Chengyao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chengyao Wang has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Abhinav Bhushan
Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA.
4 shared publications Advait Anil Joshi
Department of Biomedical Engineering Illinois Institute of Technology Chicago IL USA
1 shared publication- Advait Anil Joshi
Illinois Institute of Technology
1 shared publication - Caitlin R. Wessel
University of Louisville School of Medicine, Louisville KY 40202, United States
1 shared publication Chen Zhao
College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai, China
1 shared publicationChien-Pang Lin
National Taiwan University, Taipei, Taiwan ROC
1 shared publication
Latest Publications
- Open Access
- 8 July 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (4)
Deciphering Complex Interactions Between LTR Retrotransposons and Three Papaver Species Using LTR_Stream
Long terminal repeat retrotransposons (LTR-RTs), a major type of class I transposable elements, are the most abundant repeat element in plants. The study of the interactions between LTR-RTs and the host genome relies on high-resolution characterization of LTR-RTs. However, for non-model species, this remains a challenge. To address this, we developed LTR_Stream for sublineage clustering of LTR-RTs in specific or closely related species, providing higher precision than current database-based lineage-level clustering. Using LTR_Stream, we analyzed Retand LTR-RTs in three Papaver species. Our findings show that high-resolution clustering reveals complex interactions between LTR-RTs and the host genome. For instance, we found that autonomous Retand elements could spread among the ancestors of different subgenomes, like retroviral pandemics, enriching genetic diversity. Additionally, we identified that specific truncated fragments containing transcription factor motifs such as TCP and bZIP may contribute to the generation of novel topologically associating domain-like (TAD-like) boundaries. Notably, our pre-allopolyploidization and post-allopolyploidization comparisons show that these effects diminished after allopolyploidization, suggesting that allopolyploidization may be one of the mechanisms by which Papaver species cope with LTR-RTs. We demonstrated the potential application of LTR_Stream and provided a reference case for studying the interactions between LTR-RTs and the host genome in non-model plant species.
- 8 July 2025
- Published by Oxford University Press (OUP) in Genomics, Proteomics & Bioinformatics
- Vol. 23 (4)
Open AccessDeciphering Complex Interactions Between LTR Retrotransposons and Three Papaver Species Using LTR_Stream
Long terminal repeat retrotransposons (LTR-RTs), a major type of class I transposable elements, are the most abundant repeat element in plants. The study of the interactions between LTR-RTs and the host genome relies on high-resolution characterization of LTR-RTs. However, for non-model species, this remains a challenge. To address this, we developed LTR_Stream for sublineage clustering of LTR-RTs in specific or closely related species, providing higher precision than current database-based lineage-level clustering. Using LTR_Stream, we analyzed Retand LTR-RTs in three Papaver species. Our findings show that high-resolution clustering reveals complex interactions between LTR-RTs and the host genome. For instance, we found that autonomous Retand elements could spread among the ancestors of different subgenomes, like retroviral pandemics, enriching genetic diversity. Additionally, we identified that specific truncated fragments containing transcription factor motifs such as TCP and bZIP may contribute to the generation of novel topologically associating domain-like (TAD-like) boundaries. Notably, our pre-allopolyploidization and post-allopolyploidization comparisons show that these effects diminished after allopolyploidization, suggesting that allopolyploidization may be one of the mechanisms by which Papaver species cope with LTR-RTs. We demonstrated the potential application of LTR_Stream and provided a reference case for studying the interactions between LTR-RTs and the host genome in non-model plant species.
