Paola Andrea Niño-Suárez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paola Andrea Niño-Suárez has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Oscar Fernando Avilés Sánchez
Universidad Militar Nueva Granada
5 shared publications - Luis Armando Flores-Herrera
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Unidad Azcapotzalco, Mexico City 02250, Mexico
4 shared publications - Edgar Alfredo Portilla-Flores
Centro de Innovación y Desarrollo Tecnológico en Cómputo, Instituto Politécnico Nacional, Avenida Instituto Politécnico Nacional 2580, Barrio la Laguna Ticomán, Gustavo A Madero, Mexico City 07340, Mexico
3 shared publications - Eduardo Vega-Alvarado
Group of Research and Innovation in Mechatronics (GRIM), Centro de Innovación y Desarrollo Tecnológico en Cómputo (CIDETEC), Instituto Politécnico Nacional, Mexico City 07700, Mexico
3 shared publications - Emmanuel Zenén Rivera Blas
Departamento de Ingeniería en Sistemas Computacionales, Tecnológico Nacional de México, Campus Instituto Tecnológico Superior de Alvarado Veracruz, La Trocha, Alvarado 95270, Veracruz, México
3 shared publications - Leonel German Corona Ramirez
Unidad Profesional Interdisciplinaria en Ingeniería y Tecnologías Avanzadas, Instituto Politécnico Nacional, Mexico City 07340, Mexico
3 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (6) , 96
Review: Artificial Intelligence Applied to Physiological Signals to Support Clinical Diagnosis
Analyzing physiological signals with artificial intelligence (AI) has become a strategic tool for clinical diagnosis, event prediction, risk stratification, monitoring, and functional analysis, among other tasks. However, the growing use of AI in healthcare raises a key concern: models can achieve high performance on specific tasks, but this does not necessarily translate into clinical utility, generalizability, or integration into real-world care settings. This work presents a structured review of recent and selected foundational research published between 2018 and 2026, aimed at characterizing AI applications to physiological signals. It considers the analyzed signals, AI families, implemented techniques, reported metrics, the degree of unimodal or multimodal integration, and gaps in validation, interpretability, and reproducibility. The final database included 83 evidence entries, organized as an evidence matrix with information on AI family, architecture, reported performance, and the physiological or functional signal used. This review identifies single-source approaches, multimodal predictive integration, and multimodal representation learning, highlighting their different methodological characteristics and potential clinical applications. The main contribution of this work is to show that the potential clinical contribution of AI applied to physiological signals depends not only on algorithmic performance but also on its integration with robust validation, traceability, interpretability, physiological coherence, and relevance to the clinical phenomenon.
- 23 October 2026
- Published by MDPI AG in BioMedInformatics
- Vol. 6 (6) , 96
Open AccessReview: Artificial Intelligence Applied to Physiological Signals to Support Clinical Diagnosis
Analyzing physiological signals with artificial intelligence (AI) has become a strategic tool for clinical diagnosis, event prediction, risk stratification, monitoring, and functional analysis, among other tasks. However, the growing use of AI in healthcare raises a key concern: models can achieve high performance on specific tasks, but this does not necessarily translate into clinical utility, generalizability, or integration into real-world care settings. This work presents a structured review of recent and selected foundational research published between 2018 and 2026, aimed at characterizing AI applications to physiological signals. It considers the analyzed signals, AI families, implemented techniques, reported metrics, the degree of unimodal or multimodal integration, and gaps in validation, interpretability, and reproducibility. The final database included 83 evidence entries, organized as an evidence matrix with information on AI family, architecture, reported performance, and the physiological or functional signal used. This review identifies single-source approaches, multimodal predictive integration, and multimodal representation learning, highlighting their different methodological characteristics and potential clinical applications. The main contribution of this work is to show that the potential clinical contribution of AI applied to physiological signals depends not only on algorithmic performance but also on its integration with robust validation, traceability, interpretability, physiological coherence, and relevance to the clinical phenomenon.
