Wen-Ying Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wen-Ying Zhou has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Mai Lu
Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University
6 shared publications- Mai Lu
Key Laboratory of Opto-electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Lanzhou 730070, China
6 shared publications - Yanwen Hu
School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, People’s Republic of China
6 shared publications Tingrong Zhang
School of Automation and Electrical Engineering, Lanzhou Jiaotong University 1 , Lanzhou 730070
4 shared publicationsJin-Jing Xu
Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University
3 shared publications- Tingrong Zhang
School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, People’s Republic of China
3 shared publications
Latest Publications
- 11 November 2026
- Published by IOP Publishing in Physica Scripta
Experimental research on characteristics of magnetic coupling resonance wireless power transfer system based on non-uniform low-frequency electromagnetic metamaterials
Low-frequency electromagnetic metamaterials (LFEMTM) can effectively improve the transfer efficiency of magnetic coupling resonance wireless power transfer (MCRWPT) systems. But it is difficult to accurately describe the electromagnetic characteristics of LFEMTM due to simulation and inversion errors encountered in practice. To address this issue, the paper proposes a 3×3 non-uniform LFEMTM array to enhance the transfer efficiency of a 6.78 MHz MCRWPT system. Differentiated electromagnetic response characteristics are constructed by adjusting the capacitance values of unit cells at different positions of the LFEMTM, and the optimal capacitance combination is obtained via experimental study. The experimental results demonstrate that the transfer efficiency of the system can be increased from 53.75% to 58.80% with the optimal non-uniform LFEMTM array, compared with the uniform array. Lateral offset experiments of the receiving coil reveal that the non-uniform array maintains a positive efficiency gain within the entire offset range. Its high-efficiency operating window (transfer efficiency > 55%) spans −80 mm to +60 mm, outperforming the uniform array significantly. The research outcomes are conducive to further enhancing the transfer efficiency of MCRWPT systems.
- 11 November 2026
- Published by IOP Publishing in Physica Scripta
Experimental research on characteristics of magnetic coupling resonance wireless power transfer system based on non-uniform low-frequency electromagnetic metamaterials
Low-frequency electromagnetic metamaterials (LFEMTM) can effectively improve the transfer efficiency of magnetic coupling resonance wireless power transfer (MCRWPT) systems. But it is difficult to accurately describe the electromagnetic characteristics of LFEMTM due to simulation and inversion errors encountered in practice. To address this issue, the paper proposes a 3×3 non-uniform LFEMTM array to enhance the transfer efficiency of a 6.78 MHz MCRWPT system. Differentiated electromagnetic response characteristics are constructed by adjusting the capacitance values of unit cells at different positions of the LFEMTM, and the optimal capacitance combination is obtained via experimental study. The experimental results demonstrate that the transfer efficiency of the system can be increased from 53.75% to 58.80% with the optimal non-uniform LFEMTM array, compared with the uniform array. Lateral offset experiments of the receiving coil reveal that the non-uniform array maintains a positive efficiency gain within the entire offset range. Its high-efficiency operating window (transfer efficiency > 55%) spans −80 mm to +60 mm, outperforming the uniform array significantly. The research outcomes are conducive to further enhancing the transfer efficiency of MCRWPT systems.
- Open Access
- 3 September 2026
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 14, 1893518
Compact metasurface track-side PIS antenna-based occupational electromagnetic exposure research of inspectors in the metro tunnel
Introduction: With the advancement of Smart Urban Rail construction, the electromagnetic environment has become increasingly complex inside metro tunnels. Track-side inspectors may experience occupational radio-frequency (RF) exposure when conducting professional inspections in such a closed electromagnetic environment. Methods: In order to analyze the occupational electromagnetic exposure dose absorbed by the track-side inspectors,and explore a method to reduce the influence of RF electromagnetic radiation. We propose a compact metasurface track-side passenger information system (PIS) antenna at first, and verify its good radiation performance. Then we compare the electromagnetic exposure metrics in the track-side inspectors human model when they are exposed to the conventional track-side PIS antenna and the proposed track-side PIS antenna at 5.8 GHz. Results: The simulation results show that, the peak local specific absorption rate (SAR) is reduced by at least 39.83% in the trunk, skull, brain, heart, liver, and testes after the antenna is miniaturized by 53%. Discussion: The findings indicate that the proposed track-side PIS antenna can reduce the external radiation energy, thereby reducing its impact on the surrounding environment. This research provides a theoretical analysis for occupational RF exposure safety of track-side inspectors and offers a dosimetry reference for antenna design in metro tunnel communication systems.
