Huiwen He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huiwen He has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hongkun Chen
Hubei Engineering and Technology Research Center for AC/DC Intelligent Distribution Network, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
6 shared publications - Lei Chen
School of Electrical Engineering and Automation Wuhan University Wuhan China
6 shared publications - Guocheng Li
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications - Jun Yang
Hubei Engineering and Technology Research Center for AC/DC Intelligent Distribution Network, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications - Li Ren
Huazhong University of Science and Technology
3 shared publications - Ying Xu
Huazhong University of Science and Technology
3 shared publications
Latest Publications
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-7
Study of Modified Flux-Coupling-Type SFCLs For Stability Improvement of a Multi-Machine Power System Based On Energy Function
This paper investigates modified ux-coupling-type superconducting fault current limiters (SFCLs) for enhancing the transient stability of a multi-machine power system (MMPS). The clustering architecture of the MMPS with the modified SFCLs is presented, and the transient energy function (TEF) of the MMPS is established. Through clarifying the potential influence of the modified SFCLs, theoretical analysis signifies that the modified SFCLs can reduce the transient energy accumulation during the fault-feeding period, and increase the transient stability margin of the MMPS. Using MATLAB/Simulink, a benchmark IEEE 9-bus system with the SFCLs is modeled, and the simulation analysis of the generator rotor swing behaviors is carried out. Varying the resistive-inductive parameters and altering the positions of the SFCLs are considered, and the TEF method is applied to gain quantitative effects. The simulation findings in different scenarios testify the correctness of the theoretical analysis. The presence of the SFCLs can availably reduce the generator rotor oscillating and restrain the transient energy changing, and meanwhile, an extension of the critical clearance time is achieved for the MMPS.
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (8) , 1-7
Study of Modified Flux-Coupling-Type SFCLs For Stability Improvement of a Multi-Machine Power System Based On Energy Function
This paper investigates modified ux-coupling-type superconducting fault current limiters (SFCLs) for enhancing the transient stability of a multi-machine power system (MMPS). The clustering architecture of the MMPS with the modified SFCLs is presented, and the transient energy function (TEF) of the MMPS is established. Through clarifying the potential influence of the modified SFCLs, theoretical analysis signifies that the modified SFCLs can reduce the transient energy accumulation during the fault-feeding period, and increase the transient stability margin of the MMPS. Using MATLAB/Simulink, a benchmark IEEE 9-bus system with the SFCLs is modeled, and the simulation analysis of the generator rotor swing behaviors is carried out. Varying the resistive-inductive parameters and altering the positions of the SFCLs are considered, and the TEF method is applied to gain quantitative effects. The simulation findings in different scenarios testify the correctness of the theoretical analysis. The presence of the SFCLs can availably reduce the generator rotor oscillating and restrain the transient energy changing, and meanwhile, an extension of the critical clearance time is achieved for the MMPS.
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-6
Study on Coordination of Resistive SFCLs and Hybrid-Type Circuit Breakers to Protect a HVDC System With LCC and VSC Stations
Directing at the robustness increase of a high voltage direct current (HVDC) system with line commutated converter (LCC) and voltage source converter (VSC), this paper proposes to coordinate resistive superconducting fault current limiters (SFCLs) and hybrid-type DC circuit breakers (HDCBs) for dealing with the DC line fault. The theoretical modeling of the SFCLs is presented, and the DC fault current characteristics are analyzed. Considering that the fault interruption involves multi-stages, the coordination of the SFCL and the HDCB in the LCC/VSC station is elaborated. Using PSCAD/EMTDC, the simulation model of a 320 kV HVDC system is built. Changing the SFCL size and the HDCB operation delay is simulated, and the performance indexes such as the fault current level, breaking time and dissipated energy are compared. The proposed coordination is verified to be very effective in handling the fault. Especially for the VSC station, it enables to visibly limit the fault current rising, shorten the transient voltage duration, and facilitate a significant decrease in the dissipated energy of the HDCB. For the LCC station, the proposed coordination can serve as a competitive backup to ensure a timely fault breaking. Consequently, the DC line fault is removed more rapidly and reliably.
