William L. Rowan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
William L. Rowan has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Saeid Houshmandyar
The University of Texas at Austin
7 shared publications - Joseph P. Ziegel
Institute for Fusion Studies, The University of Texas at Austin 1 , Austin, Texas 78712
4 shared publications M. E. Austin
Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78702, USA
3 shared publications- François L. Waelbroeck
University of Texas at Austin
2 shared publications H. Huang
Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712, USA
2 shared publicationsHailin Zhao
Institute of Plasma Physics, Chinese Academy of Sciences 2 , Hefei 230031, China
2 shared publications
Latest Publications
- 14 August 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 232
ITER ECE front-end design, alignment and in-situ calibration
- 14 August 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 232
ITER ECE front-end design, alignment and in-situ calibration
- 13 July 2026
- Published by Taylor & Francis in Fusion Science and Technology
- p. 1-17
Assessing the Role of the ITER ECE’s Oblique View in Resolving Nonthermal Emissions
- 13 July 2026
- Published by Taylor & Francis in Fusion Science and Technology
- p. 1-17
Assessing the Role of the ITER ECE’s Oblique View in Resolving Nonthermal Emissions
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Effects of relativistic broadening on the spatial resolution of electron cyclotron emission measurements for ITER
High temperatures in ITER plasmas result in relativistic broadening of electron cyclotron emission (ECE). Successful use of the ECE diagnostic requires assessment of spatial resolution and determination of accessible regions in the plasma. Using a synthetic diagnostic that has been previously developed and specialized for ITER, the predicted resolution of ECE frequency measurements can be determined. In addition, the fundamental physics describing the ECE behavior can be quantitatively shown to demonstrate the effects of high-temperature scenarios that are uncommon in contemporary devices. This includes the overlap of ECE harmonics that limits accessible regions in the plasma. Such a discussion is useful for the design and engineering of the ECE systems for devices such as ITER. These studies have shown that, for a baseline full-field ITER plasma, ECE X-mode second harmonic has a spatial resolution of <5 cm in the accessible region, meeting ITER requirements. The studies have been expanded to include scenarios spanning the ITER operational range, which provides a general assessment of performance. Low-temperature scenarios show minimal relativistic broadening, which agrees with results from contemporary devices. Higher temperature scenarios (∼40 keV) still allow ECE measurements with spatial resolution (∼15 cm) within ITER requirements for the higher Te range.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Effects of relativistic broadening on the spatial resolution of electron cyclotron emission measurements for ITER
High temperatures in ITER plasmas result in relativistic broadening of electron cyclotron emission (ECE). Successful use of the ECE diagnostic requires assessment of spatial resolution and determination of accessible regions in the plasma. Using a synthetic diagnostic that has been previously developed and specialized for ITER, the predicted resolution of ECE frequency measurements can be determined. In addition, the fundamental physics describing the ECE behavior can be quantitatively shown to demonstrate the effects of high-temperature scenarios that are uncommon in contemporary devices. This includes the overlap of ECE harmonics that limits accessible regions in the plasma. Such a discussion is useful for the design and engineering of the ECE systems for devices such as ITER. These studies have shown that, for a baseline full-field ITER plasma, ECE X-mode second harmonic has a spatial resolution of <5 cm in the accessible region, meeting ITER requirements. The studies have been expanded to include scenarios spanning the ITER operational range, which provides a general assessment of performance. Low-temperature scenarios show minimal relativistic broadening, which agrees with results from contemporary devices. Higher temperature scenarios (∼40 keV) still allow ECE measurements with spatial resolution (∼15 cm) within ITER requirements for the higher Te range.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Erratum: “Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak” [Rev. Sci. Instrum. 93, 113514 (2022)]
In this paper,1 the authors calculated the proportion of Gaussian beam energy in the three times beam waist standard as 99.988%. However, the actual calculation In this paper,1 the authors calculated the proportion of Gaussian beam energy in the three times beam waist standard as 99.988%. However, the actual calculation
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Open AccessErratum: “Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak” [Rev. Sci. Instrum. 93, 113514 (2022)]
In this paper,1 the authors calculated the proportion of Gaussian beam energy in the three times beam waist standard as 99.988%. However, the actual calculation In this paper,1 the authors calculated the proportion of Gaussian beam energy in the three times beam waist standard as 99.988%. However, the actual calculation
- Open Access
- 10 October 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126032
Detecting neoclassical tearing modes in high-temperature ITER plasma scenarios with the ITER prototype electron cyclotron emission diagnostic
Electron cyclotron emission (ECE) diagnostics for ITER serve two key purposes. The diagnostics will measure plasma electron temperature with high spatial and temporal resolution. Additionally, they will be used to detect neoclassical tearing modes (NTMs), a deleterious and nonlinearly unstable mode causing the growth of magnetic ‘seed’ islands. Interpreting ECE requires anticipation of physical limits including frequency cut-offs and harmonic overlap. In high temperature plasmas, the relativistic shift and broadening of the emission must also be considered to accurately reconstruct the electron temperature spatial profile. Accounting for these effects allows ECE diagnostics to be used for accurate measurement of the equilibrium electron temperature profile, as well as fluctuations about this equilibrium. One such fluctuation is caused by the fast radial transport of heat across rotating magnetic islands. ECE diagnostics can detect this change as an oscillation at the plasma rotation frequency to determine the existence and location of NTMs. This paper presents work on a synthetic diagnostic for ECE. The synthetic diagnostic tests simulated ECE signals, which are inferred from ITER scenarios perturbed by magnetic islands after accounting for all ECE physics. The synthetic diagnostic tests conventional ECE detection algorithms for NTMs in real-time on ITER-recommended hardware. Combined, these two areas of focus help determine design of the ECE system.