- 3 September 2026
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 14, 1893518
Open AccessCompact metasurface track-side PIS antenna-based occupational electromagnetic exposure research of inspectors in the metro tunnel
Introduction: With the advancement of Smart Urban Rail construction, the electromagnetic environment has become increasingly complex inside metro tunnels. Track-side inspectors may experience occupational radio-frequency (RF) exposure when conducting professional inspections in such a closed electromagnetic environment. Methods: In order to analyze the occupational electromagnetic exposure dose absorbed by the track-side inspectors,and explore a method to reduce the influence of RF electromagnetic radiation. We propose a compact metasurface track-side passenger information system (PIS) antenna at first, and verify its good radiation performance. Then we compare the electromagnetic exposure metrics in the track-side inspectors human model when they are exposed to the conventional track-side PIS antenna and the proposed track-side PIS antenna at 5.8 GHz. Results: The simulation results show that, the peak local specific absorption rate (SAR) is reduced by at least 39.83% in the trunk, skull, brain, heart, liver, and testes after the antenna is miniaturized by 53%. Discussion: The findings indicate that the proposed track-side PIS antenna can reduce the external radiation energy, thereby reducing its impact on the surrounding environment. This research provides a theoretical analysis for occupational RF exposure safety of track-side inspectors and offers a dosimetry reference for antenna design in metro tunnel communication systems.
- 20 July 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (29) , 295508
Design of low-power magnetically coupled resonant wireless power transfer system based on frequency adjustable electromagnetic metamaterials slab
A major limitation of traditional low frequency electromagnetic metamaterials (LFEMTM) is their inability to achieve real-time operating frequency adjustment without modifying structural parameters. This paper proposes a frequency-adjustable LFEMTM to adjust the properties in real time of the low-power magnetically coupled resonant wireless power transfer (MCR-WPT) system. The proposed LFEMTM consists of a 2 × 2 EMTM array integrated with a variable capacitor array (VCA). A maximum power point tracking algorithm is employed to regulate the VCA capacitance in real-time, aiming to minimize the power loss of the MCR-WPT system and enhance system robustness in dynamic application scenarios. Experimental results demonstrate that varying the control voltage from 0 to 3 V enables flexible tuning of the LFEMTM operating frequency across 6.4–7.0 MHz. The experimental results also demonstrate a significant enhancement in MCR-WPT transmission efficiency, rising from 12.78% to 26.53% through dynamic adjustment of the control voltage from 0 V to 2 V. Furthermore, the system exhibits marked performance gains under various misalignment conditions between the transmitting (Tx) and receiving (Rx). The findings provide valuable insights for advancing the design and practical deployment of frequency adjustable LFEMTM array in MCR-WPT applications.
- 20 July 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (29) , 295508
Design of low-power magnetically coupled resonant wireless power transfer system based on frequency adjustable electromagnetic metamaterials slab
A major limitation of traditional low frequency electromagnetic metamaterials (LFEMTM) is their inability to achieve real-time operating frequency adjustment without modifying structural parameters. This paper proposes a frequency-adjustable LFEMTM to adjust the properties in real time of the low-power magnetically coupled resonant wireless power transfer (MCR-WPT) system. The proposed LFEMTM consists of a 2 × 2 EMTM array integrated with a variable capacitor array (VCA). A maximum power point tracking algorithm is employed to regulate the VCA capacitance in real-time, aiming to minimize the power loss of the MCR-WPT system and enhance system robustness in dynamic application scenarios. Experimental results demonstrate that varying the control voltage from 0 to 3 V enables flexible tuning of the LFEMTM operating frequency across 6.4–7.0 MHz. The experimental results also demonstrate a significant enhancement in MCR-WPT transmission efficiency, rising from 12.78% to 26.53% through dynamic adjustment of the control voltage from 0 V to 2 V. Furthermore, the system exhibits marked performance gains under various misalignment conditions between the transmitting (Tx) and receiving (Rx). The findings provide valuable insights for advancing the design and practical deployment of frequency adjustable LFEMTM array in MCR-WPT applications.
