Luz Universidad de A Coruña González Doniz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luz Universidad de A Coruña González Doniz has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ana Lista Paz
Faculty of Physiotherapy, The University of A Coruña, A Coruña, Spain
1 shared publication - Antonio Souto-Gestal
Department of Physiotherapy, Medicine and Biomedical Sciences, University of A Coruña, 15006 A Coruña, Spain
1 shared publication - Cristina Jácome
CINTESIS@RISE, MEDCIDS, Faculty of Medicine of University of Porto, Porto, Portugal
1 shared publication - Ramón Universidad de A Coruña Fernández Cervantes
Psychosocial Intervention and Functional Reabilitation Research Group. Physiotherapy Department, Faculty of Physiotherapy, University of A Coruña, Campus de Oza, A Coruña, 15006, Spain
1 shared publication Ramón Universidad de A Coruña González Cabanach
1 shared publication- Sergio Sancho Marín
Faculty of Physiotherapy, The University of A Coruña, A Coruña, ESP
1 shared publication
Latest Publications
- Open Access
- 29 October 2021
- Published by Springer Nature in Cureus
- Vol. 13 (10)
Comparison of Two Protocols for the Assessment of Maximal Respiratory Pressures: Spanish Society of Pulmonology and Thoracic Surgery Versus American Thoracic Society/European Respiratory Society
The measurement of maximal respiratory pressures (MRPs) is commonly used to assess respiratory muscle strength. However, in Spain, there is no consensus on which is the most adequate measurement protocol, as the Spanish Society of Pneumology and Thoracic Surgery (SEPAR) protocol differs from the one endorsed by the American Thoracic Society/European Respiratory Society (ATS/ERS). This study compared the absolute and predictive values of maximal expiratory and inspiratory pressures (MEP and MIP) in healthy adults obtained with the two protocols. A cross-sectional study with a sample of healthy adults was conducted. Lung function and MRPs were assessed. MEP and MIP were measured using a digital manometer according to the SEPAR and ATS/ERS. Protocols were applied in random order by the same trained physiotherapist. The comfort experienced with each protocol was assessed through a short questionnaire. Paired t-tests were used to compare the results from both protocols. A total of 31 subjects (mean age 35.7±12.4 years; 14 females; FEV1=108.3±10.5%; FVC=103.7±10%) were included. There was a significant difference between MRPs favouring the SEPAR protocol, with the mean difference being 34.9±28.1 cmH2O (p˂0.001) for MEP and 8±11.6 cmH2O (p=0.001) for MIP. ATS/ERS protocol was, however, considered more comfortable than SEPAR (p<0.005). This study shows that, in healthy adults, higher MRPs are obtained using the SEPAR protocol. Yet, the ATS/ERS protocol is experienced as more comfortable. Future studies are needed to analyse the application of both protocols in other populations and their associated comfort.
- 29 October 2021
- Published by Springer Nature in Cureus
- Vol. 13 (10)
Open AccessComparison of Two Protocols for the Assessment of Maximal Respiratory Pressures: Spanish Society of Pulmonology and Thoracic Surgery Versus American Thoracic Society/European Respiratory Society
The measurement of maximal respiratory pressures (MRPs) is commonly used to assess respiratory muscle strength. However, in Spain, there is no consensus on which is the most adequate measurement protocol, as the Spanish Society of Pneumology and Thoracic Surgery (SEPAR) protocol differs from the one endorsed by the American Thoracic Society/European Respiratory Society (ATS/ERS). This study compared the absolute and predictive values of maximal expiratory and inspiratory pressures (MEP and MIP) in healthy adults obtained with the two protocols. A cross-sectional study with a sample of healthy adults was conducted. Lung function and MRPs were assessed. MEP and MIP were measured using a digital manometer according to the SEPAR and ATS/ERS. Protocols were applied in random order by the same trained physiotherapist. The comfort experienced with each protocol was assessed through a short questionnaire. Paired t-tests were used to compare the results from both protocols. A total of 31 subjects (mean age 35.7±12.4 years; 14 females; FEV1=108.3±10.5%; FVC=103.7±10%) were included. There was a significant difference between MRPs favouring the SEPAR protocol, with the mean difference being 34.9±28.1 cmH2O (p˂0.001) for MEP and 8±11.6 cmH2O (p=0.001) for MIP. ATS/ERS protocol was, however, considered more comfortable than SEPAR (p<0.005). This study shows that, in healthy adults, higher MRPs are obtained using the SEPAR protocol. Yet, the ATS/ERS protocol is experienced as more comfortable. Future studies are needed to analyse the application of both protocols in other populations and their associated comfort.
- Open Access
- 1 April 2016
- Published by Universidad de Navarra in Estudios sobre Educación
- Vol. 30, 95-113
Self-esteem as a Protective Factor against Burnout in Students of Physiotherapy
La autoestima como variable protectora del burnout en estudiantes de fisioterapia
- 1 April 2016
- Published by Universidad de Navarra in Estudios sobre Educación
- Vol. 30, 95-113
Open AccessSelf-esteem as a Protective Factor against Burnout in Students of Physiotherapy
La autoestima como variable protectora del burnout en estudiantes de fisioterapia