Stefano Longobardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefano Longobardi has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Steven Alexander Niederer
Imperial College London
7 shared publications - Gernot Plank
Gottfried Schatz Research Center: Division of Medical Physics and Biophysics, Medical University of Graz, Graz, Austria
3 shared publications - Marina Strocchi
National Heart and Lung Institute, Imperial College London , London W12 0NN, UK
3 shared publications - Anna Sher
Pfizer Inc Cambridge Massachusetts USA
2 shared publications - Christoph M. Augustin
Gottfried Schatz Research Center, Division of Biophysics Medical University of Graz Graz Austria
2 shared publications - Cristobal Rodero
Affiliation National Heart and Lung Institute, Imperial College London, London, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 27 January 2026
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 22 (1) , e1013889
A model for the human fetal ventricular myocyte electrophysiology
Fetal cardiac arrhythmias can lead to stillbirth, but direct studies on the human fetal heart are challenging. To address this, we developed a computational model of human fetal ventricular myocyte (hfVM) electrophysiology, focusing on early gestation (10 weeks). This model incorporates major ionic currents, including fetal-specific T-type calcium and funny currents, and is calibrated using mRNA expression data and experimental measurements. The hfVM model replicates key electrophysiological features, such as a shorter action potential duration and a more positive resting membrane potential compared to adult cells. Global sensitivity analysis reveals that the resting membrane potential is primarily influenced by the funny current and I K1 , while action potential repolarisation depends mainly on I Kr . Additionally, the sarcoplasmic reticulum contributes to calcium release, but less so than in adults; instead, the T-type calcium current and the sodium-calcium exchanger are more prominent in initiating calcium transients. This is the first human fetal ventricular myocyte model available for studying fetal cardiac physiology, pathology, and potential pharmacological interventions. It provides novel insights into the dominant ion channels governing fetal electrophysiology and calcium dynamics, offering a foundation for understanding arrhythmias and guiding therapeutic strategies.
- 27 January 2026
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 22 (1) , e1013889
Open AccessA model for the human fetal ventricular myocyte electrophysiology
Fetal cardiac arrhythmias can lead to stillbirth, but direct studies on the human fetal heart are challenging. To address this, we developed a computational model of human fetal ventricular myocyte (hfVM) electrophysiology, focusing on early gestation (10 weeks). This model incorporates major ionic currents, including fetal-specific T-type calcium and funny currents, and is calibrated using mRNA expression data and experimental measurements. The hfVM model replicates key electrophysiological features, such as a shorter action potential duration and a more positive resting membrane potential compared to adult cells. Global sensitivity analysis reveals that the resting membrane potential is primarily influenced by the funny current and I K1 , while action potential repolarisation depends mainly on I Kr . Additionally, the sarcoplasmic reticulum contributes to calcium release, but less so than in adults; instead, the T-type calcium current and the sodium-calcium exchanger are more prominent in initiating calcium transients. This is the first human fetal ventricular myocyte model available for studying fetal cardiac physiology, pathology, and potential pharmacological interventions. It provides novel insights into the dominant ion channels governing fetal electrophysiology and calcium dynamics, offering a foundation for understanding arrhythmias and guiding therapeutic strategies.
- Open Access
- 19 March 2025
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 22 (224) , 20240765
Reducing transmission in multiple settings is required to eliminate the risk of major Ebola outbreaks: a mathematical modelling study
The Ebola virus (EV) persists in animal populations, with zoonotic transmission to humans occurring every few months or years. When zoonotic transmission arises, it is important to understand which interventions are most effective at preventing a major outbreak driven by human-to-human transmission. Here, we analyse a mathematical model of EV transmission and calculate the probability of a major outbreak starting from a single introduced case. We consider community, funeral and healthcare facility transmission and conduct sensitivity analyses to explore the effects of non-pharmaceutical interventions (NPIs) that influence these transmission routes. We find that, if the index case is treated in the community, then the elimination of transmission at funerals reduces the probability of a major outbreak substantially (from 0.410 to 0.066 under our baseline model parametrization). However, eliminating the risk of major outbreaks entirely requires combinations of measures that limit transmission in different settings, such as community engagement to promote safe burial practices and implementation of barrier nursing in healthcare facilities. In addition to generating insights into the drivers of Ebola outbreaks, this research provides a modelling framework for assessing the effectiveness of interventions at mitigating outbreaks of other infectious diseases with transmission in multiple settings.