- 25 May 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (4) , e70055
Gender Differentiation Based Mobile Terminal Electromagnetic Exposure Safety Analysis and Corresponding Antenna Miniaturized‐Based Protective Measures
The rapid development of 5 G technology raises concerns about near‐field electromagnetic exposure from mobile terminals, especially its potential risks to reproductive and vital organs. However, gender‐based differences in tissue dielectric properties and their impact on exposure are often overlooked. This study has two main objectives: to analyze the influence of gender differences on near‐field electromagnetic exposure, with a particular focus on key tissues, by calculating gender‐specific dielectric properties of different organ tissues; and to propose antenna miniaturization as an active electromagnetic protective measure for reducing specific absorption rate (SAR). This study employs finite element modeling to construct male and female human models, incorporating reproductive systems and key organs, to evaluate SAR before and after the miniaturization of a MIMO mobile terminal antenna at 2.6 GHz and 3.5 GHz. The results show that SAR values in male tissues, particularly in reproductive organs, are significantly higher than in female counterparts. Antenna miniaturization effectively reduces peak SAR by over 30% in multiple tissues, demonstrating its role as an active electromagnetic protective measure. This work highlights gender differences in electromagnetic exposure and confirms the feasibility of antenna miniaturization for improving mobile terminal safety design.
- 25 May 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (4) , e70055
Gender Differentiation Based Mobile Terminal Electromagnetic Exposure Safety Analysis and Corresponding Antenna Miniaturized‐Based Protective Measures
The rapid development of 5 G technology raises concerns about near‐field electromagnetic exposure from mobile terminals, especially its potential risks to reproductive and vital organs. However, gender‐based differences in tissue dielectric properties and their impact on exposure are often overlooked. This study has two main objectives: to analyze the influence of gender differences on near‐field electromagnetic exposure, with a particular focus on key tissues, by calculating gender‐specific dielectric properties of different organ tissues; and to propose antenna miniaturization as an active electromagnetic protective measure for reducing specific absorption rate (SAR). This study employs finite element modeling to construct male and female human models, incorporating reproductive systems and key organs, to evaluate SAR before and after the miniaturization of a MIMO mobile terminal antenna at 2.6 GHz and 3.5 GHz. The results show that SAR values in male tissues, particularly in reproductive organs, are significantly higher than in female counterparts. Antenna miniaturization effectively reduces peak SAR by over 30% in multiple tissues, demonstrating its role as an active electromagnetic protective measure. This work highlights gender differences in electromagnetic exposure and confirms the feasibility of antenna miniaturization for improving mobile terminal safety design.
- Open Access
- 13 March 2026
- Published by MDPI AG in Preprints.org
Dosimetric Assessment of Multi-Frequency Smartwatch Electromagnetic Exposure on Children’s Sensitive Organs
To assess the electromagnetic effect on the children’s sensitive organs when they using the smartwatches, this study analyzes the electromagnetic dose absorbed by the children, especially calculate the combind electromagnetic exposure, We propose a multi-frequency smartwatch antenna (GPS L1, LTE FDD band1, 2.4G Wi-Fi/Bluetooth) and construct a 6-year-old human model including ten tissues from three sensitive organs (brain, eyes, heart). The Specific Absorption Rate (SAR) distributions are simulated under speaking and listening postures at different frequencies using CST Studio Suite. Furthermore, the SAR distributions under multi-frequency combined electromagnetic exposure are evaluated to investigate the superposition effects of electromagnetic fields. The results show that, when the child uses the smartwatch for 4G communication in the listening posture, the maximum local SAR reaches 1.683 W/kg, which is nearly half of the ICNIRP exposure limit. Electromagnetic radiation in the child’s brain is mainly concentrated on the surface of the cerebrum and cerebellum, while the radiation in the eyes is mainly distributed in the outer and anterior tissues. Under combined electromagnetic exposure, the SAR values of tissues increase by 1.17 to 3.53 times compared with single-frequency conditions but remain within safety limits. Considering the long-term use of smartwatches, the potential health risks to developing children still deserve attention.
