Amin Banaiemoqadam
Research Subjects
Amin Banaiemoqadam has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ali Hooshyar
Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
7 shared publications - Ali Azizi
Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
3 shared publications - Ehab Fahamy El-Saadany
Khalifa University
2 shared publications - Maher Abdelkhalek Azzouz
University of Windsor
2 shared publications - Seyed Hamid Fathi
Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
2 shared publications - Ahmed Al-Durra
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
1 shared publication
Latest Publications
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4049-4060
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part II: Reactance Method
Part I of this article investigated the performance of distance relays that use phase comparators in systems with inverter-based resources (IBRs). Part II investigates distance relays that are based on the reactance method, another common technique used in existing relays. Similar to Part I, the IBRs in this article comply with the low-voltage ride-through requirements of recent grid codes (including the generation of negative-sequence current), and the relays measure a combination of IBR and load currents. This article will examine if the basic assumptions of the reactance method hold under such scenarios. In addition to theoretical analysis, the article will also present case studies that indicate the differences between the impacts of IBRs on the reactance method and the previously discussed phase comparators, hence the need for separate treatment of the reactance method. The findings of this article are corroborated using PSCAD/EMTDC simulations.
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4049-4060
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part II: Reactance Method
Part I of this article investigated the performance of distance relays that use phase comparators in systems with inverter-based resources (IBRs). Part II investigates distance relays that are based on the reactance method, another common technique used in existing relays. Similar to Part I, the IBRs in this article comply with the low-voltage ride-through requirements of recent grid codes (including the generation of negative-sequence current), and the relays measure a combination of IBR and load currents. This article will examine if the basic assumptions of the reactance method hold under such scenarios. In addition to theoretical analysis, the article will also present case studies that indicate the differences between the impacts of IBRs on the reactance method and the previously discussed phase comparators, hence the need for separate treatment of the reactance method. The findings of this article are corroborated using PSCAD/EMTDC simulations.
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4090-4102
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part I: Phase Comparators
Unconventional fault currents of inverter-based resources (IBRs) can adversely impact distance relays. Despite extensive investigation in the literature, the available studies on this topic mostly suffer from three main shortcomings: (i) they consider only the apparent-impedance-based implementation method of distance protection and do not cover the methods used by relay manufacturers to realize the distance element, (ii) they focus on only the relays that protect the direct tie-lines of IBRs, severely limiting the benefits of these studies for future IBR-centric grids, and (iii) they do not consider the requirements of recent grid codes and standards for the low-voltage ride-through current of IBRs. This article addresses these three shortcomings. Part I of this article is on distance relays that use phase comparators.
- 3 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4090-4102
Impact of Inverter-Based Resources on Different Implementation Methods for Distance Relays—Part I: Phase Comparators
Unconventional fault currents of inverter-based resources (IBRs) can adversely impact distance relays. Despite extensive investigation in the literature, the available studies on this topic mostly suffer from three main shortcomings: (i) they consider only the apparent-impedance-based implementation method of distance protection and do not cover the methods used by relay manufacturers to realize the distance element, (ii) they focus on only the relays that protect the direct tie-lines of IBRs, severely limiting the benefits of these studies for future IBR-centric grids, and (iii) they do not consider the requirements of recent grid codes and standards for the low-voltage ride-through current of IBRs. This article addresses these three shortcomings. Part I of this article is on distance relays that use phase comparators.
- 10 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (1) , 587-601
Eliminating the Need for a Less Strict Requirement for the Negative-Sequence LVRT Current of Type-III Wind Turbine Generators in the IEEE 2800 Standard
Similar to emerging regional grid codes, the recently approved IEEE 2800 Standard mandates that inverter-based resources (IBRs) generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs' negative-sequence current lead the negative-sequence voltage by 90 $^\circ$ –100 $^\circ$ to emulate synchronous generators and reduce the likelihood of protection malfunction. However, the limitations of existing doubly-fed induction generators (DFIGs) led the Standard to exempt the DFIGs from this requirement and allow a wider range for their negative-sequence current angle. Meanwhile, the 2800 Standard also acknowledged that this exemption had unidentified and potentially negative impacts on protective relays. This paper (i) sheds light on several so-far-unknown DFIG characteristics that impact the angle of the negative-sequence current during LVRT, (ii) reveals the impacts of the above DFIG exemption on relays, and (iii) develops a solution to prevent the need for this exemption in the future revisions of the IEEE 2800 Standard.
