Jiahao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jiahao Wu has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Yun-Hui Liu
The Chinese University of Hong Kong
5 shared publications - Fangxun Zhong
School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, China
3 shared publications - Zerui Wang
Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong
3 shared publications - Bo Lu
Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, Suzhou, Jiangsu, China
2 shared publications Dezhao Guo
T Stone Robotics Institute and Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, China
2 shared publicationsIulian Iordachita
LCSR, Johns Hopkins University, Baltimore, MD 21218, USA
2 shared publications
Latest Publications
- 8 August 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 278 (Pt 1) , 134606
Triple synergistic sterilization of Prussian blue nanoparticle-doped chitosan/gelatin packaging film for enhanced food preservation
- 8 August 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 278 (Pt 1) , 134606
Triple synergistic sterilization of Prussian blue nanoparticle-doped chitosan/gelatin packaging film for enhanced food preservation
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 135-145
Steady-Hand Eye Robot 3.0: Optimization and Benchtop Evaluation for Subretinal Injection
Subretinal injection methods and other procedures for treating retinal conditions and diseases (many considered incurable) have been limited in scope due to limited human motor control. This study demonstrates the next generation, cooperatively controlled Steady-Hand Eye Robot (SHER 3.0), a precise and intuitive-to-use robotic platform achieving clinical standards for targeting accuracy and resolution for subretinal injections. The system design and basic kinematics are reported and a deflection model for the incorporated delta stage and validation experiments are presented. This model optimizes the delta stage parameters, maximizing the global conditioning index and minimizing torsional compliance. Five tests measuring accuracy, repeatability, and deflection show the optimized stage design achieves a tip accuracy of $ { < 30} {\mu }\text{m}$ , tip repeatability of $ {9.3} {\mu }\text{m}$ and 0.02°, and deflections between 20–350 $ {\mu }\text{m}$ /N. Future work will use updated control models to refine tip positioning outcomes and will be tested on in vivo animal models.
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 135-145
Steady-Hand Eye Robot 3.0: Optimization and Benchtop Evaluation for Subretinal Injection
Subretinal injection methods and other procedures for treating retinal conditions and diseases (many considered incurable) have been limited in scope due to limited human motor control. This study demonstrates the next generation, cooperatively controlled Steady-Hand Eye Robot (SHER 3.0), a precise and intuitive-to-use robotic platform achieving clinical standards for targeting accuracy and resolution for subretinal injections. The system design and basic kinematics are reported and a deflection model for the incorporated delta stage and validation experiments are presented. This model optimizes the delta stage parameters, maximizing the global conditioning index and minimizing torsional compliance. Five tests measuring accuracy, repeatability, and deflection show the optimized stage design achieves a tip accuracy of $ { < 30} {\mu }\text{m}$ , tip repeatability of $ {9.3} {\mu }\text{m}$ and 0.02°, and deflections between 20–350 $ {\mu }\text{m}$ /N. Future work will use updated control models to refine tip positioning outcomes and will be tested on in vivo animal models.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (7) , 2203-2214
Design, Control, and Experiments of a Novel Robotic Uterine Manipulator With the Motorized 3-DoF Manipulation Rod
To address the issue of declining performance over time with manual uterine manipulation during minimally invasive gynecologic surgery, we propose a novel uterine manipulation robot that offers tireless, stable, and safer manipulation. This proposed robot consists of a 3-DoF remote center of motion (RCM) mechanism and a 3-DoF manipulation rod. The RCM mechanism uses a single-motor bilinear-guided design that allows for a wide range of pitch motion (-50 to 34 degrees) while maintaining a compact structure. The manipulation rod has a tip diameter of only 6 mm, allowing it to accommodate almost any patient's cervix. The 30-degree distal pitch motion and $\pm$ 45-degree distal roll motion of the instrument further improve uterine visualization. The tip of the rod can be opened into a T-shape to minimize damage to the uterus. Laboratory tests have revealed that our device has a highly precise mechanical RCM accuracy of 0.373mm and is capable of handling a maximum load of 500g. Furthermore, through clinical testing, the robot has been proven to offer improved manipulation and visualization of the uterus, making it a valuable addition to the surgical tools available to gynecologists.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (7) , 2203-2214
Design, Control, and Experiments of a Novel Robotic Uterine Manipulator With the Motorized 3-DoF Manipulation Rod
To address the issue of declining performance over time with manual uterine manipulation during minimally invasive gynecologic surgery, we propose a novel uterine manipulation robot that offers tireless, stable, and safer manipulation. This proposed robot consists of a 3-DoF remote center of motion (RCM) mechanism and a 3-DoF manipulation rod. The RCM mechanism uses a single-motor bilinear-guided design that allows for a wide range of pitch motion (-50 to 34 degrees) while maintaining a compact structure. The manipulation rod has a tip diameter of only 6 mm, allowing it to accommodate almost any patient's cervix. The 30-degree distal pitch motion and $\pm$ 45-degree distal roll motion of the instrument further improve uterine visualization. The tip of the rod can be opened into a T-shape to minimize damage to the uterus. Laboratory tests have revealed that our device has a highly precise mechanical RCM accuracy of 0.373mm and is capable of handling a maximum load of 500g. Furthermore, through clinical testing, the robot has been proven to offer improved manipulation and visualization of the uterus, making it a valuable addition to the surgical tools available to gynecologists.