- Open Access
- 30 September 2026
- Published by Universidad Militar Nueva Granada
- p. 1-270
Memorias del Quinto Congreso Internacional en Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura AMDM 2025
Las Memorias del Quinto Congreso Internacional en Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura (AMDM 2025) reúnen una selección de trabajos presentados durante el encuentro celebrado en Bogotá del 4 al 6 de noviembre de 2025. El congreso tuvo como propósito divulgar avances científicos y tecnológicos, promover el intercambio académico y abordar tendencias emergentes, retos de investigación y necesidades de la industria en los campos de la mecatrónica, el diseño y la manufactura. La publicación se estructura en siete áreas temáticas: materiales, robótica, biomecatrónica y bioingeniería, mecánica, energía, computación y realidad virtual, y mecatrónica y control. Los trabajos incluyen investigaciones experimentales, desarrollos computacionales, modelación y simulación, diseño y validación de dispositivos, automatización, manufactura avanzada y aplicaciones de tecnologías como inteligencia artificial, gemelos digitales, visión por computador, robótica, manufactura aditiva y realidad virtual. En conjunto, las memorias ofrecen un panorama de soluciones y desarrollos orientados tanto al avance del conocimiento como a aplicaciones industriales, biomédicas, energéticas y educativas. Los artículos incluidos fueron sometidos a un proceso de revisión por pares coordinado por el comité científico y revisores especializados.
- 30 September 2026
- Published by Universidad Militar Nueva Granada
- p. 1-270
Open AccessMemorias del Quinto Congreso Internacional en Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura AMDM 2025
Las Memorias del Quinto Congreso Internacional en Tecnologías Avanzadas de Mecatrónica, Diseño y Manufactura (AMDM 2025) reúnen una selección de trabajos presentados durante el encuentro celebrado en Bogotá del 4 al 6 de noviembre de 2025. El congreso tuvo como propósito divulgar avances científicos y tecnológicos, promover el intercambio académico y abordar tendencias emergentes, retos de investigación y necesidades de la industria en los campos de la mecatrónica, el diseño y la manufactura. La publicación se estructura en siete áreas temáticas: materiales, robótica, biomecatrónica y bioingeniería, mecánica, energía, computación y realidad virtual, y mecatrónica y control. Los trabajos incluyen investigaciones experimentales, desarrollos computacionales, modelación y simulación, diseño y validación de dispositivos, automatización, manufactura avanzada y aplicaciones de tecnologías como inteligencia artificial, gemelos digitales, visión por computador, robótica, manufactura aditiva y realidad virtual. En conjunto, las memorias ofrecen un panorama de soluciones y desarrollos orientados tanto al avance del conocimiento como a aplicaciones industriales, biomédicas, energéticas y educativas. Los artículos incluidos fueron sometidos a un proceso de revisión por pares coordinado por el comité científico y revisores especializados.
- 21 June 2026
- Published by Springer Nature
- p. 146-161
Multimodal Intelligent System for the Diagnosis of Human Gait Pathologies
- 21 June 2026
- Published by Springer Nature
- p. 146-161
Multimodal Intelligent System for the Diagnosis of Human Gait Pathologies
- Open Access
- 20 March 2026
- Published by Universidad Autonoma del Estado de Hidalgo in Pädi Boletín Científico de Ciencias Básicas e Ingenierías del ICBI
- Vol. 14, 223-230
Identificación de un robot suave usando operadores de Koopman
La identificación de modelos dinámicos en robótica suave continúa siendo un desafío debido a su naturaleza no lineal y a sus infinitos grados de libertad. En este trabajo se propone un enfoque basado en los operadores de Koopman para obtener una representación lineal de un actuador neumático suave tipo PneuNet con una deformación unidireccional. Este método se basa en técnicas de levantamiento de datos, adaptado para sistemas con entradas. Se implementa una plataforma experimental que integra un sistema neumático regulado, sensores de presión y un actuador equipado con un láser que proyecta su movimiento sobre una superficie. Las coordenadas del haz de luz, capturadas mediante una cámara RealSense, se utilizan como salidas del sistema, mientras que la presión suministrada constituye la entrada. El modelo lineal identificado mediante el operador de Koopman logra reproducir adecuadamente la dinámica entrada-salida del sistema, utilizando datos reales de los experimentos.
- 20 March 2026
- Published by Universidad Autonoma del Estado de Hidalgo in Pädi Boletín Científico de Ciencias Básicas e Ingenierías del ICBI
- Vol. 14, 223-230
Open AccessIdentificación de un robot suave usando operadores de Koopman
La identificación de modelos dinámicos en robótica suave continúa siendo un desafío debido a su naturaleza no lineal y a sus infinitos grados de libertad. En este trabajo se propone un enfoque basado en los operadores de Koopman para obtener una representación lineal de un actuador neumático suave tipo PneuNet con una deformación unidireccional. Este método se basa en técnicas de levantamiento de datos, adaptado para sistemas con entradas. Se implementa una plataforma experimental que integra un sistema neumático regulado, sensores de presión y un actuador equipado con un láser que proyecta su movimiento sobre una superficie. Las coordenadas del haz de luz, capturadas mediante una cámara RealSense, se utilizan como salidas del sistema, mientras que la presión suministrada constituye la entrada. El modelo lineal identificado mediante el operador de Koopman logra reproducir adecuadamente la dinámica entrada-salida del sistema, utilizando datos reales de los experimentos.