- 19 March 2025
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 22 (224) , 20240765
Open AccessReducing transmission in multiple settings is required to eliminate the risk of major Ebola outbreaks: a mathematical modelling study
The Ebola virus (EV) persists in animal populations, with zoonotic transmission to humans occurring every few months or years. When zoonotic transmission arises, it is important to understand which interventions are most effective at preventing a major outbreak driven by human-to-human transmission. Here, we analyse a mathematical model of EV transmission and calculate the probability of a major outbreak starting from a single introduced case. We consider community, funeral and healthcare facility transmission and conduct sensitivity analyses to explore the effects of non-pharmaceutical interventions (NPIs) that influence these transmission routes. We find that, if the index case is treated in the community, then the elimination of transmission at funerals reduces the probability of a major outbreak substantially (from 0.410 to 0.066 under our baseline model parametrization). However, eliminating the risk of major outbreaks entirely requires combinations of measures that limit transmission in different settings, such as community engagement to promote safe burial practices and implementation of barrier nursing in healthcare facilities. In addition to generating insights into the drivers of Ebola outbreaks, this research provides a modelling framework for assessing the effectiveness of interventions at mitigating outbreaks of other infectious diseases with transmission in multiple settings.
- Open Access
- 26 June 2023
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 19 (6) , e1011257
Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulators
Cardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes.
- 26 June 2023
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 19 (6) , e1011257
Open AccessCell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulators
Cardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes.
- Open Access
- 1 April 2022
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 18 (4) , e1010030
Modelling the interaction between stem cells derived cardiomyocytes patches and host myocardium to aid non-arrhythmic engineered heart tissue design
Application of epicardial patches constructed from human-induced pluripotent stem cell- derived cardiomyocytes (hiPSC-CMs) has been proposed as a long-term therapy to treat scarred hearts post myocardial infarction (MI). Understanding electrical interaction between engineered heart tissue patches (EHT) and host myocardium represents a key step toward a successful patch engraftment. EHT retain different electrical properties with respect to the host heart tissue due to the hiPSC-CMs immature phenotype, which may lead to increased arrhythmia risk. We developed a modelling framework to examine the influence of patch design on electrical activation at the engraftment site. We performed an in silico investigation of different patch design approaches to restore pre-MI activation properties and evaluated the associated arrhythmic risk. We developed an in silico cardiac electrophysiology model of a transmural cross section of host myocardium. The model featured an infarct region, an epicardial patch spanning the infarct region and a bath region. The patch is modelled as a layer of hiPSC-CM, combined with a layer of conductive polymer (CP). Tissue and patch geometrical dimensions and conductivities were incorporated through 10 modifiable model parameters. We validated our model against 4 independent experimental studies and showed that it can qualitatively reproduce their findings. We performed a global sensitivity analysis (GSA) to isolate the most important parameters, showing that the stimulus propagation is mainly governed by the scar depth, radius and conductivity when the scar is not transmural, and by the EHT patch conductivity when the scar is transmural. We assessed the relevance of small animal studies to humans by comparing simulations of rat, rabbit and human myocardium. We found that stimulus propagation paths and GSA sensitivity indices are consistent across species. We explored which EHT design variables have the potential to restore physiological propagation. Simulations predict that increasing EHT conductivity from 0.28 to 1–1.1 S/m recovered physiological activation in rat, rabbit and human. Finally, we assessed arrhythmia risk related to increasing EHT conductivity and tested increasing the EHT Na+ channel density as an alternative strategy to match healthy activation. Our results revealed a greater arrhythmia risk linked to increased EHT conductivity compared to increased Na+ channel density. We demonstrated that our modeling framework could capture the interaction between host and EHT patches observed in in vitro experiments. We showed that large (patch and tissue dimensions) and small (cardiac myocyte electrophysiology) scale differences between small animals and humans do not alter EHT patch effect on infarcted tissue. Our model revealed that only when the scar is transmural do EHT properties impact activation times and isolated the EHT conductivity as the main parameter influencing propagation. We predicted that restoring physiological activation by tuning EHT conductivity is possible but may promote arrhythmic behavior. Finally, our model suggests that acting on hiPSC-CMs low action potential upstroke velocity and lack of IK1 may restore pre-MI activation while not promoting arrhythmia.