- 8 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (3) , 656-666
Robot-Enabled Uterus Manipulator for Laparoscopic Hysterectomy With Soft RCM Constraints: Design, Control, and Evaluation
Laparoscopic hysterectomy is a common minimally invasive gynecologic surgery in which an assistant is required to manipulate the uterus during the procedure according to the verbal commands of the primary surgeon. However, uterus manipulation is a lengthy and laborious task, where human fatigue may lower operating safety. This paper presents a novel robot-enabled uterus manipulation system that provides accurate, tireless, and direct uterus manipulation. The system consists primarily of a 7-DoF robotic arm tailored for uterus manipulation in laparoscopic hysterectomy. The primary surgeon can directly control the robot using a footswitch pedal to move within the constraint of the Remote Center of Motion (RCM) via software and achieve the desired range of pitch and yaw motion. An additional rotational motion around the instrument axis is provided for twisting the uterus to enhance the exposure of the ligaments and peritoneum for resection. In addition, the robot arm consists of 7 compact modular actuators that provide the target payload for holding the uterus while maintaining a small footprint in a constrained operating environment. To facilitate operation, a passive mobile base is provided for supporting and positioning the robot. A 6-D force sensor is equipped that allows the assistant to quickly guide the robot into the work area and move the robot under RCM constraint using an admittance control approach. The uterus manipulation rod can be easily detached from the robot body by a quick pluggable mechanism for preoperative sterilization. A quick pluggable mechanism was proposed for easy separation and mounting of the uterus manipulation rod from the robot body for preoperative sterilization. Experiments were performed to measure the performance of the modular joints, RCM repeatability, and evaluate the feasibility of the robot in the simulated laparoscopic hysterectomy.
- 8 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (3) , 656-666
Robot-Enabled Uterus Manipulator for Laparoscopic Hysterectomy With Soft RCM Constraints: Design, Control, and Evaluation
Laparoscopic hysterectomy is a common minimally invasive gynecologic surgery in which an assistant is required to manipulate the uterus during the procedure according to the verbal commands of the primary surgeon. However, uterus manipulation is a lengthy and laborious task, where human fatigue may lower operating safety. This paper presents a novel robot-enabled uterus manipulation system that provides accurate, tireless, and direct uterus manipulation. The system consists primarily of a 7-DoF robotic arm tailored for uterus manipulation in laparoscopic hysterectomy. The primary surgeon can directly control the robot using a footswitch pedal to move within the constraint of the Remote Center of Motion (RCM) via software and achieve the desired range of pitch and yaw motion. An additional rotational motion around the instrument axis is provided for twisting the uterus to enhance the exposure of the ligaments and peritoneum for resection. In addition, the robot arm consists of 7 compact modular actuators that provide the target payload for holding the uterus while maintaining a small footprint in a constrained operating environment. To facilitate operation, a passive mobile base is provided for supporting and positioning the robot. A 6-D force sensor is equipped that allows the assistant to quickly guide the robot into the work area and move the robot under RCM constraint using an admittance control approach. The uterus manipulation rod can be easily detached from the robot body by a quick pluggable mechanism for preoperative sterilization. A quick pluggable mechanism was proposed for easy separation and mounting of the uterus manipulation rod from the robot body for preoperative sterilization. Experiments were performed to measure the performance of the modular joints, RCM repeatability, and evaluate the feasibility of the robot in the simulated laparoscopic hysterectomy.
