THTakehito Hananouchi

Takehito Hananouchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takehito Hananouchi has a total of 105 co-authors. Here are the top co-authors by number of shared publications:

  • Nobuhiko Sugano

    Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine SuitaJapan

    12 shared publications
  • Hideki Yoshikawa

    Osaka University Graduate School of Medicine

    10 shared publications
  • Takashi Nishii

    Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan

    8 shared publications
  • Hidenobu Miki

    Department of Orthopaedic Surgery, Osaka National Medical Center OsakaJapan

    6 shared publications
  • Darryl D. D'LIma

    Scripps Health, Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 10666 North Torrey Pines Road, La Jolla, CA 92037, USA

    5 shared publications
  • Nobuo Nakamura

    Department of Orthopaedic Surgery, Kyowakai Hospital OsakaJapan

    5 shared publications

Latest Publications

  • Open Access

    A Pilot Three-Dimensional Evaluation of Acetabular Bony Coverage After Modified Spitzy Shelf Acetabuloplasty

    by Fumito Kobayashi, Takehito Hananouchi, Kenichi Oe, Shohei Sogawa, Tomohisa Nakamura, Takanori Saito

    Modified Spitzy shelf acetabuloplasty is a joint-preserving surgical procedure for acetabular dysplasia that aims to enhance bony coverage of the hip joint. Although prior studies have primarily relied on two-dimensional (2D) radiographic evaluations, comprehensive three-dimensional (3D) assessments remain limited. The purpose of this retrospective study was to evaluate changes quantitatively in acetabular coverage following modified Spitzy shelf acetabuloplasty using 3D models reconstructed from computed tomography (CT) images. We retrospectively analyzed 11 hips in 11 patients who underwent staged bilateral modified Spitzy shelf acetabuloplasty. Preoperative and postoperative CT data were used to construct 3D pelvic models, which were registered using anatomical landmarks. Bone graft dimensions, insertion angle, and placement location were evaluated. Acetabular sector angles (ASA), representing circumferential coverage of the femoral head, were measured at 15° intervals on the functional pelvic plane and the anterior pelvic plane. The mean bone graft dimensions were 26.3 ± 3 mm (anteroposterior length) and 12.7 ± 2.7 mm (mediolateral length), providing coverage of 49.5° ± 9.1°. Postoperative ASA increased significantly from 34.5° to 60° on the functional pelvic plane and from 0° to 45° on the anterior pelvic plane (both p < 0.05). 3D analysis demonstrated that modified Spitzy shelf acetabuloplasty effectively enhanced anterosuperior acetabular bony coverage. Although this is a report of a few cases (11 hips), the above findings highlight the value of 3D evaluation in identifying postoperative changes that may not be detected using conventional 2D assessments. Also, further research analyzing the three-dimensional bone graft model revealed in this study may help inform the development of a more ideal biomimetic approach, not only in terms of shape but also function.

  • Open Access

    Usefulness of Probing Sensor Device for Evaluating Meniscal Suture and Scaffold Implantation

    by Shunsuke Sezaki, Shuhei Otsuki, Takashi Ishitani, Takeru Iwata, Takehito Hananouchi, Yoshinori Okamoto, Hitoshi Wakama, Masashi Neo

    Appropriate suture tension is a key factor in successful meniscal repair. This study aimed to clarify the appropriate value of meniscal stabilization with suture repair based on a probing procedure for healthy porcine menisci and a novel meniscal scaffold. After evaluating the reliability of the probing sensor, meniscal vertical tear and partial meniscectomy models were developed, in which suture repair and meniscal scaffold implantation were performed at suture intervals ranging between 20 and 2.5 mm. The residence forces at each interval were evaluated using a probing sensor. Moreover, a tensile test was conducted to evaluate the displacement and presence or absence of gaps. We found that normal and meniscal scaffolds should be fixed within 5 mm of suture interval. The probing residence forces required were at least 1.0 N for vertical tears and 3.0 N for meniscal scaffolds. These findings may be taken into consideration to reduce suture failure following meniscal tear repair and stabilizing meniscal scaffold fixation.