- 10 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (1) , 587-601
Eliminating the Need for a Less Strict Requirement for the Negative-Sequence LVRT Current of Type-III Wind Turbine Generators in the IEEE 2800 Standard
Similar to emerging regional grid codes, the recently approved IEEE 2800 Standard mandates that inverter-based resources (IBRs) generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs' negative-sequence current lead the negative-sequence voltage by 90 $^\circ$ –100 $^\circ$ to emulate synchronous generators and reduce the likelihood of protection malfunction. However, the limitations of existing doubly-fed induction generators (DFIGs) led the Standard to exempt the DFIGs from this requirement and allow a wider range for their negative-sequence current angle. Meanwhile, the 2800 Standard also acknowledged that this exemption had unidentified and potentially negative impacts on protective relays. This paper (i) sheds light on several so-far-unknown DFIG characteristics that impact the angle of the negative-sequence current during LVRT, (ii) reveals the impacts of the above DFIG exemption on relays, and (iii) develops a solution to prevent the need for this exemption in the future revisions of the IEEE 2800 Standard.
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 319-334
A Blind Spot in the LVRT Current Requirements of Modern Grid Codes for Inverter-Based Resources
Modern grid codes (GCs) require that inverter-based resources (IBRs) inject both positive- and negative-sequence currents during asymmetrical low-voltage ride through (LVRT) conditions. This GC provision prioritizes the reactive currents and also demands maximizing the active positive-sequence current if the IBR has unused current generation capacity when the required reactive current is generated. A variety of inverter control schemes are available to generate positive- and negative-sequence active/reactive currents, and satisfying these GCs seems to be straightforward. However, this paper reveals that the reference current generation methods of existing inverter control schemes fail to fulfil some important requirements of recent GCs. For example, they do not fully utilize the inverter capacity to generate the maximum active and/or reactive current. It is shown that these so-far hidden GC violations can result in a large untapped generation capacity during asymmetrical faults. This paper also develops an algorithm that satisfies recent GCs by deriving the positive- and negative-sequence currents that maximize the IBR’s reactive and active currents while the reactive current is prioritized. The simulation of a grid with high IBR penetration verifies that this new algorithm can unlock the full potential of recent GCs by significantly increasing the power generated during LVRT.
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 319-334
A Blind Spot in the LVRT Current Requirements of Modern Grid Codes for Inverter-Based Resources
Modern grid codes (GCs) require that inverter-based resources (IBRs) inject both positive- and negative-sequence currents during asymmetrical low-voltage ride through (LVRT) conditions. This GC provision prioritizes the reactive currents and also demands maximizing the active positive-sequence current if the IBR has unused current generation capacity when the required reactive current is generated. A variety of inverter control schemes are available to generate positive- and negative-sequence active/reactive currents, and satisfying these GCs seems to be straightforward. However, this paper reveals that the reference current generation methods of existing inverter control schemes fail to fulfil some important requirements of recent GCs. For example, they do not fully utilize the inverter capacity to generate the maximum active and/or reactive current. It is shown that these so-far hidden GC violations can result in a large untapped generation capacity during asymmetrical faults. This paper also develops an algorithm that satisfies recent GCs by deriving the positive- and negative-sequence currents that maximize the IBR’s reactive and active currents while the reactive current is prioritized. The simulation of a grid with high IBR penetration verifies that this new algorithm can unlock the full potential of recent GCs by significantly increasing the power generated during LVRT.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 674-689
Loss-of-Voltage Detection for Relays Protecting Systems With Inverter-Based Resources
Reliable voltage measurement is a pre-requisite for correct operation of a relay's voltage-dependent functions. The secondary circuit of a relay's voltage transformer (VT) is usually fuse-protected. The blowing of a VT's three-phase fuses prevents correct voltage measurement, commonly referred to as the loss-of-voltage (LOV) condition. Relays are equipped with different methods to detect the LOV conditions and avoid confusing them with grid faults. However, this paper shows that existing LOV detection methods are prone to misoperation in the presence of inverter-based resources (IBRs). The paper's findings are corroborated by hardware-in-the-loop testing of relays with the state-of-the-art LOV detection methods. This paper also develops a new LOV detection method for transmission system relays that addresses the unveiled problem. The proposed method considers the fault behavior of IBRs and detects LOVs by examining certain conditions in three stages, namely phase-voltage-check, phase-current-check, and current-transients-check. Simulation studies are used to verify the dependable and secure operation of this new method for different LOVs, faults, IBRs, and VT configurations. The obtained results demonstrate that this method performs successfully regardless of the type of generation units. Moreover, it is sufficiently fast to prevent relay misoperation during LOV conditions and does not require extra hardware.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 674-689
Loss-of-Voltage Detection for Relays Protecting Systems With Inverter-Based Resources
Reliable voltage measurement is a pre-requisite for correct operation of a relay's voltage-dependent functions. The secondary circuit of a relay's voltage transformer (VT) is usually fuse-protected. The blowing of a VT's three-phase fuses prevents correct voltage measurement, commonly referred to as the loss-of-voltage (LOV) condition. Relays are equipped with different methods to detect the LOV conditions and avoid confusing them with grid faults. However, this paper shows that existing LOV detection methods are prone to misoperation in the presence of inverter-based resources (IBRs). The paper's findings are corroborated by hardware-in-the-loop testing of relays with the state-of-the-art LOV detection methods. This paper also develops a new LOV detection method for transmission system relays that addresses the unveiled problem. The proposed method considers the fault behavior of IBRs and detects LOVs by examining certain conditions in three stages, namely phase-voltage-check, phase-current-check, and current-transients-check. Simulation studies are used to verify the dependable and secure operation of this new method for different LOVs, faults, IBRs, and VT configurations. The obtained results demonstrate that this method performs successfully regardless of the type of generation units. Moreover, it is sufficiently fast to prevent relay misoperation during LOV conditions and does not require extra hardware.
