Evangelia Chalkiadaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Evangelia Chalkiadaki has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Efthymios Karmiris
Department of Ophthalmology, Airforce General Hospital, Athens, Greece
14 shared publicationsEvangelia Papakonstantinou
Department of Ophthalmology, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
6 shared publicationsIlias Georgalas
Department of Ophthalmology, National and Kapodistrian University of Athens, General Hospital “G. Gennimatas”, Athens, Greece
6 shared publicationsKonstantinos Tsiripidis
Department of Ophthalmology, Airforce General Hospital, Athens, Greece
6 shared publicationsAnastasia Tsiogka
Department of Ophthalmology, General Military Hospital of Athens, Athens, Greece
5 shared publications- Efthymios Karmiris
Second Department of Ophthalmology, School of Medicine, National and Kapodistrian University of Athens, Attikon University Hospital, Haidari, Athens, Greece
5 shared publications
Latest Publications
- 21 April 2026
- Published by BMJ in British Journal of Ophthalmology
Real-world early outcomes of intravitreal faricimab 6-mg and aflibercept 2-mg injection in diabetic macular oedema
Background/aims: To evaluate real-world, short-term anatomical and functional outcomes of faricimab versus aflibercept 2 mg in diabetic macular oedema (DMO). Methods: This retrospective, parallel-cohort comparative study included 300 consecutive patients with DMO from Moorfields Eye Hospital. Eligible eyes were treatment-naïve and treatment-experienced not receiving therapy for ≥6 months and subsequently initiated on loading phase of faricimab or aflibercept 2mg. Follow-up was 4 months. Data were collected from the Moorfields electronic medical records system. Changes in visual acuity (VA) and central subfield thickness (CST) from baseline to the fourth injection were analysed using multiple linear regression adjusted for baseline covariates (age, gender, ethnicity, diabetes type, baseline retinopathy status, baseline VA or CST and treatment interval). Results: Of 300 eyes enrolled, 292 were ultimately analysed (191 aflibercept; 101 faricimab), with 246 eyes (84.2%) completing follow-up. Mean unadjusted VA gain was +3.9±10.4 letters with aflibercept and +5.2±11.8 letters with faricimab. Adjusted marginal mean VA gain was +4.2 letters for aflibercept and +4.7 letters for faricimab, with a non-significant difference of –0.5 letters (p=0.7). Baseline VA and treatment interval were significant predictors of functional response, with baseline VA exerting approximately 3.4 times the impact of treatment interval. Mean CST reduction was 87.3±106.1 µm with aflibercept and 113.1±136.7 µm with faricimab. Adjusted mean reductions were 95.4 µm and 99.8 µm, respectively (difference –4.4 µm, p=0.7). Baseline CST was the only independent predictor of anatomical response. Conclusion: Faricimab and aflibercept achieved comparable short-term anatomical and functional outcomes, with greater anatomical improvement associated with higher baseline CST and larger visual gains observed with lower baseline VA. Treatment interval influenced functional response, underscoring the importance of timely therapy. Baseline disease features and treatment adherence are key determinants of early outcomes, rather than drug selection.
- 21 April 2026
- Published by BMJ in British Journal of Ophthalmology
Real-world early outcomes of intravitreal faricimab 6-mg and aflibercept 2-mg injection in diabetic macular oedema
Background/aims: To evaluate real-world, short-term anatomical and functional outcomes of faricimab versus aflibercept 2 mg in diabetic macular oedema (DMO). Methods: This retrospective, parallel-cohort comparative study included 300 consecutive patients with DMO from Moorfields Eye Hospital. Eligible eyes were treatment-naïve and treatment-experienced not receiving therapy for ≥6 months and subsequently initiated on loading phase of faricimab or aflibercept 2mg. Follow-up was 4 months. Data were collected from the Moorfields electronic medical records system. Changes in visual acuity (VA) and central subfield thickness (CST) from baseline to the fourth injection were analysed using multiple linear regression adjusted for baseline covariates (age, gender, ethnicity, diabetes type, baseline retinopathy status, baseline VA or CST and treatment interval). Results: Of 300 eyes enrolled, 292 were ultimately analysed (191 aflibercept; 101 faricimab), with 246 eyes (84.2%) completing follow-up. Mean unadjusted VA gain was +3.9±10.4 letters with aflibercept and +5.2±11.8 letters with faricimab. Adjusted marginal mean VA gain was +4.2 letters for aflibercept and +4.7 letters for faricimab, with a non-significant difference of –0.5 letters (p=0.7). Baseline VA and treatment interval were significant predictors of functional response, with baseline VA exerting approximately 3.4 times the impact of treatment interval. Mean CST reduction was 87.3±106.1 µm with aflibercept and 113.1±136.7 µm with faricimab. Adjusted mean reductions were 95.4 µm and 99.8 µm, respectively (difference –4.4 µm, p=0.7). Baseline CST was the only independent predictor of anatomical response. Conclusion: Faricimab and aflibercept achieved comparable short-term anatomical and functional outcomes, with greater anatomical improvement associated with higher baseline CST and larger visual gains observed with lower baseline VA. Treatment interval influenced functional response, underscoring the importance of timely therapy. Baseline disease features and treatment adherence are key determinants of early outcomes, rather than drug selection.