  • Open Access

    Elastic modulus of cadaveric acetabular labrum correlates with ultrashort echo time (UTE) apparent spin-spin (T2*) and spin-lattice (T1) relaxation times

    by Dina Moazamian, Takehito Hananouchi, Hamidreza Shaterian Mohammadi, Alireza Tayarani, Erik W. Dorthé, Darryl D'LIma, Saeed Jerban

    Introduction: The acetabulum labrum plays a critical role in hip function. Medical imaging techniques for measuring changes in labral properties due to its degeneration may help improve our knowledge of its role in hip osteoarthritis (OA). This study aimed to explore the correlation between the mechanical properties of the acetabulum labrum and ultrashort echo time (UTE) MRI properties.Material and method: Acetabular labrum specimens were dissected from 12 fresh-frozen human cadaveric hip joints (64.6 ± 11.6 years old at the time of death, 7 female). UTE Cones sequences were used to measure apparent spin-spin (T2*) and spin-lattice (T1) relaxation times using a knee coil at 3 T in a clinical MR scanner. The stiffness and the elastic modulus (E) of the specimens were measured before MRI scans using uniaxial tensile tests. Spearman's rank correlation coefficients of Tendons' UTE-T2* and -T1 with their mechanical properties were calculated.Results: The human labrum specimen elastic modulus showed a significant inverse correlation with UTE-T2* (R = −0.66, P < 0.01) and with UTE-T1 (R = −0.56, P = 0.05). The stiffness of the specimens showed significant inverse correlations with UTE-T2* (R = −0.53, P = 0.01) and UTE-T1 (R = −0.63, P = 0.02).Conclusion: This study highlighted the potential of UTE-MRI techniques for the mechanical assessment of the acetabular labrum. UTE-MRI may improve labrum degeneration detection and monitoring, which requires further investigations.

  • Open Access

    Determining the Relationship between Mechanical Properties and Quantitative Magnetic Resonance Imaging of Joint Soft Tissues Using Patient-Specific Templates

    by Takehito Hananouchi, Shinji Satake, Kei Sakao, Hiroshi Katsuda, Nagakazu Shimada, Erik W. Dorthe, Darryl D. D’lima

    To determine whether the mechanical properties of joint soft tissues such as cartilage can be calculated from quantitative magnetic resonance imaging (MRI) data, we investigated whether the mechanical properties of articular cartilage and meniscus scheduled to be resected during arthroplasty are correlated with the T2 relaxation time on quantitative MRI at the same location. Six patients who had undergone knee arthroplasty and seven who had undergone hip arthroplasty were examined. For the knee joint, the articular cartilage and lateral meniscus of the distal lateral condyle of the femur and proximal lateral tibia were examined, while for the hip joint, the articular cartilage above the femoral head was studied. We investigated the relationship between T2 relaxation time by quantitative MRI and stiffness using a hand-made compression tester at 235 locations. The patient-individualized template technique was used to align the two measurement sites. The results showed a negative correlation (from −0.30 to −0.35) in the less severely damaged articular cartilage and meniscus. This indicates that tissue mechanical properties can be calculated from T2 relaxation time, suggesting that quantitative MRI is useful in determining when to start loading after interventional surgery on cartilage tissue and in managing the health of elderly patients.


  • Open Access

    Validation of a Method to Measure the T2 Value from the Color Mapping by Hue Value

    by Takehito Hananouchi, Makishi Nakayama

    Background: Color mapping using quantitative MRI (Magnetic Resonance Imaging) is now being reported in various medical fields to be useful in showing tissue conditions and morphological perspectives. Specifically, T2 mapping as one of the color mapping has been used to describe cartilage conditions in orthopedics. However, for orthopedic physicians in out-patient clinics, the color mapping shows only the colors on the mapping to patients without explaining their numerical values. Methods: To address this issue, our study proposed an approach to measure T2 values based on the hue value converted from Red, Green, Blue information on the processed color map. We evaluated the validity of our method with 25 subjects. Results: Our proposed method showed a good and high correlation coefficient (r = 0.9924, p < 0.0001), and the difference of the T2 values between using a dedicated software on console of MRI scanner and our method was small (its absolute value was approximately 1.5, p = 0.008). Conclusion: Therefore, we consider the proposed method is an alternative approach to show the T2 value when the color mapping are available.

  • Correlation between the elastic modulus of anterior cruciate ligament (ACL) and quantitative ultrashort echo time (UTE) magnetic resonance imaging

    by Saeed Jerban, Takehito Hananouchi, Yajun Ma, Behnam Namiranian, Erik W. Dorthe, Jonathan H. Wong, Niloofar Shojaeiadib, Mei Wu, Jiang Du, Darryl D'Lima, et al.

