Sofia Morra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sofia Morra has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Amin Hossein
Laboratory of Physics and Physiology, Université Libre de Bruxelles, Brussels, Belgium
2 shared publications Damien Gorlier
Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles (ULB), Brussels, Belgium
2 shared publications- Jérémy Rabineau
TIPs, Université Libre de Bruxelles, Brussels, Belgium
2 shared publications - Philippe van de Borne
Department of Cardiology, Hopital Erasme - Hopital Universitaire Bruxelles (HE-HUB), Université Libre de Bruxelles (ULB), Brussels, Belgium
2 shared publications - Alessandra Kupper Cardozo
A Cardozo, ULB Center for Diabetes Research, Université Libre de Bruxelles, Brussels, Belgium
1 shared publication - Arnaud Marchant
European Plotkin Institute for Vaccinology, Université Libre de Bruxelles, 900 Route de Lennik, 170 Anderlecht, Belgium; ULB Centre for Research in Immunology (U-CRI), Université Libre de Bruxelles, 8 Rue Adrienne Bolland, 6041 Gosselies, Belgium
1 shared publication
Latest Publications
- Open Access
- 26 February 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (3) , ytae114
Papillary muscle rupture without severe mitral regurgitation following percutaneous balloon mitral commissurotomy: a case report
Background: Percutaneous transvenous mitral commissurotomy (PTMC) is the first-line therapy of clinically significant rheumatic mitral stenosis. While the procedure is generally safe, new onset or aggravation of mitral regurgitation (MR) may occur, mainly due to commissural splitting and, less frequently, to leaflet tear and chordal rupture. Papillary muscle rupture (PMR) is exceedingly rare in this setting. Case summary: A 74-year-old woman with a history of aortic valve replacement and prior rheumatic mitral commissurotomy presented for worsening exercise intolerance and exertional dyspnoea. Transthoracic echocardiography showed a mean pressure gradient of 10 mmHg and a mitral valve area of 1.0 cm², consistent with clinically significant mitral stenosis. Subsequent PTMC was complicated by anterolateral PMR. However, the resulting MR was unexpectedly only of mild-to-moderate severity. Because of residual mitral stenosis and persisting symptoms, surgical mechanical mitral valve replacement and tricuspid annuloplasty were performed 6 weeks after PTMC. Papillary muscle rupture was confirmed during surgery. Discussion: We herein describe the occurrence of PMR induced by PTMC; the resulting MR was unexpectedly of mild-to-moderate severity, as a result of extensive rheumatic lesions limiting valve mobility. This case challenges the dogma according to which PMR invariably leads to severe MR. This might not be necessarily the case when it occurs following PTMC.
- 26 February 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (3) , ytae114
Open AccessPapillary muscle rupture without severe mitral regurgitation following percutaneous balloon mitral commissurotomy: a case report
Background: Percutaneous transvenous mitral commissurotomy (PTMC) is the first-line therapy of clinically significant rheumatic mitral stenosis. While the procedure is generally safe, new onset or aggravation of mitral regurgitation (MR) may occur, mainly due to commissural splitting and, less frequently, to leaflet tear and chordal rupture. Papillary muscle rupture (PMR) is exceedingly rare in this setting. Case summary: A 74-year-old woman with a history of aortic valve replacement and prior rheumatic mitral commissurotomy presented for worsening exercise intolerance and exertional dyspnoea. Transthoracic echocardiography showed a mean pressure gradient of 10 mmHg and a mitral valve area of 1.0 cm², consistent with clinically significant mitral stenosis. Subsequent PTMC was complicated by anterolateral PMR. However, the resulting MR was unexpectedly only of mild-to-moderate severity. Because of residual mitral stenosis and persisting symptoms, surgical mechanical mitral valve replacement and tricuspid annuloplasty were performed 6 weeks after PTMC. Papillary muscle rupture was confirmed during surgery. Discussion: We herein describe the occurrence of PMR induced by PTMC; the resulting MR was unexpectedly of mild-to-moderate severity, as a result of extensive rheumatic lesions limiting valve mobility. This case challenges the dogma according to which PMR invariably leads to severe MR. This might not be necessarily the case when it occurs following PTMC.
