Yanliang He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yanliang He has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jianyi Xue
Hefei University of Technology
4 shared publications - Anbang Sun
School of Electrical Engineering, Xi'an Jiaotong University 1 , Xi'an 710049
2 shared publications - Guanjun Zhang
Xi’an Jiaotong University
2 shared publications - Lijian Ding
Department of Respiratory and Critical Care Medicine, The Affiliated Yangming Hospital of Ningbo University (Yuyao People’s Hospital), Ningbo University
2 shared publications Xing Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University , Xi’an 710049, China
2 shared publicationsAn Bang Sun
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publication
Latest Publications
- Open Access
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 91767-91776
Positive Streamer Initiation in SF6/CO2 Based on Zener’s Field Ionization
In this study, experiments were performed to measure the inception and breakdown voltages of SF 6 /CO 2 mixed gases with varying mixing ratios at two different pressures (1 and 2 bar). Using the preliminary data obtained from the experiments, a 3D particle model was used to investigate positive streamer initiation in SF 6 /CO 2 with field ionization. Field ionization using Zener’s model was assumed to be similar to the electron detachment in air. The experimental results showed that at P = 1 bar, the discharge inception voltage increased for CO 2 concentrations lower than 50% and decreased for CO 2 concentrations higher than 50%. The inception voltage of 80%CO 2 /20%SF 6 was close to the inception voltage of pure SF 6 . A similar trend of the inception and breakdown voltages was observed at P = 2 bar. The simulation results show the evolution of the thin filaments of the streamer into three distinct stages. The streamer morphology was similar irrespective of the type and concentration of the mixed gas. Other parameters such as the electric field, electron density, and streamer length increased with increasing CO 2 concentration in SF 6 at both pressures. Zener’s field ionization could be considered a primary ionization mechanism for SF 6 /CO 2 in the case of very high non-uniform electric fields; however, finding the experimental validation of Zener’s field ionization for electronegative gases is still a challenging task.
- 25 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 91767-91776
Open AccessPositive Streamer Initiation in SF6/CO2 Based on Zener’s Field Ionization
In this study, experiments were performed to measure the inception and breakdown voltages of SF 6 /CO 2 mixed gases with varying mixing ratios at two different pressures (1 and 2 bar). Using the preliminary data obtained from the experiments, a 3D particle model was used to investigate positive streamer initiation in SF 6 /CO 2 with field ionization. Field ionization using Zener’s model was assumed to be similar to the electron detachment in air. The experimental results showed that at P = 1 bar, the discharge inception voltage increased for CO 2 concentrations lower than 50% and decreased for CO 2 concentrations higher than 50%. The inception voltage of 80%CO 2 /20%SF 6 was close to the inception voltage of pure SF 6 . A similar trend of the inception and breakdown voltages was observed at P = 2 bar. The simulation results show the evolution of the thin filaments of the streamer into three distinct stages. The streamer morphology was similar irrespective of the type and concentration of the mixed gas. Other parameters such as the electric field, electron density, and streamer length increased with increasing CO 2 concentration in SF 6 at both pressures. Zener’s field ionization could be considered a primary ionization mechanism for SF 6 /CO 2 in the case of very high non-uniform electric fields; however, finding the experimental validation of Zener’s field ionization for electronegative gases is still a challenging task.