- 1 April 2022
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 18 (4) , e1010030
Open AccessModelling the interaction between stem cells derived cardiomyocytes patches and host myocardium to aid non-arrhythmic engineered heart tissue design
Application of epicardial patches constructed from human-induced pluripotent stem cell- derived cardiomyocytes (hiPSC-CMs) has been proposed as a long-term therapy to treat scarred hearts post myocardial infarction (MI). Understanding electrical interaction between engineered heart tissue patches (EHT) and host myocardium represents a key step toward a successful patch engraftment. EHT retain different electrical properties with respect to the host heart tissue due to the hiPSC-CMs immature phenotype, which may lead to increased arrhythmia risk. We developed a modelling framework to examine the influence of patch design on electrical activation at the engraftment site. We performed an in silico investigation of different patch design approaches to restore pre-MI activation properties and evaluated the associated arrhythmic risk. We developed an in silico cardiac electrophysiology model of a transmural cross section of host myocardium. The model featured an infarct region, an epicardial patch spanning the infarct region and a bath region. The patch is modelled as a layer of hiPSC-CM, combined with a layer of conductive polymer (CP). Tissue and patch geometrical dimensions and conductivities were incorporated through 10 modifiable model parameters. We validated our model against 4 independent experimental studies and showed that it can qualitatively reproduce their findings. We performed a global sensitivity analysis (GSA) to isolate the most important parameters, showing that the stimulus propagation is mainly governed by the scar depth, radius and conductivity when the scar is not transmural, and by the EHT patch conductivity when the scar is transmural. We assessed the relevance of small animal studies to humans by comparing simulations of rat, rabbit and human myocardium. We found that stimulus propagation paths and GSA sensitivity indices are consistent across species. We explored which EHT design variables have the potential to restore physiological propagation. Simulations predict that increasing EHT conductivity from 0.28 to 1–1.1 S/m recovered physiological activation in rat, rabbit and human. Finally, we assessed arrhythmia risk related to increasing EHT conductivity and tested increasing the EHT Na+ channel density as an alternative strategy to match healthy activation. Our results revealed a greater arrhythmia risk linked to increased EHT conductivity compared to increased Na+ channel density. We demonstrated that our modeling framework could capture the interaction between host and EHT patches observed in in vitro experiments. We showed that large (patch and tissue dimensions) and small (cardiac myocyte electrophysiology) scale differences between small animals and humans do not alter EHT patch effect on infarcted tissue. Our model revealed that only when the scar is transmural do EHT properties impact activation times and isolated the EHT conductivity as the main parameter influencing propagation. We predicted that restoring physiological activation by tuning EHT conductivity is possible but may promote arrhythmic behavior. Finally, our model suggests that acting on hiPSC-CMs low action potential upstroke velocity and lack of IK1 may restore pre-MI activation while not promoting arrhythmia.
- Open Access
- 30 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (10) , 3216-3223
Global Sensitivity Analysis of Four Chamber Heart Hemodynamics Using Surrogate Models
Computational Fluid Dynamics (CFD) is used to assist in designing artificial valves and planning procedures, focusing on local flow features. However, assessing the impact on overall cardiovascular function or predicting longer-term outcomes may requires more comprehensive whole heart CFD models. Fitting such models to patient data requires numerous computationally expensive simulations, and depends on specific clinical measurements to constrain model parameters, hampering clinical adoption. Surrogate models can help to accelerate the fitting process while accounting for the added uncertainty. We create a validated patient-specific four-chamber heart CFD model based on the Navier-Stokes-Brinkman (NSB) equations and test Gaussian Process Emulators (GPEs) as a surrogate model for performing a variance-based global sensitivity analysis (GSA). GSA identified preload as the dominant driver of flow in both the right and left side of the heart, respectively. Left-right differences were seen in terms of vascular outflow resistances, with pulmonary artery resistance having a much larger impact on flow than aortic resistance. Our results suggest that GPEs can be used to identify parameters in personalized whole heart CFD models, and highlight the importance of accurate preload measurements.