- Open Access
- 12 August 2022
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 13, 941663
Chemerin plasma levels are increased in COVID-19 patients and are an independent risk factor of mortality
Background: Chemerin is an extracellular protein with chemotactic activities and its expression is increased in various diseases such as metabolic syndrome and inflammatory conditions. Its role in lung pathology has not yet been extensively studied but both known pro- and anti-inflammatory properties have been observed. The aim of our study was to evaluate the involvement of the chemerin/ChemR23 system in the physiopathology of COVID-19 with a particular focus on its prognostic value.Methods: Blood samples from confirmed COVID-19 patients were collected at day 1, 5 and 14 from admission to Erasme Hospital (Brussels – Belgium). Chemerin concentrations and inflammatory biomarkers were analyzed in the plasma. Blood cells subtypes and their expression of ChemR23 were determined by flow cytometry. The expression of chemerin and ChemR23 was evaluated on lung tissue from autopsied COVID-19 patients by immunohistochemistry (IHC).Results: 21 healthy controls (HC) and 88 COVID-19 patients, including 40 in intensive care unit (ICU) were included. Plasma chemerin concentration were significantly higher in ICU patients than in HC at all time-points analyzed (p<0.0001). Moreover, they were higher in deceased patients compared to survivors (p<0.05). Logistic univariate regression and multivariate analysis demonstrated that chemerin level at day 14 of admission was an independent risk factor for death. Accordingly, chemerin levels correlated with inflammatory biomarkers such as C-reactive protein and tumor necrosis factor α. Finally, IHC analysis revealed a strong expression of ChemR23 on smooth muscle cells and chemerin on myofibroblasts in advanced acute respiratory distress syndrome (ARDS).Discussion: Increased plasma chemerin levels are a marker of severity and may predict death of COVID-19 patients. However, multicentric studies are needed, before chemerin can be considered as a biomarker of severity and death used in daily clinical practice. Further studies are also necessary to identify the precise mechanisms of the chemerin/ChemR23 system in ARDS secondary to viral pneumonia.
- 12 August 2022
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 13, 941663
Open AccessChemerin plasma levels are increased in COVID-19 patients and are an independent risk factor of mortality
Background: Chemerin is an extracellular protein with chemotactic activities and its expression is increased in various diseases such as metabolic syndrome and inflammatory conditions. Its role in lung pathology has not yet been extensively studied but both known pro- and anti-inflammatory properties have been observed. The aim of our study was to evaluate the involvement of the chemerin/ChemR23 system in the physiopathology of COVID-19 with a particular focus on its prognostic value.Methods: Blood samples from confirmed COVID-19 patients were collected at day 1, 5 and 14 from admission to Erasme Hospital (Brussels – Belgium). Chemerin concentrations and inflammatory biomarkers were analyzed in the plasma. Blood cells subtypes and their expression of ChemR23 were determined by flow cytometry. The expression of chemerin and ChemR23 was evaluated on lung tissue from autopsied COVID-19 patients by immunohistochemistry (IHC).Results: 21 healthy controls (HC) and 88 COVID-19 patients, including 40 in intensive care unit (ICU) were included. Plasma chemerin concentration were significantly higher in ICU patients than in HC at all time-points analyzed (p<0.0001). Moreover, they were higher in deceased patients compared to survivors (p<0.05). Logistic univariate regression and multivariate analysis demonstrated that chemerin level at day 14 of admission was an independent risk factor for death. Accordingly, chemerin levels correlated with inflammatory biomarkers such as C-reactive protein and tumor necrosis factor α. Finally, IHC analysis revealed a strong expression of ChemR23 on smooth muscle cells and chemerin on myofibroblasts in advanced acute respiratory distress syndrome (ARDS).Discussion: Increased plasma chemerin levels are a marker of severity and may predict death of COVID-19 patients. However, multicentric studies are needed, before chemerin can be considered as a biomarker of severity and death used in daily clinical practice. Further studies are also necessary to identify the precise mechanisms of the chemerin/ChemR23 system in ARDS secondary to viral pneumonia.
- Open Access
- 12 January 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Assessment of left ventricular twist by 3D ballistocardiography and seismocardiography compared with 2D STI echocardiography in a context of enhanced inotropism in healthy subjects
Ballistocardiography (BCG) and Seismocardiography (SCG) assess the vibrations produced by cardiac contraction and blood flow, respectively, by means of micro-accelerometers and micro-gyroscopes. From the BCG and SCG signals, maximal velocities (VMax), integral of kinetic energy (iK), and maximal power (PMax) can be computed as scalar parameters, both in linear and rotational dimensions. Standard echocardiography and 2-dimensional speckle tracking imaging echocardiography were performed on 34 healthy volunteers who were infused with increasing doses of dobutamine (5–10–20 μg/kg/min). Linear VMax of BCG predicts the rates of left ventricular (LV) twisting and untwisting (both p < 0.0001). The linear PMax of both SCG and BCG and the linear iK of BCG are the best predictors of the LV ejection fraction (LVEF) (p < 0.0001). This result is further confirmed by mathematical models combining the metrics from SCG and BCG signals with heart rate, in which both linear PMax and iK strongly correlate with LVEF (R = 0.7, p < 0.0001). In this setting of enhanced inotropism, the linear VMax of BCG, rather than the VMax of SCG, is the metric which best explains the LV twist mechanics, in particular the rates of twisting and untwisting. PMax and iK metrics are strongly associated with the LVEF and account for 50% of the variance of the LVEF.
