Kota Aoyagi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kota Aoyagi has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Yoshiharu Ohno
Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
3 shared publications - Daisuke Takenaka
Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
2 shared publications - David Chistopher Christiani
39Pulmonary and Critical Care Division, Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts
2 shared publications - Hiroto Hatabu
Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, Boston, USA
2 shared publications Naoki Sugihara
Canon Medical Systems Corporation, Otawara, Tochigi, Japan
2 shared publications- Takeshi Yoshikawa
Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Japan
2 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025026
Automatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume
Aims : Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views. Methods : Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines. Results : The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s. Conclusions : Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.
- 3 March 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025026
Open AccessAutomatic localization of cross sections corresponding to standard transesophageal echocardiographic views on computed tomography volume
Aims : Preoperative observation of computed tomography (CT) cross sections corresponding to standard transesophageal echocardiographic (TEE) views is useful for treatments using TEE. However, manually locating those CT cross sections from the CT volume is time consuming. This study aimed to develop a fully automatic method to locate those CT cross sections corresponding to standard TEE views. Methods : Developed method crops CT volume based on the heart segmentation model if input is a chest CT. CT cross sections corresponding to standard TEE views are coarsely located from cropped chest CT or cardiac CT based on the esophagus segmentation model and the plane localization model. The coarse cross sections are refined based on the anatomical landmark detection model. Accuracies of located CT cross sections were evaluated by five-fold cross validation with comparison to manually set cross sections, using 110 CT volumes. The results were also compared to the top and the middle axial section of the heart as baselines. Results : The mean of rotation error, probe position error, landmark error and structural similarity index between the predicted and manually set cross sections were 12.52 ± 8.27 degree, 13.90 ± 10.62 mm, 3.95 ± 3.48 mm and 0.64 ± 0.15, respectively, and these errors were significantly smaller than the baselines. The mean processing time was 41.34 ± 22.75 s. Conclusions : Our developed method can provide CT cross sections corresponding to standard TEE views without user operations, resulting in faster treatment planning with less effort and without inter user variability in treatments using TEE.
- Open Access
- 11 December 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (4) , 660-672
Automated interstitial lung abnormalities detection at CT: external validation and potential recognition of traction bronchiectasis/bronchiolectasis
Purpose: An artificial intelligence (AI) system for detecting interstitial lung abnormalities (ILA) was previously developed but requires external validation. This study aimed to examine the robustness across different populations and investigate associations between the system outputs and traction bronchiectasis/bronchiolectasis severity patterns. Materials and methods: CT scans from population-based samples of the Rotterdam Study (2018–2019) and the Age Gene/Environment Susceptibility Reykjavik (AGES-Reykjavik) Study (baseline CT: 2002–2006, follow-up CT: 2007–2011) were used in this secondary analysis of the two cohorts. The AI system calculated ILA probability score (AI score) in the range from 0 to 1. Three experienced readers evaluated independently all CT scans for ILA, and two chest radiologists assessed traction bronchiectasis/bronchiolectasis using the 4-scale traction bronchiectasis/bronchiolectasis index (TBI) for severity by consensus. Receiver operating characteristic (ROC) analysis and Kruskal–Wallis test were used for statistical analysis. Results: The system analyzed 932 CT scans of the Rotterdam Study (mean participant age, 79.6 years ± 4.3 (SD), 482 women) and 5242 CT scans of the AGES-Reykjavik Study (mean participant age, 76.4 years ± 5.6, 3032 women), and achieved area under the ROC curve of 0.841 (95% CI 0.804, 0.879) and 0.823 (95% CI 0.798, 0.847), respectively. AI scores correlated with readers’ certainty, decreasing from unanimous ILA cases to No-ILA cases. Higher baseline AI scores correlated with greater severity of traction bronchiectasis/bronchiolectasis (TBI-3: 0.931 [IQR, 0.911–0.932], TBI-2: 0.738 [IQR, 0.406–0.880], TBI-1: 0.537 [IQR, 0.317–0.761], TBI-0: 0.250 [IQR, 0.136–0.455]). Conclusion: The system demonstrated robust ILA detection performance across different populations, with AI scores showing associations with traction bronchiectasis/bronchiolectasis severity.
- 11 December 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (4) , 660-672
Open AccessAutomated interstitial lung abnormalities detection at CT: external validation and potential recognition of traction bronchiectasis/bronchiolectasis
Purpose: An artificial intelligence (AI) system for detecting interstitial lung abnormalities (ILA) was previously developed but requires external validation. This study aimed to examine the robustness across different populations and investigate associations between the system outputs and traction bronchiectasis/bronchiolectasis severity patterns. Materials and methods: CT scans from population-based samples of the Rotterdam Study (2018–2019) and the Age Gene/Environment Susceptibility Reykjavik (AGES-Reykjavik) Study (baseline CT: 2002–2006, follow-up CT: 2007–2011) were used in this secondary analysis of the two cohorts. The AI system calculated ILA probability score (AI score) in the range from 0 to 1. Three experienced readers evaluated independently all CT scans for ILA, and two chest radiologists assessed traction bronchiectasis/bronchiolectasis using the 4-scale traction bronchiectasis/bronchiolectasis index (TBI) for severity by consensus. Receiver operating characteristic (ROC) analysis and Kruskal–Wallis test were used for statistical analysis. Results: The system analyzed 932 CT scans of the Rotterdam Study (mean participant age, 79.6 years ± 4.3 (SD), 482 women) and 5242 CT scans of the AGES-Reykjavik Study (mean participant age, 76.4 years ± 5.6, 3032 women), and achieved area under the ROC curve of 0.841 (95% CI 0.804, 0.879) and 0.823 (95% CI 0.798, 0.847), respectively. AI scores correlated with readers’ certainty, decreasing from unanimous ILA cases to No-ILA cases. Higher baseline AI scores correlated with greater severity of traction bronchiectasis/bronchiolectasis (TBI-3: 0.931 [IQR, 0.911–0.932], TBI-2: 0.738 [IQR, 0.406–0.880], TBI-1: 0.537 [IQR, 0.317–0.761], TBI-0: 0.250 [IQR, 0.136–0.455]). Conclusion: The system demonstrated robust ILA detection performance across different populations, with AI scores showing associations with traction bronchiectasis/bronchiolectasis severity.