- 16 June 2022
- Published by Elsevier in Gastroenterology
- Vol. 162 (7)
Mo1247: TARGETING STROMA INDUCES MORE EFFECTIVE THERAPY IN PATIENT-DERIVED PANCREATIC CANCER ON-A-CHIP
- 16 June 2022
- Published by Elsevier in Gastroenterology
- Vol. 162 (7)
Mo1247: TARGETING STROMA INDUCES MORE EFFECTIVE THERAPY IN PATIENT-DERIVED PANCREATIC CANCER ON-A-CHIP
- 30 December 2021
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 44 (7) , 1258-1268
Hydrodynamic analysis of one deformed double emulsion droplet under shear
The hydrodynamics of one double emulsion droplet under shear is investigated on the basis of a computational fluid dynamic simulation with the volume-of-fluid (VOF) method. The morphological features of the deformed double emulsion droplet at steady state are quantitatively characterized by the deformation and tilt angles, and the potential mechanisms are explored through analyzing pressure and flow information. The existence of the inner droplet engenders two effects (namely enhancing effect and restraining effect) on the outer droplet deformation Dout, determined by which mechanism in a dominant position. With the increase in k, the character of the inner droplet on Dout transforms from enhancing effect into restraining effect under smaller Caout, while under larger Caout the restraining effect is presented in the leading role that inner droplet with different k all inhibits the outer droplet deformation. As the interfacial tension ratio increases under constant Caout, the higher-pressure region at the tip of the inner droplet turning to the “throat” region and the tilt angle θin enlarging both restrain the deformation Dout. In addition, with the increasing viscosity ratio λ12, the outer droplet deformation Dout increases whereas the inner droplet gets smaller deformation; the tilt angles θin and θout both increase and their tilt angle difference gradually increases. Graphical Abstract
- 30 December 2021
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 44 (7) , 1258-1268
Hydrodynamic analysis of one deformed double emulsion droplet under shear
The hydrodynamics of one double emulsion droplet under shear is investigated on the basis of a computational fluid dynamic simulation with the volume-of-fluid (VOF) method. The morphological features of the deformed double emulsion droplet at steady state are quantitatively characterized by the deformation and tilt angles, and the potential mechanisms are explored through analyzing pressure and flow information. The existence of the inner droplet engenders two effects (namely enhancing effect and restraining effect) on the outer droplet deformation Dout, determined by which mechanism in a dominant position. With the increase in k, the character of the inner droplet on Dout transforms from enhancing effect into restraining effect under smaller Caout, while under larger Caout the restraining effect is presented in the leading role that inner droplet with different k all inhibits the outer droplet deformation. As the interfacial tension ratio increases under constant Caout, the higher-pressure region at the tip of the inner droplet turning to the “throat” region and the tilt angle θin enlarging both restrain the deformation Dout. In addition, with the increasing viscosity ratio λ12, the outer droplet deformation Dout increases whereas the inner droplet gets smaller deformation; the tilt angles θin and θout both increase and their tilt angle difference gradually increases. Graphical Abstract
- Open Access
- 27 January 2021
- Published by Wiley in The FASEB Journal
- Vol. 35 (2) , e21291
A novel standalone microfluidic device for local control of oxygen tension for intestinal‐bacteria interactions
The intestinal environment is unique because it supports the intestinal epithelial cells under a normal oxygen environment and the microbiota under an anoxic environment. Due to importance of understanding the interactions between the epithelium and the microbiota, there is a strong need for developing representative and simple experimental models. Current approaches do not capture the partitioned oxygen environment, require external anaerobic chambers, or are complex. Another major limitation is that with the solutions that can mimic this oxygen environment, the oxygenation level of the epithelial cells is not known, raising the question whether the cells are hypoxic or not. We report standalone microfluidic devices that form a partitioned oxygen environment without the use of an external anaerobic chamber or oxygen scavengers to coculture intestinal epithelial and bacterial cells. By changing the thickness of the device cover, the oxygen tension in the chamber was modulated. We verified the oxygen levels using several tests: microscale oxygen sensitive sensors which were integrated within the devices, immunostaining of Caco‐2 cells to determine hypoxia levels, and genetically encoded bacteria to visualize the growth. Collectively, these methods monitored oxygen concentrations in the devices more comprehensively than previous reports and allowed for control of oxygen tension to match the requirements of both intestinal cells and anaerobic bacteria. Our experimental model is supported by the mathematical model that considered diffusion of oxygen into the top chamber. This allowed us to experimentally determine the oxygen consumption rate of the intestinal epithelial cells under perfusion.
- 27 January 2021
- Published by Wiley in The FASEB Journal
- Vol. 35 (2) , e21291
Open AccessA novel standalone microfluidic device for local control of oxygen tension for intestinal‐bacteria interactions
The intestinal environment is unique because it supports the intestinal epithelial cells under a normal oxygen environment and the microbiota under an anoxic environment. Due to importance of understanding the interactions between the epithelium and the microbiota, there is a strong need for developing representative and simple experimental models. Current approaches do not capture the partitioned oxygen environment, require external anaerobic chambers, or are complex. Another major limitation is that with the solutions that can mimic this oxygen environment, the oxygenation level of the epithelial cells is not known, raising the question whether the cells are hypoxic or not. We report standalone microfluidic devices that form a partitioned oxygen environment without the use of an external anaerobic chamber or oxygen scavengers to coculture intestinal epithelial and bacterial cells. By changing the thickness of the device cover, the oxygen tension in the chamber was modulated. We verified the oxygen levels using several tests: microscale oxygen sensitive sensors which were integrated within the devices, immunostaining of Caco‐2 cells to determine hypoxia levels, and genetically encoded bacteria to visualize the growth. Collectively, these methods monitored oxygen concentrations in the devices more comprehensively than previous reports and allowed for control of oxygen tension to match the requirements of both intestinal cells and anaerobic bacteria. Our experimental model is supported by the mathematical model that considered diffusion of oxygen into the top chamber. This allowed us to experimentally determine the oxygen consumption rate of the intestinal epithelial cells under perfusion.
