SMSurabhi R. Madhvapathy

Surabhi R. Madhvapathy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Surabhi R. Madhvapathy has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Implantable bioelectronics and wearable sensors for kidney health and disease

    by Surabhi R. Madhvapathy, Soongwon Cho, Elisa Gessaroli, Eleonora Forte, Yirui Xiong, Lorenzo Gallon, John A. Rogers

    Established clinical practices for monitoring kidney health and disease — including biopsy and serum biomarker analysis — suffer from practical limitations in monitoring frequency and lack adequate sensitivity for early disease detection. Engineering advances in biosensors have led to the development of wearable and implantable systems for monitoring of kidney health. Non-invasive microfluidic systems have demonstrated utility in the detection of kidney-relevant biomarkers, such as creatinine, urea and electrolytes in peripheral body fluids such as sweat, interstitial fluid, tears and saliva. Implantable systems may aid the identification of early transplant rejection through analysis of organ temperature and perfusion, and enable real-time assessment of inflammation through the use of thermal sensors. These technologies enable continuous, real-time monitoring of kidney health, offering complementary information to standard clinical procedures to alert physicians of changes in kidney health for early intervention. In this Review, we explore devices for monitoring renal biomarkers in peripheral biofluids and discuss developments in implantable sensors for the direct measurement of the local, biophysical properties of kidney tissue. We also describe potential clinical applications, including monitoring of chronic kidney disease, acute kidney injury and allograft health.


  • Remote optogenetic control of the enteric nervous system and brain-gut axis in freely-behaving mice enabled by a wireless, battery-free optoelectronic device

    by Andrew I. Efimov, Timothy J. Hibberd, Yue Wang, Mingzheng Wu, Kaiqing Zhang, Kaila Ting, Surabhi Madhvapathy, Min-Kyu Lee, Joohee Kim, Jiheon Kang, et al.


  • Top Cited Papers

    Implantable bioelectronic systems for early detection of kidney transplant rejection

    by Surabhi R. Madhvapathy, Jiao-Jing Wang, Heling Wang, Manish Patel, Anthony Chang, Xin Zheng, Yonggang Huang, Zheng J. Zhang, Lorenzo Gallon, John A. Rogers

    Early-stage organ transplant rejection can be difficult to detect. Percutaneous biopsies occur infrequently and are risky, and measuring biomarker levels in blood can lead to false-negative and -positive outcomes. We developed an implantable bioelectronic system capable of continuous, real-time, long-term monitoring of the local temperature and thermal conductivity of a kidney for detecting inflammatory processes associated with graft rejection, as demonstrated in rat models. The system detects ultradian rhythms, disruption of the circadian cycle, and/or a rise in kidney temperature. These provide warning signs of acute kidney transplant rejection that precede changes in blood serum creatinine/urea nitrogen by 2 to 3 weeks and approximately 3 days for cases of discontinued and absent administration of immunosuppressive therapy, respectively.


  • Open Access

    Advanced thermal sensing techniques for characterizing the physical properties of skin

    by Surabhi R. Madhvapathy, Hany M. Arafa, Manish Patel, Joshua Winograd, Jessy Kong, Jason Zhu, Shuai Xu, John A. Rogers

    Measurements of the thermal properties of the skin can serve as the basis for a noninvasive, quantitative characterization of dermatological health and physiological status. Applications range from the detection of subtle spatiotemporal changes in skin temperature associated with thermoregulatory processes, to the evaluation of depth-dependent compositional properties and hydration levels, to the assessment of various features of microvascular/macrovascular blood flow. Examples of recent advances for performing such measurements include thin, skin-interfaced systems that enable continuous, real-time monitoring of the intrinsic thermal properties of the skin beyond its superficial layers, with a path to reliable, inexpensive instruments that offer potential for widespread use as diagnostic tools in clinical settings or in the home. This paper reviews the foundational aspects of the latest thermal sensing techniques with applicability to the skin, summarizes the various devices that exploit these concepts, and provides an overview of specific areas of application in the context of skin health. A concluding section presents an outlook on the challenges and prospects for research in this field.


  • Top Cited Papers

    Wireless sensors for continuous, multimodal measurements at the skin interface with lower limb prostheses

    by Jean Won Kwak, Mengdi Han, Zhaoqian Xie, Ha Uk Chung, Jong Yoon Lee, Raudel Avila, Jessica Yohay, Xuexian Chen, Cunman Liang, Manish Patel, et al.

    Wireless, soft sensors continuously monitor pressure and temperature at the interface between a residual limb and a prosthesis.


  • Open Access

    Reliable, low-cost, fully integrated hydration sensors for monitoring and diagnosis of inflammatory skin diseases in any environment

    by Surabhi R. Madhvapathy, Heling Wang, Jessy Kong, Michael Zhang, Jong Yoon Lee, Jun Bin Park, Hokyung Jang, Zhaoqian Xie, Jingyue Cao, Raudel Avila, et al.

    Present-day dermatological diagnostic tools are expensive, time-consuming, require substantial operational expertise, and typically probe only the superficial layers of skin (~15 μm). We introduce a soft, battery-free, noninvasive, reusable skin hydration sensor (SHS) adherable to most of the body surface. The platform measures volumetric water content (up to ~1 mm in depth) and wirelessly transmits data to any near-field communication–compatible smartphone. The SHS is readily manufacturable, comprises unique powering and encapsulation strategies, and achieves high measurement precision (±5% volumetric water content) and resolution (±0.015°C skin surface temperature). Validation on n = 16 healthy/normal human participants reveals an average skin water content of ~63% across multiple body locations. Pilot studies on patients with atopic dermatitis (AD), psoriasis, urticaria, xerosis cutis, and rosacea highlight the diagnostic capability of the SHS (PAD = 0.0034) and its ability to study impact of topical treatments on skin diseases.


  • Epidermal Electronic Systems for Measuring the Thermal Properties of Human Skin at Depths of up to Several Millimeters

    by Surabhi R. Madhvapathy, Yinji Ma, Manish Patel, Siddharth Krishnan, Chen Wei, Yajing Li, Shuai Xu, Xue Feng, Yonggang Huang, John A. Rogers

    Monitoring the composition, blood flow properties, and hydration status of human skin can be important in diagnosing disease and tracking overall health. Current methods are largely limited to clinical environments, and they primarily measure properties of superficial layers of the skin, such as the stratum corneum (10–40 µm). This work introduces soft, skin‐like thermal depth sensors (e‐TDS) in designs that seamlessly couple with human skin and measure its thermal properties with depth sensitivity that can extend up to 6 mm beneath the surface. Guidelines for tailoring devices to enable measurements through different effective depths follow from a systematic set of experiments, supported by theoretical modeling. On‐body testing validates the physiological relevance of measurements using the e‐TDS platform, with potential to aid the diagnosis of deep cutaneous and systemic diseases. Specific demonstrations include measurements that capture responses ranging from superficial changes in skin properties that result from application of a moisturizer, to changes in microvascular flow at intermediate depths induced by heating/cooling, to detection of inflammation in the deep dermis and subcutaneous fat in an incidence of a local bacterial infection, cellulitis.