Alan Kuntz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alan Kuntz has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Robert J. Webster
Vanderbilt University
8 shared publications - Ron Alterovitz
University of North Carolina at Chapel Hill
6 shared publications - Margaret Rox
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
5 shared publications - Janine Hoelscher
Clemson University, Clemson, SC, USA
4 shared publications - Maxwell Emerson
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
4 shared publications - Tayfun Efe Ertop
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
4 shared publications
Latest Publications
- Open Access
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec4197
Toward autonomous robotic-assisted and microrobotic surgery
Autonomous robotic-assisted surgery (RAS) has emerged as a promising objective in biomedical technology, further enhanced by miniaturization toward microrobotic-assisted surgery (μ-RAS). This reduction in scale promises minimally invasive, partially or fully automated surgical procedures, with the potential to reduce patient recovery times, lower medical costs, and enable previously unavailable procedural options. This perspective highlights the specific advances in RAS that potentially map to the microscale (μ-RAS), organized across five surgical domains: endovascular, endoluminal, laparoscopic, ophthalmic, and orthopedic. We examine both clinical demands and technological advances in surgical robotics and identify the key innovations required for progress across these surgical fields. Our contribution is distinct in combining the perspectives of both surgical experts and bioengineering innovators, outlining a roadmap for the advancement and eventual integration of autonomous RAS and μ-RAS into mainstream surgical practice.
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec4197
Open AccessToward autonomous robotic-assisted and microrobotic surgery
Autonomous robotic-assisted surgery (RAS) has emerged as a promising objective in biomedical technology, further enhanced by miniaturization toward microrobotic-assisted surgery (μ-RAS). This reduction in scale promises minimally invasive, partially or fully automated surgical procedures, with the potential to reduce patient recovery times, lower medical costs, and enable previously unavailable procedural options. This perspective highlights the specific advances in RAS that potentially map to the microscale (μ-RAS), organized across five surgical domains: endovascular, endoluminal, laparoscopic, ophthalmic, and orthopedic. We examine both clinical demands and technological advances in surgical robotics and identify the key innovations required for progress across these surgical fields. Our contribution is distinct in combining the perspectives of both surgical experts and bioengineering innovators, outlining a roadmap for the advancement and eventual integration of autonomous RAS and μ-RAS into mainstream surgical practice.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- 9 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (104) , eadt1874
Medical needles in the hands of AI: Advancing toward autonomous robotic navigation
Safely and accurately navigating needles percutaneously or endoscopically to sites deep within the body is essential for many medical procedures, from biopsies to localized drug deliveries to tumor ablations. The advent of image guidance decades ago gave physicians information about the patient’s anatomy. We are now entering the era of AI (artificial intelligence) guidance, where AI can automatically analyze images, identify targets and obstacles, compute safe trajectories, and autonomously navigate a needle to a site with unprecedented accuracy and precision. We survey recent advances in the building blocks of AI guidance for medical needle deployment robots (perceiving anatomy, planning motions, perceiving instrument state, and performing motions) and discuss research opportunities to maximize the benefits of AI guidance for patient care.
- 9 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (104) , eadt1874
Medical needles in the hands of AI: Advancing toward autonomous robotic navigation
Safely and accurately navigating needles percutaneously or endoscopically to sites deep within the body is essential for many medical procedures, from biopsies to localized drug deliveries to tumor ablations. The advent of image guidance decades ago gave physicians information about the patient’s anatomy. We are now entering the era of AI (artificial intelligence) guidance, where AI can automatically analyze images, identify targets and obstacles, compute safe trajectories, and autonomously navigate a needle to a site with unprecedented accuracy and precision. We survey recent advances in the building blocks of AI guidance for medical needle deployment robots (perceiving anatomy, planning motions, perceiving instrument state, and performing motions) and discuss research opportunities to maximize the benefits of AI guidance for patient care.