- 6 June 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-14
Comparison of intraocular pressure measurements obtained by Goldmann applanation tonometer, corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters
Purpose To assess the agreement among four types of intraocular pressure (IOP) measurements: IOP obtained by Goldmann applanation tonometer (IOP-GAT),IOP obtained by an air-puff tonometer (Nidek NT-510) (IOP-NCT), the non-corrected IOP obtained by the Corneal Visualization Scheimpflug Technology (IOP-Corvis) and the biomechanically corrected IOP obtained by the Corvis ST (bIOP-Corvis) in eyes having undergone myopic refractive surgery and correlate their differences with corneal biomechanical parameters. Methods This prospective, observational study recruited 104 non-glaucomatous, post-myopic refractive surgery eyes. Each patient underwent IOP evaluation via GAT, Nidek NT-510 and Corvis ST. Difference in IOP readings was assessed by ANOVA analysis. Tonometer intermethod agreement was assessed by the Bland–Altman method. The difference between the IOP measurements was correlated against corneal thickness(CCT), age, gender, type of refractive surgery and corneal biomechanics with mixed effects linear regression analysis. Results bIOP-Corvis showed the highest values (14.77 ± 2.3 mmHg), followed by IOP-NCT (13.95 ± 2.6 mmHg), IOP-GAT (13.46 ± 2.9 mmHg) and IOP-Corvis (12.56 ± 3.1 mmHg). There were statistically significant differences in IOP measurements among all the ANOVA pairwise comparisons. Bland Altman analysis revealed a notable bias (all P < 0.01) among bIOP-Corvis and IOP-NCT, bIOP-Corvis and IOP-Corvis, bIOP-Corvis and IOP-GAT, IOP-NCT and IOP-Corvis, IOP-NCT and IOP-GAT and IOP-Corvis and IOP-GAT. We observed a strong correlation of the difference between bIOP-Corvis and IOP-NCT with patient age (P < 0.001), CCT (P < 0.001), of the difference between bIOP-Corvis and IOP-Corvis, with type of refractive surgery (P = 0.012), age (P = 0.050), CCT (P < 0.001), the stiffness parameter at first applanation(SP-A1) (P = 0.008), Ambrozio Relational Thickness horizontal (ARTh) (P < 0.001), of the difference between bIOP-Corvis and IOP-GAT, with CCT (P < 0.001), ARTh (P < 0.001), Deformation Amplitude Ratio (DA Ratio) (P = 0.035), of the difference between IOP-NCT and IOP-Corvis, with type of refractive surgery (P = 0.002), CCT (P = 0.031), SP-A1 (P = 0.014), ARTh (P < 0.001), of the difference between IOP-NCT and IOP-GAT with ARTh (P < 0.001) and of the difference between IOP-Corvis and IOP-GAT with SP-A1 (P = 0.027). Conclusion The different IOP values obtained by Corvis ST, NCT and GAT tonometers do not have a steady relationship in their measurements between them and cannot be considered interchangeable in post-myopic refractive surgery eyes. These differences from each pair of IOP measurements are correlated with corneal biomechanics,CCT and age. Our results suggest that the smaller degree of myopic correction may lead to a lower difference between the tonometers' readings.
- 6 June 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-14
Comparison of intraocular pressure measurements obtained by Goldmann applanation tonometer, corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters
Purpose To assess the agreement among four types of intraocular pressure (IOP) measurements: IOP obtained by Goldmann applanation tonometer (IOP-GAT),IOP obtained by an air-puff tonometer (Nidek NT-510) (IOP-NCT), the non-corrected IOP obtained by the Corneal Visualization Scheimpflug Technology (IOP-Corvis) and the biomechanically corrected IOP obtained by the Corvis ST (bIOP-Corvis) in eyes having undergone myopic refractive surgery and correlate their differences with corneal biomechanical parameters. Methods This prospective, observational study recruited 104 non-glaucomatous, post-myopic refractive surgery eyes. Each patient underwent IOP evaluation via GAT, Nidek NT-510 and Corvis ST. Difference in IOP readings was assessed by ANOVA analysis. Tonometer intermethod agreement was assessed by the Bland–Altman method. The difference between the IOP measurements was correlated against corneal thickness(CCT), age, gender, type of refractive surgery and corneal biomechanics with mixed effects linear regression analysis. Results bIOP-Corvis showed the highest values (14.77 ± 2.3 mmHg), followed by IOP-NCT (13.95 ± 2.6 mmHg), IOP-GAT (13.46 ± 2.9 mmHg) and IOP-Corvis (12.56 ± 3.1 mmHg). There were statistically significant differences in IOP measurements among all the ANOVA pairwise comparisons. Bland Altman analysis revealed a notable bias (all P < 0.01) among bIOP-Corvis and IOP-NCT, bIOP-Corvis and IOP-Corvis, bIOP-Corvis and IOP-GAT, IOP-NCT and IOP-Corvis, IOP-NCT and IOP-GAT and IOP-Corvis and IOP-GAT. We observed a strong correlation of the difference between bIOP-Corvis and IOP-NCT with patient age (P < 0.001), CCT (P < 0.001), of the difference between bIOP-Corvis and IOP-Corvis, with type of refractive surgery (P = 0.012), age (P = 0.050), CCT (P < 0.001), the stiffness parameter at first applanation(SP-A1) (P = 0.008), Ambrozio Relational Thickness horizontal (ARTh) (P < 0.001), of the difference between bIOP-Corvis and IOP-GAT, with CCT (P < 0.001), ARTh (P < 0.001), Deformation Amplitude Ratio (DA Ratio) (P = 0.035), of the difference between IOP-NCT and IOP-Corvis, with type of refractive surgery (P = 0.002), CCT (P = 0.031), SP-A1 (P = 0.014), ARTh (P < 0.001), of the difference between IOP-NCT and IOP-GAT with ARTh (P < 0.001) and of the difference between IOP-Corvis and IOP-GAT with SP-A1 (P = 0.027). Conclusion The different IOP values obtained by Corvis ST, NCT and GAT tonometers do not have a steady relationship in their measurements between them and cannot be considered interchangeable in post-myopic refractive surgery eyes. These differences from each pair of IOP measurements are correlated with corneal biomechanics,CCT and age. Our results suggest that the smaller degree of myopic correction may lead to a lower difference between the tonometers' readings.
