Anass Benomar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anass Benomar has a total of 296 co-authors. Here are the top co-authors by number of shared publications:
- Jean Raymond
Department of Radiology, service of Neuroradiology, Centre hospitalier de l'Université de Montréal (CHUM), Montreal, Quebec, Canada
10 shared publications - Daniel Roy
Centre Hospitalier de l’Université de Montréal, Montreal, Canada
8 shared publications - William Boisseau
Interventional Neuroradiology Department, Hôpital Fondation A. de Rothschild, Paris, France
8 shared publications - Robert Fahed
Department of Medicine (Neurology), The Ottawa Hospital, Canada
7 shared publications - Tim E. Darsaut
University of Alberta Hospital
6 shared publications - Jose Danilo Bengzon Diestro
Neurovascular Centre and RADIS Lab (Robotics, Artificial Intelligence, Dynamic Flow, Imaging and Simulation), St. Michael’s Hospital, Unity Health Toronto, University of Toronto and Toronto Metropolitan University, ON, Canada (D.A.O., N.C., J.D.D., J.S., T.M., V.M.P.).
5 shared publications
Latest Publications
- 14 August 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Clinical recurrence and rebound intracranial hypertension after transvenous embolization of cerebrospinal fluid–venous fistulas
Background and objectives: Cerebrospinal fluid-venous fistula (CVF) is an increasingly recognized cause of spontaneous intracranial hypotension (SIH). We report our single-center retrospective experience with transvenous CVF embolization, focusing on clinical and imaging outcomes, recurrence, and rebound intracranial hypertension (RIH). Methods: We selected patients who underwent transvenous embolization for CVF between January 2022 and January 2026. Inclusion required a clinical diagnosis of SIH, confirmation of CVF on decubitus myelographic imaging, and completion of transvenous embolization. Brain MRI was scored using the Bern SIH score. Outcomes included immediate post-procedural response, symptom resolution at 3 months, RIH, recurrence, procedural complications, and final clinical outcome. Results: Forty-six patients were included in the primary analysis. Brain MRI features of SIH were present in just over half of patients. Symptom resolution at 3 months was achieved in 80.4%, while overall RIH occurred in 26.1%. Among evaluable patients, recurrence occurred in 18.9%. One procedural complication occurred without lasting clinical sequelae. In patients with available post-treatment MRI, Bern score improved after embolization. Discussion: Transvenous CVF embolization was associated with favorable clinical and imaging outcomes. Brain MRI status showed a consistent directional association with outcome, rebound intracranial hypertension and SIH recurrence.
- 14 August 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Clinical recurrence and rebound intracranial hypertension after transvenous embolization of cerebrospinal fluid–venous fistulas
Background and objectives: Cerebrospinal fluid-venous fistula (CVF) is an increasingly recognized cause of spontaneous intracranial hypotension (SIH). We report our single-center retrospective experience with transvenous CVF embolization, focusing on clinical and imaging outcomes, recurrence, and rebound intracranial hypertension (RIH). Methods: We selected patients who underwent transvenous embolization for CVF between January 2022 and January 2026. Inclusion required a clinical diagnosis of SIH, confirmation of CVF on decubitus myelographic imaging, and completion of transvenous embolization. Brain MRI was scored using the Bern SIH score. Outcomes included immediate post-procedural response, symptom resolution at 3 months, RIH, recurrence, procedural complications, and final clinical outcome. Results: Forty-six patients were included in the primary analysis. Brain MRI features of SIH were present in just over half of patients. Symptom resolution at 3 months was achieved in 80.4%, while overall RIH occurred in 26.1%. Among evaluable patients, recurrence occurred in 18.9%. One procedural complication occurred without lasting clinical sequelae. In patients with available post-treatment MRI, Bern score improved after embolization. Discussion: Transvenous CVF embolization was associated with favorable clinical and imaging outcomes. Brain MRI status showed a consistent directional association with outcome, rebound intracranial hypertension and SIH recurrence.