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (5) , 2224-2231
Collaborative Optimization of Conductivity and Permittivity on GIL Spacer Surface for Electric Field Regulation Under DC Superimposed Impulse Voltages
The gas-solid interface electric field distortion is an essential factor leading to surface insulation failure. This study proposes the conductivity and permittivity-graded coating layer (ε/γ-layer) method, aiming at regulating surface charge and electric field distribution on GIL spacers under DC/ DC superimposed impulse voltages. The iteration optimization algorithm is developed to obtain the optimal conductivity and permittivity distribution of the ε/γ-layer. The surface charge and electric field behavior on GIL spacers with the ε/γ-layer are investigated through the numerical simulation approach. The polarity of the accumulated surface charges reverses on both the convex and concave sides as the conductivity of the ε/γ-layer increases under DC voltages, indicating the dominant mechanism changing from the bulk conductivity model to the surface conductivity model. The electric field distribution is also improved with the ε/γ-layer at the optimal permittivity and conductivity distribution. Compared with the raw spacer, the maximum electric field strength with ε/γ-layer is reduced by about 31.97% under DC, 20.56% under DC superimposed positive impulse (DC+Po.Im), 42.68% under DC superimposed negative impulse (DC+Ne.Im) on the convex surface, about 64.22% under DC, 21.37% under DC+Po.Im, 36.46% under DC+Ne.Im on the concave surface, correspondingly. It is hoped that the results of this study could spark off novel ideas for the optimal design of DC GIL spacers.
- 8 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (5) , 2224-2231
Collaborative Optimization of Conductivity and Permittivity on GIL Spacer Surface for Electric Field Regulation Under DC Superimposed Impulse Voltages
The gas-solid interface electric field distortion is an essential factor leading to surface insulation failure. This study proposes the conductivity and permittivity-graded coating layer (ε/γ-layer) method, aiming at regulating surface charge and electric field distribution on GIL spacers under DC/ DC superimposed impulse voltages. The iteration optimization algorithm is developed to obtain the optimal conductivity and permittivity distribution of the ε/γ-layer. The surface charge and electric field behavior on GIL spacers with the ε/γ-layer are investigated through the numerical simulation approach. The polarity of the accumulated surface charges reverses on both the convex and concave sides as the conductivity of the ε/γ-layer increases under DC voltages, indicating the dominant mechanism changing from the bulk conductivity model to the surface conductivity model. The electric field distribution is also improved with the ε/γ-layer at the optimal permittivity and conductivity distribution. Compared with the raw spacer, the maximum electric field strength with ε/γ-layer is reduced by about 31.97% under DC, 20.56% under DC superimposed positive impulse (DC+Po.Im), 42.68% under DC superimposed negative impulse (DC+Ne.Im) on the convex surface, about 64.22% under DC, 21.37% under DC+Po.Im, 36.46% under DC+Ne.Im on the concave surface, correspondingly. It is hoped that the results of this study could spark off novel ideas for the optimal design of DC GIL spacers.
- Open Access
- 1 August 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (8) , 085303
Effect of trace SF6 on negative corona characteristics in SF6/N2 gas mixtures under DC voltages
Corona discharge will affect the performance of insulating gas, threatening the safe and reliable operation of gas-insulated power equipment. In this paper, we investigate the negative corona characteristics in SF6/N2 gas mixtures with trace SF6 [φ(SF6) ≤ 1%] under DC voltages. With decreasing SF6 content, two types of the discharge–stage transition process as a function of mean current are observed. One process is from the Townsend stage, through the pulse stage, to the breakdown stage; the other one presents a normal-glow stage between the pulse stage and the breakdown stage. The threshold of SF6 content which can change the discharge–stage transition process in SF6/N2 gas mixtures is between 0.1% and 0.15%. The lower limit of positive-ion flux in the normal-glow stage is 6–7 orders of magnitude higher than the upper limit of positive-ion flux in the Townsend stage. The variation in pulse characteristic parameters, including pulse–time parameters and pulse amplitude, with increasing SF6 content is investigated. The pulse–time parameters show a trend of decreasing first and then saturation with increasing SF6 content, while the pulse amplitude shows a slightly increasing trend. Moreover, the “return stroke” phenomenon of negative corona in SF6/N2 gas mixtures is observed through discharge light emission images. The “return stroke” phenomenon does not necessarily occur in the normal-glow stage, resulting from competition between the position of the negative-ion cloud and the negative-ion flux.
