Robert Dürichen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Dürichen has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Achim Schweikard
Institute for Robotics and Cognitive Systems, University of Lüubeck, Germany
11 shared publicationsTobias Wissel
Institute for Robotics and Cognitive Systems, University of Lüubeck, Germany
7 shared publicationsDavid A. Clifton
Institute of Biomedical Engineering, University of Oxford, UK
3 shared publicationsA Schlaefer
2 shared publicationsA Schweikard
2 shared publicationsFloris Ernst
Institute for Robotics and Cognitive Systems, University of Lüubeck, Germany
2 shared publications
Latest Publications
- Open Access
Early risk assessment for COVID-19 patients from emergency department data using machine learning
Background Since its emergence in late 2019, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a pandemic, with more than 4.8 million reported cases and 310 000 deaths worldwide. While epidemiological and clinical characteristics of COVID-19 have been reported, risk factors underlying the transition from mild to severe disease among patients remain poorly understood. Methods In this retrospective study, we analysed data of 820 confirmed COVID-19 positive patients admitted to a two-site NHS Trust hospital in London, England, between January 1st and April 23rd, 2020, with a majority of cases occurring in March and April. We extracted anonymised demographic data, physiological clinical variables and laboratory results from electronic healthcare records (EHR) and applied multivariate logistic regression, random forest and extreme gradient boosted trees. To evaluate the potential for early risk assessment, we used data available during patients' initial presentation at the emergency department (ED) to predict deterioration to one of three clinical endpoints in the remainder of the hospital stay: A) admission to intensive care, B) need for mechanical ventilation and C) mortality. Based on the trained models, we extracted the most informative clinical features in determining these patient trajectories. Results Considering our inclusion criteria, we have identified 126 of 820 (15%) patients that required intensive care, 62 of 808 (8%) patients needing mechanical ventilation, and 170 of 630 (27%) cases of in-hospital mortality. Our models learned successfully from early clinical data and predicted clinical endpoints with high accuracy, the best model achieving AUC-ROC scores of 0.75 to 0.83 (F1 scores of 0.41 to 0.56). Younger patient age was associated with an increased risk of receiving intensive care and ventilation, but lower risk of mortality. Clinical indicators of a patient's oxygen supply and selected laboratory results were most predictive of COVID-19 patient trajectories. Conclusion Among COVID-19 patients machine learning can aid in the early identification of those with a poor prognosis, using EHR data collected during a patient's first presentation at ED. Patient age and measures of oxygenation status during ED stay are primary indicators of poor patient outcomes.
Open AccessEarly risk assessment for COVID-19 patients from emergency department data using machine learning
Background Since its emergence in late 2019, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a pandemic, with more than 4.8 million reported cases and 310 000 deaths worldwide. While epidemiological and clinical characteristics of COVID-19 have been reported, risk factors underlying the transition from mild to severe disease among patients remain poorly understood. Methods In this retrospective study, we analysed data of 820 confirmed COVID-19 positive patients admitted to a two-site NHS Trust hospital in London, England, between January 1st and April 23rd, 2020, with a majority of cases occurring in March and April. We extracted anonymised demographic data, physiological clinical variables and laboratory results from electronic healthcare records (EHR) and applied multivariate logistic regression, random forest and extreme gradient boosted trees. To evaluate the potential for early risk assessment, we used data available during patients' initial presentation at the emergency department (ED) to predict deterioration to one of three clinical endpoints in the remainder of the hospital stay: A) admission to intensive care, B) need for mechanical ventilation and C) mortality. Based on the trained models, we extracted the most informative clinical features in determining these patient trajectories. Results Considering our inclusion criteria, we have identified 126 of 820 (15%) patients that required intensive care, 62 of 808 (8%) patients needing mechanical ventilation, and 170 of 630 (27%) cases of in-hospital mortality. Our models learned successfully from early clinical data and predicted clinical endpoints with high accuracy, the best model achieving AUC-ROC scores of 0.75 to 0.83 (F1 scores of 0.41 to 0.56). Younger patient age was associated with an increased risk of receiving intensive care and ventilation, but lower risk of mortality. Clinical indicators of a patient's oxygen supply and selected laboratory results were most predictive of COVID-19 patient trajectories. Conclusion Among COVID-19 patients machine learning can aid in the early identification of those with a poor prognosis, using EHR data collected during a patient's first presentation at ED. Patient age and measures of oxygenation status during ED stay are primary indicators of poor patient outcomes.