- Open Access
- 27 September 2021
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 308, 01002
Research on the design of small interior space
In such a high population density society as China, especially in developed cities, the real estate market needs a concept of micro-housing. Working people in big cities like Beijing and Shanghai spend very little time at home while working and socializing outside the home every day. High-density population cities need to meet the living needs of as many people as possible in a limited area. If we can solve this problem the demand for houses will decrease and prices will fall. And tiny buildings can also reduce greenhouse gas emissions. (Statistics show that residential, commercial, and industrial buildings account for 40 percent of greenhouse gas emissions.) The ecological benefits of micro buildings extend beyond the house itself. Micro buildings not only increase the density of housing, so that more people have a home, but also shorten the time of transportation. After consulting a large number of literatures, this study hopes to summarize the existing literatures and find the best way for micro buildings to meet the needs of more people in high-density population cities. In this study, conclude some interior design methods or techniques to find out how to improve the quality of small space design. We search and review information in three different fields: indoor thermal comfort, human-based furniture, and interior lighting design. The paper presents some techniques including thermal control equipment and a day-light prediction system. Different human-based furniture is divided into various types, we analyse their advantages and disadvantages, leading to the small interior space to find how can they be used to improve human’s feeling. We discuss the possibility that designers enhance people’s life in a big city by using indoor designing ways.
- 27 September 2021
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 308, 01002
Open AccessResearch on the design of small interior space
In such a high population density society as China, especially in developed cities, the real estate market needs a concept of micro-housing. Working people in big cities like Beijing and Shanghai spend very little time at home while working and socializing outside the home every day. High-density population cities need to meet the living needs of as many people as possible in a limited area. If we can solve this problem the demand for houses will decrease and prices will fall. And tiny buildings can also reduce greenhouse gas emissions. (Statistics show that residential, commercial, and industrial buildings account for 40 percent of greenhouse gas emissions.) The ecological benefits of micro buildings extend beyond the house itself. Micro buildings not only increase the density of housing, so that more people have a home, but also shorten the time of transportation. After consulting a large number of literatures, this study hopes to summarize the existing literatures and find the best way for micro buildings to meet the needs of more people in high-density population cities. In this study, conclude some interior design methods or techniques to find out how to improve the quality of small space design. We search and review information in three different fields: indoor thermal comfort, human-based furniture, and interior lighting design. The paper presents some techniques including thermal control equipment and a day-light prediction system. Different human-based furniture is divided into various types, we analyse their advantages and disadvantages, leading to the small interior space to find how can they be used to improve human’s feeling. We discuss the possibility that designers enhance people’s life in a big city by using indoor designing ways.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 7750-7757
Spotlight-Based 3D Instrument Guidance for Autonomous Task in Robot-Assisted Retinal Surgery
Retinal surgery is known to be a complicated and challenging task for an ophthalmologist even for retina specialists. Image guided robot-assisted intervention is among the novel and promising solutions that may enhance human capabilities during microsurgery. In this letter, a novel method is proposed for 3D navigation of a microsurgical instrument based on the projection of a spotlight during robot-assisted retinal surgery. To test the feasibility and effectiveness of the proposed method, a vessel tracking task in a phantom with a Remote Center of Motion (RCM) constraint is performed by the Steady-Hand Eye Robot (SHER). The results are compared to manual tracking, cooperative control tracking with the SHER and spotlight-based automatic tracking with SHER. The reported results are that the spotlight-based automatic tracking with SHER can reach an average tracking error of 0.013 mm and keeping distance error of 0.1 mm from the desired range demonstrating a significant improvement compared to manual or cooperative control methods alone.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 7750-7757
Spotlight-Based 3D Instrument Guidance for Autonomous Task in Robot-Assisted Retinal Surgery
Retinal surgery is known to be a complicated and challenging task for an ophthalmologist even for retina specialists. Image guided robot-assisted intervention is among the novel and promising solutions that may enhance human capabilities during microsurgery. In this letter, a novel method is proposed for 3D navigation of a microsurgical instrument based on the projection of a spotlight during robot-assisted retinal surgery. To test the feasibility and effectiveness of the proposed method, a vessel tracking task in a phantom with a Remote Center of Motion (RCM) constraint is performed by the Steady-Hand Eye Robot (SHER). The results are compared to manual tracking, cooperative control tracking with the SHER and spotlight-based automatic tracking with SHER. The reported results are that the spotlight-based automatic tracking with SHER can reach an average tracking error of 0.013 mm and keeping distance error of 0.1 mm from the desired range demonstrating a significant improvement compared to manual or cooperative control methods alone.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 34, 333-337