    Conventional magnetic resonance imaging (MRI) often acquires no signal in anterior cruciate ligament (ACL) due to the short apparent transverse relaxation time of ACL. Ultrashort echo time (UTE) MRI is capable of imaging ACL with high signal which enables quantitative ACL assessment. This study aimed to investigate the correlations of the mechanical and microstructural properties of human ACL specimens with quantitative three‐dimensional UTE Cones (3D‐UTE‐Cones) MRI measures. ACL specimens were harvested from cadaveric knee joints of 13 (50.9 ± 21.1 years old, 11 males and 2 female) donors. Specimens were scanned using a series of quantitative 3D‐UTE‐Cones T2* (UTE‐T2*), T1 (UTE‐T1), Adiabatic T1ρ (UTE‐Adiab‐T1ρ), and magnetization transfer (UTE‐MT) sequences in a wrist coil on a clinical 3T scanner. ACL elastic modulus was measured using a uniaxial tensile mechanical test. Histomorphometry analysis was performed to measure the average fascicle specific surface, fascicle size, and number of cells per unit area. Spearman's rank correlations of UTE‐MRI biomarkers with mechanical and histomorphometry measures were investigated. The elastic modulus of ACL showed significant moderate correlations with UTE‐Adiab‐T1ρ (R = −0.59, p = 0.01), macromolecular fraction from MT modeling (R = 0.54, p = 0.01), magnetization transfer ratio (R = 0.53, p = 0.01), UTE‐T2* (R = −0.53, p = 0.01), and average fascicle specific surface (R = 0.54, p = 0.01). UTE‐MRI showed nonsignificant correlations with histomorphometry measures. UTE‐MRI biomarkers may be useful noninvasive tools for the ACL mechanical assessment.


  • Open Access

    The Resistance Force of the Anterior Cruciate Ligament during Pull Probing Is Related to the Mechanical Property

    by Takehito Hananouchi, Tomoyuki Suzuki, Erik W. Dorthe, Jiang Du, Darryl D. D’lima

    There are various methods for reconstructing the anterior cruciate ligament (ACL) from other muscles or tendons. Initial tension of the reconstructed ACL is one of the key elements affecting postoperative outcomes. However, tension cannot be measured after graft fixation. The only intraoperative assessment is pull probing, which is performed by pulling joint soft tissues with the arthroscopic probe and can be measured quantitatively. Therefore, its value might be used as an alternative value for the mechanical property of the ACL. Using a probing device one author developed to measure the resistance force of soft tissues quantitatively while probing, we measured the resistance force of dissected ACLs and used tensile testing to investigate the correlation between the resistance force and the mechanical property of the ligaments. According to the results, when a certain amount of tension (strain; 16.6%) was applied, its mechanical properties were moderately correlated (r = 0.56 [p = 0.045]) with the probing force. Therefore, the tension of the reconstructed ACL after fixation under real ACL reconstruction surgery can be derived from the value of the probing device.


  • Open Access

    Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips

    by Takehito Hananouchi, Soshi Uchida, Yusuke Hashimoto, Funakoshi Noboru, Stephen K. Aoki

    Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum.


  • Open Access

    A Useful Combination of Quantitative Ultrashort Echo Time MR Imaging and a Probing Device for Biomechanical Evaluation of Articular Cartilage

    by Takehito Hananouchi, Yanjun Chen, Saeed Jerban, Masaru Teramoto, Yajun Ma, Erik W. Dorthe, Eric Y. Chang, Jiang Du, Darryl D. D’lima

    In this study, we combined quantitative ultrashort echo time (UTE) magnetic resonance (MR) imaging and an investigation by a probing device with tri-axial force sensor to seek correlations with mechanical properties of human patellar cartilage for in situ evaluation of biomechanical properties. Cartilage blocks (15 × 20 × 5 mm3) were dissected from the patella of six donors; 5 mm square regions of interest from the cartilage blocks were imaged using UTE-MR imaging sequences (T2* and magnetization transfer ratio (MTR)), and mechanical properties were measured using a micro indentation device. Then, the vertical reaction force on the cartilage surface was measured while push-probing forward 3 mm with the probing device at a 30° tilt to the horizontal plane. The results showed a positive correlation between stiffness/elastic modulus and each predictor variable (UTE-T2* (r = 0.240 and 0.255, respectively, UTE-MTR (r = 0.378 and 0.379, respectively), and probing device force (r = 0.426 and 0.423, respectively). Furthermore, multiple linear regression analysis showed the combination of the three predictors had stronger correlation (adjusted r2 = 0.314 (stiffness), 0.323 (elastic), respectively). Our results demonstrate the potential for these non- and less- invasive methods for in situ evaluation of the mechanical properties of cartilage tissue.


  • A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy

    by Takehito Hananouchi

    Probing in arthroscopic surgery is performed by pulling or pushing the soft tissue, which provides feedback for understanding the condition of the soft tissue. However, the output is only qualitative based on the “surgeon’s feeling”. Herein is described a probing device developed to address this issue by measuring the resistance of soft tissues quantitatively with a tri-axial force sensor. Under both conditions (i.e., pull- and push-probing certain tissues mimicking the acetabular labrum and cartilage), this probing device is found to be useful for measuring some mechanical properties in joints during arthroscopy.