- Open Access
- 1 January 2021
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 70 (24) , 248706
Fabrication of cyclic olefin polymer and polydimethylsiloxane co-bonded microfluidic device and its appliactions in terahertz biological effects on intestinal cells
The current research on the terahertz biological effects at a cellular level is limited by the conventional petri dishes used for cell culture, which cannot be directly used for confocal laser microscopy. In this research, the cycloolefin polymer (COP), a material that possesses low terahertz absorption rate but excellent optical property for microscopy, is bonded to polydimethylsiloxane (PDMS), thereby developing a novel COP-PDMS microfluidic device by using the techniques of soft etching, photolithography, plasma cleaning, high-temperature and high-pressure incubation. The bonding strength of resulting device is tested by using a push-tension meter. The results indicate that the developed device shows a bonding strength as strong as the device fabricated by quartz and PDMS, which is thought as the tightest binding in the multiple types of microfluidic device. In addition, by perfusing the device chamber at a high flow rate (200 μL/s) and long-term time-course (2 weeks), which simulates the dynamic shearing stress occurring in in-vivo organs and tissues, this COP-PDMS microfluidic device can still maintain the original shape and sealing property, indicating that this device qualifies the requirements of the following dynamic cell culture.The biological effects of terahertz on the cells are explored by using this COP-PDMS microfluidic device mentioned above. In this device, we develop the dynamic culture of intestinal epithelial cells Caco-2 with a perfusion rate of 0.05 μL/s, which meets the findings of the in-vivo gastrointestinal lumen shearing stress. The Caco-2 cells are then irradiated with 0.1 THz wave with the power of 15 mW/cm2 for 3 days, and the irradiation duration is 10 min per day. The biological effects of terahertz irradiation on the intercellular tight junction protein ZO-1, the Paxillin relating to the cell adhesion and migration, and the cytoskeletal microfilament protein F-actin of Caco-2 cells are detected in the device directly using the technique of immunofluorescence staining.The results show that the morphology of cell adhesion as well as the level and distribution of ZO-1 and Paxillin are changed. In brief, the protein expression of ZO-1 and Paxillin are induced more by the terahertz irradiation, while the F-actin is not influenced by the irradiation. As can be seen from the F-actin results, the cells without terahertz irradiation show a spread and outward shape with regular smooth cell edge while a contraction and burr shape of cell edge are shown after irradiation, suggesting that the cell adhesion is weakened after irradiation. Even though the expression level of F-actin is consistent, the changed morphology indicates that terahertz may regulate the interaction and aggregation among actin proteins in cells. Interestingly, the ZO-1 presents diffuse distribution in the cells and its location on the cell membrane is not obvious, that is, a large amount of ZO-1 expresses not only on the cell membrane but also in the intracellular matrix after the irradiation. The expression of Paxillin is enhanced after terahertz irradiation, and some cells show local aggregation and distribution of Paxillin. These indicate that the terahertz irradiation might affect the biomolecular mechanism of synthesis and distribution of protein. The COP-PDMS co-bonded microfluidic device developed in this study provides a convenient and effective platform for exploring the biological effects of terahertz irradiation on cells, and is expected to be further used for real-time research on the effects of terahertz on cells and molecules in the future.