- 1 August 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (8) , 085303
Open AccessEffect of trace SF6 on negative corona characteristics in SF6/N2 gas mixtures under DC voltages
Corona discharge will affect the performance of insulating gas, threatening the safe and reliable operation of gas-insulated power equipment. In this paper, we investigate the negative corona characteristics in SF6/N2 gas mixtures with trace SF6 [φ(SF6) ≤ 1%] under DC voltages. With decreasing SF6 content, two types of the discharge–stage transition process as a function of mean current are observed. One process is from the Townsend stage, through the pulse stage, to the breakdown stage; the other one presents a normal-glow stage between the pulse stage and the breakdown stage. The threshold of SF6 content which can change the discharge–stage transition process in SF6/N2 gas mixtures is between 0.1% and 0.15%. The lower limit of positive-ion flux in the normal-glow stage is 6–7 orders of magnitude higher than the upper limit of positive-ion flux in the Townsend stage. The variation in pulse characteristic parameters, including pulse–time parameters and pulse amplitude, with increasing SF6 content is investigated. The pulse–time parameters show a trend of decreasing first and then saturation with increasing SF6 content, while the pulse amplitude shows a slightly increasing trend. Moreover, the “return stroke” phenomenon of negative corona in SF6/N2 gas mixtures is observed through discharge light emission images. The “return stroke” phenomenon does not necessarily occur in the normal-glow stage, resulting from competition between the position of the negative-ion cloud and the negative-ion flux.
- Open Access
- 1 May 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (5) , 055027
Experimental study on pulse characteristics of negative corona discharge in SF6/N2 gas mixtures under DC voltages
Corona discharge, an inevitable phenomenon, may lead to insulation degradation, threatening the safe and reliable operation of gas-insulated power equipment. The pulse stage is a complex but usual discharge process in corona discharge. In this paper, we investigate the pulse characteristics of negative corona discharge in a needle-to-plane electrode configuration in SF6/N2 gas mixtures under DC voltages. With an increase in mean current, a stage transition phenomenon from the Townsend stage through the pulse stage to the breakdown stage is observed. The variation in pulse amplitude and pulse time characteristics at the pulse stage is analyzed. In addition, the effects of gas pressure, gap spacing, and N2 content on onset voltage and pulse characteristic parameters, including pulse time parameters and the pulse repetition rate, at the pulse stage are presented. The results show that the current pulses mainly exhibit an irregular distribution of small amplitude. The pulse time parameters are not affected by gas pressure, gap spacing, or N2 content at pressures higher than 0.1 MPa. The pulse repetition rate decreases with an increase in gas pressure and N2 content but is only weakly affected by gap spacing, ranging from 1 kHz to dozens of kHz.
- 1 May 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (5) , 055027
Open AccessExperimental study on pulse characteristics of negative corona discharge in SF6/N2 gas mixtures under DC voltages
Corona discharge, an inevitable phenomenon, may lead to insulation degradation, threatening the safe and reliable operation of gas-insulated power equipment. The pulse stage is a complex but usual discharge process in corona discharge. In this paper, we investigate the pulse characteristics of negative corona discharge in a needle-to-plane electrode configuration in SF6/N2 gas mixtures under DC voltages. With an increase in mean current, a stage transition phenomenon from the Townsend stage through the pulse stage to the breakdown stage is observed. The variation in pulse amplitude and pulse time characteristics at the pulse stage is analyzed. In addition, the effects of gas pressure, gap spacing, and N2 content on onset voltage and pulse characteristic parameters, including pulse time parameters and the pulse repetition rate, at the pulse stage are presented. The results show that the current pulses mainly exhibit an irregular distribution of small amplitude. The pulse time parameters are not affected by gas pressure, gap spacing, or N2 content at pressures higher than 0.1 MPa. The pulse repetition rate decreases with an increase in gas pressure and N2 content but is only weakly affected by gap spacing, ranging from 1 kHz to dozens of kHz.