- 3 February 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (01n02)
Uncertainty Aware Forward and Inverse Kinematics for Tendon-Driven Continuum Robots via Mixture Density Networks
Tendon-driven continuum robot kinematic models are frequently computationally expensive, inaccurate due to unmodeled effects, or both. In particular, unmodeled effects produce uncertainties that arise during the robot’s operation that lead to variability in the resulting geometry. We propose a novel solution to these issues through the development of a Gaussian mixture kinematic model. We train a mixture density network to output a Gaussian mixture model representation of the robot geometry given the current tendon displacements. This model computes a probability distribution that is more representative of the true distribution of geometries at a given configuration than a model that outputs a single geometry, while also reducing the computation time. We demonstrate uses of this model through both a trajectory optimization method that explicitly reasons about the workspace uncertainty to minimize the probability of collision and an inverse kinematics method that maximizes the likelihood of occupying a desired geometry.
- 3 February 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (01n02)
Uncertainty Aware Forward and Inverse Kinematics for Tendon-Driven Continuum Robots via Mixture Density Networks
Tendon-driven continuum robot kinematic models are frequently computationally expensive, inaccurate due to unmodeled effects, or both. In particular, unmodeled effects produce uncertainties that arise during the robot’s operation that lead to variability in the resulting geometry. We propose a novel solution to these issues through the development of a Gaussian mixture kinematic model. We train a mixture density network to output a Gaussian mixture model representation of the robot geometry given the current tendon displacements. This model computes a probability distribution that is more representative of the true distribution of geometries at a given configuration than a model that outputs a single geometry, while also reducing the computation time. We demonstrate uses of this model through both a trajectory optimization method that explicitly reasons about the workspace uncertainty to minimize the probability of collision and an inverse kinematics method that maximizes the likelihood of occupying a desired geometry.
- Open Access
- 21 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (1) , 392-403
Encoding Desired Deformation Profiles in Endoscope-Like Soft Robots
Prior models of continuously flexible robots typically assume uniform stiffness, and in this paper we relax this assumption. Geometrically varying stiffness profiles provide additional design freedom to influence the motions and workspaces of continuum robots. These results are timely, because with recent rapid advancements in multimaterial additive manufacturing techniques, it is now straightforward to create more complex stiffness profiles in robots. The key insight of this paper is to project forces and moments applied to the robot onto its center of stiffness (i.e. the Young’s modulus-weighted center of each cross section). We show how the center of stiffness can be thought of as analogous to a “precurved backbone” in a robot with uniform stiffness. This analogy enables a large body of prior work in Cosserat Rod modeling of such robots to be applied directly to those with stiffness variations. We experimentally validate this approach using multimaterial, soft, tendon-actuated robots. Lastly, to illustrate how these results can be used in practice, we investigate how stiffness variation can improve performance in a neurosurgical task.
- 21 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (1) , 392-403
Open AccessEncoding Desired Deformation Profiles in Endoscope-Like Soft Robots
Prior models of continuously flexible robots typically assume uniform stiffness, and in this paper we relax this assumption. Geometrically varying stiffness profiles provide additional design freedom to influence the motions and workspaces of continuum robots. These results are timely, because with recent rapid advancements in multimaterial additive manufacturing techniques, it is now straightforward to create more complex stiffness profiles in robots. The key insight of this paper is to project forces and moments applied to the robot onto its center of stiffness (i.e. the Young’s modulus-weighted center of each cross section). We show how the center of stiffness can be thought of as analogous to a “precurved backbone” in a robot with uniform stiffness. This analogy enables a large body of prior work in Cosserat Rod modeling of such robots to be applied directly to those with stiffness variations. We experimentally validate this approach using multimaterial, soft, tendon-actuated robots. Lastly, to illustrate how these results can be used in practice, we investigate how stiffness variation can improve performance in a neurosurgical task.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 9263-9270