- Top Cited PapersOpen Access
Wearable-Based Affect Recognition—A Review
Affect recognition is an interdisciplinary research field bringing together researchers from natural and social sciences. Affect recognition research aims to detect the affective state of a person based on observables, with the goal to, for example, provide reasoning for the person’s decision making or to support mental wellbeing (e.g., stress monitoring). Recently, beside of approaches based on audio, visual or text information, solutions relying on wearable sensors as observables, recording mainly physiological and inertial parameters, have received increasing attention. Wearable systems enable an ideal platform for long-term affect recognition applications due to their rich functionality and form factor, while providing valuable insights during everyday life through integrated sensors. However, existing literature surveys lack a comprehensive overview of state-of-the-art research in wearable-based affect recognition. Therefore, the aim of this paper is to provide a broad overview and in-depth understanding of the theoretical background, methods and best practices of wearable affect and stress recognition. Following a summary of different psychological models, we detail the influence of affective states on the human physiology and the sensors commonly employed to measure physiological changes. Then, we outline lab protocols eliciting affective states and provide guidelines for ground truth generation in field studies. We also describe the standard data processing chain and review common approaches related to the preprocessing, feature extraction and classification steps. By providing a comprehensive summary of the state-of-the-art and guidelines to various aspects, we would like to enable other researchers in the field to conduct and evaluate user studies and develop wearable systems.
Top Cited PapersOpen AccessWearable-Based Affect Recognition—A Review
Affect recognition is an interdisciplinary research field bringing together researchers from natural and social sciences. Affect recognition research aims to detect the affective state of a person based on observables, with the goal to, for example, provide reasoning for the person’s decision making or to support mental wellbeing (e.g., stress monitoring). Recently, beside of approaches based on audio, visual or text information, solutions relying on wearable sensors as observables, recording mainly physiological and inertial parameters, have received increasing attention. Wearable systems enable an ideal platform for long-term affect recognition applications due to their rich functionality and form factor, while providing valuable insights during everyday life through integrated sensors. However, existing literature surveys lack a comprehensive overview of state-of-the-art research in wearable-based affect recognition. Therefore, the aim of this paper is to provide a broad overview and in-depth understanding of the theoretical background, methods and best practices of wearable affect and stress recognition. Following a summary of different psychological models, we detail the influence of affective states on the human physiology and the sensors commonly employed to measure physiological changes. Then, we outline lab protocols eliciting affective states and provide guidelines for ground truth generation in field studies. We also describe the standard data processing chain and review common approaches related to the preprocessing, feature extraction and classification steps. By providing a comprehensive summary of the state-of-the-art and guidelines to various aspects, we would like to enable other researchers in the field to conduct and evaluate user studies and develop wearable systems.
- Open Access
- 11 September 2017
- Published by Association for Computing Machinery (ACM)
- p. 158-165
CNN-based sensor fusion techniques for multimodal human activity recognition
- 11 September 2017
- Published by Association for Computing Machinery (ACM)
- p. 158-165
Open AccessCNN-based sensor fusion techniques for multimodal human activity recognition
- 25 February 2015
- Published by Springer Nature
- p. 227-232
Detecting Respiratory Artifacts from Video Data
- 25 February 2015
- Published by Springer Nature
- p. 227-232
Detecting Respiratory Artifacts from Video Data
- 25 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (20) , 6043-6060
Multivariate respiratory motion prediction
In extracranial robotic radiotherapy, tumour motion is compensated by tracking external and internal surrogates. To compensate system specific time delays, time series prediction of the external optical surrogates is used. We investigate whether the prediction accuracy can be increased by expanding the current clinical setup by an accelerometer, a strain belt and a flow sensor. Four previously published prediction algorithms are adapted to multivariate inputs-normalized least mean squares (nLMS), wavelet-based least mean squares (wLMS), support vector regression (SVR) and relevance vector machines (RVM)-and evaluated for three different prediction horizons. The measurement involves 18 subjects and consists of two phases, focusing on long term trends (M1) and breathing artefacts (M2). To select the most relevant and least redundant sensors, a sequential forward selection (SFS) method is proposed. Using a multivariate setting, the results show that the clinically used nLMS algorithm is susceptible to large outliers. In the case of irregular breathing (M2), the mean root mean square error (RMSE) of a univariate nLMS algorithm is 0.66 mm and can be decreased to 0.46 mm by a multivariate RVM model (best algorithm on average). To investigate the full potential of this approach, the optimal sensor combination was also estimated on the complete test set. The results indicate that a further decrease in RMSE is possible for RVM (to 0.42 mm). This motivates further research about sensor selection methods. Besides the optical surrogates, the sensors most frequently selected by the algorithms are the accelerometer and the strain belt. These sensors could be easily integrated in the current clinical setup and would allow a more precise motion compensation.