- 15 April 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (5) , 1604-1613
IOP changes and correlation with alterations in corneal biomechanics and time of useful consciousness following controlled hypobaric hypoxic exposure
Purpose: To evaluate changes in intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanics before and after exposure to hypobaric hypoxia, accounting also for Time of Useful Consciousness (TUC) as a parameter of short time exposure to systemic hypoxia. Methods: This prospective, observational study recruited 45 healthy individuals training in Hypobaric Chamber. IOP, CCT and corneal biomechanics were evaluated before and immediately after the end using the Corvis ST. Comparisons of score values before and after hypoxia were performed with paired t-test for normally distributed differences. Difference between the IOP measurements was correlated with differences in CCT, corneal biomechanics and TUC with multivariate mixed effect linear regression models. Results: Biomechanically corrected IOP (bIOP-Corvis) and pneumotonometry IOP as produced by Corvis ST (NCT) showed statistically significant higher values before hypoxia ( p = 0.048 and p = 0.047 respectively). We observed a strong negative correlation of the difference between bIOP-Corvis before and after hypoxia with the difference in Deformation amplitude ratio (DARatio) ( p < 0.001) and a significant positive correlation with the difference in Integrated Inverse Radius(IntegrRadius) ( p = 0.01), Stiffness parameter at the first applanation (SPA1) ( p < 0.001) and TUC ( p = 0.023). We observed a strong negative correlation of the difference between NCT before and after hypoxia with the difference in DARatio ( p < 0.001) and a significant positive correlation with the difference in IntegrRadius ( p = 0.023), SPA1 ( p < 0.001) and TUC ( p = 0.025). The R-squared values of the regression models were 0.6420 and 0.6626 for the bIOP and NCT respectively. Conclusion: We demonstrated reduction in IOP after hypoxia exposure. A combination of alterations in corneal biomechanics explain a degree of this IOP reduction, whereas CCT did not have a significant role in IOP changes.TUC was found to significantly correlate with IOP changes.
- 15 April 2025
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 35 (5) , 1604-1613
IOP changes and correlation with alterations in corneal biomechanics and time of useful consciousness following controlled hypobaric hypoxic exposure
Purpose: To evaluate changes in intraocular pressure (IOP), central corneal thickness (CCT) and corneal biomechanics before and after exposure to hypobaric hypoxia, accounting also for Time of Useful Consciousness (TUC) as a parameter of short time exposure to systemic hypoxia. Methods: This prospective, observational study recruited 45 healthy individuals training in Hypobaric Chamber. IOP, CCT and corneal biomechanics were evaluated before and immediately after the end using the Corvis ST. Comparisons of score values before and after hypoxia were performed with paired t-test for normally distributed differences. Difference between the IOP measurements was correlated with differences in CCT, corneal biomechanics and TUC with multivariate mixed effect linear regression models. Results: Biomechanically corrected IOP (bIOP-Corvis) and pneumotonometry IOP as produced by Corvis ST (NCT) showed statistically significant higher values before hypoxia ( p = 0.048 and p = 0.047 respectively). We observed a strong negative correlation of the difference between bIOP-Corvis before and after hypoxia with the difference in Deformation amplitude ratio (DARatio) ( p < 0.001) and a significant positive correlation with the difference in Integrated Inverse Radius(IntegrRadius) ( p = 0.01), Stiffness parameter at the first applanation (SPA1) ( p < 0.001) and TUC ( p = 0.023). We observed a strong negative correlation of the difference between NCT before and after hypoxia with the difference in DARatio ( p < 0.001) and a significant positive correlation with the difference in IntegrRadius ( p = 0.023), SPA1 ( p < 0.001) and TUC ( p = 0.025). The R-squared values of the regression models were 0.6420 and 0.6626 for the bIOP and NCT respectively. Conclusion: We demonstrated reduction in IOP after hypoxia exposure. A combination of alterations in corneal biomechanics explain a degree of this IOP reduction, whereas CCT did not have a significant role in IOP changes.TUC was found to significantly correlate with IOP changes.