- Open Access
- 9 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12976
Toward Embedded Multi-Level Classification of 12-Lead ECG Signal Quality Using Spectrograms and CNNs
This study presents an open and replicable methodology for multi-lead ECG signal quality assessment (SQA), implemented on a 12-lead embedded acquisition platform. Signal quality is a critical software component for diagnostic reliability and compliance with international standards such as IEC 60601-2-27 (clinical ECG monitors), IEC 60601-2-47 (ambulatory ECG systems), and IEC 62304 (software life cycle for medical devices) which define the essential engineering requirements and functional performance for medical devices. Unlike proprietary SQA algorithms embedded in closed commercial systems such as Philips DXL™, the proposed method provides a transparent and auditable framework that enables independent validation and supports adaptation for research and clinical prototyping. Our approach combines convolutional neural networks (CNNs) with FFT-derived spectrograms to perform four-level signal quality classification (High, Medium, Low, and Unidentifiable), achieving up to 95.67% accuracy on the test set, confirming the robustness of the CNN-based spectrogram classification model. The algorithm has been validated on a custom controlled dataset generated using the Fluke PS420™ hardware simulator, enabling controlled replication of signal artifacts for software-level evaluation. Designed for execution on resource-constrained embedded platforms, the system integrates real-time preprocessing and wireless transmission, demonstrating its feasibility for deployment in mobile or decentralized ECG monitoring solutions. These results establish a software validation proof-of-concept that goes beyond algorithmic performance, addressing regulatory expectations such as those outlined in FDA’s Good Machine Learning Practice (GMLP). While clinical validation remains pending, this work contributes a standards-aligned methodology to democratize advanced SQA functionality and support future regulatory-compliant development of embedded ECG system.
- 9 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12976
Open AccessToward Embedded Multi-Level Classification of 12-Lead ECG Signal Quality Using Spectrograms and CNNs
This study presents an open and replicable methodology for multi-lead ECG signal quality assessment (SQA), implemented on a 12-lead embedded acquisition platform. Signal quality is a critical software component for diagnostic reliability and compliance with international standards such as IEC 60601-2-27 (clinical ECG monitors), IEC 60601-2-47 (ambulatory ECG systems), and IEC 62304 (software life cycle for medical devices) which define the essential engineering requirements and functional performance for medical devices. Unlike proprietary SQA algorithms embedded in closed commercial systems such as Philips DXL™, the proposed method provides a transparent and auditable framework that enables independent validation and supports adaptation for research and clinical prototyping. Our approach combines convolutional neural networks (CNNs) with FFT-derived spectrograms to perform four-level signal quality classification (High, Medium, Low, and Unidentifiable), achieving up to 95.67% accuracy on the test set, confirming the robustness of the CNN-based spectrogram classification model. The algorithm has been validated on a custom controlled dataset generated using the Fluke PS420™ hardware simulator, enabling controlled replication of signal artifacts for software-level evaluation. Designed for execution on resource-constrained embedded platforms, the system integrates real-time preprocessing and wireless transmission, demonstrating its feasibility for deployment in mobile or decentralized ECG monitoring solutions. These results establish a software validation proof-of-concept that goes beyond algorithmic performance, addressing regulatory expectations such as those outlined in FDA’s Good Machine Learning Practice (GMLP). While clinical validation remains pending, this work contributes a standards-aligned methodology to democratize advanced SQA functionality and support future regulatory-compliant development of embedded ECG system.
- Open Access
Stress Analysis and Operational Limits of an SLA-Printed Soft Antagonistic Actuator Using a Yeoh-Calibrated Finite Element Model
Soft robotics has emerged as a promising approach for safe human–machine interaction, adaptive manipulation, and bioinspired motion, yet its progress relies on accurate material characterization and structural analysis of actuators. This study presents the mechanical behavior and stress analysis of a stereolithography-printed pneumatic actuator with antagonistic architecture, fabricated using Elastic 50A resin V2. Uniaxial tensile tests were performed according to ASTM D412 to derive material parameters, which were fitted to hyperelastic constitutive models. The Yeoh model was identified as the most accurate and implemented in finite element simulations to predict actuator deformation under multiple pressurization modes. Results revealed critical stress zones and established operational pressure limits of 110–130 kPa, beyond which the material approaches its tensile strength. Experimental testing with a controlled pneumatic system validated the numerical predictions, confirming both bending and multidirectional actuation as well as structural failure thresholds. The integration of material characterization, numerical modeling, and experimental validation provides a robust workflow for the design of SLA-fabricated antagonistic actuators. These findings highlight the advantages of combining digital fabrication with antagonistic actuation and material modeling to expand the understanding of soft robots’ behavior.
