Oluwasola O. Ademulegun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oluwasola O. Ademulegun has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Patrick Keatley
5 shared publications- Neil James Hewitt
Ulster University Belfast UK
4 shared publications Neil Hewitt
3 shared publicationsNeil J. Hewitt
3 shared publicationsYe Huang
3 shared publications- Bukola Oni
Ph.D. Candidate, Dept. of Civil, Construction, and Environmental Engineering, Iowa State Univ., 813 Bissell Rd., Ames, IA 50011. ORCID:
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 149
Flexing electric vehicle charging for socio-technical resilience: Distribution transformer headroom and locational value analyses
- 29 July 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 149
Open AccessFlexing electric vehicle charging for socio-technical resilience: Distribution transformer headroom and locational value analyses
- Open Access
- 30 November 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Designing tariff for charging electric vehicles at home with equity in mind – The tripartite tariff
- 30 November 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 118
Open AccessDesigning tariff for charging electric vehicles at home with equity in mind – The tripartite tariff
- Open Access
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 105 (1) , 103
Flexing the Energy per Day of Electric Vehicles in Northern Ireland
Electric Vehicle (EV) charging will add to the demand for electricity in Northern Ireland (NI) and will prompt upgrades at points on the electricity grid
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 105 (1) , 103
Open AccessFlexing the Energy per Day of Electric Vehicles in Northern Ireland
Electric Vehicle (EV) charging will add to the demand for electricity in Northern Ireland (NI) and will prompt upgrades at points on the electricity grid
- Open Access
Multi-Stage Multi-Criteria Decision Analysis for Siting Electric Vehicle Charging Stations within and across Border Regions
Electric Vehicles (EVs) replace fossil fuel vehicles in effort towards having more sustainable transport systems. The battery of an EV is recharged at a charging point using electricity. While some recharging will be required at locations where vehicles are normally parked, other recharging could be necessary at strategic locations of vehicular travel. Certain locations are suitable for EV charging station deployment, others are not. A multi-stage decision analysis methodology for selecting suitable locations for installing EV charging station is presented. The multi-stage approach makes it possible to select critical criteria with respect to any defined objectives of the EV charging station and techno-physio-socio-economic factors without which the EV charging station could not be deployed or would not serve its designated purpose. In a case, the type of charging station is specified, and a purpose is defined: rapid EV charging stations intended for public use within and across border regions. Applied in siting real EV charging stations at optimal locations, stages in the methodology present additional techno-physio-socio-economic factors in deploying the type of EV charging stations at optimal locations and keep the EV charging stations operating within acceptable standards. Some locations were dropped at the critical analysis stage; others were dropped at the site-specific analysis stage and replacement sites were required in certain instances. Final locations included most optimal, less optimal, least optimal, and strategic or special need locations. The average distances between contiguous recharging locations were less than 60 miles. Using any specified separation standard, the number of additional EV charging stations required between EV charging stations were determinable with the Pool Box. The Overall Charging Station Availability quadrants suggest that the overall user experience could get worse as less-standardized additional EV charging stations are deployed.
Open AccessMulti-Stage Multi-Criteria Decision Analysis for Siting Electric Vehicle Charging Stations within and across Border Regions
Electric Vehicles (EVs) replace fossil fuel vehicles in effort towards having more sustainable transport systems. The battery of an EV is recharged at a charging point using electricity. While some recharging will be required at locations where vehicles are normally parked, other recharging could be necessary at strategic locations of vehicular travel. Certain locations are suitable for EV charging station deployment, others are not. A multi-stage decision analysis methodology for selecting suitable locations for installing EV charging station is presented. The multi-stage approach makes it possible to select critical criteria with respect to any defined objectives of the EV charging station and techno-physio-socio-economic factors without which the EV charging station could not be deployed or would not serve its designated purpose. In a case, the type of charging station is specified, and a purpose is defined: rapid EV charging stations intended for public use within and across border regions. Applied in siting real EV charging stations at optimal locations, stages in the methodology present additional techno-physio-socio-economic factors in deploying the type of EV charging stations at optimal locations and keep the EV charging stations operating within acceptable standards. Some locations were dropped at the critical analysis stage; others were dropped at the site-specific analysis stage and replacement sites were required in certain instances. Final locations included most optimal, less optimal, least optimal, and strategic or special need locations. The average distances between contiguous recharging locations were less than 60 miles. Using any specified separation standard, the number of additional EV charging stations required between EV charging stations were determinable with the Pool Box. The Overall Charging Station Availability quadrants suggest that the overall user experience could get worse as less-standardized additional EV charging stations are deployed.