Exploration on the Development of Engineering Practice Teaching Ability for Young Teachers in Professional Education
The self-developed mechanical processing quasi-field provides the campus engineering environment and the professional experimental teaching practice platform for young teachers in professional education. With the help of a series of professional curriculum supporting training, experiment, practical operation and design links, the practical teaching ability of young teachers can be improved from engineering task design, engineering practice operation to engineering problem solving through the synchronous interaction between classroom theory and engineering practice application. It provides teacher quality assurance for the transportation of high-quality engineering and scientific talents in high-end manufacturing field.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 34, 333-337
Exploration on the Development of Engineering Practice Teaching Ability for Young Teachers in Professional Education
The self-developed mechanical processing quasi-field provides the campus engineering environment and the professional experimental teaching practice platform for young teachers in professional education. With the help of a series of professional curriculum supporting training, experiment, practical operation and design links, the practical teaching ability of young teachers can be improved from engineering task design, engineering practice operation to engineering problem solving through the synchronous interaction between classroom theory and engineering practice application. It provides teacher quality assurance for the transportation of high-quality engineering and scientific talents in high-end manufacturing field.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 8-14
Force-based Safe Vein Cannulation in Robot-assisted Retinal Surgery: A Preliminary Study
Retinal vein cannulation (RVC) is a potential treatment for retinal vein occlusion (RVO). Manual surgery has limitations in RVC due to extremely small vessels and instruments involved, as well as the presence of physiological hand tremor. Robot-assisted retinal surgery may be a better approach to smooth and accurate instrument manipulation during this procedure. Motion of the retina and cornea related to heartbeat may be associated with unexpected forces between the tool and eyeball. In this paper, we propose a force-based control strategy to automatically compensate for the movement of the retina maintaining the tip force and sclera force in a predetermined small range. A dual force-sensing tool is used to monitor the tip force, sclera force and tool insertion depth, which will be used to derive a desired joint velocity for the robot via a modified admittance controller. Then the tool is manipulated to compensate for the movement of the retina as well as reduce the tip force and sclera force. Quantitative experiments are conducted to verify the efficacy of the control strategy and a user study is also conducted by a retinal surgeon to demonstrate the advantages of our automatic compensation approach.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 8-14
Force-based Safe Vein Cannulation in Robot-assisted Retinal Surgery: A Preliminary Study
Retinal vein cannulation (RVC) is a potential treatment for retinal vein occlusion (RVO). Manual surgery has limitations in RVC due to extremely small vessels and instruments involved, as well as the presence of physiological hand tremor. Robot-assisted retinal surgery may be a better approach to smooth and accurate instrument manipulation during this procedure. Motion of the retina and cornea related to heartbeat may be associated with unexpected forces between the tool and eyeball. In this paper, we propose a force-based control strategy to automatically compensate for the movement of the retina maintaining the tip force and sclera force in a predetermined small range. A dual force-sensing tool is used to monitor the tip force, sclera force and tool insertion depth, which will be used to derive a desired joint velocity for the robot via a modified admittance controller. Then the tool is manipulated to compensate for the movement of the retina as well as reduce the tip force and sclera force. Quantitative experiments are conducted to verify the efficacy of the control strategy and a user study is also conducted by a retinal surgeon to demonstrate the advantages of our automatic compensation approach.
- 24 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 3105-3111
An Optimized Tilt Mechanism for a New Steady-Hand Eye Robot
Robot-assisted vitreoretinal surgery can filter surgeons' hand tremors and provide safe, accurate tool manipulation. In this paper, we report the design, optimization, and evaluation of a novel tilt mechanism for a new Steady-Hand Eye Robot (SHER). The new tilt mechanism features a four-bar linkage design and has a compact structure. Its kinematic configuration is optimized to minimize the required linear range of motion (LRM) for implementing a virtual remote center-of-motion (V-RCM) while tilting a surgical tool. Due to the different optimization constraints for the robots at the left and right sides of the human head, two configurations of this tilt mechanism are proposed. Experimental results show that the optimized tilt mechanism requires a significantly smaller LRM (e.g. 5.08 mm along Z direction and 8.77 mm along Y direction for left side robot) as compared to the slider-crank tilt mechanism used in the previous SHER (32.39 mm along Z direction and 21.10 mm along Y direction). The feasibility of the proposed tilt mechanism is verified in a mock bilateral robot-assisted vitreoretinal surgery. The ergonomically acceptable robot postures needed to access the surgical field is also determined.
