Kuang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kuang Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jing Wang
Doppler Ultrasonic Department, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, China
2 shared publications - Baohua Yu
Department of Pediatric Surgery, Affiliated Hospital of Jining Medical University
1 shared publication - Chen Jin
Pediatric Surgery, The Second Affiliated Hospital of Shandong First Medical University Shandong, Changcheng Road 619#, Taian City, Shandong Province, China
1 shared publication Cheng Xu
Shandong First Medical University, China
1 shared publication- Cheng Xu
Pediatric Surgery, The Second Affiliated Hospital of Shandong First Medical University, Taian City, China
1 shared publication Lefeng Wang
Shandong First Medical University, China
1 shared publication
Latest Publications
- Open Access
- 3 April 2025
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 13, 1559762
A clinical study on the application of three-dimensionally printed splints combined with finite element analysis in paediatric distal radius fractures
Purpose: This single-centre randomised clinical trial assessed the clinical efficacy and patient satisfaction of 3D-printed splints optimised via finite element analysis (FEA) for pediatric distal radius fractures.Methods: This retrospective study included 56 children diagnosed with forearm fractures at our hospital between August 2023 and August 2024. Those who underwent traditional U-shaped forearm plaster immobilisation were compared with those who received a customised 3D-printed splint. FEA was conducted based on the biomechanical characteristics of the forearm; the splint structure was optimised based on the analysis results and created via 3D printing. Outcomes were evaluated using the Patient Satisfaction Questionnaire and Wong-Baker Faces Pain Scale–Revised. Forearm function was evaluated using the Mayo Wrist Score and radiological outcomes. A power calculation was not performed due to the exploratory scope and resource limitations of this preliminary study.Results: The treatment costs significantly differed between the two groups (p = 0.001). In the Patient Satisfaction Questionnaire, the hot and sweaty item showed no significant difference (p = 0.089), whereas the last week's comfort (p = 0.001), first applied comfort (p = 0.004), weight (p = 0.001), itchiness (p = 0.015), smell (p = 0.003), and overall satisfaction items significantly differed between the two groups (p = 0.004). A comparison of the Mayo Wrist Score showed a statistically significant difference between the two groups after external fixation removal (p = 0.044). There were no significant differences between the two groups in terms of the palmar tilt angle (p = 0.196), ulnar deviation angle (p = 0.460), or height of the radial styloid (p = 0.111).Conclusion: Both 3D-printed splint and plaster cast fixation methods can effectively treat distal radial fractures in children, but the 3D-printed splint showed superior patient acceptance.
- 3 April 2025
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 13, 1559762
Open AccessA clinical study on the application of three-dimensionally printed splints combined with finite element analysis in paediatric distal radius fractures
Purpose: This single-centre randomised clinical trial assessed the clinical efficacy and patient satisfaction of 3D-printed splints optimised via finite element analysis (FEA) for pediatric distal radius fractures.Methods: This retrospective study included 56 children diagnosed with forearm fractures at our hospital between August 2023 and August 2024. Those who underwent traditional U-shaped forearm plaster immobilisation were compared with those who received a customised 3D-printed splint. FEA was conducted based on the biomechanical characteristics of the forearm; the splint structure was optimised based on the analysis results and created via 3D printing. Outcomes were evaluated using the Patient Satisfaction Questionnaire and Wong-Baker Faces Pain Scale–Revised. Forearm function was evaluated using the Mayo Wrist Score and radiological outcomes. A power calculation was not performed due to the exploratory scope and resource limitations of this preliminary study.Results: The treatment costs significantly differed between the two groups (p = 0.001). In the Patient Satisfaction Questionnaire, the hot and sweaty item showed no significant difference (p = 0.089), whereas the last week's comfort (p = 0.001), first applied comfort (p = 0.004), weight (p = 0.001), itchiness (p = 0.015), smell (p = 0.003), and overall satisfaction items significantly differed between the two groups (p = 0.004). A comparison of the Mayo Wrist Score showed a statistically significant difference between the two groups after external fixation removal (p = 0.044). There were no significant differences between the two groups in terms of the palmar tilt angle (p = 0.196), ulnar deviation angle (p = 0.460), or height of the radial styloid (p = 0.111).Conclusion: Both 3D-printed splint and plaster cast fixation methods can effectively treat distal radial fractures in children, but the 3D-printed splint showed superior patient acceptance.