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-6
Study on Coordination of Resistive SFCLs and Hybrid-Type Circuit Breakers to Protect a HVDC System With LCC and VSC Stations
Directing at the robustness increase of a high voltage direct current (HVDC) system with line commutated converter (LCC) and voltage source converter (VSC), this paper proposes to coordinate resistive superconducting fault current limiters (SFCLs) and hybrid-type DC circuit breakers (HDCBs) for dealing with the DC line fault. The theoretical modeling of the SFCLs is presented, and the DC fault current characteristics are analyzed. Considering that the fault interruption involves multi-stages, the coordination of the SFCL and the HDCB in the LCC/VSC station is elaborated. Using PSCAD/EMTDC, the simulation model of a 320 kV HVDC system is built. Changing the SFCL size and the HDCB operation delay is simulated, and the performance indexes such as the fault current level, breaking time and dissipated energy are compared. The proposed coordination is verified to be very effective in handling the fault. Especially for the VSC station, it enables to visibly limit the fault current rising, shorten the transient voltage duration, and facilitate a significant decrease in the dissipated energy of the HDCB. For the LCC station, the proposed coordination can serve as a competitive backup to ensure a timely fault breaking. Consequently, the DC line fault is removed more rapidly and reliably.
- Open Access
- 9 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1934-1936
Transient overvoltage on overhead metal return lines of ±500 kV MMC‐HVDC grid
The ±500 kV half‐bridge modular multilevel converter‐high‐voltage DC (MMC‐HVDC) grid project with overhead transmission line is under construction in China at present. For MMC‐HVDC grid, only one electrical grounding point is allowed and thus, the metal return lines on the same towers with positive and negative polar lines are necessary. However, current studies mainly focused on the control methods of MMC‐HVDC substation and few studies have been done on the transient overvoltage of overhead transmission line for the MMC‐HVDC project. This study analysed the main transient overvoltage types of metal return lines of ±500 kV half‐bridge MMC‐HVDC grid which transmit electric power by overhead lines and clear the grounding fault by DC breakers. Based on a ±500 kV MMC‐HVDC grid project, the simulation models were built using PSCAD and the possible transient overvoltage types were studied. The results showed that the most serious overvoltage was caused by the DC breaker clearing the grounding fault. Then the insulation coordination design for metal return lines was carried out. The recommended arcing horn clearances at different altitude were given. The research results provided support for the insulation design of the transmission line.
- 9 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1934-1936
Open AccessTransient overvoltage on overhead metal return lines of ±500 kV MMC‐HVDC grid
The ±500 kV half‐bridge modular multilevel converter‐high‐voltage DC (MMC‐HVDC) grid project with overhead transmission line is under construction in China at present. For MMC‐HVDC grid, only one electrical grounding point is allowed and thus, the metal return lines on the same towers with positive and negative polar lines are necessary. However, current studies mainly focused on the control methods of MMC‐HVDC substation and few studies have been done on the transient overvoltage of overhead transmission line for the MMC‐HVDC project. This study analysed the main transient overvoltage types of metal return lines of ±500 kV half‐bridge MMC‐HVDC grid which transmit electric power by overhead lines and clear the grounding fault by DC breakers. Based on a ±500 kV MMC‐HVDC grid project, the simulation models were built using PSCAD and the possible transient overvoltage types were studied. The results showed that the most serious overvoltage was caused by the DC breaker clearing the grounding fault. Then the insulation coordination design for metal return lines was carried out. The recommended arcing horn clearances at different altitude were given. The research results provided support for the insulation design of the transmission line.
- Open Access
Study of Resistive-Type Superconducting Fault Current Limiters for a Hybrid High Voltage Direct Current System
In this paper, a hybrid high voltage direct current transmission system containing a line commutated converter and a voltage source converter is developed. To enhance the robustness of the hybrid transmission system against direct current short-circuit faults, resistive-type superconducting fault current limiters are applied, and the effectiveness of this approach is assessed. Related mathematical models are built, and the theoretical functions of the proposed approach are expounded. According to the transient simulations in MATLAB software, the results demonstrate that: (i) The superconducting fault current limiter at the voltage source converter station enables to very efficiently mitigate the fault transients, and owns an enhanced current-limiting ability for handling the short-line faults. (ii) The superconducting fault current limiter at the line commutated converter station is able to mildly limit the fault current and alleviate the voltage drop, and its working performance has a low sensitivity to the fault location. At the end of the study, a brief scheme design of the resistive-type superconducting fault current limiters is achieved. In conclusion, the application feasibility of the proposed approach is well confirmed.
