Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sang Hyun Ko has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Which is more important for achieving superior stability in a massive rotator cuff tear? The spacer effect (static) vs. concavity compression (dynamic): a biomechanical cadaveric study

    by Yoon Sang Jeon, Sang Hyun Ko, Yoon Cheol Nam, Gi Cheol Bae, Dong Jin Ryu, Yeop Na, Dong Seok Kang, Sungwook Jung, Aaron Hui, Michelle H. McGarry, et al.

  • Open Access

    Do Magnets Have the Potential to Serve as a Stabilizer for the Shoulder Joint in Massive Rotator Cuff Tears?: A Biomechanical Cadaveric Study

    by Yoon Sang Jeon, Sang Hyun Ko, Yun Moon Jeon, Dong Jin Ryu, Jeong Seok Kim, Hyun Soon Park, Min-Shik Chung, Daniel Kwak, Michelle H. McGarry, Thay Q. Lee

    Jeon YS, et al. Clin Orthop Surg. 2023 Aug;15(4):616-626. https://doi.org/10.4055/cios22397


  • Open Access

    The Inlay Technique with Cortico-Cancellous Olecranon Bone Graft Used for Revision of Failed Distal Interphalangeal Joint Arthrodesis

    by Sang-Hyun Ko, Joo-Won Park, Tong-Joo Lee

    Background and Objectives: Although distal interphalangeal (DIP) arthrodesis is an effective surgical method for end-stage osteoarthritis of the phalangeal joint, the nonunion rate of DIP arthrodesis has been reported to range from 15% to 20%. To this end, we devised an inlay technique with a cortico-cancellous olecranon bone graft for failed DIP arthrodesis. This study aimed to introduce the inlay bone grafting technique for failed arthrodesis of the DIP joint and demonstrate its advantages. Materials and Methods: We reviewed consecutive 19 digits (15 patients) who had undergone DIP revision arthrodesis using the technique at our institution between January 2010 and December 2020. The observed outcome measures were the bone union rate, and related complications. Bone union was evaluated using follow-up radiography. The quick Disabilities of the Arm, Shoulder and Hand (DASH), visual analog scale (VAS) for pain, and VAS for satisfaction assessed patient function and perceived clinical outcomes. Results: No major complications were observed at the recipient site. The average VAS for pain and satisfaction and DASH score improved from preoperatively to 6 months after surgery (both, p = 0.001). Conclusions: The inlay technique with cortico-cancellous olecranon bone grafts showed excellent bone union rates and functional scores with nonunion of the DIP joint. This technique may be an adequate surgical option for patients with confirmed nonunion of the DIP joint and persistent symptoms.


  • Open Access

    Optimal Release Timing of Drain Clamping to Reduce Postoperative Bleeding after Total Knee Arthroplasty with Intraarticular Injection of Tranexamic Acid

    by Myung-Ku Kim, Sang-Hyun Ko, Yoon-Cheol Nam, Yoon-Sang Jeon, Dae-Gyu Kwon, Dong-Jin Ryu

    Background and Objectives: Intraarticular injection of tranexamic acid (IA-TXA) plus drain-clamping is a preferred method of reducing bleeding after total knee arthroplasty (TKA). However, no consensus has been reached regarding the timing of the clamping. The purpose of this study was to determine the optimum duration of drain-clamping after TKA with IA-TXA. Materials and Methods: We retrospectively reviewed 151 patients that underwent unilateral TKA with IA-TXA plus drain-clamping for 30 min, 2 h, or 3 h. The total drained volume was reviewed as the primary outcome, and hematocrit (Hct) reductions, estimated blood loss (EBL), transfusion rates, and wound complications were reviewed as secondary outcomes. Results: The mean total drained volume, Hct reduction, and EBL were significantly less in the 3 h group than in the 30 min group. Between the 2 h and 3 h groups, there was no statistical difference in the mean total drained volume, Hct reduction, or EBL. The proportion of patients who drained lesser than 300 mL was high in the 3 h group. No significant intergroup difference was observed for transfusion volume, transfusion rate, and wound related complications. Conclusions: In comparison of the IA-TXA plus drain-clamping after TKA, there was no difference in EBL between the 2 h group and the 3 h group, but the amount of drainage volume was small in the 3 h group.


  • Open Access

    Effectiveness of continuous femoral nerve block for pain relief after total knee arthroplasty: comparison with epidural patient-controlled analgesia and periarticular injection

    by Myung Ku Kim, Sang Hyun Ko, Yoon Joong Hwang, Dae Gyu Kwon, Yoon Sang Jeon, Dong Jin Ryu

    Objective: To compare the clinical outcomes among three analgesic techniques, continuous femoral nerve block (CFNB), epidural patient-controlled analgesia (EPCA) and periarticular injection (PAI), in patients undergoing total knee arthroplasty (TKA). Methods: This retrospective case–control study enrolled patients that underwent TKA. Visual analogue scale (VAS) pain scores, sleep disturbance, additional opioid consumption and incidence of opioid-related side-effects were assessed. Results: A total of 120 patients were categorized into three groups: EPCA (group A, n = 40), PAI (group B, n = 40) and CFNB (group C, n = 40). Group C had significantly lower VAS pain scores than groups A and B at 8, 12 and 24 h after TKA. There were no significant differences in VAS pain scores among the three groups from 48 h after TKA. Sleep quality on the first day after surgery was significantly better in group C than in groups A and B. Additional opioid consumption was significantly lower in the group C than in the groups A and B. Group C showed a lower rate of opioid-related side-effects than groups A and B. Conclusion: CFNB was a more effective additional analgesic technique than EPCA or PAI for acute postoperative pain control within 24 h of TKA.