- 12 January 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessAssessment of left ventricular twist by 3D ballistocardiography and seismocardiography compared with 2D STI echocardiography in a context of enhanced inotropism in healthy subjects
Ballistocardiography (BCG) and Seismocardiography (SCG) assess the vibrations produced by cardiac contraction and blood flow, respectively, by means of micro-accelerometers and micro-gyroscopes. From the BCG and SCG signals, maximal velocities (VMax), integral of kinetic energy (iK), and maximal power (PMax) can be computed as scalar parameters, both in linear and rotational dimensions. Standard echocardiography and 2-dimensional speckle tracking imaging echocardiography were performed on 34 healthy volunteers who were infused with increasing doses of dobutamine (5–10–20 μg/kg/min). Linear VMax of BCG predicts the rates of left ventricular (LV) twisting and untwisting (both p < 0.0001). The linear PMax of both SCG and BCG and the linear iK of BCG are the best predictors of the LV ejection fraction (LVEF) (p < 0.0001). This result is further confirmed by mathematical models combining the metrics from SCG and BCG signals with heart rate, in which both linear PMax and iK strongly correlate with LVEF (R = 0.7, p < 0.0001). In this setting of enhanced inotropism, the linear VMax of BCG, rather than the VMax of SCG, is the metric which best explains the LV twist mechanics, in particular the rates of twisting and untwisting. PMax and iK metrics are strongly associated with the LVEF and account for 50% of the variance of the LVEF.
- Open Access
- 1 October 2020
- Published by Wiley in Respirology
- Vol. 25 (10) , 1016-1018
Is the e-cigarette harmless among asthmatic patients?
- 1 October 2020
- Published by Wiley in Respirology
- Vol. 25 (10) , 1016-1018
Open AccessIs the e-cigarette harmless among asthmatic patients?
- Open Access
- 1 October 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (10) , 105005
Modification of the mechanical cardiac performance during end-expiratory voluntary apnea recorded with ballistocardiography and seismocardiography
Objective : To assess if micro-accelerometers and gyroscopes may provide useful information for the detection of breathing disturbances in further studies. Approach : Forty-three healthy volunteers performed a 10 s end-expiratory breath-hold, while ballistocardiograph (BCG) and seismocardiograph (SCG) determined changes in kinetic energy and its integral over time ( i K, J · s). BCG measures overall body accelerations in response to blood mass ejection into the main vasculature at each cardiac cycle, while SCG records local chest wall vibrations generated beat-by-beat by myocardial activity. This minimally intrusive technology assesses linear accelerations and angular velocities in 12 degrees of freedom to calculate i K during the whole cardiac cycle. i K produced during systole and diastole were also computed. Main results : The i K during normal breathing was 87.1 [63.3; 132.8] µJ · s for the SCG and 4.5 [3.3; 6.2] µJ · s for the BCG. Both increased to 107.1 [69.0; 162.0] µJ · s and 6.1 [4.4; 9.0] µJ · s, respectively, during breath-holding ( p = 0.003 and p < 0.0001, respectively). The i K of the SCG further increased during spontaneous respiration following apnea (from 107.1 [69.0; 162.0] µJ · s to 160.0 [96.3; 207.3] µJ · s, p < 0.0001). The ratio between the i K of diastole and systole increased from 0.35 [0.24; 0.45] during apnea to 0.49 [0.31; 0.80] ( p < 0.0001) during the restoration of respiration. Significance : A brief voluntary apnea generates large and distinct increases in SCG and BCG waveforms. i K monitoring during sleep may prove useful for the detection of respiratory disturbances. ClinicalTrials.gov number: NCT03760159
- 1 October 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (10) , 105005
Open AccessModification of the mechanical cardiac performance during end-expiratory voluntary apnea recorded with ballistocardiography and seismocardiography
Objective : To assess if micro-accelerometers and gyroscopes may provide useful information for the detection of breathing disturbances in further studies. Approach : Forty-three healthy volunteers performed a 10 s end-expiratory breath-hold, while ballistocardiograph (BCG) and seismocardiograph (SCG) determined changes in kinetic energy and its integral over time ( i K, J · s). BCG measures overall body accelerations in response to blood mass ejection into the main vasculature at each cardiac cycle, while SCG records local chest wall vibrations generated beat-by-beat by myocardial activity. This minimally intrusive technology assesses linear accelerations and angular velocities in 12 degrees of freedom to calculate i K during the whole cardiac cycle. i K produced during systole and diastole were also computed. Main results : The i K during normal breathing was 87.1 [63.3; 132.8] µJ · s for the SCG and 4.5 [3.3; 6.2] µJ · s for the BCG. Both increased to 107.1 [69.0; 162.0] µJ · s and 6.1 [4.4; 9.0] µJ · s, respectively, during breath-holding ( p = 0.003 and p < 0.0001, respectively). The i K of the SCG further increased during spontaneous respiration following apnea (from 107.1 [69.0; 162.0] µJ · s to 160.0 [96.3; 207.3] µJ · s, p < 0.0001). The ratio between the i K of diastole and systole increased from 0.35 [0.24; 0.45] during apnea to 0.49 [0.31; 0.80] ( p < 0.0001) during the restoration of respiration. Significance : A brief voluntary apnea generates large and distinct increases in SCG and BCG waveforms. i K monitoring during sleep may prove useful for the detection of respiratory disturbances. ClinicalTrials.gov number: NCT03760159