Wen Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wen Luo has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Xiao Yang
Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi’an, China
6 shared publicationsHaijing Liu
Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi’an, China
5 shared publicationsLei Ding
Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi Province, China
4 shared publicationsFen Gu
Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, 127 Changle West Rd, Xian 710032, Peoples R China
3 shared publicationsJiani Yuan
Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi Province, China
3 shared publicationsLina Pang
Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi Province, China
3 shared publications
Latest Publications
- Open Access
- 18 August 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
Novel customized 3D-printed prosthesis for complex infected bone defects: a clinical case series
- 18 August 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
Open AccessNovel customized 3D-printed prosthesis for complex infected bone defects: a clinical case series
- Open Access
- 13 May 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (5) , 550
A Lightweight Network for Free Fluid Detection in Focused Assessment with Sonography in Trauma (FAST) Examination
The Focused Assessment with Sonography in Trauma (FAST) enables rapid point-of-care screening for internal hemorrhage by detecting free fluid, but its accuracy is highly operator-dependent and prone to missed diagnoses in emergency settings. While deep learning–based AI assistance can address these limitations, most existing models rely on computationally intensive networks, restricting deployment on resource-limited bedside devices. Thus, developing a lightweight architecture for free fluid detection is essential for clinical translation. We propose a lightweight model based on YOLOX, incorporating a dual-stream fusion (DSF) backbone to preserve spatial details while reducing computation, and a global fusion feedback (GFF) neck to enhance efficient multi-scale feature fusion. We also built a dedicated dataset using ultrasound images from rabbits with active liver hemorrhage to better mimic in vivo sonographic features of free fluid. Compared with mainstream detectors, our method achieves the lowest FLOPs and parameter count while maintaining superior precision, recall, and F1-score. Ablation studies validate that DSF improves accuracy and reduces complexity, and GFF further lowers computational costs with minimal performance tradeoff. The proposed approach enables fast, accurate free fluid detection on constrained bedside devices, advancing intelligent point-of-care trauma assessment.
- 13 May 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (5) , 550
Open AccessA Lightweight Network for Free Fluid Detection in Focused Assessment with Sonography in Trauma (FAST) Examination
The Focused Assessment with Sonography in Trauma (FAST) enables rapid point-of-care screening for internal hemorrhage by detecting free fluid, but its accuracy is highly operator-dependent and prone to missed diagnoses in emergency settings. While deep learning–based AI assistance can address these limitations, most existing models rely on computationally intensive networks, restricting deployment on resource-limited bedside devices. Thus, developing a lightweight architecture for free fluid detection is essential for clinical translation. We propose a lightweight model based on YOLOX, incorporating a dual-stream fusion (DSF) backbone to preserve spatial details while reducing computation, and a global fusion feedback (GFF) neck to enhance efficient multi-scale feature fusion. We also built a dedicated dataset using ultrasound images from rabbits with active liver hemorrhage to better mimic in vivo sonographic features of free fluid. Compared with mainstream detectors, our method achieves the lowest FLOPs and parameter count while maintaining superior precision, recall, and F1-score. Ablation studies validate that DSF improves accuracy and reduces complexity, and GFF further lowers computational costs with minimal performance tradeoff. The proposed approach enables fast, accurate free fluid detection on constrained bedside devices, advancing intelligent point-of-care trauma assessment.
- Open Access
- 10 September 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (1) , 55-70
Expert consensus regarding the clinical application of liver contrast-enhanced US with Sonazoid (Sonazoid CEUS)
Sonazoid, a combined blood pool and Kupffer-cell agent, can be specifically phagocytosed by Kupffer cells in the liver, allowing lesion detection and characterization of focal liver lesions (FLLs) at the post-vascular phase, apart from the vascular phase, which is similar to that of other second-generation ultasound (US) contrast agents. Sonazoid contrast-enhanced US (CEUS) is currently approved for use in some Asian countries. With the increasing use of Sonazoid CEUS for FLLs in clinical practice, developing consensus or guidelines to help standardize its use is required. The expert consensus aimed to review recent evidence and make evidence-based recommendations for radiologists and clinicians involved in the management of liver diseases regarding the use of Sonazoid CEUS in the surveillance or detection, characterization of FLLs, CEUS for interventional and intraoperative use, and tumor treatment response evaluation in patients with FLLs. This consensus was conducted without using artificial intelligence tools in accordance with the TITAN Guidelines 2025.
