Taner Ceylan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Taner Ceylan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Burak Çıtamak
Hacettepe Univ, Dept Urol, Fac Med, Ankara, Turkey
5 shared publications - Serdar Tekgül
Department of Urology, Hacettepe University Hospital, Ankara, Turkey
5 shared publications - Hasan Serkan Doğan
Hacettepe University Faculty of Medicine, Department of Urology, Division of Pediatric Urology, Ankara, Turkiye
4 shared publications - Ali Cansu Bozacı
Hacettepe Univ, Dept Urol, Fac Med, Ankara, Turkey
2 shared publications - Kamranbay Gasimov
Hacettepe University Hospital, Ankara, Turkey
2 shared publications - Meylis Artykov
Hacettepe Univ, Fac Med, Dept Urol, Ankara, Turkey
2 shared publications
Latest Publications
- 14 September 2022
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 9 (3) , 180-183
A Rational Solution for Megaureter in Infants with Solitary Kidney: Temporary Loop Cutaneous Ureterostomy
- 14 September 2022
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 9 (3) , 180-183
A Rational Solution for Megaureter in Infants with Solitary Kidney: Temporary Loop Cutaneous Ureterostomy
- 1 March 2022
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 9 (1) , 68-73
The Reliability of Bladder Volume Determination in Children Using Portable Ultrasonographic Scanner in Standing Position
- 1 March 2022
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 9 (1) , 68-73
The Reliability of Bladder Volume Determination in Children Using Portable Ultrasonographic Scanner in Standing Position
- 9 June 2021
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 8 (2) , 123-129
Endoscopic Treatment of Vesicoureteral Reflux: Changing Trends Over the Years
- 9 June 2021
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 8 (2) , 123-129
Endoscopic Treatment of Vesicoureteral Reflux: Changing Trends Over the Years
- 9 June 2021
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 8 (2) , 118-122
A Technique Which We Should Consider More: Temporary Cutaneous Ureterostomy
- 9 June 2021
- Published by Galenos Yayinevi in Journal of Urological Surgery
- Vol. 8 (2) , 118-122
A Technique Which We Should Consider More: Temporary Cutaneous Ureterostomy
- Open Access
- 14 April 2021
- Published by Wiley
RELIABILITY OF BLADDER VOLUME DETERMINATION IN CHILDREN BY PORTABLE ULTRASONOGRAPHIC SCANNER IN STANDING POSITION
Aim: We aimed to compare pre-voiding bladder and post-voiding residual (BV, PVR) volumes measured by portable ultrasonic scanner (PUS) in standing and supine positions. Material and Methods: A total of 436 children were included. We composed 2 groups (group-1: PUS vs. volume by catheter, group-2: PUS vs. infused volume during urodynamic study) to evaluate the agreement of PUS measurements with actual bladder volume and then third group (group-3) to analyze the correlation of PUS measurements in standing vs. supine positions. In groups 1 and 2, agreement of measurements were evaluated by paired sample T or Wilcoxon signed rank tests. Following confirmation of agreement, correlations were analyzed by Pearson’s or Spearman’s coefficients in all groups. Interpretation of coefficients were done as 0.90-1.00 (very high correlation) and 0.70-0.90 (high correlation), respectively. Results: In group-1, measurements (catheter vs. PUS) were similar (Wilcoxon Signed rank test, p= 0.976) and were highly correlated (r=0.873). In group-2, measurements of bladder volumes infused by urodynamic device and volumes by PUS were similar that revealed the agreement of PUS measurements on different volumes and highly correlated at the 25th and very highly correlated at the 50th, 75th and 100th percentiles of the EBC (estimated bladder capacity related to age). In group-3, BV and PVR measurements by PUS in standing and supine positions were highly correlated that revelaed PUS can be used in both positions. Conclusion: Measurements of BV before uroflowmetry or PVR volume by PUS in standing position gave similar results with those in supine position.
- 14 April 2021
- Published by Wiley
Open AccessRELIABILITY OF BLADDER VOLUME DETERMINATION IN CHILDREN BY PORTABLE ULTRASONOGRAPHIC SCANNER IN STANDING POSITION
Aim: We aimed to compare pre-voiding bladder and post-voiding residual (BV, PVR) volumes measured by portable ultrasonic scanner (PUS) in standing and supine positions. Material and Methods: A total of 436 children were included. We composed 2 groups (group-1: PUS vs. volume by catheter, group-2: PUS vs. infused volume during urodynamic study) to evaluate the agreement of PUS measurements with actual bladder volume and then third group (group-3) to analyze the correlation of PUS measurements in standing vs. supine positions. In groups 1 and 2, agreement of measurements were evaluated by paired sample T or Wilcoxon signed rank tests. Following confirmation of agreement, correlations were analyzed by Pearson’s or Spearman’s coefficients in all groups. Interpretation of coefficients were done as 0.90-1.00 (very high correlation) and 0.70-0.90 (high correlation), respectively. Results: In group-1, measurements (catheter vs. PUS) were similar (Wilcoxon Signed rank test, p= 0.976) and were highly correlated (r=0.873). In group-2, measurements of bladder volumes infused by urodynamic device and volumes by PUS were similar that revealed the agreement of PUS measurements on different volumes and highly correlated at the 25th and very highly correlated at the 50th, 75th and 100th percentiles of the EBC (estimated bladder capacity related to age). In group-3, BV and PVR measurements by PUS in standing and supine positions were highly correlated that revelaed PUS can be used in both positions. Conclusion: Measurements of BV before uroflowmetry or PVR volume by PUS in standing position gave similar results with those in supine position.