- 13 March 2026
- Published by MDPI AG in Preprints.org
Open AccessDosimetric Assessment of Multi-Frequency Smartwatch Electromagnetic Exposure on Children’s Sensitive Organs
To assess the electromagnetic effect on the children’s sensitive organs when they using the smartwatches, this study analyzes the electromagnetic dose absorbed by the children, especially calculate the combind electromagnetic exposure, We propose a multi-frequency smartwatch antenna (GPS L1, LTE FDD band1, 2.4G Wi-Fi/Bluetooth) and construct a 6-year-old human model including ten tissues from three sensitive organs (brain, eyes, heart). The Specific Absorption Rate (SAR) distributions are simulated under speaking and listening postures at different frequencies using CST Studio Suite. Furthermore, the SAR distributions under multi-frequency combined electromagnetic exposure are evaluated to investigate the superposition effects of electromagnetic fields. The results show that, when the child uses the smartwatch for 4G communication in the listening posture, the maximum local SAR reaches 1.683 W/kg, which is nearly half of the ICNIRP exposure limit. Electromagnetic radiation in the child’s brain is mainly concentrated on the surface of the cerebrum and cerebellum, while the radiation in the eyes is mainly distributed in the outer and anterior tissues. Under combined electromagnetic exposure, the SAR values of tissues increase by 1.17 to 3.53 times compared with single-frequency conditions but remain within safety limits. Considering the long-term use of smartwatches, the potential health risks to developing children still deserve attention.
- Open Access
- 14 January 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (1) , e0340681
Mobile phone MIMO antenna array miniaturization-based low SAR research in the combined EMF
Due to the diversification of media functions of mobile phones, users can make calls and access the internet simultaneously, which has significantly increased the usage time of mobile phones. The exposure dose of the users in the combined electromagnetic fields (EMF) should be further quantified to better evaluate the public exposure safety. Different from most conventional EMF safety studies that only focus on a single frequency, this work not only discusses the mobile phone simultaneously operated in fourth-generation (4G) and fifth-generation (5G) mobile communications radiation impact on users, but also verifies that the miniaturized mobile phone multiple-input multiple-output (MIMO) antenna array can significantly reduce the specific absorption rate (SAR) absorbed by users. In this article, a miniaturized mobile phone MIMO antenna array is employed as the radiation source, and multi-pose human models are established to simulate the practical utilization of a smartphone. A systematic analysis of the SAR absorbed by the human model is conducted in both single and combined EMF scenarios. The results indicate that the peak SAR in various tissues under multi-frequency exposure is 1.02 to 15.85 times higher than that under single-frequency exposure.
- 14 January 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (1) , e0340681
Open AccessMobile phone MIMO antenna array miniaturization-based low SAR research in the combined EMF
Due to the diversification of media functions of mobile phones, users can make calls and access the internet simultaneously, which has significantly increased the usage time of mobile phones. The exposure dose of the users in the combined electromagnetic fields (EMF) should be further quantified to better evaluate the public exposure safety. Different from most conventional EMF safety studies that only focus on a single frequency, this work not only discusses the mobile phone simultaneously operated in fourth-generation (4G) and fifth-generation (5G) mobile communications radiation impact on users, but also verifies that the miniaturized mobile phone multiple-input multiple-output (MIMO) antenna array can significantly reduce the specific absorption rate (SAR) absorbed by users. In this article, a miniaturized mobile phone MIMO antenna array is employed as the radiation source, and multi-pose human models are established to simulate the practical utilization of a smartphone. A systematic analysis of the SAR absorbed by the human model is conducted in both single and combined EMF scenarios. The results indicate that the peak SAR in various tissues under multi-frequency exposure is 1.02 to 15.85 times higher than that under single-frequency exposure.