- 10 September 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (1) , 55-70
Open AccessExpert consensus regarding the clinical application of liver contrast-enhanced US with Sonazoid (Sonazoid CEUS)
Sonazoid, a combined blood pool and Kupffer-cell agent, can be specifically phagocytosed by Kupffer cells in the liver, allowing lesion detection and characterization of focal liver lesions (FLLs) at the post-vascular phase, apart from the vascular phase, which is similar to that of other second-generation ultasound (US) contrast agents. Sonazoid contrast-enhanced US (CEUS) is currently approved for use in some Asian countries. With the increasing use of Sonazoid CEUS for FLLs in clinical practice, developing consensus or guidelines to help standardize its use is required. The expert consensus aimed to review recent evidence and make evidence-based recommendations for radiologists and clinicians involved in the management of liver diseases regarding the use of Sonazoid CEUS in the surveillance or detection, characterization of FLLs, CEUS for interventional and intraoperative use, and tumor treatment response evaluation in patients with FLLs. This consensus was conducted without using artificial intelligence tools in accordance with the TITAN Guidelines 2025.
- Open Access
- 4 October 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-10
A novel 3D printed model for educating medical students on limb fractures: a randomized controlled preliminary study
Medical education related to bone fracture must address numerous challenges including complex anatomical characteristics, diverse injury mechanisms, fracture typing, and treatment modalities. Our newly developed 3D printed model comprises components that may be combined or split to simulate various anatomical features, fracture types, and treatment modalities. This study aims to analyze the teaching utility of the new 3D-printed model compared with the traditional solid model. This prospective study included 112 students randomly assigned to fracture-related education with a conventional model or the newly developed 3D-printed model. All students received 40 min of lecture, 20 min for femoral neck and 20 min for tibiofibular fractures, and a post-class quiz (10 min each) immediately followed. Scores on tests of fracture-related knowledge and user satisfaction were measured pre and post education for comparison. The 3D printing group had an advantage in retention of anatomic knowledge, fracture typing and choice of treatment for the femoral neck fracture (P < 0.05). For the tibiofibular fracture the 3D printing group had an advantage in retention of anatomic knowledge and fracture complications (P < 0.05).Scores on the questionnaire survey also showed increased satisfaction in the 3D-printed model group(P < 0.05). The proposed 3D-printed model can enhance the teaching effect significantly and has potential for widespread use in medical student education.
- 4 October 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-10
Open AccessA novel 3D printed model for educating medical students on limb fractures: a randomized controlled preliminary study
Medical education related to bone fracture must address numerous challenges including complex anatomical characteristics, diverse injury mechanisms, fracture typing, and treatment modalities. Our newly developed 3D printed model comprises components that may be combined or split to simulate various anatomical features, fracture types, and treatment modalities. This study aims to analyze the teaching utility of the new 3D-printed model compared with the traditional solid model. This prospective study included 112 students randomly assigned to fracture-related education with a conventional model or the newly developed 3D-printed model. All students received 40 min of lecture, 20 min for femoral neck and 20 min for tibiofibular fractures, and a post-class quiz (10 min each) immediately followed. Scores on tests of fracture-related knowledge and user satisfaction were measured pre and post education for comparison. The 3D printing group had an advantage in retention of anatomic knowledge, fracture typing and choice of treatment for the femoral neck fracture (P < 0.05). For the tibiofibular fracture the 3D printing group had an advantage in retention of anatomic knowledge and fracture complications (P < 0.05).Scores on the questionnaire survey also showed increased satisfaction in the 3D-printed model group(P < 0.05). The proposed 3D-printed model can enhance the teaching effect significantly and has potential for widespread use in medical student education.