- 22 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (5) , 2715-2729
A Comprehensive Dual Current Control Scheme for Inverter-Based Resources to Enable Correct Operation of Protective Relays
Directional, phase-selection, and distance elements of a relay are prone to misoperation in the presence of inverter-based resources (IBRs). To address these problems, modifications of relay elements as well as new control schemes for IBRs have been proposed in the literature. These methods focus mainly on addressing the misoperation of only one of the above relay elements. The available solutions that are based on a new control system focus only on the negative-sequence current loop. Thus, they work only for unbalanced faults. This paper proposes a comprehensive dual current control scheme for IBRs during all types of faults such that all of these relay elements operate correctly. The proposed method controls the IBR to operate as a voltage source behind a virtual impedance in the positive-sequence circuit, and a single impedance in the negative-sequence circuit, thereby emulating the phase angles of a synchronous generator's (SG's) fault current. The proposed method also maximizes the active, and reactive current generation of the IBR during faults, and emulates the incremental sequence current magnitudes of an SG. The proposed method does not require altering the relay elements. Moreover, correct operation of the relay elements is achieved regardless of the fault type, resistance, and location. The effectiveness of the proposed method is verified through not only simulation studies, but also hardware-in-the-loop testing of commercial relays.
- 22 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (5) , 2715-2729
A Comprehensive Dual Current Control Scheme for Inverter-Based Resources to Enable Correct Operation of Protective Relays
Directional, phase-selection, and distance elements of a relay are prone to misoperation in the presence of inverter-based resources (IBRs). To address these problems, modifications of relay elements as well as new control schemes for IBRs have been proposed in the literature. These methods focus mainly on addressing the misoperation of only one of the above relay elements. The available solutions that are based on a new control system focus only on the negative-sequence current loop. Thus, they work only for unbalanced faults. This paper proposes a comprehensive dual current control scheme for IBRs during all types of faults such that all of these relay elements operate correctly. The proposed method controls the IBR to operate as a voltage source behind a virtual impedance in the positive-sequence circuit, and a single impedance in the negative-sequence circuit, thereby emulating the phase angles of a synchronous generator's (SG's) fault current. The proposed method also maximizes the active, and reactive current generation of the IBR during faults, and emulates the incremental sequence current magnitudes of an SG. The proposed method does not require altering the relay elements. Moreover, correct operation of the relay elements is achieved regardless of the fault type, resistance, and location. The effectiveness of the proposed method is verified through not only simulation studies, but also hardware-in-the-loop testing of commercial relays.
- 10 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1455-1466
A Control-Based Solution for Distance Protection of Lines Connected to Converter-Interfaced Sources During Asymmetrical Faults
Full-scale converter-interfaced renewable energy sources (CIRESs) can cause misoperation of distance relays installed in their vicinity. Such failure stems from the different fault behavior of CIRESs and synchronous generators (SGs), based on which available relays have been developed. Several measures have been devised to secure the performance of distance protection by modifying existing relays. This paper proposes a new approach to address misoperation of distance relays during asymmetrical faults by regulating the fault currents of CIRESs such that available distance relays function properly without requiring modification. The prime objective of this method is to mimic certain features of the symmetrical components of SGs' fault currents that affect distance relays. In the meantime, the proposed method satisfies the constraints of a converter, such as its limited phase current magnitude. As a result, correct operation of the distance relays close to CIRESs is ensured regardless of the fault conditions, including its type, resistance, and location. Some salient features of the proposed method are its simplicity, compatibility with off-the-shelf relays, and independence from the voltage and power rating of the CIRES. Moreover, the proposed method uses only local measurements, and so is cost-effective. PSCAD/EMTDC simulation studies verify the performance of this new method.