- 25 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (20) , 6043-6060
Multivariate respiratory motion prediction
In extracranial robotic radiotherapy, tumour motion is compensated by tracking external and internal surrogates. To compensate system specific time delays, time series prediction of the external optical surrogates is used. We investigate whether the prediction accuracy can be increased by expanding the current clinical setup by an accelerometer, a strain belt and a flow sensor. Four previously published prediction algorithms are adapted to multivariate inputs-normalized least mean squares (nLMS), wavelet-based least mean squares (wLMS), support vector regression (SVR) and relevance vector machines (RVM)-and evaluated for three different prediction horizons. The measurement involves 18 subjects and consists of two phases, focusing on long term trends (M1) and breathing artefacts (M2). To select the most relevant and least redundant sensors, a sequential forward selection (SFS) method is proposed. Using a multivariate setting, the results show that the clinically used nLMS algorithm is susceptible to large outliers. In the case of irregular breathing (M2), the mean root mean square error (RMSE) of a univariate nLMS algorithm is 0.66 mm and can be decreased to 0.46 mm by a multivariate RVM model (best algorithm on average). To investigate the full potential of this approach, the optimal sensor combination was also estimated on the complete test set. The results indicate that a further decrease in RMSE is possible for RVM (to 0.42 mm). This motivates further research about sensor selection methods. Besides the optical surrogates, the sensors most frequently selected by the algorithms are the accelerometer and the strain belt. These sensors could be easily integrated in the current clinical setup and would allow a more precise motion compensation.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15512541,p. 1-6
A unified approach for respiratory motion prediction and correlation with multi-task Gaussian Processes
In extracranial robotic radiotherapy, tumour motion due to respiration is compensated based external markers. Two models are typically used to enable a real-time adaptation. A prediction model, which compensates time latencies of the treatment systems due to e.g. kinematic limitations, and a correlation model, which estimates the internal tumour position based on external markers. We present a novel approach based on multi-task Gaussian Processes (MTGP) which enables an efficient combination of both models by simultaneously learning the correlation and temporal delays between markers. The approach is evaluated using datasets acquired from porcine and human studies. We conclude that the prediction accuracy of MTGP is superior to that of existing methods and can be further increased by using multivariate input data. We investigate the dependency of the number of internal training points and the potential for using the marginal likelihood for model selection.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15512541,p. 1-6
A unified approach for respiratory motion prediction and correlation with multi-task Gaussian Processes
In extracranial robotic radiotherapy, tumour motion due to respiration is compensated based external markers. Two models are typically used to enable a real-time adaptation. A prediction model, which compensates time latencies of the treatment systems due to e.g. kinematic limitations, and a correlation model, which estimates the internal tumour position based on external markers. We present a novel approach based on multi-task Gaussian Processes (MTGP) which enables an efficient combination of both models by simultaneously learning the correlation and temporal delays between markers. The approach is evaluated using datasets acquired from porcine and human studies. We conclude that the prediction accuracy of MTGP is superior to that of existing methods and can be further increased by using multivariate input data. We investigate the dependency of the number of internal training points and the potential for using the marginal likelihood for model selection.