Accounting for Hysteresis in the Forward Kinematics of Nonlinearly-Routed Tendon-Driven Continuum Robots via a Learned Deep Decoder Network
Tendon-driven continuum robots have been gaining popularity in medical applications due to their ability to curve around complex anatomical structures, potentially reducing the invasiveness of surgery. However, accurate modeling is required to plan and control the movements of these flexible robots. Physics-based models have limitations due to unmodeled effects, leading to mismatches between model prediction and actual robot shape. Recently proposed learning-based methods have been shown to overcome some of these limitations but do not account for hysteresis, a significant source of error for these robots. To overcome these challenges, we propose a novel deep decoder neural network that predicts the complete shape of tendon-driven robots using point clouds as the shape representation, conditioned on prior configurations to account for hysteresis. We evaluate our method on a physical tendon-driven robot and show that our network model accurately predicts the robot's shape, significantly outperforming a state-of-the-art physics-based model and a learning-based model that does not account for hysteresis.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 9263-9270
Accounting for Hysteresis in the Forward Kinematics of Nonlinearly-Routed Tendon-Driven Continuum Robots via a Learned Deep Decoder Network
Tendon-driven continuum robots have been gaining popularity in medical applications due to their ability to curve around complex anatomical structures, potentially reducing the invasiveness of surgery. However, accurate modeling is required to plan and control the movements of these flexible robots. Physics-based models have limitations due to unmodeled effects, leading to mismatches between model prediction and actual robot shape. Recently proposed learning-based methods have been shown to overcome some of these limitations but do not account for hysteresis, a significant source of error for these robots. To overcome these challenges, we propose a novel deep decoder neural network that predicts the complete shape of tendon-driven robots using point clouds as the shape representation, conditioned on prior configurations to account for hysteresis. We evaluate our method on a physical tendon-driven robot and show that our network model accurately predicts the robot's shape, significantly outperforming a state-of-the-art physics-based model and a learning-based model that does not account for hysteresis.
- 13 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (82) , eadf7614
Autonomous medical needle steering in vivo
The use of needles to access sites within organs is fundamental to many interventional medical procedures both for diagnosis and treatment. Safely and accurately navigating a needle through living tissue to a target is currently often challenging or infeasible because of the presence of anatomical obstacles, high levels of uncertainty, and natural tissue motion. Medical robots capable of automating needle-based procedures have the potential to overcome these challenges and enable enhanced patient care and safety. However, autonomous navigation of a needle around obstacles to a predefined target in vivo has not been shown. Here, we introduce a medical robot that autonomously navigates a needle through living tissue around anatomical obstacles to a target in vivo. Our system leverages a laser-patterned highly flexible steerable needle capable of maneuvering along curvilinear trajectories. The autonomous robot accounts for anatomical obstacles, uncertainty in tissue/needle interaction, and respiratory motion using replanning, control, and safe insertion time windows. We applied the system to lung biopsy, which is critical for diagnosing lung cancer, the leading cause of cancer-related deaths in the United States. We demonstrated successful performance of our system in multiple in vivo porcine studies achieving targeting errors less than the radius of clinically relevant lung nodules. We also demonstrated that our approach offers greater accuracy compared with a standard manual bronchoscopy technique. Our results show the feasibility and advantage of deploying autonomous steerable needle robots in living tissue and how these systems can extend the current capabilities of physicians to further improve patient care.