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (3) , e233435
Automated Interstitial Lung Abnormality Probability Prediction at CT: A Stepwise Machine Learning Approach in the Boston Lung Cancer Study
An automated interstitial lung abnormality identification model incorporating both a section inference model and a case inference model resulted in an area under the receiver operating characteristic curve of 0.87.
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (3) , e233435
Automated Interstitial Lung Abnormality Probability Prediction at CT: A Stepwise Machine Learning Approach in the Boston Lung Cancer Study
An automated interstitial lung abnormality identification model incorporating both a section inference model and a case inference model resulted in an area under the receiver operating characteristic curve of 0.87.
- 12 October 2021
- Published by SAGE Publications in Acta Radiologica
- Vol. 63 (10) , 1363-1373
Machine learning for lung texture analysis on thin-section CT: Capability for assessments of disease severity and therapeutic effect for connective tissue disease patients in comparison with expert panel evaluations
Background: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD). Purpose: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD. Material and Methods: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CT examinations), pulmonary function tests, and serum KL-6 level tests. Based on all follow-up examination results, all paired serial CT examinations were assessed as “Stable” (n = 188), “Worse” (n = 98) and “Improved” (n = 78). Next, quantitative index changes were determined by software, and qualitative disease severity scores were assessed by consensus of two radiologists. To evaluate differences in each quantitative index as well as in disease severity score between paired serial CT examinations, Tukey's honestly significant difference (HSD) test was performed among the three statuses. Stepwise regression analyses were performed to determine changes in each pulmonary functional parameter and all quantitative indexes between paired serial CT scans. Results: Δ% normal lung, Δ% consolidation, Δ% ground glass opacity, Δ% reticulation, and Δdisease severity score showed significant differences among the three statuses ( P < 0.05). All differences in pulmonary functional parameters were significantly affected by Δ% normal lung, Δ% reticulation, and Δ% honeycomb (0.16 ≤r2 ≤0.42; P < 0.05). Conclusion: ML-based CT texture analysis has better potential than qualitatively assessed thin-section CT for disease severity assessment and treatment response evaluation for CTD-ILD.
- 12 October 2021
- Published by SAGE Publications in Acta Radiologica
- Vol. 63 (10) , 1363-1373
Machine learning for lung texture analysis on thin-section CT: Capability for assessments of disease severity and therapeutic effect for connective tissue disease patients in comparison with expert panel evaluations
Background: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD). Purpose: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD. Material and Methods: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CT examinations), pulmonary function tests, and serum KL-6 level tests. Based on all follow-up examination results, all paired serial CT examinations were assessed as “Stable” (n = 188), “Worse” (n = 98) and “Improved” (n = 78). Next, quantitative index changes were determined by software, and qualitative disease severity scores were assessed by consensus of two radiologists. To evaluate differences in each quantitative index as well as in disease severity score between paired serial CT examinations, Tukey's honestly significant difference (HSD) test was performed among the three statuses. Stepwise regression analyses were performed to determine changes in each pulmonary functional parameter and all quantitative indexes between paired serial CT scans. Results: Δ% normal lung, Δ% consolidation, Δ% ground glass opacity, Δ% reticulation, and Δdisease severity score showed significant differences among the three statuses ( P < 0.05). All differences in pulmonary functional parameters were significantly affected by Δ% normal lung, Δ% reticulation, and Δ% honeycomb (0.16 ≤r2 ≤0.42; P < 0.05). Conclusion: ML-based CT texture analysis has better potential than qualitatively assessed thin-section CT for disease severity assessment and treatment response evaluation for CTD-ILD.
- 1 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (2) , 432-443
Differentiation of Benign from Malignant Pulmonary Nodules by Using a Convolutional Neural Network to Determine Volume Change at Chest CT
A convolutional neural network combined with computer-aided detection of pulmonary nodule volume at CT showed that nodule volume change per day was a better predictor of malignancy than was nodule ... Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for ...
- 1 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (2) , 432-443
Differentiation of Benign from Malignant Pulmonary Nodules by Using a Convolutional Neural Network to Determine Volume Change at Chest CT
A convolutional neural network combined with computer-aided detection of pulmonary nodule volume at CT showed that nodule volume change per day was a better predictor of malignancy than was nodule ... Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for ...
- 1 August 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (8) , 1375-1382
Comparative evaluation of newly developed model-based and commercially available hybrid-type iterative reconstruction methods and filter back projection method in terms of accuracy of computer-aided volumetry (CADv) for low-dose CT protocols in phantom study
- 1 August 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (8) , 1375-1382
Comparative evaluation of newly developed model-based and commercially available hybrid-type iterative reconstruction methods and filter back projection method in terms of accuracy of computer-aided volumetry (CADv) for low-dose CT protocols in phantom study