Open AccessStress Analysis and Operational Limits of an SLA-Printed Soft Antagonistic Actuator Using a Yeoh-Calibrated Finite Element Model
Soft robotics has emerged as a promising approach for safe human–machine interaction, adaptive manipulation, and bioinspired motion, yet its progress relies on accurate material characterization and structural analysis of actuators. This study presents the mechanical behavior and stress analysis of a stereolithography-printed pneumatic actuator with antagonistic architecture, fabricated using Elastic 50A resin V2. Uniaxial tensile tests were performed according to ASTM D412 to derive material parameters, which were fitted to hyperelastic constitutive models. The Yeoh model was identified as the most accurate and implemented in finite element simulations to predict actuator deformation under multiple pressurization modes. Results revealed critical stress zones and established operational pressure limits of 110–130 kPa, beyond which the material approaches its tensile strength. Experimental testing with a controlled pneumatic system validated the numerical predictions, confirming both bending and multidirectional actuation as well as structural failure thresholds. The integration of material characterization, numerical modeling, and experimental validation provides a robust workflow for the design of SLA-fabricated antagonistic actuators. These findings highlight the advantages of combining digital fabrication with antagonistic actuation and material modeling to expand the understanding of soft robots’ behavior.
- Open Access
Development of a Compliant Pediatric Upper-Limb Training Robot Using Series Elastic Actuators
Series elastic actuators (SEAs) represent a key technological solution to enhance safety, performance, and adaptability in robotic devices for physical training. Their ability to decouple the rigid actuator’s mechanical impedance from the load, combined with passive absorption of external disturbances, makes them particularly suitable for pediatric applications. In children aged 2 to 5 years—where motor control is still developing and movements can be unpredictable or unstructured—SEAs provide a compliant mechanical response that ensures user protection and enables safe physical interaction. This study explores the role of SEAs as a central component for imparting compliance and backdrivability in robotic systems designed for upper-limb training. A dynamic model is proposed, incorporating interaction with the user’s limb, along with a computed torque control strategy featuring integral action. The system’s performance is validated through simulations and experimental tests, demonstrating stable trajectory tracking, disturbance absorption, and effective impedance decoupling. The results support the use of SEAs as a foundational technology for developing safe adaptive robotic solutions in pediatric contexts capable of responding flexibly to user variability and promoting secure interaction in early motor development environments.
Open AccessDevelopment of a Compliant Pediatric Upper-Limb Training Robot Using Series Elastic Actuators
Series elastic actuators (SEAs) represent a key technological solution to enhance safety, performance, and adaptability in robotic devices for physical training. Their ability to decouple the rigid actuator’s mechanical impedance from the load, combined with passive absorption of external disturbances, makes them particularly suitable for pediatric applications. In children aged 2 to 5 years—where motor control is still developing and movements can be unpredictable or unstructured—SEAs provide a compliant mechanical response that ensures user protection and enables safe physical interaction. This study explores the role of SEAs as a central component for imparting compliance and backdrivability in robotic systems designed for upper-limb training. A dynamic model is proposed, incorporating interaction with the user’s limb, along with a computed torque control strategy featuring integral action. The system’s performance is validated through simulations and experimental tests, demonstrating stable trajectory tracking, disturbance absorption, and effective impedance decoupling. The results support the use of SEAs as a foundational technology for developing safe adaptive robotic solutions in pediatric contexts capable of responding flexibly to user variability and promoting secure interaction in early motor development environments.