- 24 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 3105-3111
An Optimized Tilt Mechanism for a New Steady-Hand Eye Robot
Robot-assisted vitreoretinal surgery can filter surgeons' hand tremors and provide safe, accurate tool manipulation. In this paper, we report the design, optimization, and evaluation of a novel tilt mechanism for a new Steady-Hand Eye Robot (SHER). The new tilt mechanism features a four-bar linkage design and has a compact structure. Its kinematic configuration is optimized to minimize the required linear range of motion (LRM) for implementing a virtual remote center-of-motion (V-RCM) while tilting a surgical tool. Due to the different optimization constraints for the robots at the left and right sides of the human head, two configurations of this tilt mechanism are proposed. Experimental results show that the optimized tilt mechanism requires a significantly smaller LRM (e.g. 5.08 mm along Z direction and 8.77 mm along Y direction for left side robot) as compared to the slider-crank tilt mechanism used in the previous SHER (32.39 mm along Z direction and 21.10 mm along Y direction). The feasibility of the proposed tilt mechanism is verified in a mock bilateral robot-assisted vitreoretinal surgery. The ergonomically acceptable robot postures needed to access the surgical field is also determined.
- 18 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (4) , 2045-2053
Design and Validation of a Novel Leaf Spring-Based Variable Stiffness Joint With Reconfigurability
Compliant joints can provide safer physical human-robot interaction (pHRI). To effectively balance the response bandwidth and output impedance, variable stiffness joints have been studied by many researchers. Leaf spring based variable stiffness joint (LSVSJ) has the advantages of easy construction and large stiffness range. This paper presents the design and validation of a novel leaf spring based variable stiffness joint with reconfigurability (LSJR). Compared with most of the existing LSVSJ, this novel LSJR ensures the contact performance between the roller and the leaf spring, uses a novel effective length adjustment mechanism, and provides multiple stiffness ranges. The compliance of the LSJR is generated by leaf springs. The spring is bent by two rows of rollers integrated on an adjustable slider, where the distance between the rollers can be changed so as to achieve a tighter contact between the roller and the spring. The effective length of the spring can be adjusted by changing the position of the slider locating at the intersection between a straight rail and an arcuate rail. A reconfigurable number of leaf springs provide six different stiffness ranges (e.g., 138.55~396.08 Nm/rad for single leaf spring, and 384.56~1222.60 Nm/rad for a combination of three leaf springs). By integrating a high-resolution angle sensor, the LSJR can also measure the joint torque. Moreover, the hollow shaft structure of the joint is beneficial for passing cables through it. Experiments were performed to measure the stiffness of the LSJR under different configurations, validate its efficacy in unexpected collisions, and investigate its potential to be a one-degree-of-freedom (DOF) torque sensor.
- 18 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (4) , 2045-2053
Design and Validation of a Novel Leaf Spring-Based Variable Stiffness Joint With Reconfigurability
Compliant joints can provide safer physical human-robot interaction (pHRI). To effectively balance the response bandwidth and output impedance, variable stiffness joints have been studied by many researchers. Leaf spring based variable stiffness joint (LSVSJ) has the advantages of easy construction and large stiffness range. This paper presents the design and validation of a novel leaf spring based variable stiffness joint with reconfigurability (LSJR). Compared with most of the existing LSVSJ, this novel LSJR ensures the contact performance between the roller and the leaf spring, uses a novel effective length adjustment mechanism, and provides multiple stiffness ranges. The compliance of the LSJR is generated by leaf springs. The spring is bent by two rows of rollers integrated on an adjustable slider, where the distance between the rollers can be changed so as to achieve a tighter contact between the roller and the spring. The effective length of the spring can be adjusted by changing the position of the slider locating at the intersection between a straight rail and an arcuate rail. A reconfigurable number of leaf springs provide six different stiffness ranges (e.g., 138.55~396.08 Nm/rad for single leaf spring, and 384.56~1222.60 Nm/rad for a combination of three leaf springs). By integrating a high-resolution angle sensor, the LSJR can also measure the joint torque. Moreover, the hollow shaft structure of the joint is beneficial for passing cables through it. Experiments were performed to measure the stiffness of the LSJR under different configurations, validate its efficacy in unexpected collisions, and investigate its potential to be a one-degree-of-freedom (DOF) torque sensor.