- Open Access
- 27 February 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (4) , 773-786
The Impact of Disease Activity Criteria on Extending Injection Intervals in Real-World Patients with Neovascular Age-Related Macular Degeneration
Introduction In clinical practice, intravitreal anti-vascular endothelial growth factor (anti-VEGF) injection intervals for patients with neovascular age-related macular degeneration (nAMD) are based on disease activity, with active or recurrent disease requiring more frequent injections. Injection interval modification criteria differ from those used in clinical trials, thereby potentially affecting treatment outcomes. This analysis evaluated the potential impact of applying disease activity criteria from recent clinical trials (TENAYA/LUCERNE; HAWK/HARRIER; PULSAR) on the decision to extend injection intervals in real-world patients commenced on faricimab after the loading phase of treatment and at 12 months. Methods Data were analysed from 105 treatment-naïve patients with nAMD who received anti-VEGF injections at Moorfields Eye Hospital. Disease activity criteria from TENAYA/LUCERNE, HAWK/HARRIER and PULSAR clinical trials were applied to determine the hypothetical impact on the decision to modify injection intervals at week 12 (fourth injection) and 12-month real-world clinic visits. Results At 12 weeks, 79% of patients had injection intervals extended in clinical practice compared to 80% when applying hypothetical TENAYA/LUCERNE disease activity criteria; 77% using HAWK/HARRIER and 96% using PULSAR. There was agreement between clinical practice and all clinical trials in 60% of eyes, and no agreement in 13%. At 12 months, fewer patients were inactive, with 55% of eyes quiescent in clinical practice, 58% when applying TENAYA/LUCERNE criteria and 67% using HAWK/HARRIER. Application of PULSAR disease activity criteria showed 96% of patients were classed as inactive. 34% of eyes showed agreement in disease activity status between clinical practice and all clinical trials at 12 months, with no agreement in 20%. Conclusions Applying disease activity criteria from clinical trials to clinical practice can have a significant impact on hypothetical anti-VEGF injection intervals. Consideration should be paid to which criteria are used in real-world practice to help achieve treatment burden reductions and optimal treatment outcomes seen in clinical trials.
- 27 February 2025
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (4) , 773-786
Open AccessThe Impact of Disease Activity Criteria on Extending Injection Intervals in Real-World Patients with Neovascular Age-Related Macular Degeneration
Introduction In clinical practice, intravitreal anti-vascular endothelial growth factor (anti-VEGF) injection intervals for patients with neovascular age-related macular degeneration (nAMD) are based on disease activity, with active or recurrent disease requiring more frequent injections. Injection interval modification criteria differ from those used in clinical trials, thereby potentially affecting treatment outcomes. This analysis evaluated the potential impact of applying disease activity criteria from recent clinical trials (TENAYA/LUCERNE; HAWK/HARRIER; PULSAR) on the decision to extend injection intervals in real-world patients commenced on faricimab after the loading phase of treatment and at 12 months. Methods Data were analysed from 105 treatment-naïve patients with nAMD who received anti-VEGF injections at Moorfields Eye Hospital. Disease activity criteria from TENAYA/LUCERNE, HAWK/HARRIER and PULSAR clinical trials were applied to determine the hypothetical impact on the decision to modify injection intervals at week 12 (fourth injection) and 12-month real-world clinic visits. Results At 12 weeks, 79% of patients had injection intervals extended in clinical practice compared to 80% when applying hypothetical TENAYA/LUCERNE disease activity criteria; 77% using HAWK/HARRIER and 96% using PULSAR. There was agreement between clinical practice and all clinical trials in 60% of eyes, and no agreement in 13%. At 12 months, fewer patients were inactive, with 55% of eyes quiescent in clinical practice, 58% when applying TENAYA/LUCERNE criteria and 67% using HAWK/HARRIER. Application of PULSAR disease activity criteria showed 96% of patients were classed as inactive. 34% of eyes showed agreement in disease activity status between clinical practice and all clinical trials at 12 months, with no agreement in 20%. Conclusions Applying disease activity criteria from clinical trials to clinical practice can have a significant impact on hypothetical anti-VEGF injection intervals. Consideration should be paid to which criteria are used in real-world practice to help achieve treatment burden reductions and optimal treatment outcomes seen in clinical trials.
- Open Access
- 14 August 2024
- Published by International Virtual Ophthalmic Research Center in Medical hypothesis discovery and innovation in ophthalmology
- Vol. 13 (2) , 70-75
Corneal and anterior segment parameters in patients with clinically unilateral pseudoexfoliation syndrome
Background: Pseudoexfoliation syndrome (PES) is an age-related systemic condition that predominantly affects ocular structures and is characterized by the deposition of material on the lens, ciliary body, zonules, corneal endothelium, iris, and pupillary margin. We compared the corneal endothelial morphology, anterior segment parameters, corneal densitometry, and corneal topographic characteristics between the clinically affected and apparently normal fellow eyes of patients with clinically unilateral PES. Methods: This was a comparative, cross-sectional study of 34 patients with clinically unilateral PES. The anterior segment was examined using a Scheimpflug imaging system, and the corneal endothelium was assessed using a noncontact specular microscope. Corneal endothelial cell density, polymegathism, and pleomorphism were assessed using the specular microscope. Furthermore, the Scheimpflug camera was used to measure the corneal power of the flat and steep axis, mean corneal power, maximum keratometry, anterior chamber angle, anterior chamber depth, anterior chamber volume, corneal volume, and the corneal thickness at the apex point, center of the pupil, and the thinnest point. Corneal densitometry was evaluated at two concentric zones (0–2 mm and 0–12 mm). Results: In total, 68 eyes from 34 patients were ultimately included in the study. The mean (standard deviation) age of the patients was 73.38 (8.75) years (range: 50–87 years). Among the included patients, 17 (50%) were male and 17 (50%) were female. The anterior segment parameters did not significantly differ between eyes with PES and their clinically unaffected fellow eyes (all P > 0.05). Similarly, no statistically significant difference was observed in corneal endothelial morphology (all P > 0.05). Conclusions: Our measured parameters do not differ between the clinically affected eye and the clinically unaffected fellow eye. This supports the theory that PES is a bilateral disorder. Considering the variety of complications associated with PES, bilateral involvement should be assumed in the clinical and surgical management of patients with clinically unilateral PES. In the future, new research could increase our understanding of this syndrome.