- 10 October 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126032
Open AccessDetecting neoclassical tearing modes in high-temperature ITER plasma scenarios with the ITER prototype electron cyclotron emission diagnostic
Electron cyclotron emission (ECE) diagnostics for ITER serve two key purposes. The diagnostics will measure plasma electron temperature with high spatial and temporal resolution. Additionally, they will be used to detect neoclassical tearing modes (NTMs), a deleterious and nonlinearly unstable mode causing the growth of magnetic ‘seed’ islands. Interpreting ECE requires anticipation of physical limits including frequency cut-offs and harmonic overlap. In high temperature plasmas, the relativistic shift and broadening of the emission must also be considered to accurately reconstruct the electron temperature spatial profile. Accounting for these effects allows ECE diagnostics to be used for accurate measurement of the equilibrium electron temperature profile, as well as fluctuations about this equilibrium. One such fluctuation is caused by the fast radial transport of heat across rotating magnetic islands. ECE diagnostics can detect this change as an oscillation at the plasma rotation frequency to determine the existence and location of NTMs. This paper presents work on a synthetic diagnostic for ECE. The synthetic diagnostic tests simulated ECE signals, which are inferred from ITER scenarios perturbed by magnetic islands after accounting for all ECE physics. The synthetic diagnostic tests conventional ECE detection algorithms for NTMs in real-time on ITER-recommended hardware. Combined, these two areas of focus help determine design of the ECE system.
- Open Access
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Electron cyclotron emission detection of neoclassical tearing modes for control for ITER
Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Open AccessElectron cyclotron emission detection of neoclassical tearing modes for control for ITER
Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.
- Open Access
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113514
Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak
COMPASS Upgrade is a medium size and high field tokamak that is capable of addressing key challenges for reactor grade tokamaks, including power exhaust and advanced confinement scenarios. Electron cyclotron emission will be available among the first diagnostics to provide measurements of high spatial and temporal resolution of electron temperature profiles and electron temperature fluctuation profiles through a radial view. A separate oblique view at 12° from normal will be utilized to study non-thermal electrons. Both the radial and oblique views are envisioned to be located in a wide-angle midplane port, which has dimensions that enable simultaneous hosting of the front-end of their quasi-optical (QO) designs. Each QO design will have an in situ hot calibration source in the front-end to provide standalone and calibrated Te (R,t) measurements. The conceptual design for each QO system, the Gaussian beam analysis, and the details of the diagnostic channels are presented.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113514
Open AccessDesign of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak
COMPASS Upgrade is a medium size and high field tokamak that is capable of addressing key challenges for reactor grade tokamaks, including power exhaust and advanced confinement scenarios. Electron cyclotron emission will be available among the first diagnostics to provide measurements of high spatial and temporal resolution of electron temperature profiles and electron temperature fluctuation profiles through a radial view. A separate oblique view at 12° from normal will be utilized to study non-thermal electrons. Both the radial and oblique views are envisioned to be located in a wide-angle midplane port, which has dimensions that enable simultaneous hosting of the front-end of their quasi-optical (QO) designs. Each QO design will have an in situ hot calibration source in the front-end to provide standalone and calibrated Te (R,t) measurements. The conceptual design for each QO system, the Gaussian beam analysis, and the details of the diagnostic channels are presented.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033510
Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks
Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 µs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. The data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033510
Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks
Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 µs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. The data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D135
Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal
The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. The new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D135
Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal
The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. The new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.
- 29 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10H111
Upgrade of the ECE diagnostic on EAST
The electron cyclotron emission (ECE) diagnostic on the experimental advanced superconducting tokamak (EAST) was upgraded recently to provide electron temperature profile measurement with wider radial coverage and better precision. The lower limit of the ECE detection frequency band was extended from 104 GHz to 97 GHz by adding a new 8-channel heterodyne radiometer, which ensures capability for the measurement of the second harmonic ECE with toroidal magnetic field down to 1.75 T. Also, the existing 32-channel heterodyne radiometer has been upgraded, with the frequency interval for the lower frequency range up to 120 GHz reduced from 2 GHz to 1 GHz by introducing eight channels in the intermediate frequency part. In addition, a plan is presented to incorporate tunable yttrium iron garnet filters into the existing heterodyne radiometer to obtain detailed measurements of the electron temperature gradient scale length as well as finer spatial pinpointing of magnetohydrodynamic modes. Examples from DIII-D are provided where similar ECE diagnostic allowed precise measurement of the center and width of neoclassical tearing modes.
- 29 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10H111
Upgrade of the ECE diagnostic on EAST
The electron cyclotron emission (ECE) diagnostic on the experimental advanced superconducting tokamak (EAST) was upgraded recently to provide electron temperature profile measurement with wider radial coverage and better precision. The lower limit of the ECE detection frequency band was extended from 104 GHz to 97 GHz by adding a new 8-channel heterodyne radiometer, which ensures capability for the measurement of the second harmonic ECE with toroidal magnetic field down to 1.75 T. Also, the existing 32-channel heterodyne radiometer has been upgraded, with the frequency interval for the lower frequency range up to 120 GHz reduced from 2 GHz to 1 GHz by introducing eight channels in the intermediate frequency part. In addition, a plan is presented to incorporate tunable yttrium iron garnet filters into the existing heterodyne radiometer to obtain detailed measurements of the electron temperature gradient scale length as well as finer spatial pinpointing of magnetohydrodynamic modes. Examples from DIII-D are provided where similar ECE diagnostic allowed precise measurement of the center and width of neoclassical tearing modes.