- 29 April 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Automated perfusion imaging did not improve reliability of ASPECTS or collateral score in late-window large vessel occlusion stroke
Background: The Alberta Stroke Program Early CT Score (ASPECTS) and CT angiography (CTA) Collateral Score (CS) are routinely used to estimate ischemic core burden and collateral status in acute ischemic stroke due to large vessel occlusion, but suffer from limited reliability. Whether automated CT perfusion (CTP) maps improve scoring consistency remains unclear. Objectives: To assess the reliability of these scores on non-contrast computed tomography (NCCT) and CTA among numerous raters, with and without access to automated perfusion maps, and their correlations with endovascular thrombectomy (EVT) decisions. Methods: Twenty-nine clinicians independently rated 60 imaging cases from 30 late-window stroke patients with large vessel occlusion, each presented twice: once using NCCT and CTA alone (‘non-CTP cases’), and once with the addition of perfusion maps (‘CTP cases’). Twenty-eight raters (97%) completed the survey twice. Inter- and intra-reliability was assessed using Gwet’s AC1/2 coefficients (κ G ). Correlations with EVT decisions were evaluated using Cramer V. Results: Inter-rater reliability for ASPECTS was substantial and similar between non-CTP (κ G = 0.65, 95% CI: 0.53 to 0.78) and CTP cases (κ G = 0.64, 95% CI: 0.51 to 0.77). CS showed an almost perfect reliability in both scenarios (κ G = 0.82 and 0.83). Intra-rater agreement was at least substantial. Dichotomizing ASPECTS as 0-2/3-10 improved reliability to almost perfect. ASPECTS strongly correlated with EVT decisions (V=0.80), whereas CS showed moderate correlation (V=0.56), both remaining similar with the addition of CTP (V=0.75 and 0.54, respectively). Conclusion: Automated perfusion imaging did not improve the reliability of ASPECTS or CS. Strong reliability was achieved with NCCT and CTA alone.
- 29 April 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Automated perfusion imaging did not improve reliability of ASPECTS or collateral score in late-window large vessel occlusion stroke
Background: The Alberta Stroke Program Early CT Score (ASPECTS) and CT angiography (CTA) Collateral Score (CS) are routinely used to estimate ischemic core burden and collateral status in acute ischemic stroke due to large vessel occlusion, but suffer from limited reliability. Whether automated CT perfusion (CTP) maps improve scoring consistency remains unclear. Objectives: To assess the reliability of these scores on non-contrast computed tomography (NCCT) and CTA among numerous raters, with and without access to automated perfusion maps, and their correlations with endovascular thrombectomy (EVT) decisions. Methods: Twenty-nine clinicians independently rated 60 imaging cases from 30 late-window stroke patients with large vessel occlusion, each presented twice: once using NCCT and CTA alone (‘non-CTP cases’), and once with the addition of perfusion maps (‘CTP cases’). Twenty-eight raters (97%) completed the survey twice. Inter- and intra-reliability was assessed using Gwet’s AC1/2 coefficients (κ G ). Correlations with EVT decisions were evaluated using Cramer V. Results: Inter-rater reliability for ASPECTS was substantial and similar between non-CTP (κ G = 0.65, 95% CI: 0.53 to 0.78) and CTP cases (κ G = 0.64, 95% CI: 0.51 to 0.77). CS showed an almost perfect reliability in both scenarios (κ G = 0.82 and 0.83). Intra-rater agreement was at least substantial. Dichotomizing ASPECTS as 0-2/3-10 improved reliability to almost perfect. ASPECTS strongly correlated with EVT decisions (V=0.80), whereas CS showed moderate correlation (V=0.56), both remaining similar with the addition of CTP (V=0.75 and 0.54, respectively). Conclusion: Automated perfusion imaging did not improve the reliability of ASPECTS or CS. Strong reliability was achieved with NCCT and CTA alone.