- 14 August 2024
- Published by International Virtual Ophthalmic Research Center in Medical hypothesis discovery and innovation in ophthalmology
- Vol. 13 (2) , 70-75
Open AccessCorneal and anterior segment parameters in patients with clinically unilateral pseudoexfoliation syndrome
Background: Pseudoexfoliation syndrome (PES) is an age-related systemic condition that predominantly affects ocular structures and is characterized by the deposition of material on the lens, ciliary body, zonules, corneal endothelium, iris, and pupillary margin. We compared the corneal endothelial morphology, anterior segment parameters, corneal densitometry, and corneal topographic characteristics between the clinically affected and apparently normal fellow eyes of patients with clinically unilateral PES. Methods: This was a comparative, cross-sectional study of 34 patients with clinically unilateral PES. The anterior segment was examined using a Scheimpflug imaging system, and the corneal endothelium was assessed using a noncontact specular microscope. Corneal endothelial cell density, polymegathism, and pleomorphism were assessed using the specular microscope. Furthermore, the Scheimpflug camera was used to measure the corneal power of the flat and steep axis, mean corneal power, maximum keratometry, anterior chamber angle, anterior chamber depth, anterior chamber volume, corneal volume, and the corneal thickness at the apex point, center of the pupil, and the thinnest point. Corneal densitometry was evaluated at two concentric zones (0–2 mm and 0–12 mm). Results: In total, 68 eyes from 34 patients were ultimately included in the study. The mean (standard deviation) age of the patients was 73.38 (8.75) years (range: 50–87 years). Among the included patients, 17 (50%) were male and 17 (50%) were female. The anterior segment parameters did not significantly differ between eyes with PES and their clinically unaffected fellow eyes (all P > 0.05). Similarly, no statistically significant difference was observed in corneal endothelial morphology (all P > 0.05). Conclusions: Our measured parameters do not differ between the clinically affected eye and the clinically unaffected fellow eye. This supports the theory that PES is a bilateral disorder. Considering the variety of complications associated with PES, bilateral involvement should be assumed in the clinical and surgical management of patients with clinically unilateral PES. In the future, new research could increase our understanding of this syndrome.
- Top Cited Papers
- 30 July 2024
- Published by Elsevier in Ophthalmology Retina
- Vol. 9 (1) , 22-30
Real-World 1-Year Outcomes of Treatment-Intensive Neovascular Age-Related Macular Degeneration Switched to Faricimab
- 30 July 2024
- Published by Elsevier in Ophthalmology Retina
- Vol. 9 (1) , 22-30
Top Cited PapersReal-World 1-Year Outcomes of Treatment-Intensive Neovascular Age-Related Macular Degeneration Switched to Faricimab
- 25 June 2024
- Published by Taylor & Francis in Ocular Immunology and Inflammation
- Vol. 32 (10) , 2558-2561
An Atypical Case of Severe Toxicity, Anterior Chamber Inflammation, and Transient Subretinal Fluid Formation Induced by the Subconjunctival Injection of 5-FU
PurposeTo report an atypical presentation of severe toxicity, anterior chamber (AC) inflammation, and transient parafoveal formation of subretinal fluid induced by the subconjunctival injection of 5-fluorouracil (5-FU).MethodsCase presentation.ResultsSeven weeks after trabeculectomy, a 40-year-old white male had a subconjunctival injection of 5-FU. Within minutes after the injection, the lens turned grey and then total white. Initially, AC was clear, and 20 min later, a severe AC reaction was detected. The patient was prescribed hourly dexamethasone eye drops and tropicamide eye drops twice daily. Two days post-injection, vision improved, AC reaction was minimal, and there was whitish fibrinous material on the anterior surface of the lens, extending up to the pupillary margin. Minimal posterior synechiae were observed, and upon dilation, the remainder of the anterior surface of the lens appeared completely clear, indicating that only the portion of the lens not covered by the iris exhibited fibrinous material and deposits. One week post-injection, vision worsened due to severe corneal toxicity. The dimensions of the whitish fibrinous material on the anterior lens capsule decreased, and macular scans revealed parafoveal subretinal fluid. Two weeks later, vision significantly improved, and the dimensions of the whitish fibrinous material on the anterior lens capsule were further decreased. The subretinal fluid had completely resolved.ConclusionWe describe a rare case of severe toxicity, AC inflammation, and transient parafoveal subretinal fluid formation caused by the 5-FU. This was treated with topical steroid treatment, and eventually some level of lens opacification persisted despite significant clearance of the AC inflammation.
