Wei Wu
Wei Wu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Tian Mao
Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
2 shared publications Baorong Zhou
State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou, CHINA
1 shared publication- Baorong Zhou
Electric Power Research Institute, China Southern Power Grid, Guangzhou, China
1 shared publication Chao Hong
State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou, CHINA
1 shared publication- Chao Hong
Electric Power Research Institute, China Southern Power Grid, China
1 shared publication Chaojie Li
1 shared publication
Latest Publications
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. PP (08858950) , 1-4
Towards Excessive Short-Circuit Current Suppression via MMC-HVDC: A Stochastic Hybrid AC/DC Transmission Expansion Planning Approach
To overcome the limitations of conventional short- circuit current (SCC) suppression approaches in transmission expansion planning (TEP), this letter proposes a novel SCC-constrained hybrid AC/DC TEP model considering wind uncertainty. To quantify the maximum SCC contribution of MMC, a planning-oriented equivalent current source (ECS) model is developed with different fault-type-dependent magnitudes which could be directly embedded into the TEP. Then, a unified SCC formulation is proposed, integrating the SCC contribution of high voltage alternating current (HVAC) lines, synchronous generators (SGs) and superconducting fault current limiters (SFCLs). Based on the SCC formulation, the proposed stochastic model is cast as a mixed-integer linear programming (MILP) model. Numerical simulations suggest that the proposed formulations are effective in SCC modeling and suppression.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. PP (08858950) , 1-4
Towards Excessive Short-Circuit Current Suppression via MMC-HVDC: A Stochastic Hybrid AC/DC Transmission Expansion Planning Approach
To overcome the limitations of conventional short- circuit current (SCC) suppression approaches in transmission expansion planning (TEP), this letter proposes a novel SCC-constrained hybrid AC/DC TEP model considering wind uncertainty. To quantify the maximum SCC contribution of MMC, a planning-oriented equivalent current source (ECS) model is developed with different fault-type-dependent magnitudes which could be directly embedded into the TEP. Then, a unified SCC formulation is proposed, integrating the SCC contribution of high voltage alternating current (HVAC) lines, synchronous generators (SGs) and superconducting fault current limiters (SFCLs). Based on the SCC formulation, the proposed stochastic model is cast as a mixed-integer linear programming (MILP) model. Numerical simulations suggest that the proposed formulations are effective in SCC modeling and suppression.
- Open Access
- 24 November 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 11, 1320433
Harmonic state estimation and localization based on broad-band measurement
Harmonic and power quality issues brought by the high power electronics penetration level have become a rising threat to power grids. To achieve accurate measurement of the broadband harmonics caused by the power electronic devices, the broadband phasor measurement unit has been developed and installed. However, due to its high cost, it is less practical to install bPMU on each node, and therefore, how to obtain the global harmonic state in the power grid with minimum bPMUs is a crucial issue. This paper is focused on the harmonic state estimation method based on bPMU data. The mathematical model for harmonic state estimation is first derived based on circuit principles. Then, the weighted least squares method is then utilized to solve the established measurement equations for harmonic state estimation to obtain the harmonic state across the grid. Furthermore, the 0–1 integer programming approach is employed to optimize the installation locations of the bPMUs to reduce the overall cost while maintaining full observability. Subsequently, the harmonic sources are localized by analyzing the injected harmonic power on each node. Finally, the validity and effectiveness of the proposed method are proved by matching results between the proposed methods and the simulation model based on the IEEE 14-node system.
- 24 November 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 11, 1320433
Open AccessHarmonic state estimation and localization based on broad-band measurement
Harmonic and power quality issues brought by the high power electronics penetration level have become a rising threat to power grids. To achieve accurate measurement of the broadband harmonics caused by the power electronic devices, the broadband phasor measurement unit has been developed and installed. However, due to its high cost, it is less practical to install bPMU on each node, and therefore, how to obtain the global harmonic state in the power grid with minimum bPMUs is a crucial issue. This paper is focused on the harmonic state estimation method based on bPMU data. The mathematical model for harmonic state estimation is first derived based on circuit principles. Then, the weighted least squares method is then utilized to solve the established measurement equations for harmonic state estimation to obtain the harmonic state across the grid. Furthermore, the 0–1 integer programming approach is employed to optimize the installation locations of the bPMUs to reduce the overall cost while maintaining full observability. Subsequently, the harmonic sources are localized by analyzing the injected harmonic power on each node. Finally, the validity and effectiveness of the proposed method are proved by matching results between the proposed methods and the simulation model based on the IEEE 14-node system.
- Open Access
- 1 June 2020
- Published by Power System Technology Press in CSEE Journal of Power and Energy Systems
- Vol. 7 (1) , 105-113
Frequency control at the power sending side for large-scale HVDC asynchronous interconnection between Yunnan power grid and the rest of CSG
- 1 June 2020
- Published by Power System Technology Press in CSEE Journal of Power and Energy Systems
- Vol. 7 (1) , 105-113
Open AccessFrequency control at the power sending side for large-scale HVDC asynchronous interconnection between Yunnan power grid and the rest of CSG
- 26 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (3) , 1032-1040
Principle and Application of Asynchronous Operation of China Southern Power Grid
The instability induced by high voltage direct current (HVdc) contingencies is challenging operation of ac/dc synchronous system. The asynchronization of ac/dc synchronous system can be a promising strategy for this concern which, however, is lack of practical applications. This paper analyzed the necessity of replacing the existing parallel ac/dc interconnection by pure dc interconnection in China Southern Power Grid (CSG), Guangzhou, China. A comprehensive solution is proposed to mitigate the risk of frequency instability in a small power grid with large amount of power sending out by HVdcs. Meanwhile, the strategy that combines the use of line-commuted converter-HVdc, voltage source converter-HVdc, and flexible ac transmission system is proposed to ensure the secure operation of HVdc feeding in weak ac system. The principle and application of asynchronous operation of CSG provide a reference for other grid development.
- 26 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 6 (3) , 1032-1040
Principle and Application of Asynchronous Operation of China Southern Power Grid
The instability induced by high voltage direct current (HVdc) contingencies is challenging operation of ac/dc synchronous system. The asynchronization of ac/dc synchronous system can be a promising strategy for this concern which, however, is lack of practical applications. This paper analyzed the necessity of replacing the existing parallel ac/dc interconnection by pure dc interconnection in China Southern Power Grid (CSG), Guangzhou, China. A comprehensive solution is proposed to mitigate the risk of frequency instability in a small power grid with large amount of power sending out by HVdcs. Meanwhile, the strategy that combines the use of line-commuted converter-HVdc, voltage source converter-HVdc, and flexible ac transmission system is proposed to ensure the secure operation of HVdc feeding in weak ac system. The principle and application of asynchronous operation of CSG provide a reference for other grid development.