- 12 March 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- p. ajnr.A9294
Volumetric Postcontrast T1 Turbo Spin-Echo versus Gradient-Recalled Echo MR sequences for Detecting Brain Metastases: a Systematic Review and Meta-analysis
Contrast-enhanced 3D T1-weighted MRI is the imaging reference for detection and follow-up of brain metastases. Volumetric GRE-based sequences, such as MPRAGE, are widely used but remain prone to susceptibility and lower lesion conspicuity. 3D black-blood TSE-based sequences, such as Sampling Perfection with Application-Optimized Contrasts by using different flip angle Evolutions (SPACE), have been increasingly embedded into routine workflow and are thought to improve lesion detection in part through vessel signal suppression. We aimed to investigate the comparative diagnostic performance of 3D T1 TSE versus GRE sequences for the detection of brain metastases. Studies comparing the diagnostic performance of postcontrast 3D T1 SE and GRE sequences in adults with brain metastases were searched on MEDLINE, EMBASE, Cochrane Central, Google Scholar, and PROSPERO, from inception through April 2025. Fifteen studies encompassing 544 patients with 4338 metastases were included. Data on diagnostic accuracy parameters, image quality, and inter-rater agreement were extracted. Random-effects models were applied to compute pooled sensitivity and comparative OR for lesion detection. Risk of bias was assessed using QUADAS-2 and QUADAS-C tools. Pooled sensitivities for detection of brain metastases were 97.4% (95%CI, 93.2%-99.0%) for TSE and 76.1% (95%CI, 69.3-81.9) for GRE-based sequences, with a comparative OR of 12.0 (95%CI, 5.45-26.6, P <.0001). Detectability of small lesions (<5 mm) was significantly better on TSE (96.1%; 95%CI, 87.7-98.8) than GRE (58.4%; 95%CI, 47.9-68.2), while both techniques performed comparably for larger (≥5 mm) lesions (98.2% for TSE, 94.4% for GRE). OR estimates were 17.2 (95%CI, 4.50-66.1) for small and 2.81 (95%CI, 0.92-8.56) for large lesions. Contrast-to-noise-ratio and inter-rater agreements were slightly higher on TSE than GRE. False positives were more common with TSE, mostly related to incomplete vessel suppression (49 FP counts in TSE, 35 in GRE). Our meta-analysis is limited by high heterogeneity, case-only studies, possible small-study effects, and high risk of bias for the reference standard domain. Postcontrast 3D T1 TSE sequences provide higher sensitivity and improved lesion conspicuity compared with GRE sequence, particularly for small metastases, though at the cost of slightly higher false positives.
- 12 March 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- p. ajnr.A9294
Volumetric Postcontrast T1 Turbo Spin-Echo versus Gradient-Recalled Echo MR sequences for Detecting Brain Metastases: a Systematic Review and Meta-analysis
Contrast-enhanced 3D T1-weighted MRI is the imaging reference for detection and follow-up of brain metastases. Volumetric GRE-based sequences, such as MPRAGE, are widely used but remain prone to susceptibility and lower lesion conspicuity. 3D black-blood TSE-based sequences, such as Sampling Perfection with Application-Optimized Contrasts by using different flip angle Evolutions (SPACE), have been increasingly embedded into routine workflow and are thought to improve lesion detection in part through vessel signal suppression. We aimed to investigate the comparative diagnostic performance of 3D T1 TSE versus GRE sequences for the detection of brain metastases. Studies comparing the diagnostic performance of postcontrast 3D T1 SE and GRE sequences in adults with brain metastases were searched on MEDLINE, EMBASE, Cochrane Central, Google Scholar, and PROSPERO, from inception through April 2025. Fifteen studies encompassing 544 patients with 4338 metastases were included. Data on diagnostic accuracy parameters, image quality, and inter-rater agreement were extracted. Random-effects models were applied to compute pooled sensitivity and comparative OR for lesion detection. Risk of bias was assessed using QUADAS-2 and QUADAS-C tools. Pooled sensitivities for detection of brain metastases were 97.4% (95%CI, 93.2%-99.0%) for TSE and 76.1% (95%CI, 69.3-81.9) for GRE-based sequences, with a comparative OR of 12.0 (95%CI, 5.45-26.6, P <.0001). Detectability of small lesions (<5 mm) was significantly better on TSE (96.1%; 95%CI, 87.7-98.8) than GRE (58.4%; 95%CI, 47.9-68.2), while both techniques performed comparably for larger (≥5 mm) lesions (98.2% for TSE, 94.4% for GRE). OR estimates were 17.2 (95%CI, 4.50-66.1) for small and 2.81 (95%CI, 0.92-8.56) for large lesions. Contrast-to-noise-ratio and inter-rater agreements were slightly higher on TSE than GRE. False positives were more common with TSE, mostly related to incomplete vessel suppression (49 FP counts in TSE, 35 in GRE). Our meta-analysis is limited by high heterogeneity, case-only studies, possible small-study effects, and high risk of bias for the reference standard domain. Postcontrast 3D T1 TSE sequences provide higher sensitivity and improved lesion conspicuity compared with GRE sequence, particularly for small metastases, though at the cost of slightly higher false positives.