Open AccessStudy of Resistive-Type Superconducting Fault Current Limiters for a Hybrid High Voltage Direct Current System
In this paper, a hybrid high voltage direct current transmission system containing a line commutated converter and a voltage source converter is developed. To enhance the robustness of the hybrid transmission system against direct current short-circuit faults, resistive-type superconducting fault current limiters are applied, and the effectiveness of this approach is assessed. Related mathematical models are built, and the theoretical functions of the proposed approach are expounded. According to the transient simulations in MATLAB software, the results demonstrate that: (i) The superconducting fault current limiter at the voltage source converter station enables to very efficiently mitigate the fault transients, and owns an enhanced current-limiting ability for handling the short-line faults. (ii) The superconducting fault current limiter at the line commutated converter station is able to mildly limit the fault current and alleviate the voltage drop, and its working performance has a low sensitivity to the fault location. At the end of the study, a brief scheme design of the resistive-type superconducting fault current limiters is achieved. In conclusion, the application feasibility of the proposed approach is well confirmed.
- 14 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-8
Conceptual Design and Evaluation of an HTS Magnet for an SMES Used in Improving Transient Performance of a Grid-Connected PV System
This paper suggests a small-scale superconducting magnetic energy storage (SMES) to enhance the transient behaviors of a 100 kW grid-connected photovoltaic (PV) system, and conducts the conceptual design and performance evaluation. Considering the PV system requirements, the stored energy of the SMES is 90 kJ, and the YBCO tapes are adopted to make a solenoid SMES magnet. Based on the genetic algorithm, the magnet parameters including critical current, tape length, parallel and perpendicular magnetic fields are optimized. Using simulation tools, the effects of the SMES on the PV system are assessed, and the electromagnetic properties, stress and loss of the SMES magnet are analyzed. The results prove that: 1) the SMES improves the fault-ride-through (FRT) capability and realizes an effective protection for the PV system. 2) A relatively large perpendicular magnetic field is found in both ends of the SMES magnet, and the maximum field is induced in the middle of the SMES magnet. 3) The maximum stress of the SMES magnet is acceptable, and the mechanical strength is satisfied. 4) The AC loss is crucial for voltage maintenance performance of the SMES at the fault. Under a short clearance time, the heat accumulation may have a moderate controllability.
- 14 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-8
Conceptual Design and Evaluation of an HTS Magnet for an SMES Used in Improving Transient Performance of a Grid-Connected PV System
This paper suggests a small-scale superconducting magnetic energy storage (SMES) to enhance the transient behaviors of a 100 kW grid-connected photovoltaic (PV) system, and conducts the conceptual design and performance evaluation. Considering the PV system requirements, the stored energy of the SMES is 90 kJ, and the YBCO tapes are adopted to make a solenoid SMES magnet. Based on the genetic algorithm, the magnet parameters including critical current, tape length, parallel and perpendicular magnetic fields are optimized. Using simulation tools, the effects of the SMES on the PV system are assessed, and the electromagnetic properties, stress and loss of the SMES magnet are analyzed. The results prove that: 1) the SMES improves the fault-ride-through (FRT) capability and realizes an effective protection for the PV system. 2) A relatively large perpendicular magnetic field is found in both ends of the SMES magnet, and the maximum field is induced in the middle of the SMES magnet. 3) The maximum stress of the SMES magnet is acceptable, and the mechanical strength is satisfied. 4) The AC loss is crucial for voltage maintenance performance of the SMES at the fault. Under a short clearance time, the heat accumulation may have a moderate controllability.
- Open Access
- 3 December 2017
- Published by Wiley in Advances in Condensed Matter Physics
- Vol. 2017, 1-12
Development of a Voltage Compensation Type Active SFCL and Its Application for Transient Performance Enhancement of a PMSG-Based Wind Turbine System
Considering the rapid development of high temperature superconducting (HTS) materials, superconducting power applications have attracted more and more attention in the power industry, particularly for electrical systems including renewable energy. This paper conducts experimental tests on a voltage compensation type active superconducting fault current limiter (SFCL) prototype and explores the SFCL’s application in a permanent-magnet synchronous generator- (PMSG-) based wind turbine system. The SFCL prototype is composed of a three-phase air-core superconducting transformer and a voltage source converter (VSC) integrated with supercapacitor energy storage. According to the commissioning test and the current-limiting test, the SFCL prototype can automatically suppress the fault current and offer a highly controlled compensation voltage in series with the 132 V electrical test system. To expand the application of the active SFCL in a 10 kW class PMSG-based wind turbine system, digital simulations under different fault cases are performed in MATLAB/Simulink. From the demonstrated simulation results, using the active SFCL can help to maintain the power balance, mitigate the voltage-current fluctuation, and improve the wind energy efficiency. The active SFCL can be regarded as a feasible solution to assist the PMSG-based wind turbine system to achieve low-voltage ride-through (LVRT) operation.