- Top Cited Papers
- 28 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (1) , 314-322
Multitask Gaussian Processes for Multivariate Physiological Time-Series Analysis
Gaussian process (GP) models are a flexible means of performing nonparametric Bayesian regression. However, GP models in healthcare are often only used to model a single univariate output time series, denoted as single-task GPs (STGP). Due to an increasing prevalence of sensors in healthcare settings, there is an urgent need for robust multivariate time-series tools. Here, we propose a method using multitask GPs (MTGPs) which can model multiple correlated multivariate physiological time series simultaneously. The flexible MTGP framework can learn the correlation between multiple signals even though they might be sampled at different frequencies and have training sets available for different intervals. Furthermore, prior knowledge of any relationship between the time series such as delays and temporal behavior can be easily integrated. A novel normalization is proposed to allow interpretation of the various hyperparameters used in the MTGP. We investigate MTGPs for physiological monitoring with synthetic data sets and two real-world problems from the field of patient monitoring and radiotherapy. The results are compared with standard Gaussian processes and other existing methods in the respective biomedical application areas. In both cases, we show that our framework learned the correlation between physiological time series efficiently, outperforming the existing state of the art.
- 28 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 62 (1) , 314-322
Top Cited PapersMultitask Gaussian Processes for Multivariate Physiological Time-Series Analysis
Gaussian process (GP) models are a flexible means of performing nonparametric Bayesian regression. However, GP models in healthcare are often only used to model a single univariate output time series, denoted as single-task GPs (STGP). Due to an increasing prevalence of sensors in healthcare settings, there is an urgent need for robust multivariate time-series tools. Here, we propose a method using multitask GPs (MTGPs) which can model multiple correlated multivariate physiological time series simultaneously. The flexible MTGP framework can learn the correlation between multiple signals even though they might be sampled at different frequencies and have training sets available for different intervals. Furthermore, prior knowledge of any relationship between the time series such as delays and temporal behavior can be easily integrated. A novel normalization is proposed to allow interpretation of the various hyperparameters used in the MTGP. We investigate MTGPs for physiological monitoring with synthetic data sets and two real-world problems from the field of patient monitoring and radiotherapy. The results are compared with standard Gaussian processes and other existing methods in the respective biomedical application areas. In both cases, we show that our framework learned the correlation between physiological time series efficiently, outperforming the existing state of the art.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21682194,p. 492-495
Multi-task Gaussian process models for biomedical applications
Gaussian process (GP) models are a flexible means of performing non-parametric Bayesian regression. However, the majority of existing work using GP models in healthcare data is defined for univariate output time-series, denoted as single-task GPs (STGP). Here, we investigate how GPs could be used to model multiple correlated univariate physiological time-series simultaneously. The resulting multi-task GP (MTGP) framework can learn the correlation within multiple signals even though they might be sampled at different frequencies and have training sets available for different intervals. We illustrate the basic properties of MTGPs using a synthetic case-study with respiratory motion data. Finally, two real-world biomedical problems are investigated from the field of patient monitoring and motion compensation in radiotherapy. The results are compared to STGPs and other standard methods in the respective fields. In both cases, MTGPs learned the correlation between physiological time-series efficiently, which leads to improved modelling accuracy.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21682194,p. 492-495
Multi-task Gaussian process models for biomedical applications
Gaussian process (GP) models are a flexible means of performing non-parametric Bayesian regression. However, the majority of existing work using GP models in healthcare data is defined for univariate output time-series, denoted as single-task GPs (STGP). Here, we investigate how GPs could be used to model multiple correlated univariate physiological time-series simultaneously. The resulting multi-task GP (MTGP) framework can learn the correlation within multiple signals even though they might be sampled at different frequencies and have training sets available for different intervals. We illustrate the basic properties of MTGPs using a synthetic case-study with respiratory motion data. Finally, two real-world biomedical problems are investigated from the field of patient monitoring and motion compensation in radiotherapy. The results are compared to STGPs and other standard methods in the respective fields. In both cases, MTGPs learned the correlation between physiological time-series efficiently, which leads to improved modelling accuracy.