- 1 January 2021
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 70 (24) , 248706
Open AccessFabrication of cyclic olefin polymer and polydimethylsiloxane co-bonded microfluidic device and its appliactions in terahertz biological effects on intestinal cells
The current research on the terahertz biological effects at a cellular level is limited by the conventional petri dishes used for cell culture, which cannot be directly used for confocal laser microscopy. In this research, the cycloolefin polymer (COP), a material that possesses low terahertz absorption rate but excellent optical property for microscopy, is bonded to polydimethylsiloxane (PDMS), thereby developing a novel COP-PDMS microfluidic device by using the techniques of soft etching, photolithography, plasma cleaning, high-temperature and high-pressure incubation. The bonding strength of resulting device is tested by using a push-tension meter. The results indicate that the developed device shows a bonding strength as strong as the device fabricated by quartz and PDMS, which is thought as the tightest binding in the multiple types of microfluidic device. In addition, by perfusing the device chamber at a high flow rate (200 μL/s) and long-term time-course (2 weeks), which simulates the dynamic shearing stress occurring in in-vivo organs and tissues, this COP-PDMS microfluidic device can still maintain the original shape and sealing property, indicating that this device qualifies the requirements of the following dynamic cell culture.The biological effects of terahertz on the cells are explored by using this COP-PDMS microfluidic device mentioned above. In this device, we develop the dynamic culture of intestinal epithelial cells Caco-2 with a perfusion rate of 0.05 μL/s, which meets the findings of the in-vivo gastrointestinal lumen shearing stress. The Caco-2 cells are then irradiated with 0.1 THz wave with the power of 15 mW/cm2 for 3 days, and the irradiation duration is 10 min per day. The biological effects of terahertz irradiation on the intercellular tight junction protein ZO-1, the Paxillin relating to the cell adhesion and migration, and the cytoskeletal microfilament protein F-actin of Caco-2 cells are detected in the device directly using the technique of immunofluorescence staining.The results show that the morphology of cell adhesion as well as the level and distribution of ZO-1 and Paxillin are changed. In brief, the protein expression of ZO-1 and Paxillin are induced more by the terahertz irradiation, while the F-actin is not influenced by the irradiation. As can be seen from the F-actin results, the cells without terahertz irradiation show a spread and outward shape with regular smooth cell edge while a contraction and burr shape of cell edge are shown after irradiation, suggesting that the cell adhesion is weakened after irradiation. Even though the expression level of F-actin is consistent, the changed morphology indicates that terahertz may regulate the interaction and aggregation among actin proteins in cells. Interestingly, the ZO-1 presents diffuse distribution in the cells and its location on the cell membrane is not obvious, that is, a large amount of ZO-1 expresses not only on the cell membrane but also in the intracellular matrix after the irradiation. The expression of Paxillin is enhanced after terahertz irradiation, and some cells show local aggregation and distribution of Paxillin. These indicate that the terahertz irradiation might affect the biomolecular mechanism of synthesis and distribution of protein. The COP-PDMS co-bonded microfluidic device developed in this study provides a convenient and effective platform for exploring the biological effects of terahertz irradiation on cells, and is expected to be further used for real-time research on the effects of terahertz on cells and molecules in the future.
- Open Access
A Novel Standalone Microfluidic Device for Local Control of Oxygen Tension for Intestinal-Bacteria Interactions
The intestinal environment is unique because it supports the intestinal epithelial cells under a normal oxygen environment and the microbiota under an anoxic environment. Due to importance of understanding the interactions between the epithelium and the microbiota, there is a strong need for developing representative and simple experimental models. Current approaches do not capture the dual-oxygen environment, require external anaerobic chambers, or are complex. Another major limitation is that in the solutions that can mimic the dual-oxygen environment, the oxygenation level of the epithelial cells is not known, raising the question whether the cells are hypoxic. We report standalone microfluidic devices that form a dual-oxygen environment without the use of an external anaerobic chamber or oxygen scavengers to coculture intestinal epithelial and bacterial cells. By changing the thickness of the device cover, the oxygen tension in the chamber could be modulated. We verified the oxygen levels using several tests: microscale oxygen sensitive sensors incorporated within the devices, hypoxic immunostaining of Caco-2 cells, and genetically encoded bacteria. Collectively, these methods monitored oxygen concentrations in devices more comprehensively than previous reports and allowed for control of oxygen tension to match the requirements of both intestinal cells and anaerobic bacteria. Our experimental model is supported by the mathematical model that considers diffusion of oxygen into the top chamber and the cellular oxygen consumption rate. This allowed us to experimentally determine the oxygen consumption rate of the epithelial cells more precisely.