- 1 June 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (3) , e250030
Pentalogy of Cantrell with Complete Ectopia Cordis
- 1 June 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (3) , e250030
Pentalogy of Cantrell with Complete Ectopia Cordis
- 7 May 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (6) , 1585-1591
Angiographic results of aneurysms treated with Woven EndoBridge (WEB) devices or coils: an inter- and intra-observer reliability study
Background Angiographic results are commonly used to evaluate and compare the treatment of aneurysms. We sought to determine and compare the reliability and clinical implications of a commonly used 3-point angiographic outcome scale for aneurysms treated with WEB or endovascular coils. Methods An electronic portfolio of 60 aneurysms (30 treated with WEB devices and 30 with coils) was evaluated by 32 raters of various training backgrounds, who were asked to grade angiographic results and provide management recommendations (delayed follow-up, close follow-up, or re-treatment). Twenty-five raters performed a second evaluation of permuted cases at least a month later. Agreement was analyzed with Gwet’s AC2 (κG) reliability coefficients and the relationship between angiographic grade and management recommendation using Cramer’s V. Results Inter-rater agreement was substantial for occlusion grade (κG = 0.78; 95%CI: 0.74–0.82) and management decision (κG = 0.79; 95%CI: 0.74–0.84). Agreement was substantial and similar for angiographic results of WEB-treated (κG = 0.78; 95%CI: 0.79–0.85) and coiled aneurysms (κG = 0.79; 95%CI: 0.74–0.83). Inter-rater agreement on management decisions was substantial for both WEB-treated aneurysms (κG = 0.79; 95%CI: 0.73–0.85) and coiled aneurysms (κG = 0.79; 95%CI: 0.73–0.85). Mean intra-rater agreement was substantial or almost perfect. There was strong correlation between angiographic grade and management recommendation (mean Cramer’s V = 0.77, SD: 0.12). The meaning of each category of the scale in terms of further management was the same, whether treatment was with WEB or coils. Conclusion A commonly used 3-point scale was shown to be a reliable tool to compare the results of aneurysms treated with WEB devices or endovascular coils.
- 7 May 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (6) , 1585-1591
Angiographic results of aneurysms treated with Woven EndoBridge (WEB) devices or coils: an inter- and intra-observer reliability study
Background Angiographic results are commonly used to evaluate and compare the treatment of aneurysms. We sought to determine and compare the reliability and clinical implications of a commonly used 3-point angiographic outcome scale for aneurysms treated with WEB or endovascular coils. Methods An electronic portfolio of 60 aneurysms (30 treated with WEB devices and 30 with coils) was evaluated by 32 raters of various training backgrounds, who were asked to grade angiographic results and provide management recommendations (delayed follow-up, close follow-up, or re-treatment). Twenty-five raters performed a second evaluation of permuted cases at least a month later. Agreement was analyzed with Gwet’s AC2 (κG) reliability coefficients and the relationship between angiographic grade and management recommendation using Cramer’s V. Results Inter-rater agreement was substantial for occlusion grade (κG = 0.78; 95%CI: 0.74–0.82) and management decision (κG = 0.79; 95%CI: 0.74–0.84). Agreement was substantial and similar for angiographic results of WEB-treated (κG = 0.78; 95%CI: 0.79–0.85) and coiled aneurysms (κG = 0.79; 95%CI: 0.74–0.83). Inter-rater agreement on management decisions was substantial for both WEB-treated aneurysms (κG = 0.79; 95%CI: 0.73–0.85) and coiled aneurysms (κG = 0.79; 95%CI: 0.73–0.85). Mean intra-rater agreement was substantial or almost perfect. There was strong correlation between angiographic grade and management recommendation (mean Cramer’s V = 0.77, SD: 0.12). The meaning of each category of the scale in terms of further management was the same, whether treatment was with WEB or coils. Conclusion A commonly used 3-point scale was shown to be a reliable tool to compare the results of aneurysms treated with WEB devices or endovascular coils.