- Open Access
- 10 July 2025
- Published by Universitat Politecnica de Valencia in Revista Iberoamericana de Automática e Informática Industrial
- Vol. 22 (4) , 276-287
Desarrollo y control de un dispositivo robótico rehabilitador de dedos
Enfermedades como el reumatismo pueden limitar la movilidad de los dedos, impidiendo a las personas afectadas realizar sus actividades diarias adecuadamente y requiriendo rehabilitación motora. Este trabajo presenta un dispositivo de terapia activa para mejorar dicha movilidad mediante trayectorias personalizadas, adaptadas a la morfología y rigidez de cada dedo (excepto el pulgar). A diferencia de los exoesqueletos, que no se ajustan bien a dedos desalineados ni consideran variaciones individuales, este diseño tipo efector final sostiene únicamente la yema del dedo, permitiendo movimientos tridimensionales específicos. La variabilidad anatómica y los distintos niveles de rigidez derivados de traumatismos justifican un enfoque personalizado, en el que tanto la fuerza aplicada como la trayectoria varían según cada usuario. Un sistema de control basado en lógica difusa permite calcular el par adecuado para guiar el movimiento del dedo durante la terapia, contribuyendo a una rehabilitación más segura, eficaz y ajustada a las condiciones de cada individuo.
- 10 July 2025
- Published by Universitat Politecnica de Valencia in Revista Iberoamericana de Automática e Informática Industrial
- Vol. 22 (4) , 276-287
Open AccessDesarrollo y control de un dispositivo robótico rehabilitador de dedos
Enfermedades como el reumatismo pueden limitar la movilidad de los dedos, impidiendo a las personas afectadas realizar sus actividades diarias adecuadamente y requiriendo rehabilitación motora. Este trabajo presenta un dispositivo de terapia activa para mejorar dicha movilidad mediante trayectorias personalizadas, adaptadas a la morfología y rigidez de cada dedo (excepto el pulgar). A diferencia de los exoesqueletos, que no se ajustan bien a dedos desalineados ni consideran variaciones individuales, este diseño tipo efector final sostiene únicamente la yema del dedo, permitiendo movimientos tridimensionales específicos. La variabilidad anatómica y los distintos niveles de rigidez derivados de traumatismos justifican un enfoque personalizado, en el que tanto la fuerza aplicada como la trayectoria varían según cada usuario. Un sistema de control basado en lógica difusa permite calcular el par adecuado para guiar el movimiento del dedo durante la terapia, contribuyendo a una rehabilitación más segura, eficaz y ajustada a las condiciones de cada individuo.
- Open Access
A Comprehensive Analysis of Power Electromobility: Challenges from a PESTLE Perspective
This study analyses aspects related to the electromobility transition. Emerging technologies have enabled the production and commercialisation of electric vehicles to reduce polluting emissions. However, significant obstacles are present in this global transition. The analysis identifies that public policies play a crucial role in the development of electromobility, and emphasises how new business models in electromobility are emerging to satisfy changing customer demands. Concerns related to raw materials extraction, battery disposal, and vehicle-to-grid (V2G) integration are also important to consider. The relationship between technologically advanced countries and raw material-producing nations must balance socioeconomic, historical, labour, and ecological factors. In order to have a standard reference, this study considers for the analysis the political, economic, social, technological, environmental, and legal factors (PESTLE). An analysis of future scenarios considering pessimistic and optimistic trends revealed that, compared with the actual trends, important actions must be taken to develop electromobility not only from the technological aspect. These results provide a comprehensive analysis of electromobility sustainability and its importance for multidisciplinary stakeholders related to the actual challenges towards electromobility, the electric network capabilities, and the importance of creating new jobs and products based on a circular and sustainable economy.
Open AccessA Comprehensive Analysis of Power Electromobility: Challenges from a PESTLE Perspective
This study analyses aspects related to the electromobility transition. Emerging technologies have enabled the production and commercialisation of electric vehicles to reduce polluting emissions. However, significant obstacles are present in this global transition. The analysis identifies that public policies play a crucial role in the development of electromobility, and emphasises how new business models in electromobility are emerging to satisfy changing customer demands. Concerns related to raw materials extraction, battery disposal, and vehicle-to-grid (V2G) integration are also important to consider. The relationship between technologically advanced countries and raw material-producing nations must balance socioeconomic, historical, labour, and ecological factors. In order to have a standard reference, this study considers for the analysis the political, economic, social, technological, environmental, and legal factors (PESTLE). An analysis of future scenarios considering pessimistic and optimistic trends revealed that, compared with the actual trends, important actions must be taken to develop electromobility not only from the technological aspect. These results provide a comprehensive analysis of electromobility sustainability and its importance for multidisciplinary stakeholders related to the actual challenges towards electromobility, the electric network capabilities, and the importance of creating new jobs and products based on a circular and sustainable economy.
- 30 April 2025
- Published by Springer Nature
- p. 16-24
Validation Study: Portable Prototype vs. Commercial System for Plantar Pressure Measurements
- 30 April 2025
- Published by Springer Nature
- p. 16-24
Validation Study: Portable Prototype vs. Commercial System for Plantar Pressure Measurements