- 25 June 2024
- Published by Taylor & Francis in Ocular Immunology and Inflammation
- Vol. 32 (10) , 2558-2561
An Atypical Case of Severe Toxicity, Anterior Chamber Inflammation, and Transient Subretinal Fluid Formation Induced by the Subconjunctival Injection of 5-FU
PurposeTo report an atypical presentation of severe toxicity, anterior chamber (AC) inflammation, and transient parafoveal formation of subretinal fluid induced by the subconjunctival injection of 5-fluorouracil (5-FU).MethodsCase presentation.ResultsSeven weeks after trabeculectomy, a 40-year-old white male had a subconjunctival injection of 5-FU. Within minutes after the injection, the lens turned grey and then total white. Initially, AC was clear, and 20 min later, a severe AC reaction was detected. The patient was prescribed hourly dexamethasone eye drops and tropicamide eye drops twice daily. Two days post-injection, vision improved, AC reaction was minimal, and there was whitish fibrinous material on the anterior surface of the lens, extending up to the pupillary margin. Minimal posterior synechiae were observed, and upon dilation, the remainder of the anterior surface of the lens appeared completely clear, indicating that only the portion of the lens not covered by the iris exhibited fibrinous material and deposits. One week post-injection, vision worsened due to severe corneal toxicity. The dimensions of the whitish fibrinous material on the anterior lens capsule decreased, and macular scans revealed parafoveal subretinal fluid. Two weeks later, vision significantly improved, and the dimensions of the whitish fibrinous material on the anterior lens capsule were further decreased. The subretinal fluid had completely resolved.ConclusionWe describe a rare case of severe toxicity, AC inflammation, and transient parafoveal subretinal fluid formation caused by the 5-FU. This was treated with topical steroid treatment, and eventually some level of lens opacification persisted despite significant clearance of the AC inflammation.
- 11 April 2024
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (4) , NP29-NP32
Atypical phacolytic glaucoma diagnosed by biometry and anterior segment optical coherence tomography (OCT) in a patient with CMV anterior uveitis
Purpose: To report a case of phacolytic glaucoma with atypical presentation in a patient which was diagnosed with biometry swept source optical coherence tomography (SS-OCT) and anterior segment spectral domain OCT (SD-OCT). Methods: A 56-year-old male with a history of cytomegalovirus (CMV) chronic anterior uveitis in the right eye presented with a white cataract, minimal anterior chamber reaction and intraocular pressure (IOP) of 56 mmHg. Visual acuity was light perception. The anterior chamber was deep, without evidence of macroscopically visible capsular rupture. A surgical intervention was necessitated with the puzzle being whether to proceed with a trabeculectomy or a combined phaco-trabeculectomy. After a routine preoperative assessment with intraocular lens Master700, the disintegration of the natural lens was noticed. Anterior segment Spectralis OCT confirmed a lamellar separation of the anterior one third of the lens, resembling a poultaceous material. After an uneventful phacoemulsification, visual acuity was 6/6, IOP was well-controlled on maximum topical antiglaucoma treatment and no CMV recurrence was observed. Results: The diagnosis of phacolytic glaucoma was established with the aid of current imaging OCT systems. Both OCT images were suggestive of a phacolytic nature of our case, despite the fact that the clinical presentation was not in concordance with such a typical case. In view of our findings the decision was to proceed with cataract extraction alone. Conclusion: This is the first time that we image and document the phacolytic nature of a natural lens. Our patient did not have the typical clinical presentation and was differentially diagnosed with biometry SS-OCT and confirmed by anterior segment SD-OCT.
- 11 April 2024
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (4) , NP29-NP32
Atypical phacolytic glaucoma diagnosed by biometry and anterior segment optical coherence tomography (OCT) in a patient with CMV anterior uveitis
Purpose: To report a case of phacolytic glaucoma with atypical presentation in a patient which was diagnosed with biometry swept source optical coherence tomography (SS-OCT) and anterior segment spectral domain OCT (SD-OCT). Methods: A 56-year-old male with a history of cytomegalovirus (CMV) chronic anterior uveitis in the right eye presented with a white cataract, minimal anterior chamber reaction and intraocular pressure (IOP) of 56 mmHg. Visual acuity was light perception. The anterior chamber was deep, without evidence of macroscopically visible capsular rupture. A surgical intervention was necessitated with the puzzle being whether to proceed with a trabeculectomy or a combined phaco-trabeculectomy. After a routine preoperative assessment with intraocular lens Master700, the disintegration of the natural lens was noticed. Anterior segment Spectralis OCT confirmed a lamellar separation of the anterior one third of the lens, resembling a poultaceous material. After an uneventful phacoemulsification, visual acuity was 6/6, IOP was well-controlled on maximum topical antiglaucoma treatment and no CMV recurrence was observed. Results: The diagnosis of phacolytic glaucoma was established with the aid of current imaging OCT systems. Both OCT images were suggestive of a phacolytic nature of our case, despite the fact that the clinical presentation was not in concordance with such a typical case. In view of our findings the decision was to proceed with cataract extraction alone. Conclusion: This is the first time that we image and document the phacolytic nature of a natural lens. Our patient did not have the typical clinical presentation and was differentially diagnosed with biometry SS-OCT and confirmed by anterior segment SD-OCT.