- 16 May 2014
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (4) , 363-371
Controlling motion prediction errors in radiotherapy with relevance vector machines
Robotic radiotherapy can precisely ablate moving tumors when time latencies have been compensated. Recently, relevance vector machines (RVM), a probabilistic regression technique, outperformed six other prediction algorithms for respiratory compensation. The method has the distinct advantage that each predicted point is assumed to be drawn from a normal distribution. Second-order statistics, the predicted variance, were used to control RVM prediction error during a treatment and to construct hybrid prediction algorithms. First, the duty cycle and the precision were correlated to the variance by interrupting the treatment if the variance exceeds a threshold. Second, two hybrid algorithms based on the variance were developed, one consisting of multiple RVMs (HYB(RVM)) and the other of a combination between a wavelet-based least mean square algorithm (wLMS) and a RVM (HYB(wLMS-RVM)). The variance for different motion traces was analyzed to reveal a characteristic variance pattern which gives insight in what kind of prediction errors can be controlled by the variance. Limiting the variance by a threshold resulted in an increased precision with a decreased duty cycle. All hybrid algorithms showed an increased prediction accuracy compared to using only their individual algorithms. The best hybrid algorithm, HYB(RVM), can decrease the mean RMSE over all 304 motion traces from 0.18 mm for a linear RVM to 0.17 mm. The predicted variance was shown to be an efficient metric to control prediction errors, resulting in a more robust radiotherapy treatment. The hybrid algorithm HYB(RVM) could be translated to clinical practice. It does not require further parameters, can be completely parallelised and easily further extended.
- 16 May 2014
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (4) , 363-371
Controlling motion prediction errors in radiotherapy with relevance vector machines
Robotic radiotherapy can precisely ablate moving tumors when time latencies have been compensated. Recently, relevance vector machines (RVM), a probabilistic regression technique, outperformed six other prediction algorithms for respiratory compensation. The method has the distinct advantage that each predicted point is assumed to be drawn from a normal distribution. Second-order statistics, the predicted variance, were used to control RVM prediction error during a treatment and to construct hybrid prediction algorithms. First, the duty cycle and the precision were correlated to the variance by interrupting the treatment if the variance exceeds a threshold. Second, two hybrid algorithms based on the variance were developed, one consisting of multiple RVMs (HYB(RVM)) and the other of a combination between a wavelet-based least mean square algorithm (wLMS) and a RVM (HYB(wLMS-RVM)). The variance for different motion traces was analyzed to reveal a characteristic variance pattern which gives insight in what kind of prediction errors can be controlled by the variance. Limiting the variance by a threshold resulted in an increased precision with a decreased duty cycle. All hybrid algorithms showed an increased prediction accuracy compared to using only their individual algorithms. The best hybrid algorithm, HYB(RVM), can decrease the mean RMSE over all 304 motion traces from 0.18 mm for a linear RVM to 0.17 mm. The predicted variance was shown to be an efficient metric to control prediction errors, resulting in a more robust radiotherapy treatment. The hybrid algorithm HYB(RVM) could be translated to clinical practice. It does not require further parameters, can be completely parallelised and easily further extended.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5678-5681
Evaluation of the potential of multi-modal sensors for respiratory motion prediction and correlation
In modern robotic radiotherapy, precise radiation of moving tumors is possible by tracking external optical surrogates. The surrogates are used to compensate for time delays and to predict internal landmarks using a correlation model. The correlation depends significantly on the surrogate position and breathing characteristics of the patient. In this context, we aim to increase the accuracy and robustness of prediction and correlation models by using a multi-modal sensor setup. Here, we evaluate the correlation coefficient of a strain belt, an acceleration and temperature sensor (air flow) with respect to external optical sensors and one internal landmark in the liver, measured by 3D ultrasound. The focus of this study is the influence of breathing artefacts, like coughing and harrumphing. Evaluating seven subjects, we found a strong decrease of the correlation for all modalities in case of artefacts. The results indicate that no precise motion compensation during these times is possible. Overall, we found that apart from the optical markers, the strain belt and temperature sensor data show the best correlation to external and internal motion.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 5678-5681
Evaluation of the potential of multi-modal sensors for respiratory motion prediction and correlation
In modern robotic radiotherapy, precise radiation of moving tumors is possible by tracking external optical surrogates. The surrogates are used to compensate for time delays and to predict internal landmarks using a correlation model. The correlation depends significantly on the surrogate position and breathing characteristics of the patient. In this context, we aim to increase the accuracy and robustness of prediction and correlation models by using a multi-modal sensor setup. Here, we evaluate the correlation coefficient of a strain belt, an acceleration and temperature sensor (air flow) with respect to external optical sensors and one internal landmark in the liver, measured by 3D ultrasound. The focus of this study is the influence of breathing artefacts, like coughing and harrumphing. Evaluating seven subjects, we found a strong decrease of the correlation for all modalities in case of artefacts. The results indicate that no precise motion compensation during these times is possible. Overall, we found that apart from the optical markers, the strain belt and temperature sensor data show the best correlation to external and internal motion.