Open AccessA Novel Standalone Microfluidic Device for Local Control of Oxygen Tension for Intestinal-Bacteria Interactions
The intestinal environment is unique because it supports the intestinal epithelial cells under a normal oxygen environment and the microbiota under an anoxic environment. Due to importance of understanding the interactions between the epithelium and the microbiota, there is a strong need for developing representative and simple experimental models. Current approaches do not capture the dual-oxygen environment, require external anaerobic chambers, or are complex. Another major limitation is that in the solutions that can mimic the dual-oxygen environment, the oxygenation level of the epithelial cells is not known, raising the question whether the cells are hypoxic. We report standalone microfluidic devices that form a dual-oxygen environment without the use of an external anaerobic chamber or oxygen scavengers to coculture intestinal epithelial and bacterial cells. By changing the thickness of the device cover, the oxygen tension in the chamber could be modulated. We verified the oxygen levels using several tests: microscale oxygen sensitive sensors incorporated within the devices, hypoxic immunostaining of Caco-2 cells, and genetically encoded bacteria. Collectively, these methods monitored oxygen concentrations in devices more comprehensively than previous reports and allowed for control of oxygen tension to match the requirements of both intestinal cells and anaerobic bacteria. Our experimental model is supported by the mathematical model that considers diffusion of oxygen into the top chamber and the cellular oxygen consumption rate. This allowed us to experimentally determine the oxygen consumption rate of the epithelial cells more precisely.
- 21 February 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (4) , 1377-1385
Novel Microfluidic Colon with an Extracellular Matrix Membrane
Collagen is a key element of basal lamina in physiological system that participates in cell and tissue culture. Its function is for cells maintenance, growth, angiogenesis, disease progression, and immunology. The goal of our present study was to synthesize and integrated a micrometer resolution type I collagen membrane sandwiched between two layers of a microfluidic organ-on-a-chip device. In order to evaluate the compatibility of the resulted membrane, human colon caco 2 cells were successfully cultured on top of the membrane. Membrane microstructure, transport and cells viability in the organs-on-chips were observed to confirm the suitability of our resulted membrane. Through transport studies, we compared the diffusion through two different membranes – Transwell and the collagen membrane. We found that mass transport of 40kDa dextran was an order of magnitude higher through the collagen membrane than that through the Transwell membrane. Human colon caco 2 cells were cultured in devices with no, Transwell, and ECM membrane to evaluate the compatibility of cells on ECM membrane compared to other two membranes. We found that caco 2 cells cultured on the collagen membrane had excellent viability and function for extended periods of time compared to other two devices. Our results indicate a substantial improvement in establishing a physiological microenvironment for in vitro organs-on-chips.
- 21 February 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (4) , 1377-1385
Novel Microfluidic Colon with an Extracellular Matrix Membrane
Collagen is a key element of basal lamina in physiological system that participates in cell and tissue culture. Its function is for cells maintenance, growth, angiogenesis, disease progression, and immunology. The goal of our present study was to synthesize and integrated a micrometer resolution type I collagen membrane sandwiched between two layers of a microfluidic organ-on-a-chip device. In order to evaluate the compatibility of the resulted membrane, human colon caco 2 cells were successfully cultured on top of the membrane. Membrane microstructure, transport and cells viability in the organs-on-chips were observed to confirm the suitability of our resulted membrane. Through transport studies, we compared the diffusion through two different membranes – Transwell and the collagen membrane. We found that mass transport of 40kDa dextran was an order of magnitude higher through the collagen membrane than that through the Transwell membrane. Human colon caco 2 cells were cultured in devices with no, Transwell, and ECM membrane to evaluate the compatibility of cells on ECM membrane compared to other two membranes. We found that caco 2 cells cultured on the collagen membrane had excellent viability and function for extended periods of time compared to other two devices. Our results indicate a substantial improvement in establishing a physiological microenvironment for in vitro organs-on-chips.
- 1 January 2017
- Published by Elsevier in Solar Energy
- Vol. 141, 59-69
A novel design concept for a reflector of parabolic trough concentrator based on pure bending and correction principle
- 1 January 2017
- Published by Elsevier in Solar Energy
- Vol. 141, 59-69
A novel design concept for a reflector of parabolic trough concentrator based on pure bending and correction principle
- Open Access
- 21 October 2013
- Published by Association for Computing Machinery (ACM)
- p. 777-780
RealSense
- 21 October 2013
- Published by Association for Computing Machinery (ACM)
- p. 777-780
Open AccessRealSense
- Retracted
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (21619069) , V13-262
Notice of Retraction: Coordination patterns for enterprise information systems
This article has been retracted by the publisher.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (21619069) , V13-262
RetractedNotice of Retraction: Coordination patterns for enterprise information systems
This article has been retracted by the publisher.