- 10 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1455-1466
A Control-Based Solution for Distance Protection of Lines Connected to Converter-Interfaced Sources During Asymmetrical Faults
Full-scale converter-interfaced renewable energy sources (CIRESs) can cause misoperation of distance relays installed in their vicinity. Such failure stems from the different fault behavior of CIRESs and synchronous generators (SGs), based on which available relays have been developed. Several measures have been devised to secure the performance of distance protection by modifying existing relays. This paper proposes a new approach to address misoperation of distance relays during asymmetrical faults by regulating the fault currents of CIRESs such that available distance relays function properly without requiring modification. The prime objective of this method is to mimic certain features of the symmetrical components of SGs' fault currents that affect distance relays. In the meantime, the proposed method satisfies the constraints of a converter, such as its limited phase current magnitude. As a result, correct operation of the distance relays close to CIRESs is ensured regardless of the fault conditions, including its type, resistance, and location. Some salient features of the proposed method are its simplicity, compatibility with off-the-shelf relays, and independence from the voltage and power rating of the CIRES. Moreover, the proposed method uses only local measurements, and so is cost-effective. PSCAD/EMTDC simulation studies verify the performance of this new method.
- 20 May 2018
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 46 (10) , 1899-1916
A new integrated high step‐up quasi‐resonant flyback‐forward converter
Summary: This study presents a new high step‐up, high efficiency, flyback‐forward converter. The proposed converter employs 2 transformers, operating in flyback and forward modes at different intervals, to achieve the high voltage gain. In favor of high power density, transformers have been installed on 1 core. Furthermore, all switches are turned on under zero voltage switching condition, and all diodes are turned off under zero current switching condition. Also, the proposed converter utilizes resonant operation that leads to a reduction in switching loss, turning the converter to a highly efficient one. A 150‐W prototype has been implemented to verify the theoretical analysis, and a complete analysis has been done to investigate the effect of transformers integration.
- 20 May 2018
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 46 (10) , 1899-1916
A new integrated high step‐up quasi‐resonant flyback‐forward converter
Summary: This study presents a new high step‐up, high efficiency, flyback‐forward converter. The proposed converter employs 2 transformers, operating in flyback and forward modes at different intervals, to achieve the high voltage gain. In favor of high power density, transformers have been installed on 1 core. Furthermore, all switches are turned on under zero voltage switching condition, and all diodes are turned off under zero current switching condition. Also, the proposed converter utilizes resonant operation that leads to a reduction in switching loss, turning the converter to a highly efficient one. A 150‐W prototype has been implemented to verify the theoretical analysis, and a complete analysis has been done to investigate the effect of transformers integration.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-202
A new current-fed high step-up quasi-resonant DC-DC converter with voltage quadrupler
A new high step-up DC-DC converter with voltage quadrupler (HCVQ) for Fuel Cell (FC) application is presented in this paper. This converter employs two Quasi-Resonant (QR) and Pulse Width Modulation (PWM) schemes, and the converter's performance in these modes is compared. In both schemes, switches work under Zero Voltage Switching (ZVS) condition, and output diodes work under Zero Current Switching (ZCS). As a result of incorporating the resonant operation for main switch in QR scheme, its turn-off voltage and current is lower than PWM scheme, so total switching loss is reduced, and switches have approximately the same conduction losses. The proposed converter in QR scheme operates in Discontinuous Conduction Mode (DCM). Also it has a higher voltage gain and efficiency in comparison with the one using PWM scheme. Moreover, this converter is compared with conventional half-bridge current-fed converter with voltage doubler (HCVD). Finally, two 150 W HCVQ with QR and PWM schemes and one HCVQ are simulated to validate the theoretical and simulation results.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 197-202
A new current-fed high step-up quasi-resonant DC-DC converter with voltage quadrupler
A new high step-up DC-DC converter with voltage quadrupler (HCVQ) for Fuel Cell (FC) application is presented in this paper. This converter employs two Quasi-Resonant (QR) and Pulse Width Modulation (PWM) schemes, and the converter's performance in these modes is compared. In both schemes, switches work under Zero Voltage Switching (ZVS) condition, and output diodes work under Zero Current Switching (ZCS). As a result of incorporating the resonant operation for main switch in QR scheme, its turn-off voltage and current is lower than PWM scheme, so total switching loss is reduced, and switches have approximately the same conduction losses. The proposed converter in QR scheme operates in Discontinuous Conduction Mode (DCM). Also it has a higher voltage gain and efficiency in comparison with the one using PWM scheme. Moreover, this converter is compared with conventional half-bridge current-fed converter with voltage doubler (HCVD). Finally, two 150 W HCVQ with QR and PWM schemes and one HCVQ are simulated to validate the theoretical and simulation results.