- 22 January 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (4) , 557-563
Development and Validation of a Nomogram Based on Multimodality Ultrasonography Images for Differentiating Malignant from Benign American College of Radiology Thyroid Imaging, Reporting and Data System (TI-RADS) 3–5 Thyroid Nodules
- 22 January 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (4) , 557-563
Development and Validation of a Nomogram Based on Multimodality Ultrasonography Images for Differentiating Malignant from Benign American College of Radiology Thyroid Imaging, Reporting and Data System (TI-RADS) 3–5 Thyroid Nodules
- 25 September 2023
- Published by Elsevier in Journal of Controlled Release
- Vol. 363, 84-100
Thermal/ultrasound-triggered release of liposomes loaded with Ganoderma applanatum polysaccharide from microbubbles for enhanced tumour ablation
- 25 September 2023
- Published by Elsevier in Journal of Controlled Release
- Vol. 363, 84-100
Thermal/ultrasound-triggered release of liposomes loaded with Ganoderma applanatum polysaccharide from microbubbles for enhanced tumour ablation
- Open Access
- 16 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2818
Added Value of Ultrasound-Based Multimodal Imaging to Diagnose Hepatic Sclerosed Hemangioma before Biopsy and Resection
Imaging methods have the overwhelming advantage of being non-invasive in the diagnosis of hepatic lesions and, thanks to technical developments in the field of ultrasound (US), radiation exposure can also be avoided in many clinical situations. In particular, contrast-enhanced US (CEUS) outperforms other radiological methods in regard to real-time images, repeatability, and prompt reporting and demonstrates relatively few contraindications and adverse reactions. In this study, we reported in detail a rare benign tumor: hepatic sclerosed hemangioma (HSH). We described US-based multimodal imaging (B-flow imaging, US elastography, and Sonazoid CEUS) features of this HSH case. Furthermore, by summarizing the recently published literature on the imaging diagnosis of HSH, we offered readers comprehensive knowledge of conventional imaging methods (CT, MRI) and CEUS in the diagnosis of HSH and preliminarily discussed their mechanism of pathology-based diagnosis. Our multimodal imaging approach may provide a diagnostic strategy for HSH, thus avoiding unnecessary biopsy or resection.
- 16 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2818
Open AccessAdded Value of Ultrasound-Based Multimodal Imaging to Diagnose Hepatic Sclerosed Hemangioma before Biopsy and Resection
Imaging methods have the overwhelming advantage of being non-invasive in the diagnosis of hepatic lesions and, thanks to technical developments in the field of ultrasound (US), radiation exposure can also be avoided in many clinical situations. In particular, contrast-enhanced US (CEUS) outperforms other radiological methods in regard to real-time images, repeatability, and prompt reporting and demonstrates relatively few contraindications and adverse reactions. In this study, we reported in detail a rare benign tumor: hepatic sclerosed hemangioma (HSH). We described US-based multimodal imaging (B-flow imaging, US elastography, and Sonazoid CEUS) features of this HSH case. Furthermore, by summarizing the recently published literature on the imaging diagnosis of HSH, we offered readers comprehensive knowledge of conventional imaging methods (CT, MRI) and CEUS in the diagnosis of HSH and preliminarily discussed their mechanism of pathology-based diagnosis. Our multimodal imaging approach may provide a diagnostic strategy for HSH, thus avoiding unnecessary biopsy or resection.
- Open Access
- 7 September 2022
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 12 (11) , 5209-5221
Comparison of contrast-enhanced ultrasound characteristics of inflammatory thyroid nodules and papillary thyroid carcinomas using a quantitative time-intensity curve: a propensity score matching analysis
Original Article Comparison of contrast-enhanced ultrasound characteristics of inflammatory thyroid nodules and papillary thyroid carcinomas using a quantitative time-intensity curve: a propensity score matching analysis Peidi Zhang, Haijing Liu, Xiao Yang, Lina Pang, Fen Gu, Jiani Yuan, Lei Ding, Jun Zhang, Wen Luo
- 7 September 2022
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 12 (11) , 5209-5221
Open AccessComparison of contrast-enhanced ultrasound characteristics of inflammatory thyroid nodules and papillary thyroid carcinomas using a quantitative time-intensity curve: a propensity score matching analysis
