves patients’ understanding and confidence, thus may strengthen the patient-doctor relationship. The aim of our study was to investigate the usefulness of additional stereoscopic visualization of patient-specific imaging during informed consent conversation. Methods: Patients scheduled for a brain tumor surgery were screened for this study prospectively. The primary exclusion criteria were cognitive or visual impairments. The participants were randomized into two groups. The first group underwent a conventional surgical informed consent performed by a neurosurgeon including a demonstration of the individual MRI on a 2D computer screen. The second group received an additional stereoscopic visualization of the same imaging to explain the pathology more in-depth. The patients were then asked to fill in a questionnaire after each part. This questionnaire was designed to assess the potential information gained from the patients with details on the anatomical location of the tumor as well as the surgical procedure and possible complications. Patients’ subjective impression about the informed consent was assessed using a 5-point Likert scale. Results: A total of 27 patients were included in this study. After additional stereoscopic visualization, no significant increase in patient understanding was found for either objective criteria or subjective assessment. Participants’ anxiety was not increased by stereoscopic visualization. Overall, patients perceived stereoscopic imaging as helpful from a subjective perspective. Confidence in the department was high in both groups. Conclusion: Stereoscopic visualization of MRI images within informed consent conversation did not improve the objective understanding of the patients in our series. Although no objective anatomical knowledge gain was noted in this series, patients felt that the addition of stereoscopic visualization improved their overall understanding. It therefore potentially increases patient confidence in treatment decisions.
- Open Access
- 13 December 2021
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 164 (1) , 3-14
Augmented reality visualization in brain lesions: a prospective randomized controlled evaluation of its potential and current limitations in navigated microneurosurgery
Background: Augmented reality (AR) has the potential to support complex neurosurgical interventions by including visual information seamlessly. This study examines intraoperative visualization parameters and clinical impact of AR in brain tumor surgery.Methods: Fifty-five intracranial lesions, operated either with AR-navigated microscope (n = 39) or conventional neuronavigation (n = 16) after randomization, have been included prospectively. Surgical resection time, duration/type/mode of AR, displayed objects (n, type), pointer-based navigation checks (n), usability of control, quality indicators, and overall surgical usefulness of AR have been assessed.Results: AR display has been used in 44.4% of resection time. Predominant AR type was navigation view (75.7%), followed by target volumes (20.1%). Predominant AR mode was picture-in-picture (PiP) (72.5%), followed by 23.3% overlay display. In 43.6% of cases, vision of important anatomical structures has been partially or entirely blocked by AR information. A total of 7.7% of cases used MRI navigation only, 30.8% used one, 23.1% used two, and 38.5% used three or more object segmentations in AR navigation. A total of 66.7% of surgeons found AR visualization helpful in the individual surgical case. AR depth information and accuracy have been rated acceptable (median 3.0 vs. median 5.0 in conventional neuronavigation). The mean utilization of the navigation pointer was 2.6 × /resection hour (AR) vs. 9.7 × /resection hour (neuronavigation); navigation effort was significantly reduced in AR (P < 0.001).Conclusions: The main benefit of HUD-based AR visualization in brain tumor surgery is the integrated continuous display allowing for pointer-less navigation. Navigation view (PiP) provides the highest usability while blocking the operative field less frequently. Visualization quality will benefit from improvements in registration accuracy and depth impression.German clinical trials registration number.: DRKS00016955.
- 13 December 2021
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 164 (1) , 3-14
Open AccessAugmented reality visualization in brain lesions: a prospective randomized controlled evaluation of its potential and current limitations in navigated microneurosurgery
Background: Augmented reality (AR) has the potential to support complex neurosurgical interventions by including visual information seamlessly. This study examines intraoperative visualization parameters and clinical impact of AR in brain tumor surgery.Methods: Fifty-five intracranial lesions, operated either with AR-navigated microscope (n = 39) or conventional neuronavigation (n = 16) after randomization, have been included prospectively. Surgical resection time, duration/type/mode of AR, displayed objects (n, type), pointer-based navigation checks (n), usability of control, quality indicators, and overall surgical usefulness of AR have been assessed.Results: AR display has been used in 44.4% of resection time. Predominant AR type was navigation view (75.7%), followed by target volumes (20.1%). Predominant AR mode was picture-in-picture (PiP) (72.5%), followed by 23.3% overlay display. In 43.6% of cases, vision of important anatomical structures has been partially or entirely blocked by AR information. A total of 7.7% of cases used MRI navigation only, 30.8% used one, 23.1% used two, and 38.5% used three or more object segmentations in AR navigation. A total of 66.7% of surgeons found AR visualization helpful in the individual surgical case. AR depth information and accuracy have been rated acceptable (median 3.0 vs. median 5.0 in conventional neuronavigation). The mean utilization of the navigation pointer was 2.6 × /resection hour (AR) vs. 9.7 × /resection hour (neuronavigation); navigation effort was significantly reduced in AR (P < 0.001).Conclusions: The main benefit of HUD-based AR visualization in brain tumor surgery is the integrated continuous display allowing for pointer-less navigation. Navigation view (PiP) provides the highest usability while blocking the operative field less frequently. Visualization quality will benefit from improvements in registration accuracy and depth impression.German clinical trials registration number.: DRKS00016955.
