Ki Chang Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ki Chang Kang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Kwan Kyu Park
Department of Convergence Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea
5 shared publications - Young Hun Kim
Department of Convergence Mechanical Engineering, Hanyang University, Seoul 04763, Korea
3 shared publications Burtus T. Khuri-Yakub
E. L. Ginzton Lab, Dept. of Electrical Engineering, Stanford University, Stanford, CA, USA
2 shared publications- Changjin Lee
Chonnam National University, Gwangju, South Korea
1 shared publication Do Yeong Joung
Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
1 shared publication- Gi Yoon Bae
Department of Electronic Engineering, Hanyang University, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 5 April 2023
- Published by Elsevier in Ultrasonics
- Vol. 132, 107003
Measurement of the acoustic reflectance function based on Lamb wave using high f-number transducers
- 5 April 2023
- Published by Elsevier in Ultrasonics
- Vol. 132, 107003
Open AccessMeasurement of the acoustic reflectance function based on Lamb wave using high f-number transducers
- 1 March 2022
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 151 (3) , 2159-2170
Increasing the transmission efficiency of transcranial ultrasound using a dual-mode conversion technique based on Lamb waves
Transcranial focused ultrasound (FUS) is a noninvasive treatment for brain tumors and neuromodulation. Based on normal incidence, conventional FUS techniques use a focused or an array of ultrasonic transducers to overcome the attenuation and absorption of ultrasound in the skull; however, this remains the main limitation of using FUS. A dual-mode conversion technique based on Lamb waves is proposed to achieve high transmission efficiency. This concept was validated using the finite element analysis (FEA) and experiments based on changes in the incident angle. Aluminum, plexiglass, and a human skull were used as materials with different attenuations. The transmission loss was calculated for each material, and the results were compared with the reflectance function of the Lamb waves. Oblique incidence based on dual-mode conversion exhibited a better transmission efficiency than that of a normal incidence for all of the specimens. The total transmission losses for the materials were 13.7, 15.46, and 3.91 dB less than those associated with the normal incidence. A wedge transducer was designed and fabricated to implement the proposed method. The results demonstrated the potential applicability of the dual-mode conversion technique for the human skull.
- 1 March 2022
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 151 (3) , 2159-2170
Increasing the transmission efficiency of transcranial ultrasound using a dual-mode conversion technique based on Lamb waves
Transcranial focused ultrasound (FUS) is a noninvasive treatment for brain tumors and neuromodulation. Based on normal incidence, conventional FUS techniques use a focused or an array of ultrasonic transducers to overcome the attenuation and absorption of ultrasound in the skull; however, this remains the main limitation of using FUS. A dual-mode conversion technique based on Lamb waves is proposed to achieve high transmission efficiency. This concept was validated using the finite element analysis (FEA) and experiments based on changes in the incident angle. Aluminum, plexiglass, and a human skull were used as materials with different attenuations. The transmission loss was calculated for each material, and the results were compared with the reflectance function of the Lamb waves. Oblique incidence based on dual-mode conversion exhibited a better transmission efficiency than that of a normal incidence for all of the specimens. The total transmission losses for the materials were 13.7, 15.46, and 3.91 dB less than those associated with the normal incidence. A wedge transducer was designed and fabricated to implement the proposed method. The results demonstrated the potential applicability of the dual-mode conversion technique for the human skull.
- Open Access
Noncontact Laser Ultrasound Detection of Cracks Using Hydrophone
We present a noncontact, non-immersion ultrasonic inspection method. A broadband ultrasound signal generated by a pulsed laser was measured using a hydrophone. The generated ultrasound signals propagated through the specimen and received a signal from the hydrophone in the water. Soldered chip ceramic capacitors, resistors, and surface-mount-type chip amplifiers were used as experimental specimens. A polydimethylsiloxane layer was used to prevent the specimen from being impacted by contact with water. The presence of a crack in the middle of the specimen resulted in an air layer, and the intermediate air layer reduced the magnitude of the signal transmitted owing to impedance mismatch. Using this principle, the cracks in each specimen could be distinguished. The image contrast ratio derived from the proposed method is approximately two to three times higher than that derived using the conventional immersion ultrasonic method. These results show that the proposed method can replace existing immersion-type ultrasound transmitted images.
Open AccessNoncontact Laser Ultrasound Detection of Cracks Using Hydrophone
We present a noncontact, non-immersion ultrasonic inspection method. A broadband ultrasound signal generated by a pulsed laser was measured using a hydrophone. The generated ultrasound signals propagated through the specimen and received a signal from the hydrophone in the water. Soldered chip ceramic capacitors, resistors, and surface-mount-type chip amplifiers were used as experimental specimens. A polydimethylsiloxane layer was used to prevent the specimen from being impacted by contact with water. The presence of a crack in the middle of the specimen resulted in an air layer, and the intermediate air layer reduced the magnitude of the signal transmitted owing to impedance mismatch. Using this principle, the cracks in each specimen could be distinguished. The image contrast ratio derived from the proposed method is approximately two to three times higher than that derived using the conventional immersion ultrasonic method. These results show that the proposed method can replace existing immersion-type ultrasound transmitted images.
- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (6) , 1151-1158
Single-Shot Near-Field Volumetric Imaging System for Optical Ultrasound and Photoacoustics Using Capacitive Micromachined Ultrasonic Transducer Without Transmission Mode
In this paper, we present a single-shot dual-mode imaging system that uses optical ultrasound (US) as an ultrasonic pulser; thus without transmission circuit. The ultrasonic pulse-echo system comprises an optical US pulser generated by carbon nanotubes (CNTs), which generate a high-power photoacoustic (PA) signal, and a capacitive micromachined ultrasonic transducer (CMUT) receiver. By fabricating a thin CNT-polydimethylsiloxane (PDMS) composite capable of semi-absorption of the laser, a single-shot imaging system was developed. By transmitting semi-penetration light to the object, US and PA imaging were performed in a single shot. A CNT thickness of <1 μm produced a maximum pressure of 154 kPa, and US was received by the CMUT with a 2-MHz center frequency in the PDMS. Additionally, a low-profile and near-depth imaging system was constructed with an intermediate layer of 6-mm PDMS for the dry contact method. We performed a single-shot dual-mode imaging experiment on point and line phantoms, as well as the particle spread in soft tissue. Thus, we examined the feasibility of the near-depth and single-shot dual-mode (US and PA) imaging system capable of dry contact.
- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (6) , 1151-1158
Single-Shot Near-Field Volumetric Imaging System for Optical Ultrasound and Photoacoustics Using Capacitive Micromachined Ultrasonic Transducer Without Transmission Mode
In this paper, we present a single-shot dual-mode imaging system that uses optical ultrasound (US) as an ultrasonic pulser; thus without transmission circuit. The ultrasonic pulse-echo system comprises an optical US pulser generated by carbon nanotubes (CNTs), which generate a high-power photoacoustic (PA) signal, and a capacitive micromachined ultrasonic transducer (CMUT) receiver. By fabricating a thin CNT-polydimethylsiloxane (PDMS) composite capable of semi-absorption of the laser, a single-shot imaging system was developed. By transmitting semi-penetration light to the object, US and PA imaging were performed in a single shot. A CNT thickness of <1 μm produced a maximum pressure of 154 kPa, and US was received by the CMUT with a 2-MHz center frequency in the PDMS. Additionally, a low-profile and near-depth imaging system was constructed with an intermediate layer of 6-mm PDMS for the dry contact method. We performed a single-shot dual-mode imaging experiment on point and line phantoms, as well as the particle spread in soft tissue. Thus, we examined the feasibility of the near-depth and single-shot dual-mode (US and PA) imaging system capable of dry contact.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1571-1574
Non-contact leaky Lamb wave imaging based on pulsed laser and ultrasound microphone
A local wavenumber estimation (LWE) method based on a scanning laser Doppler vibrometer (SLDV) is derived using a frequency-wavenumber domain filtering method. LWE methods based on a standing wave have recently been investigated. This technique utilizes SLDV data in the steady-state excitation of a fixed frequency. Despite its various advantages, the LWE method uses contact actuators to provide sufficient vibrating energy. In this study, we solved the cost and complexity problems of using SLDV by replacing it with an ultrasound microphone. We also measured the shallow defect of an aluminum plate using a noncontact-LWE method. A Nd:YAG laser with wavelength of 532 nm and an ultrasound microphone with a frequency range of 2200 kHz were both used to detect the shallow defect in the aluminum plate. The LWE image resulting from the pulsed laser has a low signal-to-noise ratio (SNR) and presents wave pattern artifacts because of a low excitation energy. To address this problem, we acquired several data from different laser point positions and constructed LWE images. Because the artifacts in these images are non-correlated, the averaging process removes the artifacts and significantly improves the SNR.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1571-1574
Non-contact leaky Lamb wave imaging based on pulsed laser and ultrasound microphone
A local wavenumber estimation (LWE) method based on a scanning laser Doppler vibrometer (SLDV) is derived using a frequency-wavenumber domain filtering method. LWE methods based on a standing wave have recently been investigated. This technique utilizes SLDV data in the steady-state excitation of a fixed frequency. Despite its various advantages, the LWE method uses contact actuators to provide sufficient vibrating energy. In this study, we solved the cost and complexity problems of using SLDV by replacing it with an ultrasound microphone. We also measured the shallow defect of an aluminum plate using a noncontact-LWE method. A Nd:YAG laser with wavelength of 532 nm and an ultrasound microphone with a frequency range of 2200 kHz were both used to detect the shallow defect in the aluminum plate. The LWE image resulting from the pulsed laser has a low signal-to-noise ratio (SNR) and presents wave pattern artifacts because of a low excitation energy. To address this problem, we acquired several data from different laser point positions and constructed LWE images. Because the artifacts in these images are non-correlated, the averaging process removes the artifacts and significantly improves the SNR.
- 21 May 2012
- Published by ASM International
- Vol. 83720, 510-514
Thermally Enhanced Bonding and Mechanical Properties of Kinetic Sprayed Al Deposit for Double-Layered Cu Liner
- 21 May 2012
- Published by ASM International
- Vol. 83720, 510-514
Thermally Enhanced Bonding and Mechanical Properties of Kinetic Sprayed Al Deposit for Double-Layered Cu Liner