Original Article Comparison of contrast-enhanced ultrasound characteristics of inflammatory thyroid nodules and papillary thyroid carcinomas using a quantitative time-intensity curve: a propensity score matching analysis Peidi Zhang, Haijing Liu, Xiao Yang, Lina Pang, Fen Gu, Jiani Yuan, Lei Ding, Jun Zhang, Wen Luo
- 9 November 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (3) , 2110-2119
Role of contrast-enhanced ultrasonography in MR-guided focused ultrasound ablation on uterus fibroids: lesion selection and assessment of ablative effects
Objectives To determine whether contrast-enhanced ultrasonography (CEUS) can be used for selecting lesions and assessing the ablative effects of MRgFUS ablation on uterus fibroids, compared with MR imaging. Methods This retrospective study was approved by the institutional review board of our hospital. From April 2018 to November 2019, a total of 44 symptomatic fibroids in 38 patients who underwent MRgFUS ablation were included. The association between pre-ablation characteristics on CEUS/MR imaging and the non-perfusion volume (NPV) after ablation was analyzed using multivariable linear regression analysis. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve values was compared between the CEUS and MR imaging regression models. NPV after ablation was compared between CEUS and enhanced MR imaging. Results On CEUS, entangled branch vessels, fast-in, and fast-out patterns were significantly associated with NPV, with an AUC of 0.95 (95% CI; 0.88, 1.00). On MR imaging, hyper-intensity on T2-weighted images (T2WI), hyper-intense ring-like signal on T2WI images, and hyper-enhancement on contrast-enhanced T1WI images were correlated with NPV, with an AUC of 0.86 (95% CI; 0.70, 1.00). After ablation, no differences in NPV were noted between contrast-enhanced T1WI (84.13 ± 75.42 cm3) and CEUS (80.22 ± 76.49 cm3). Conclusions Some pre-ablation characteristics of uterine fibroids on CEUS were associated with NPV after MRgFUS. CEUS may contribute to the evaluation of ablative outcomes and patient selection, similar to MR imaging. Key Points • Contrast-enhanced ultrasonography (CEUS) is effective for selecting the appropriate uterine fibroids before MR-guided focused ultrasound (MRgFUS) ablation and evaluating non-perfusion volumes (NPV) after ablation, as a potential alternative to MR imaging. • Before ablation, entangled branch vessels, fast-in, and fast-out patterns on CEUS were significantly associated with NPV after MRgFUS. • No significant differences in NPV were detected between contrast-enhanced T1WI and CEUS after ablation.
- 9 November 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (3) , 2110-2119
Role of contrast-enhanced ultrasonography in MR-guided focused ultrasound ablation on uterus fibroids: lesion selection and assessment of ablative effects
Objectives To determine whether contrast-enhanced ultrasonography (CEUS) can be used for selecting lesions and assessing the ablative effects of MRgFUS ablation on uterus fibroids, compared with MR imaging. Methods This retrospective study was approved by the institutional review board of our hospital. From April 2018 to November 2019, a total of 44 symptomatic fibroids in 38 patients who underwent MRgFUS ablation were included. The association between pre-ablation characteristics on CEUS/MR imaging and the non-perfusion volume (NPV) after ablation was analyzed using multivariable linear regression analysis. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve values was compared between the CEUS and MR imaging regression models. NPV after ablation was compared between CEUS and enhanced MR imaging. Results On CEUS, entangled branch vessels, fast-in, and fast-out patterns were significantly associated with NPV, with an AUC of 0.95 (95% CI; 0.88, 1.00). On MR imaging, hyper-intensity on T2-weighted images (T2WI), hyper-intense ring-like signal on T2WI images, and hyper-enhancement on contrast-enhanced T1WI images were correlated with NPV, with an AUC of 0.86 (95% CI; 0.70, 1.00). After ablation, no differences in NPV were noted between contrast-enhanced T1WI (84.13 ± 75.42 cm3) and CEUS (80.22 ± 76.49 cm3). Conclusions Some pre-ablation characteristics of uterine fibroids on CEUS were associated with NPV after MRgFUS. CEUS may contribute to the evaluation of ablative outcomes and patient selection, similar to MR imaging. Key Points • Contrast-enhanced ultrasonography (CEUS) is effective for selecting the appropriate uterine fibroids before MR-guided focused ultrasound (MRgFUS) ablation and evaluating non-perfusion volumes (NPV) after ablation, as a potential alternative to MR imaging. • Before ablation, entangled branch vessels, fast-in, and fast-out patterns on CEUS were significantly associated with NPV after MRgFUS. • No significant differences in NPV were detected between contrast-enhanced T1WI and CEUS after ablation.