- 30 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (10) , 3216-3223
Open AccessGlobal Sensitivity Analysis of Four Chamber Heart Hemodynamics Using Surrogate Models
Computational Fluid Dynamics (CFD) is used to assist in designing artificial valves and planning procedures, focusing on local flow features. However, assessing the impact on overall cardiovascular function or predicting longer-term outcomes may requires more comprehensive whole heart CFD models. Fitting such models to patient data requires numerous computationally expensive simulations, and depends on specific clinical measurements to constrain model parameters, hampering clinical adoption. Surrogate models can help to accelerate the fitting process while accounting for the added uncertainty. We create a validated patient-specific four-chamber heart CFD model based on the Navier-Stokes-Brinkman (NSB) equations and test Gaussian Process Emulators (GPEs) as a surrogate model for performing a variance-based global sensitivity analysis (GSA). GSA identified preload as the dominant driver of flow in both the right and left side of the heart, respectively. Left-right differences were seen in terms of vascular outflow resistances, with pulmonary artery resistance having a much larger impact on flow than aortic resistance. Our results suggest that GPEs can be used to identify parameters in personalized whole heart CFD models, and highlight the importance of accurate preload measurements.
- Open Access
- 6 December 2021
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 17 (12) , e1009646
In silico identification of potential calcium dynamics and sarcomere targets for recovering left ventricular function in rat heart failure with preserved ejection fraction
Heart failure with preserved ejection fraction (HFpEF) is a complex disease associated with multiple co-morbidities, where impaired cardiac mechanics are often the end effect. At the cellular level, cardiac mechanics can be pharmacologically manipulated by altering calcium signalling and the sarcomere. However, the link between cellular level modulations and whole organ pump function is incompletely understood. Our goal is to develop and use a multi-scale computational cardiac mechanics model of the obese ZSF1 HFpEF rat to identify important biomechanical mechanisms that underpin impaired cardiac function and to predict how whole-heart mechanical function can be recovered through altering cellular calcium dynamics and/or cellular contraction. The rat heart was modelled using a 3D biventricular biomechanics model. Biomechanics were described by 16 parameters, corresponding to intracellular calcium transient, sarcomere dynamics, cardiac tissue and hemodynamics properties. The model simulated left ventricular (LV) pressure-volume loops that were described by 14 scalar features. We trained a Gaussian process emulator to map the 16 input parameters to each of the 14 outputs. A global sensitivity analysis was performed, and identified calcium dynamics and thin and thick filament kinetics as key determinants of the organ scale pump function. We employed Bayesian history matching to build a model of the ZSF1 rat heart. Next, we recovered the LV function, described by ejection fraction, peak pressure, maximum rate of pressure rise and isovolumetric relaxation time constant. We found that by manipulating calcium, thin and thick filament properties we can recover 34%, 28% and 24% of the LV function in the ZSF1 rat heart, respectively, and 39% if we manipulate all of them together. We demonstrated how a combination of biophysically based models and their derived emulators can be used to identify potential pharmacological targets. We predicted that cardiac function can be best recovered in ZSF1 rats by desensitising the myofilament and reducing the affinity to intracellular calcium concentration and overall prolonging the sarcomere staying in the active force generating state.
- 6 December 2021
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 17 (12) , e1009646
Open AccessIn silico identification of potential calcium dynamics and sarcomere targets for recovering left ventricular function in rat heart failure with preserved ejection fraction
Heart failure with preserved ejection fraction (HFpEF) is a complex disease associated with multiple co-morbidities, where impaired cardiac mechanics are often the end effect. At the cellular level, cardiac mechanics can be pharmacologically manipulated by altering calcium signalling and the sarcomere. However, the link between cellular level modulations and whole organ pump function is incompletely understood. Our goal is to develop and use a multi-scale computational cardiac mechanics model of the obese ZSF1 HFpEF rat to identify important biomechanical mechanisms that underpin impaired cardiac function and to predict how whole-heart mechanical function can be recovered through altering cellular calcium dynamics and/or cellular contraction. The rat heart was modelled using a 3D biventricular biomechanics model. Biomechanics were described by 16 parameters, corresponding to intracellular calcium transient, sarcomere dynamics, cardiac tissue and hemodynamics properties. The model simulated left ventricular (LV) pressure-volume loops that were described by 14 scalar features. We trained a Gaussian process emulator to map the 16 input parameters to each of the 14 outputs. A global sensitivity analysis was performed, and identified calcium dynamics and thin and thick filament kinetics as key determinants of the organ scale pump function. We employed Bayesian history matching to build a model of the ZSF1 rat heart. Next, we recovered the LV function, described by ejection fraction, peak pressure, maximum rate of pressure rise and isovolumetric relaxation time constant. We found that by manipulating calcium, thin and thick filament properties we can recover 34%, 28% and 24% of the LV function in the ZSF1 rat heart, respectively, and 39% if we manipulate all of them together. We demonstrated how a combination of biophysically based models and their derived emulators can be used to identify potential pharmacological targets. We predicted that cardiac function can be best recovered in ZSF1 rats by desensitising the myofilament and reducing the affinity to intracellular calcium concentration and overall prolonging the sarcomere staying in the active force generating state.