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of Energy Storage
- Vol. 43
Evaluation of a battery energy storage system in hospitals for arbitrage and ancillary services
- 1 November 2021
- Published by Elsevier in Journal of Energy Storage
- Vol. 43
Open AccessEvaluation of a battery energy storage system in hospitals for arbitrage and ancillary services
- Open Access
- 1 August 2021
- Published by Elsevier in Applied Energy
- Vol. 295
Mapping demand flexibility: A spatio-temporal assessment of flexibility needs, opportunities and response potential
- 1 August 2021
- Published by Elsevier in Applied Energy
- Vol. 295
Open AccessMapping demand flexibility: A spatio-temporal assessment of flexibility needs, opportunities and response potential
- 1 July 2021
- Published by Elsevier in The Electricity Journal
- Vol. 34 (6)
Techno-economic analysis of energy storage within network constraint groups for increasing the share of variable renewable energy
- 1 July 2021
- Published by Elsevier in The Electricity Journal
- Vol. 34 (6)
Techno-economic analysis of energy storage within network constraint groups for increasing the share of variable renewable energy
- 1 December 2020
- Published by Elsevier in Utilities Policy
- Vol. 67
Value of demand flexibility for providing ancillary services: A case for social housing in the Irish DS3 market
- 1 December 2020
- Published by Elsevier in Utilities Policy
- Vol. 67
Value of demand flexibility for providing ancillary services: A case for social housing in the Irish DS3 market
- 1 December 2020
- Published by Elsevier in Utilities Policy
- Vol. 67
Towards a sustainable electricity grid: Market and policy for demand-side storage and wind resources
- 1 December 2020
- Published by Elsevier in Utilities Policy
- Vol. 67
Towards a sustainable electricity grid: Market and policy for demand-side storage and wind resources
- Open Access
- 8 October 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Power conversion in a grid‐connected residential PV system with energy storage using fuzzy‐logic controls
Increasing implementations of renewable energy resources to migrate from fossil fuel based electric power to clean energies have been creating new technical challenges due to their integration into an existing electrical grid. In this research, a power electronic converter based on fuzzy‐logic controller is developed to govern the transfer and control of power in a grid‐connected residential photovoltaic (PV) system with battery storage. A bidirectional dc‐dc converter is designed for power transfer between the loads and the battery. A bidirectional ac‐dc converter is used as the interface between the PV array and the electricity grid. The fuzzy‐logic controller is designed to meet the user power requirement—with the PV array and the battery sized to meet the critical load requirement on site. The results indicate that the fuzzy‐logic‐based power conversion helped the system to adjust to off‐grid, low‐battery, full‐battery, and on‐grid power conditions. The main merit of the design is simplicity in being able to manage the limited supplies from the grid and the renewable PV installation using carefully sized storage that serves critical loads within specific days of power autonomy.
- 8 October 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Open AccessPower conversion in a grid‐connected residential PV system with energy storage using fuzzy‐logic controls
Increasing implementations of renewable energy resources to migrate from fossil fuel based electric power to clean energies have been creating new technical challenges due to their integration into an existing electrical grid. In this research, a power electronic converter based on fuzzy‐logic controller is developed to govern the transfer and control of power in a grid‐connected residential photovoltaic (PV) system with battery storage. A bidirectional dc‐dc converter is designed for power transfer between the loads and the battery. A bidirectional ac‐dc converter is used as the interface between the PV array and the electricity grid. The fuzzy‐logic controller is designed to meet the user power requirement—with the PV array and the battery sized to meet the critical load requirement on site. The results indicate that the fuzzy‐logic‐based power conversion helped the system to adjust to off‐grid, low‐battery, full‐battery, and on‐grid power conditions. The main merit of the design is simplicity in being able to manage the limited supplies from the grid and the renewable PV installation using carefully sized storage that serves critical loads within specific days of power autonomy.