- Open Access
- 4 May 2021
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 163 (8) , 2095-2096
Redefining standards—response to: introductions of technological innovations in neurosurgery
- 4 May 2021
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 163 (8) , 2095-2096
Open AccessRedefining standards—response to: introductions of technological innovations in neurosurgery
- Open Access
- 19 May 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (12) , 2949-2961
Monitor-based exoscopic 3D4k neurosurgical interventions: a two-phase prospective-randomized clinical evaluation of a novel hybrid device
Background: Promoting a disruptive innovation in microsurgery, exoscopes promise alleviation of physical strain and improved image quality through digital visualization during microneurosurgical interventions. This study investigates the impact of a novel 3D4k hybrid exoscope (i.e., combining digital and optical visualization) on surgical performance and team workflow in preclinical and clinical neurosurgical settings. Methods: A pre-clinical workshop setting has been developed to assess usability and implementability through skill-based scenarios (neurosurgical participants n = 12). An intraoperative exploration in head and spine surgery (n = 9) and a randomized clinical study comparing ocular and monitor mode in supratentorial brain tumor cases (n = 20) followed within 12 months. Setup, procedure, case characteristics, surgical performance, and user experience have been analyzed for both ocular group (OG) and monitor group (MG). Results: Brain tumor cases using frontal, frontoparietal, or temporal approaches have been identified as favorable use cases for introducing exoscopic neurosurgery. Mean monitor distance and angle were 180 cm and 10°. Surgical ergonomics when sitting improved significantly in MG compared with OG (P = .03). Hand-eye coordination required familiarization in MG. Preclinical data showed a positive correlation between lateral camera inclination and impact on hand-eye coordination (rs = 0.756, P = .01). There was no significant added surgical time in MG. Image quality in current generation 3D4k monitors has been rated inferior to optic visualization yet awaits updates. Conclusions: The hybrid exoscopic device can be integrated into established neurosurgical workflows. Currently, exoscopic interventions seem most suited for cranial tumor surgery in lesions that are not deep-seated. Ergonomics improve in monitor mode compared to conventional microsurgery.
- 19 May 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (12) , 2949-2961
Open AccessMonitor-based exoscopic 3D4k neurosurgical interventions: a two-phase prospective-randomized clinical evaluation of a novel hybrid device
Background: Promoting a disruptive innovation in microsurgery, exoscopes promise alleviation of physical strain and improved image quality through digital visualization during microneurosurgical interventions. This study investigates the impact of a novel 3D4k hybrid exoscope (i.e., combining digital and optical visualization) on surgical performance and team workflow in preclinical and clinical neurosurgical settings. Methods: A pre-clinical workshop setting has been developed to assess usability and implementability through skill-based scenarios (neurosurgical participants n = 12). An intraoperative exploration in head and spine surgery (n = 9) and a randomized clinical study comparing ocular and monitor mode in supratentorial brain tumor cases (n = 20) followed within 12 months. Setup, procedure, case characteristics, surgical performance, and user experience have been analyzed for both ocular group (OG) and monitor group (MG). Results: Brain tumor cases using frontal, frontoparietal, or temporal approaches have been identified as favorable use cases for introducing exoscopic neurosurgery. Mean monitor distance and angle were 180 cm and 10°. Surgical ergonomics when sitting improved significantly in MG compared with OG (P = .03). Hand-eye coordination required familiarization in MG. Preclinical data showed a positive correlation between lateral camera inclination and impact on hand-eye coordination (rs = 0.756, P = .01). There was no significant added surgical time in MG. Image quality in current generation 3D4k monitors has been rated inferior to optic visualization yet awaits updates. Conclusions: The hybrid exoscopic device can be integrated into established neurosurgical workflows. Currently, exoscopic interventions seem most suited for cranial tumor surgery in lesions that are not deep-seated. Ergonomics improve in monitor mode compared to conventional microsurgery.