- 3 December 2017
- Published by Wiley in Advances in Condensed Matter Physics
- Vol. 2017, 1-12
Open AccessDevelopment of a Voltage Compensation Type Active SFCL and Its Application for Transient Performance Enhancement of a PMSG-Based Wind Turbine System
Considering the rapid development of high temperature superconducting (HTS) materials, superconducting power applications have attracted more and more attention in the power industry, particularly for electrical systems including renewable energy. This paper conducts experimental tests on a voltage compensation type active superconducting fault current limiter (SFCL) prototype and explores the SFCL’s application in a permanent-magnet synchronous generator- (PMSG-) based wind turbine system. The SFCL prototype is composed of a three-phase air-core superconducting transformer and a voltage source converter (VSC) integrated with supercapacitor energy storage. According to the commissioning test and the current-limiting test, the SFCL prototype can automatically suppress the fault current and offer a highly controlled compensation voltage in series with the 132 V electrical test system. To expand the application of the active SFCL in a 10 kW class PMSG-based wind turbine system, digital simulations under different fault cases are performed in MATLAB/Simulink. From the demonstrated simulation results, using the active SFCL can help to maintain the power balance, mitigate the voltage-current fluctuation, and improve the wind energy efficiency. The active SFCL can be regarded as a feasible solution to assist the PMSG-based wind turbine system to achieve low-voltage ride-through (LVRT) operation.
- Open Access
- 25 October 2017
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 2017, 1-7
Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery
The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC) configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.
- 25 October 2017
- Published by Wiley in International Journal of Rotating Machinery
- Vol. 2017, 1-7
Open AccessOvervoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery
The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC) configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.
- Open Access
- 17 June 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-15
Conceptual design of a high-speed electromagnetic switch for a modified flux-coupling-type SFCL and its application in renewable energy system
The modified flux-coupling-type superconducting fault current (SFCL) is a high-efficient electrical auxiliary device, whose basic function is to suppress the short-circuit current by controlling the magnetic path through a high-speed switch. In this paper, the high-speed switch is based on electromagnetic repulsion mechanism, and its conceptual design is carried out to promote the application of the modified SFCL. Regarding that the switch which is consisting of a mobile copper disc, two fixed opening and closing coils, the computational method for the electromagnetic force is discussed, and also the dynamic mathematical model including circuit equation, magnetic field equation as well as mechanical motion equation is theoretically deduced. According to the mathematical modeling and calculation of characteristic parameters, a feasible design scheme is presented, and the high-speed switch’s response time can be less than 0.5 ms. For that the modified SFCL is equipped with this high-speed switch, the SFCL’s application in a 10 kV micro-grid system with multiple renewable energy sources are assessed in the MATLAB software. The simulations are well able to affirm the SFCL’s performance behaviors.
- 17 June 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-15
Open AccessConceptual design of a high-speed electromagnetic switch for a modified flux-coupling-type SFCL and its application in renewable energy system
The modified flux-coupling-type superconducting fault current (SFCL) is a high-efficient electrical auxiliary device, whose basic function is to suppress the short-circuit current by controlling the magnetic path through a high-speed switch. In this paper, the high-speed switch is based on electromagnetic repulsion mechanism, and its conceptual design is carried out to promote the application of the modified SFCL. Regarding that the switch which is consisting of a mobile copper disc, two fixed opening and closing coils, the computational method for the electromagnetic force is discussed, and also the dynamic mathematical model including circuit equation, magnetic field equation as well as mechanical motion equation is theoretically deduced. According to the mathematical modeling and calculation of characteristic parameters, a feasible design scheme is presented, and the high-speed switch’s response time can be less than 0.5 ms. For that the modified SFCL is equipped with this high-speed switch, the SFCL’s application in a 10 kV micro-grid system with multiple renewable energy sources are assessed in the MATLAB software. The simulations are well able to affirm the SFCL’s performance behaviors.