- 18 June 2021
- Published by Springer Nature
- p. 406-415
In Silico Mapping of the Omecamtiv Mecarbil Effects from the Sarcomere to the Whole-Heart and Back Again
- 18 June 2021
- Published by Springer Nature
- p. 406-415
In Silico Mapping of the Omecamtiv Mecarbil Effects from the Sarcomere to the Whole-Heart and Back Again
- Top Cited PapersOpen Access
- 15 April 2021
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 17 (4) , e1008851
Linking statistical shape models and simulated function in the healthy adult human heart
Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n= 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R= 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.
- 15 April 2021
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 17 (4) , e1008851
Top Cited PapersOpen AccessLinking statistical shape models and simulated function in the healthy adult human heart
Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n= 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R= 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
Modelling the Effects of Conductive Polymers and Stem Cells Derived Myocytes on Scarred Heart Tissue
- 30 December 2020
- Published by Computing in Cardiology
Open AccessModelling the Effects of Conductive Polymers and Stem Cells Derived Myocytes on Scarred Heart Tissue
- Open Access
- 25 May 2020
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 378 (2173) , 20190334
Predicting left ventricular contractile function via Gaussian process emulation in aortic-banded rats
Cardiac contraction is the result of integrated cellular, tissue and organ function. Biophysical in silico cardiac models offer a systematic approach for studying these multi-scale interactions. The computational cost of such models is high, due to their multi-parametric and nonlinear nature. This has so far made it difficult to perform model fitting and prevented global sensitivity analysis (GSA) studies. We propose a machine learning approach based on Gaussian process emulation of model simulations using probabilistic surrogate models, which enables model parameter inference via a Bayesian history matching (HM) technique and GSA on whole-organ mechanics. This framework is applied to model healthy and aortic-banded hypertensive rats, a commonly used animal model of heart failure disease. The obtained probabilistic surrogate models accurately predicted the left ventricular pump function ( R 2 = 0.92 for ejection fraction). The HM technique allowed us to fit both the control and diseased virtual bi-ventricular rat heart models to magnetic resonance imaging and literature data, with model outputs from the constrained parameter space falling within 2 SD of the respective experimental values. The GSA identified Troponin C and cross-bridge kinetics as key parameters in determining both systolic and diastolic ventricular function. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’.
- 25 May 2020
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 378 (2173) , 20190334
Open AccessPredicting left ventricular contractile function via Gaussian process emulation in aortic-banded rats
Cardiac contraction is the result of integrated cellular, tissue and organ function. Biophysical in silico cardiac models offer a systematic approach for studying these multi-scale interactions. The computational cost of such models is high, due to their multi-parametric and nonlinear nature. This has so far made it difficult to perform model fitting and prevented global sensitivity analysis (GSA) studies. We propose a machine learning approach based on Gaussian process emulation of model simulations using probabilistic surrogate models, which enables model parameter inference via a Bayesian history matching (HM) technique and GSA on whole-organ mechanics. This framework is applied to model healthy and aortic-banded hypertensive rats, a commonly used animal model of heart failure disease. The obtained probabilistic surrogate models accurately predicted the left ventricular pump function ( R 2 = 0.92 for ejection fraction). The HM technique allowed us to fit both the control and diseased virtual bi-ventricular rat heart models to magnetic resonance imaging and literature data, with model outputs from the constrained parameter space falling within 2 SD of the respective experimental values. The GSA identified Troponin C and cross-bridge kinetics as key parameters in determining both systolic and diastolic ventricular function. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’.