- 13 March 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 43 (6) , 764-770
Correlations of Corneal Endothelial Morphology and Corneal Thickness With Anterior Segment Parameters in Healthy Individuals
Purpose: The purpose of this study was to investigate the associations between central corneal endothelial cell density (ECD), endothelial morphology, and corneal thickness (central corneal thickness) with the anterior chamber depth, corneal volume (CV), white-to-white (WTW) distance, mean anterior chamber angle (CAmean), and gender in healthy individuals. Methods: This observational study included 136 healthy volunteers. The ECD, coefficient of variation of cell area, and hexagonal cell appearance ratio (%Hex) were measured by means of specular microscopy. The central corneal thickness, anterior chamber depth, CV, WTW distance, and the angle width of 12 points were taken by the Pentacam HR Scheimpflug anterior segment imaging. The arithmetical mean of the 12 points was considered as the CAmean. We used mixed effect linear regression model for the statistical analysis of the data. Results: ECD was positively correlated with CV (P = 0.028), while after adjusting for age, it was negatively correlated with age (P < 0.001). Coefficient of variation of cell area was positively correlated with CAmean (P = 0.036), while after adjusting for age, it was positively correlated with age (P < 0.001) and CAmean (P = 0.005). Hex was negatively correlated with WTW (P = 0.023) and CAmean (P = 0.025), and after adjusting for age, this correlation remained the same (P = 0.029 when correlated with WTW and P = 0.035 with CAmean). Conclusions: There were significant changes in the morphology of the corneal endothelial cells in eyes with wider anterior chamber angle. Greater pleomorphism and polymegethism of the corneal endothelium was observed in healthy patients with wider CAmean. Deepening of the anterior chamber as myopia progresses could render the corneal endothelium more fragile and susceptible to mechanical stress, which is an area worthy of further study.
- 13 March 2024
- Published by Wolters Kluwer Health in Cornea
- Vol. 43 (6) , 764-770
Correlations of Corneal Endothelial Morphology and Corneal Thickness With Anterior Segment Parameters in Healthy Individuals
Purpose: The purpose of this study was to investigate the associations between central corneal endothelial cell density (ECD), endothelial morphology, and corneal thickness (central corneal thickness) with the anterior chamber depth, corneal volume (CV), white-to-white (WTW) distance, mean anterior chamber angle (CAmean), and gender in healthy individuals. Methods: This observational study included 136 healthy volunteers. The ECD, coefficient of variation of cell area, and hexagonal cell appearance ratio (%Hex) were measured by means of specular microscopy. The central corneal thickness, anterior chamber depth, CV, WTW distance, and the angle width of 12 points were taken by the Pentacam HR Scheimpflug anterior segment imaging. The arithmetical mean of the 12 points was considered as the CAmean. We used mixed effect linear regression model for the statistical analysis of the data. Results: ECD was positively correlated with CV (P = 0.028), while after adjusting for age, it was negatively correlated with age (P < 0.001). Coefficient of variation of cell area was positively correlated with CAmean (P = 0.036), while after adjusting for age, it was positively correlated with age (P < 0.001) and CAmean (P = 0.005). Hex was negatively correlated with WTW (P = 0.023) and CAmean (P = 0.025), and after adjusting for age, this correlation remained the same (P = 0.029 when correlated with WTW and P = 0.035 with CAmean). Conclusions: There were significant changes in the morphology of the corneal endothelial cells in eyes with wider anterior chamber angle. Greater pleomorphism and polymegethism of the corneal endothelium was observed in healthy patients with wider CAmean. Deepening of the anterior chamber as myopia progresses could render the corneal endothelium more fragile and susceptible to mechanical stress, which is an area worthy of further study.