- 13 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (82) , eadf7614
Autonomous medical needle steering in vivo
The use of needles to access sites within organs is fundamental to many interventional medical procedures both for diagnosis and treatment. Safely and accurately navigating a needle through living tissue to a target is currently often challenging or infeasible because of the presence of anatomical obstacles, high levels of uncertainty, and natural tissue motion. Medical robots capable of automating needle-based procedures have the potential to overcome these challenges and enable enhanced patient care and safety. However, autonomous navigation of a needle around obstacles to a predefined target in vivo has not been shown. Here, we introduce a medical robot that autonomously navigates a needle through living tissue around anatomical obstacles to a target in vivo. Our system leverages a laser-patterned highly flexible steerable needle capable of maneuvering along curvilinear trajectories. The autonomous robot accounts for anatomical obstacles, uncertainty in tissue/needle interaction, and respiratory motion using replanning, control, and safe insertion time windows. We applied the system to lung biopsy, which is critical for diagnosing lung cancer, the leading cause of cancer-related deaths in the United States. We demonstrated successful performance of our system in multiple in vivo porcine studies achieving targeting errors less than the radius of clinically relevant lung nodules. We also demonstrated that our approach offers greater accuracy compared with a standard manual bronchoscopy technique. Our results show the feasibility and advantage of deploying autonomous steerable needle robots in living tissue and how these systems can extend the current capabilities of physicians to further improve patient care.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3494-3501
Toward Continuum Robot Tentacles for Lung Interventions: Exploring Folding Support Disks
Toward the future goal of creating a lung surgery system featuring multiple tentacle-like robots, we present a new folding concept for continuum robots that enables them to squeeze through openings smaller than the robot's nominal diameter (e.g., the narrow space between adjacent ribs). This is facilitated by making the disks along the robot's backbone foldable.We also demonstrate that such a robot can feature not only straight, but also curved tendon routing paths, thereby achieving a diverse family of conformations. We find that the foldable robot performs comparably, from a kinematic perspective, to an identical non-folding continuum robot at varying deployment lengths. This work paves the way for future applications with a continuum robot that can fold and fit through smaller openings, with the potential to reduce invasiveness during surgical tasks.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3494-3501
Toward Continuum Robot Tentacles for Lung Interventions: Exploring Folding Support Disks
Toward the future goal of creating a lung surgery system featuring multiple tentacle-like robots, we present a new folding concept for continuum robots that enables them to squeeze through openings smaller than the robot's nominal diameter (e.g., the narrow space between adjacent ribs). This is facilitated by making the disks along the robot's backbone foldable.We also demonstrate that such a robot can feature not only straight, but also curved tendon routing paths, thereby achieving a diverse family of conformations. We find that the foldable robot performs comparably, from a kinematic perspective, to an identical non-folding continuum robot at varying deployment lengths. This work paves the way for future applications with a continuum robot that can fold and fit through smaller openings, with the potential to reduce invasiveness during surgical tasks.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 4-17
Screw-Tip Soft Magnetically Steerable Needles
We present a new paradigm in steerable needles comprising flexible tubing with a screw tip and a permanent magnet near the tip. The needle is rotated at its proximal end as the primary mechanism of insertion, rather than being pushed, enabling the screw tip to pull itself through the tissue as it is steered via magnetic torque. Our design enables turns with tighter curvature than previous designs, and it circumvents a well-known problem with existing steerable needles: it is challenging to turn more than 90 degrees without inducing damage. We evaluate our needle via human-in-the-loop robot-assisted magnetic steering in a brain-simulating gel tissue phantom, wherein we achieve a radius of curvature of 29 mm with 210 degrees of turning for a needle with a functional lumen. In a needle without the lumen we achieve a minimum radius of curvature of 10.1 mm. We further evaluate the needle in ex-vivo ovine brain via open-loop steering. We characterize the steerability of the needles as a function of independent parameters. The results demonstrate a needle that promises significantly improved steerability and safety, particularly for use in delicate tissues that create the greatest challenges for existing designs.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 4-17
Screw-Tip Soft Magnetically Steerable Needles
We present a new paradigm in steerable needles comprising flexible tubing with a screw tip and a permanent magnet near the tip. The needle is rotated at its proximal end as the primary mechanism of insertion, rather than being pushed, enabling the screw tip to pull itself through the tissue as it is steered via magnetic torque. Our design enables turns with tighter curvature than previous designs, and it circumvents a well-known problem with existing steerable needles: it is challenging to turn more than 90 degrees without inducing damage. We evaluate our needle via human-in-the-loop robot-assisted magnetic steering in a brain-simulating gel tissue phantom, wherein we achieve a radius of curvature of 29 mm with 210 degrees of turning for a needle with a functional lumen. In a needle without the lumen we achieve a minimum radius of curvature of 10.1 mm. We further evaluate the needle in ex-vivo ovine brain via open-loop steering. We characterize the steerability of the needles as a function of independent parameters. The results demonstrate a needle that promises significantly improved steerability and safety, particularly for use in delicate tissues that create the greatest challenges for existing designs.