- 11 January 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (3) , 773-779
Ultrasound assistance in treatment with elastic stable intramedullary nail fixation in radial and ulnar fractures in children
Purpose Radial and ulnar fractures are one of the most common fractures in children. When closed reduction of fractures fails, elastic stable intramedullary nail (ESIN) fixation can mostly be used under the guidance of fluoroscopy. In this study, we evaluated the effect of ultrasound (US) as assistance for radial and ulnar fracture reduction and the insertion of ESINs. Methods There were 56 patients with midshaft radial and ulnar fractures included in our hospital from March 2019 to August 2021. After applying the inclusion and exclusion criteria and according to the treatment method, they were divided into the US group (patients treated with US assistance) and the conventional group (C-group, patients treated with fluoroscopy guidance). All patients’ clinical data were collected. Operation time, fluoroscopy times, radiation dose, and post-operative complications were analyzed. The elbow function was evaluated using the Mayo Elbow Performance Index. Results There were 26 patients in the US group and 30 in the C-group. The average operation time was 44.5±19.4 min in the US group and 65.1±16.2 min in the C-group. There were significant differences regarding the surgery time, fluoroscopy time, and radiation dose between the groups (all p = 0.001). The average follow-up time was 13.5±3.1 months. No significant difference was found regarding radial nerve injury, extensor pollicis longus rupture, non-union or delayed union, ulnar nerve injury, or acute compartment syndrome. There was no difference in elbow function at the final follow-up. Conclusion US guidance can be adopted for the treatment of displaced radial and ulnar fracture reduction and the insertion of ESINs. It can significantly decrease fluoroscopy times, radiation doses, and duration of surgery.
- 11 January 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (3) , 773-779
Ultrasound assistance in treatment with elastic stable intramedullary nail fixation in radial and ulnar fractures in children
Purpose Radial and ulnar fractures are one of the most common fractures in children. When closed reduction of fractures fails, elastic stable intramedullary nail (ESIN) fixation can mostly be used under the guidance of fluoroscopy. In this study, we evaluated the effect of ultrasound (US) as assistance for radial and ulnar fracture reduction and the insertion of ESINs. Methods There were 56 patients with midshaft radial and ulnar fractures included in our hospital from March 2019 to August 2021. After applying the inclusion and exclusion criteria and according to the treatment method, they were divided into the US group (patients treated with US assistance) and the conventional group (C-group, patients treated with fluoroscopy guidance). All patients’ clinical data were collected. Operation time, fluoroscopy times, radiation dose, and post-operative complications were analyzed. The elbow function was evaluated using the Mayo Elbow Performance Index. Results There were 26 patients in the US group and 30 in the C-group. The average operation time was 44.5±19.4 min in the US group and 65.1±16.2 min in the C-group. There were significant differences regarding the surgery time, fluoroscopy time, and radiation dose between the groups (all p = 0.001). The average follow-up time was 13.5±3.1 months. No significant difference was found regarding radial nerve injury, extensor pollicis longus rupture, non-union or delayed union, ulnar nerve injury, or acute compartment syndrome. There was no difference in elbow function at the final follow-up. Conclusion US guidance can be adopted for the treatment of displaced radial and ulnar fracture reduction and the insertion of ESINs. It can significantly decrease fluoroscopy times, radiation doses, and duration of surgery.
- 20 May 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (11) , 2337-2342
Treatment of displaced radial neck fractures under ultrasonographic guidance in children
Purpose This study aimed to evaluate the feasibility of reduction under ultrasonographic (US) guidance with Kirschner wires (K-wires) and fixation with elastic stable intramedullary nails (ESINs) in the treatment of radial neck fractures (RNFs). Methods This retrospective study included 50 children treated for Judet types III and IV RNFs at our hospital from September 2015 to November 2018. Patients were divided into two groups: group A (without US) and group B (with US). Group A patients were treated using the Métaizeau technique; one K-wire was used for reduction under the guidance of X-ray fluoroscopy. Group B patients were treated using the same technique, but under the guidance of US. Post-operative radiographs, elbow function, and complications were analyzed. Results All patients were followed up over a period of 12 months. Five patients in group A had posterior interosseous nerve (PIN) injury, whereas no patient in group B had PIN injury (p = 0.016). The use of US guidance resulted in lower radiation exposure and shorter operation time. According to the Mayo Elbow Performance Index, there was no significant difference between the two groups (p = 0.814), including post-operative complications (radial head necrosis, fracture displacement, or stiffness). Conclusion US guidance during surgery is feasible to treat Judet type III and IV RNFs. US guidance can significantly reduce X-ray radiation exposure and the risk of PIN injury.
- 20 May 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (11) , 2337-2342
Treatment of displaced radial neck fractures under ultrasonographic guidance in children
Purpose This study aimed to evaluate the feasibility of reduction under ultrasonographic (US) guidance with Kirschner wires (K-wires) and fixation with elastic stable intramedullary nails (ESINs) in the treatment of radial neck fractures (RNFs). Methods This retrospective study included 50 children treated for Judet types III and IV RNFs at our hospital from September 2015 to November 2018. Patients were divided into two groups: group A (without US) and group B (with US). Group A patients were treated using the Métaizeau technique; one K-wire was used for reduction under the guidance of X-ray fluoroscopy. Group B patients were treated using the same technique, but under the guidance of US. Post-operative radiographs, elbow function, and complications were analyzed. Results All patients were followed up over a period of 12 months. Five patients in group A had posterior interosseous nerve (PIN) injury, whereas no patient in group B had PIN injury (p = 0.016). The use of US guidance resulted in lower radiation exposure and shorter operation time. According to the Mayo Elbow Performance Index, there was no significant difference between the two groups (p = 0.814), including post-operative complications (radial head necrosis, fracture displacement, or stiffness). Conclusion US guidance during surgery is feasible to treat Judet type III and IV RNFs. US guidance can significantly reduce X-ray radiation exposure and the risk of PIN injury.