- 13 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (2) , 025508
Research on magnetic coupled resonant wireless power transfer system based on low-frequency adjustable electromagnetic metamaterials designed by variable capacitor array
Traditional low-frequency electromagnetic metamaterials (EMM) exhibit limitations such as fixed functionality and poor application flexibility in magnetically coupled resonant wireless power transfer (MCR-WPT) systems, making it difficult to meet the demand for real-time dynamic regulation of transmission performance. This paper proposes a prototype of low-frequency adjustable EMM based on an 8 × 8 variable capacitor array and constructs a closed-loop control system for MCR-WPT using a class AB power amplifier. The system employs a maximum power point tracking (MPPT) algorithm to achieve dynamic real-time regulation under various operational conditions. Experimental results show that by applying a control voltage of 0 V to 3 V, the capacitance value of the variable capacitor array can be flexibly adjusted within the range of 33.2 pF ∼ 19.3 pF. The designed MCR-WPT system exhibits superior transmission performance under different operating conditions, with the maximum output voltage increasing from 0.505 V to 1.438 V. At the same time, it also has a certain effect on anti-offset. This study holds significant value for advancing the development and application of low-frequency adjustable EMM.
- 13 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (2) , 025508
Research on magnetic coupled resonant wireless power transfer system based on low-frequency adjustable electromagnetic metamaterials designed by variable capacitor array
Traditional low-frequency electromagnetic metamaterials (EMM) exhibit limitations such as fixed functionality and poor application flexibility in magnetically coupled resonant wireless power transfer (MCR-WPT) systems, making it difficult to meet the demand for real-time dynamic regulation of transmission performance. This paper proposes a prototype of low-frequency adjustable EMM based on an 8 × 8 variable capacitor array and constructs a closed-loop control system for MCR-WPT using a class AB power amplifier. The system employs a maximum power point tracking (MPPT) algorithm to achieve dynamic real-time regulation under various operational conditions. Experimental results show that by applying a control voltage of 0 V to 3 V, the capacitance value of the variable capacitor array can be flexibly adjusted within the range of 33.2 pF ∼ 19.3 pF. The designed MCR-WPT system exhibits superior transmission performance under different operating conditions, with the maximum output voltage increasing from 0.505 V to 1.438 V. At the same time, it also has a certain effect on anti-offset. This study holds significant value for advancing the development and application of low-frequency adjustable EMM.
- Open Access
- 26 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (20)
Analysis of magnetic coupling resonant wireless power transfer system based on multiple reconfigurable relay coils designed by variable inductors
The performance of the traditional low-power three-coil magnetic coupling resonant wireless power transfer (MCRWPT) system with a single-relay coil still deteriorates significantly during long-distance transmission. To address this question, a reconfigurable relay coil designed with a variable inductor and a maximum power point tracking (MPPT) control strategy is introduced to improve the real-time dynamic performance of a five-coil MCRWPT system. The impact of the number and position of reconfigurable relay coils on the transmission performance of the closed-loop controlled system has been thoroughly analyzed. The study results indicate that, due to the inherent loss of the variable inductor, the performance of the five-coil system cannot be effectively improved when multiple reconfigurable relay coils are employed. When the transmission distance is 500 mm, the original five-coil system's transfer efficiency and output power are 59.01% and 16.48 W. When the relay coil Z2 is replaced by a reconfigurable relay coil, the performance of the system with MPPT control strategy is the best, the highest transfer efficiency of the controlled system is 55.41%, and the maximum output power is 22.56 W. Compared with uncontrolled systems, although the transfer efficiency decreases, the power increases by 36.89%. Furthermore, the system has better misalignment tolerance. The proposed method can significantly improve the dynamic performance of the five-coil MCRWPT system under various working conditions, expected to solve the power supply challenges faced by complex environments, such as the field of electrical insulation.