- 1 February 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (2) , e250211
Another Step toward Thrombectomy for All Patients with Severe Ischemic Stroke
- 1 February 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (2) , e250211
Another Step toward Thrombectomy for All Patients with Severe Ischemic Stroke
- 20 December 2024
- Published by Springer Nature in Neuroradiology
- Vol. 67 (1) , 191-199
Reliability and applicability of angiographic outcome scales in WEB device-treated aneurysms: a systematic review
Purpose Various angiographic assessment scales have been used to report the results of endovascular treatment with the WEB device. We aimed to review the use and reliability of these scales. Methods We systematically reviewed studies reporting angiographic outcomes of WEB-treated aneurysms from January 2010 to May 2023. We identified the studies that reported the reliability of the various scales. Data from eligible studies were extracted and evaluated by two independent reviewers, with discrepancies resolved by a third reviewer. Findings The review identified 138 studies that used 12 different occlusion scales. The non-specific Raymond-Roy occlusion classification (RROC) was most commonly used (94/138 (68%)), followed by the Bicêtre Occlusion Scale Score (BOSS; 21/138 (15%)) and the Web Occlusion Scale (WOS; 16/138 (12%)), both specifically adapted to the WEB. Six reliability studies were identified, which included 16–30 cases evaluated by few (2–7) raters. Studies were too heterogenous to proceed with a meta-analysis. Substantial agreement in reporting angiographic results was shown in one study using the WOS (K = 0.70; 0.64–0.75), and one using the BOSS (K = 0.82; 0.68–0.96), but only when categories were dichotomized as complete versus incomplete occlusion. Most classifications can be translated into the RROC, allowing comparisons with other devices and treatment modalities. The RROC reached substantial agreement, but only between 2 raters in a small 26-patient study (k = 0.69; 0.46–0.93). Conclusion More agreement studies are needed to validate the reliability of angiographic outcome scales that can be used to compare WEB with other endovascular or surgical treatments.
- 20 December 2024
- Published by Springer Nature in Neuroradiology
- Vol. 67 (1) , 191-199
Reliability and applicability of angiographic outcome scales in WEB device-treated aneurysms: a systematic review
Purpose Various angiographic assessment scales have been used to report the results of endovascular treatment with the WEB device. We aimed to review the use and reliability of these scales. Methods We systematically reviewed studies reporting angiographic outcomes of WEB-treated aneurysms from January 2010 to May 2023. We identified the studies that reported the reliability of the various scales. Data from eligible studies were extracted and evaluated by two independent reviewers, with discrepancies resolved by a third reviewer. Findings The review identified 138 studies that used 12 different occlusion scales. The non-specific Raymond-Roy occlusion classification (RROC) was most commonly used (94/138 (68%)), followed by the Bicêtre Occlusion Scale Score (BOSS; 21/138 (15%)) and the Web Occlusion Scale (WOS; 16/138 (12%)), both specifically adapted to the WEB. Six reliability studies were identified, which included 16–30 cases evaluated by few (2–7) raters. Studies were too heterogenous to proceed with a meta-analysis. Substantial agreement in reporting angiographic results was shown in one study using the WOS (K = 0.70; 0.64–0.75), and one using the BOSS (K = 0.82; 0.68–0.96), but only when categories were dichotomized as complete versus incomplete occlusion. Most classifications can be translated into the RROC, allowing comparisons with other devices and treatment modalities. The RROC reached substantial agreement, but only between 2 raters in a small 26-patient study (k = 0.69; 0.46–0.93). Conclusion More agreement studies are needed to validate the reliability of angiographic outcome scales that can be used to compare WEB with other endovascular or surgical treatments.