- Open Access
- 24 January 2024
- Published by Springer Nature in Research Square
Comparison of Intraocular Pressure measurements obtained by Goldmann Applanation Tonometer, Corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters
Purpose To assess the agreement among four types of intraocular pressure (IOP) measurements: IOP obtained by Goldmann applanation tonometer (IOP-GAT),IOP obtained by an air-puff tonometer (Nidek NT-510) (IOP-NCT), the non-corrected IOP obtained by the Corneal Visualization Scheimpflug Technology (IOP-Corvis) and the biomechanically corrected IOP obtained by the Corvis ST (bIOP-Corvis) in eyes having undergone myopic refractive surgery and correlate their differences with corneal biomechanical parameters. Methods This prospective, observational study recruited 104 post-myopic refractive surgery eyes. Each patient underwent IOP evaluation via GAT, Nidek NT-510 and Corvis ST. Difference in IOP readings was assessed by ANOVA analysis. Tonometer intermethod agreement was assessed by the Bland-Altman method. The difference between the IOP measurements was correlated against corneal thickness(CCT), age, gender, type of refractive surgery and corneal biomechanics with mixed effects linear regression analysis. Results bIOP-Corvis showed the highest values (14.77 ± 2.3mmHg), followed by IOP-NCT (13.95 ± 2.6mmHg), IOP-GAT (13.46 ± 2.9mmHg) and IOP-Corvis (12.56 ± 3.1mmHg). There were statistically significant differences in IOP measurements among all the ANOVA pairwise comparisons. Bland Altman analysis revealed a notable bias (all p < 0.01) among bIOP-Corvis and IOP-NCT, bIOP-Corvis and IOP-Corvis, bIOP-Corvis and IOP-GAT, IOP-NCT and IOP-Corvis, IOP-NCT and IOP-GAT and IOP-Corvis and IOP-GAT. We observed a strong correlation of the difference between bIOP-Corvis and IOP-NCT with patient age (p < 0.001), CCT (p < 0.001), of the difference between bIOP-Corvis and IOP-Corvis, with type of refractive surgery (p = 0.012), age(p = 0.050), CCT(p < 0.001), the stiffness parameter at first applanation(SP-A1) (p = 0.008), Ambrozio Relational Thickness horizontal (ARTh) (p < 0.001), of the difference between bIOP-Corvis and IOP-GAT, with CCT (p < 0.001), ARTh (p < 0.001), Deformation Amplitude Ratio (DA Ratio) (p = 0.035), of the difference between IOP-NCT and IOP-Corvis, with type of refractive surgery (p = 0.002), CCT (p = 0.031), SP-A1 (p = 0.014), ARTh (p < 0.001), of the difference between IOP-NCT and IOP-GAT with ARTh (p < 0.001) and of the difference between IOP-Corvis and IOP-GAT with SP-A1 (p = 0.027). Conclusion The different IOP values obtained by Corvis ST, NCT and GAT tonometers do not have a steady relationship in their measurements between them and as a result cannot be considered interchangeable in post-myopic refractive surgery eyes. These differences from each couple of IOP measurements are correlated with corneal biomechanics,CCT and age. Our results can arguably speculate that the smaller the degree of myopic correction the lower the difference between the tonometer’s readings.
- 24 January 2024
- Published by Springer Nature in Research Square
Open AccessComparison of Intraocular Pressure measurements obtained by Goldmann Applanation Tonometer, Corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters
Purpose To assess the agreement among four types of intraocular pressure (IOP) measurements: IOP obtained by Goldmann applanation tonometer (IOP-GAT),IOP obtained by an air-puff tonometer (Nidek NT-510) (IOP-NCT), the non-corrected IOP obtained by the Corneal Visualization Scheimpflug Technology (IOP-Corvis) and the biomechanically corrected IOP obtained by the Corvis ST (bIOP-Corvis) in eyes having undergone myopic refractive surgery and correlate their differences with corneal biomechanical parameters. Methods This prospective, observational study recruited 104 post-myopic refractive surgery eyes. Each patient underwent IOP evaluation via GAT, Nidek NT-510 and Corvis ST. Difference in IOP readings was assessed by ANOVA analysis. Tonometer intermethod agreement was assessed by the Bland-Altman method. The difference between the IOP measurements was correlated against corneal thickness(CCT), age, gender, type of refractive surgery and corneal biomechanics with mixed effects linear regression analysis. Results bIOP-Corvis showed the highest values (14.77 ± 2.3mmHg), followed by IOP-NCT (13.95 ± 2.6mmHg), IOP-GAT (13.46 ± 2.9mmHg) and IOP-Corvis (12.56 ± 3.1mmHg). There were statistically significant differences in IOP measurements among all the ANOVA pairwise comparisons. Bland Altman analysis revealed a notable bias (all p < 0.01) among bIOP-Corvis and IOP-NCT, bIOP-Corvis and IOP-Corvis, bIOP-Corvis and IOP-GAT, IOP-NCT and IOP-Corvis, IOP-NCT and IOP-GAT and IOP-Corvis and IOP-GAT. We observed a strong correlation of the difference between bIOP-Corvis and IOP-NCT with patient age (p < 0.001), CCT (p < 0.001), of the difference between bIOP-Corvis and IOP-Corvis, with type of refractive surgery (p = 0.012), age(p = 0.050), CCT(p < 0.001), the stiffness parameter at first applanation(SP-A1) (p = 0.008), Ambrozio Relational Thickness horizontal (ARTh) (p < 0.001), of the difference between bIOP-Corvis and IOP-GAT, with CCT (p < 0.001), ARTh (p < 0.001), Deformation Amplitude Ratio (DA Ratio) (p = 0.035), of the difference between IOP-NCT and IOP-Corvis, with type of refractive surgery (p = 0.002), CCT (p = 0.031), SP-A1 (p = 0.014), ARTh (p < 0.001), of the difference between IOP-NCT and IOP-GAT with ARTh (p < 0.001) and of the difference between IOP-Corvis and IOP-GAT with SP-A1 (p = 0.027). Conclusion The different IOP values obtained by Corvis ST, NCT and GAT tonometers do not have a steady relationship in their measurements between them and as a result cannot be considered interchangeable in post-myopic refractive surgery eyes. These differences from each couple of IOP measurements are correlated with corneal biomechanics,CCT and age. Our results can arguably speculate that the smaller the degree of myopic correction the lower the difference between the tonometer’s readings.