- 26 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (20)
Open AccessAnalysis of magnetic coupling resonant wireless power transfer system based on multiple reconfigurable relay coils designed by variable inductors
The performance of the traditional low-power three-coil magnetic coupling resonant wireless power transfer (MCRWPT) system with a single-relay coil still deteriorates significantly during long-distance transmission. To address this question, a reconfigurable relay coil designed with a variable inductor and a maximum power point tracking (MPPT) control strategy is introduced to improve the real-time dynamic performance of a five-coil MCRWPT system. The impact of the number and position of reconfigurable relay coils on the transmission performance of the closed-loop controlled system has been thoroughly analyzed. The study results indicate that, due to the inherent loss of the variable inductor, the performance of the five-coil system cannot be effectively improved when multiple reconfigurable relay coils are employed. When the transmission distance is 500 mm, the original five-coil system's transfer efficiency and output power are 59.01% and 16.48 W. When the relay coil Z2 is replaced by a reconfigurable relay coil, the performance of the system with MPPT control strategy is the best, the highest transfer efficiency of the controlled system is 55.41%, and the maximum output power is 22.56 W. Compared with uncontrolled systems, although the transfer efficiency decreases, the power increases by 36.89%. Furthermore, the system has better misalignment tolerance. The proposed method can significantly improve the dynamic performance of the five-coil MCRWPT system under various working conditions, expected to solve the power supply challenges faced by complex environments, such as the field of electrical insulation.
- 21 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Electromagnetic environment compatibility optimization scheme in metro tunnels by using metamaterial-based dual-band miniaturized trackside antennas
- 21 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Electromagnetic environment compatibility optimization scheme in metro tunnels by using metamaterial-based dual-band miniaturized trackside antennas
- Open Access
- 7 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0323299
A novel radiation protection method for miniaturized MIMO mobile terminal antenna design based on metamaterials
In this article, we propose an innovative approach to reduce radiation dose absorption inside human head tissues by shrinking the multiple-input multiple-output (MIMO) terminal geometric area. Initially, we employ COMSOL software to design a MIMO mobile terminal antenna that meets 2G, 3G, 4G, and 5G communication requirements. Through adding the decoupling unit, its geometric area reduces from 58 × 120 mm² to 44 × 80 mm², and its simulations and measurements indicate that the miniaturized MIMO mobile terminal antenna exhibits good radiation performance. Subsequently, we construct a head model based on standard anatomical features, including the scalp, skull, cerebrum, cerebellum, and brainstem. A comparative analysis of the specific absorption rate (SAR) across various cranial tissues, conducted before and after the antenna’s miniaturization, reveals significant reductions: maximum decreases of 85.51% in the scalp, 85.62% in the skull, 89.02% in the cerebrum, 93.04% in the cerebellum, and 88.02% in the brainstem. These findings suggest a significant decrease in the risk of electromagnetic exposure to human subjects by miniaturization. The miniaturization of the MIMO mobile terminal antenna could effectively mitigate the absorption of radiation by head tissues, thereby presenting a novel strategy for electromagnetic radiation protection.
- 7 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0323299
Open AccessA novel radiation protection method for miniaturized MIMO mobile terminal antenna design based on metamaterials
In this article, we propose an innovative approach to reduce radiation dose absorption inside human head tissues by shrinking the multiple-input multiple-output (MIMO) terminal geometric area. Initially, we employ COMSOL software to design a MIMO mobile terminal antenna that meets 2G, 3G, 4G, and 5G communication requirements. Through adding the decoupling unit, its geometric area reduces from 58 × 120 mm² to 44 × 80 mm², and its simulations and measurements indicate that the miniaturized MIMO mobile terminal antenna exhibits good radiation performance. Subsequently, we construct a head model based on standard anatomical features, including the scalp, skull, cerebrum, cerebellum, and brainstem. A comparative analysis of the specific absorption rate (SAR) across various cranial tissues, conducted before and after the antenna’s miniaturization, reveals significant reductions: maximum decreases of 85.51% in the scalp, 85.62% in the skull, 89.02% in the cerebrum, 93.04% in the cerebellum, and 88.02% in the brainstem. These findings suggest a significant decrease in the risk of electromagnetic exposure to human subjects by miniaturization. The miniaturization of the MIMO mobile terminal antenna could effectively mitigate the absorption of radiation by head tissues, thereby presenting a novel strategy for electromagnetic radiation protection.