- Open Access
- 25 November 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (2) , 1018-1022
The path of least resistance: The unusual extradigestive journey of a nasogastric tube following oropharyngeal perforation
- 25 November 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (2) , 1018-1022
Open AccessThe path of least resistance: The unusual extradigestive journey of a nasogastric tube following oropharyngeal perforation
- Open Access
- 10 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4751-4754
Giant metastatic mixed-type spinal ependymoma presenting with hydrocephalus
- 10 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4751-4754
Open AccessGiant metastatic mixed-type spinal ependymoma presenting with hydrocephalus
- 7 March 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (2) , 192-199
Clinical uncertainty in large vessel occlusion ischemic stroke: does automated perfusion imaging make a difference? An intra-rater and inter-rater agreement study
Background: Limited research exists regarding the impact of neuroimaging on endovascular thrombectomy (EVT) decisions for late-window cases of large vessel occlusion (LVO) stroke.Objective: T0 assess whether perfusion CT imaging: (1) alters the proportion of recommendations for EVT, and (2) enhances the reliability of EVT decision-making compared with non-contrast CT and CT angiography.Methods: We conducted a survey using 30 patients drawn from an institutional database of 3144 acute stroke cases. These were presented to 29 Canadian physicians with and without perfusion imaging. We used non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κG).Results: The percentage of EVT recommendations differed by 1.1% with or without perfusion imaging. Individual decisions changed in 21.4% of cases (11.3% against EVT and 10.1% in favor). Inter-rater agreement (κG) among the 29 raters was similar between non-perfusion and perfusion CT neuroimaging (κG=0.487; 95% CI 0.327 to 0.647 and κG=0.552; 95% CI 0.430 to 0.675). The 95% CIs overlapped with moderate agreement in both. Intra-rater agreement exhibited overlapping 95% CIs for all 28 raters. κGwas either substantial or excellent (0.81–1) for 71.4% (20/28) of raters in both groups.Conclusions: Despite the minimal difference in overall EVT recommendations with either neuroimaging protocol one in five decisions changed with perfusion imaging. Regarding agreement we found that the use of automated CT perfusion images does not significantly impact the reliability of EVT decisions for patients with late-window LVO.
- 7 March 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (2) , 192-199
Clinical uncertainty in large vessel occlusion ischemic stroke: does automated perfusion imaging make a difference? An intra-rater and inter-rater agreement study
Background: Limited research exists regarding the impact of neuroimaging on endovascular thrombectomy (EVT) decisions for late-window cases of large vessel occlusion (LVO) stroke.Objective: T0 assess whether perfusion CT imaging: (1) alters the proportion of recommendations for EVT, and (2) enhances the reliability of EVT decision-making compared with non-contrast CT and CT angiography.Methods: We conducted a survey using 30 patients drawn from an institutional database of 3144 acute stroke cases. These were presented to 29 Canadian physicians with and without perfusion imaging. We used non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κG).Results: The percentage of EVT recommendations differed by 1.1% with or without perfusion imaging. Individual decisions changed in 21.4% of cases (11.3% against EVT and 10.1% in favor). Inter-rater agreement (κG) among the 29 raters was similar between non-perfusion and perfusion CT neuroimaging (κG=0.487; 95% CI 0.327 to 0.647 and κG=0.552; 95% CI 0.430 to 0.675). The 95% CIs overlapped with moderate agreement in both. Intra-rater agreement exhibited overlapping 95% CIs for all 28 raters. κGwas either substantial or excellent (0.81–1) for 71.4% (20/28) of raters in both groups.Conclusions: Despite the minimal difference in overall EVT recommendations with either neuroimaging protocol one in five decisions changed with perfusion imaging. Regarding agreement we found that the use of automated CT perfusion images does not significantly impact the reliability of EVT decisions for patients with late-window LVO.