  • Open Access

    Steroid injection using tendon excursion for trigger finger: introduction to injection methods and analysis of treatment results

    by Sang Hyun Ko, Dong Eun Kim, Tong Joo Lee

    Purpose: Local corticosteroid injections are routinely used as first-line treatment for trigger finger. However, accurate delivery of steroids into the tendon sheath is important for the effectiveness of the treatment and the prevention of complications. This study aimed to introduce our steroid injection technique for trigger finger, which uses tendon excursion of the flexor tendon, and evaluate the clinical outcomes in patients who were treated with this technique.Methods: A total of 171 patients with trigger finger who were treated with steroid injections were retrospectively reviewed. The efficacy of injection and complications were investigated. The evaluation of the efficacy was classified into “good,” “fair,” and “poor.” The results were analyzed according to the type of finger and the Quinnell grading system.Results: The total efficacy was 83.6% (good/fair, 143 digits; poor, 28 digits). The treatment success rate for Quinnell grade IV was 43.8% (7 of 16), which was significantly lower than those of Quinnell grades II and III, which were 88.9% (88 of 99) and 87.5% (49 of 56), respectively (II vs. IV, p=0.004; III vs. IV, p=0.010). In four fingers (excluding the thumb), the success rate was significantly higher than that of the thumb (88.2% vs. 75.4%, p=0.048).Conclusion: The steroid injection technique using tendon excursion showed excellent results and low complication rates. In particular, the second to fourth fingers and low-grade fingers showed more effective results.


  • Open Access

    Accessory Palmaris Longus Encountered during Carpal Tunnel Surgery: A Case Report

    by Sang Hyun Ko, Jin Seong Park, Tong Joo Lee

    The accessory palmaris longus is a rare anatomical variant in the wrist and forearm, which has been reported as the cause of carpal tunnel syndrome. This paper reports a case of the accessory palmaris longus incidentally found during carpal tunnel surgery. The paucity of awareness on the accessory palmaris longus in carpal tunnel surgery may lead to accidental iatrogenic injury to the median nerve or insufficient decompression of the median nerve.


  • Open Access

    Plate fixation versus titanium elastic nailing in midshaft clavicle fractures based on fracture classifications

    by Jun Sung Park, Sang Hyun Ko, Taek Ho Hong, Dong Jin Ryu, Dae Gyu Kwon, Myung-Ku Kim, Yoon Sang Jeon

    Background: The best strategy for implant selection in midshaft clavicular fractures (MCF) remains controversial. The present study aims to determine the optimal strategy for implant selection by comparing plate and Titanium Elastic Nail (TEN) with respect to outcomes and related complications and analyze the results based on fracture patterns. Methods: A total of 97 patients with MCF who underwent plate (48 patients) or TEN (49 patients) fixation were retrospectively reviewed. Both groups were divided into three subgroups by fracture type using the AO Foundation/Orthopaedic Trauma Association classification: simple fracture (type A), wedge fracture (type B), and multi-fragmentary fracture (type C). The observed outcome measures were bone union rate, related complications, functional scores, and patient satisfaction score. These outcomes were analyzed based on the fracture classification. Results: Both groups demonstrated excellent union rates (p = 0.495) and similar functional scores (p > 0.05). Visual analog scale (VAS) for satisfaction was better in TEN than plate fixation (p < 0.001). In type A and B subgroups, there were no significant difference in functional scores between plate and TEN fixation (p > 0.05). In type C subgroup, however, both VAS for pain and DASH score in TEN fixation were significantly worse than in plate fixation at 2 and 6 weeks postoperatively (p < 0.05). The incidences of clavicle shortening and skin irritation are higher especially in type C subgroup of TEN fixation (p < 0.05). Conclusion: Patient satisfaction of TEN fixation was higher than that of plate fixation, but TEN fixation had a higher incidence of early postoperative pain and migration in type C fractures. Therefore, type A and B fractures can successfully be treated with plate or TEN fixation, but type C fractures should be treated with plate fixation.


  • Open Access

    Comparison of the Clinical Results of Identically Designed Total Knee Prostheses with Different Surface Roughnesses

    by Sang Hyun Ko, Kyoung Ho Moon

    The purpose of this study was to investigate the effects of the undersurface roughness of total knee prosthesis on clinical outcomes. We compared the clinical and radiological outcomes and prosthesis survivals in patients who underwent total knee arthroplasty using prosthesis with identical designs but different surface roughness (average surface roughnesses (Ra), 5.0 μm vs. 11.6 μm). The results showed that the knee prostheses with a more roughened undersurface (Ra = 11.6 μm) produced significantly better functional results and enhanced prosthesis survival. The difference in surface roughness was associated with incidence of osteolysis and loosening at the tibial baseplate, but not at the femoral component. Overall, our results provided significant evidence that the use of roughened undersurface of tibial baseplate would be a way to prevent aseptic loosening.


  • Open Access

    Reply to the Letter to the Editor

    by Joon Soon Kang, Moon Kyoung Ho, Youn Yung Hun, Park Jun Sung, Ko Sang Hyun, Jeon Yoon Sang