    Field evaluation of a rapid antigen test (Panbio™ COVID-19 Ag Rapid Test Device) for the diagnosis of COVID-19 in primary healthcare centers

    by Eliseo Albert, Ignacio Torres, Felipe Bueno, Dixie Huntley, Estefanía Molla, Miguel Ángel Fernández-Fuentes, Mireia Martínez, Sandrine Poujois, Lorena Forqué, Arantxa Valdivia, et al.

    We evaluated the Panbio™ COVID-19 AG Rapid Test Device (RAD) for the diagnosis of COVID-19 in symptomatic patients attended in primary healthcare centers (n=412). Overall specificity and sensitivity of RAD was 100% and 79.6%, respectively, taking RT-PCR as the reference. SARS-CoV-2 could not be cultured from specimens yielding RT-PCR+/RAD- results.


  • Open Access

    Amplification of human β-glucoronidase gene for appraising the accuracy of negative SARS-CoV-2 RT-PCR results in upper respiratory tract specimens

    by Eliseo Albert, Blanca Ferrer, Ignacio Torres, Alicia Serrano, Maria Jesus Alcaraz, Javier Buesa, Carlos Solnao, Javier Colomina, Felipe Bueno, Dixie Huntley, et al.

    Real-time reverse transcription polymerase-chain reaction (RT-PCR) is the mainstay of Covid-19 diagnosis. False-negative RT-PCR results may hamper clinical management of patients and hinder the adoption of epidemiological measures to control the pandemic. The current study was aimed at assessing whether amplification of β-glucoronidase (GUSB) gene would help estimate the accuracy of SARS-CoV-2 RT-PCR negative results in upper respiratory tract (URT) specimens. URT specimens that tested negative by SARS-CoV-2 RT-PCR displayed higher GUSB RT-PCR cycle thresholds (CT) (P=0.070) than those testing positive (median, 30.7; range, 27.0-40.0, and median 29.7; range 25.5-36.8, respectively), this reflecting poorer cellularity. Receiver operating characteristic (roc) curve analysis indicated that a CT threshold of 31.2 discriminated best between positive and negative SARS CoV-2 RT-PCRs (area under a curve, 0.66; 95% CI, 0.50-0.81; P=0.08). This cut-off yielded a true negative ratio of 89% and accuracy of 70%. The data suggested that amplification of the GUSB gene by RT-PCR may help to appraise the accuracy of negative SARS-CoV-2 RT-PCR results in patients in whom Covid-19 is eventually diagnosed.