Mitsuo Nakai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mitsuo Nakai has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Shinsuke Fujioka
Osaka University
7 shared publications - Yasunobu Arikawa
The University of Osaka
6 shared publications - Yuki Abe
The University of Osaka Graduate School of Engineering 2-1 Yamadaoka, Suita, Osaka 565-0871
5 shared publications - Seyed Reza Mirfayzi
Tokamak Energy ltd, Milton, United Kingdom
4 shared publications A. Yogo
Institute of Laser Engineering, Osaka University 1 , Osaka 565-0871, Japan
3 shared publicationsH. Shiraga
Institute of Laser Engineering, Osaka University 2 , Osaka 565-0871, Japan
3 shared publications
Latest Publications
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093523
Predictive capability of material screening by fast neutron activation analysis using laser-driven neutron sources
Bright, short-pulsed neutron beams from laser-driven neutron sources (LANSs) provide a new perspective on material screening via fast neutron activation analysis (FNAA). FNAA is a nondestructive technique for determining material elemental composition based on nuclear excitation by fast neutron bombardment and subsequent spectral analysis of prompt γ-rays emitted by the active nuclei. Our recent experiments and simulations have shown that activation analysis can be used in practice with modest neutron fluences on the order of 105 n/cm2, which is available with current laser technology. In addition, time-resolved γ-ray measurements combined with picosecond neutron probes from LANSs are effective in mitigating the issue of spectral interference between elements, enabling highly accurate screening of complex samples containing many elements. This paper describes the predictive capability of LANS-based activation analysis based on experimental demonstrations and spectral calculations with Monte Carlo simulations.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093523
Predictive capability of material screening by fast neutron activation analysis using laser-driven neutron sources
Bright, short-pulsed neutron beams from laser-driven neutron sources (LANSs) provide a new perspective on material screening via fast neutron activation analysis (FNAA). FNAA is a nondestructive technique for determining material elemental composition based on nuclear excitation by fast neutron bombardment and subsequent spectral analysis of prompt γ-rays emitted by the active nuclei. Our recent experiments and simulations have shown that activation analysis can be used in practice with modest neutron fluences on the order of 105 n/cm2, which is available with current laser technology. In addition, time-resolved γ-ray measurements combined with picosecond neutron probes from LANSs are effective in mitigating the issue of spectral interference between elements, enabling highly accurate screening of complex samples containing many elements. This paper describes the predictive capability of LANS-based activation analysis based on experimental demonstrations and spectral calculations with Monte Carlo simulations.
- 15 June 2022
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 78 (7) , 513-527
NMR Spectroscopy for Proof-of-Concept Experimentation on a Polarized Laser Fusion Process
A test experiment to polarize tritium nuclei to develop a polarized deuterium-tritium (D-T) laser fusion concept is proposed in which a ferromagnetic complex with a high internal magnetic field is used to polarize tritium nuclei on physisorbed D-T molecules with an internal β-decay heat load in a D-T target. Heteronuclear hydrogen deuteride (HD) is used to conduct the measurements herein instead of as in typical D-T–based experiments. As proof-of-concept experimentation, the adsorption and desorption characteristics of HD are examined on Prussian blue ferromagnetic analogue Ni3[Fe(CN)6]2 at temperatures of 77 K and around 23 K. Nuclear magnetic resonance (NMR) analysis of the ferromagnetic complex-mediated adsorption of HD onto activated carbon pellets at 10 K is conducted step by step using a multilocular probe cell that had been simplified to give a single-tube probe cell. The resulting 1H NMR spectra are compared with 19F NMR spectra obtained for reference on a Kel-F probe cell wall. Slight differences between the calculated NMR frequency from the gyromagnetic ratio and the actually observed NMR frequency are also discussed.
- 15 June 2022
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 78 (7) , 513-527
NMR Spectroscopy for Proof-of-Concept Experimentation on a Polarized Laser Fusion Process
A test experiment to polarize tritium nuclei to develop a polarized deuterium-tritium (D-T) laser fusion concept is proposed in which a ferromagnetic complex with a high internal magnetic field is used to polarize tritium nuclei on physisorbed D-T molecules with an internal β-decay heat load in a D-T target. Heteronuclear hydrogen deuteride (HD) is used to conduct the measurements herein instead of as in typical D-T–based experiments. As proof-of-concept experimentation, the adsorption and desorption characteristics of HD are examined on Prussian blue ferromagnetic analogue Ni3[Fe(CN)6]2 at temperatures of 77 K and around 23 K. Nuclear magnetic resonance (NMR) analysis of the ferromagnetic complex-mediated adsorption of HD onto activated carbon pellets at 10 K is conducted step by step using a multilocular probe cell that had been simplified to give a single-tube probe cell. The resulting 1H NMR spectra are compared with 19F NMR spectra obtained for reference on a Kel-F probe cell wall. Slight differences between the calculated NMR frequency from the gyromagnetic ratio and the actually observed NMR frequency are also discussed.
- Open Access
- 1 April 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (4) , 045220
Non-destructive inspection of water or high-pressure hydrogen gas in metal pipes by the flash of neutrons and x rays generated by laser
The thermal and epithermal neutrons are powerful probes to inspect water or high-pressure hydrogen gas because of their large scattering cross-sections with protons. Laser-driven neutron source, which is able to simultaneously emit different types of radiations such as x rays, can be used for neutron and x-ray radiography in the same laser shot. In this paper, we report the demonstration of non-destructive inspection for H2O contained within a stainless steel pipe using a laser-driven thermal neutron source, where water and stainless containers are detected by neutrons and x rays, respectively. The simulation result indicates that this method can also provide the capability to measure the hydrogen density in high-pressure hydrogen gas in metal containers.
- 1 April 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (4) , 045220
Open AccessNon-destructive inspection of water or high-pressure hydrogen gas in metal pipes by the flash of neutrons and x rays generated by laser
The thermal and epithermal neutrons are powerful probes to inspect water or high-pressure hydrogen gas because of their large scattering cross-sections with protons. Laser-driven neutron source, which is able to simultaneously emit different types of radiations such as x rays, can be used for neutron and x-ray radiography in the same laser shot. In this paper, we report the demonstration of non-destructive inspection for H2O contained within a stainless steel pipe using a laser-driven thermal neutron source, where water and stainless containers are detected by neutrons and x rays, respectively. The simulation result indicates that this method can also provide the capability to measure the hydrogen density in high-pressure hydrogen gas in metal containers.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 063301
Dosimetric calibration of GafChromic HD-V2, MD-V3, and EBT3 films for dose ranges up to 100 kGy
A dosimetric calibration of three types of radiochromic films (GafChromicTM HD-V2, MD-V3, and EBT3) was carried out for absorbed doses (D) ranging up to 100 kGy using a 130 TBq γ-ray source. The optical densities (ODs) of the irradiated films were acquired with the transmission-mode flatbed film scanner EPSON GT-X980. The calibration data were cross-checked using the 20-MeV proton beam from the azimuthally varying field cyclotron at the Research Center for Nuclear Physics in Osaka University. These experimental results not only present the measurable dose ranges of the films depending on the readout wavelength, but also show consistency with our hypothesis that the OD response curve [log(OD)–log(D) curve] is determined by the volumetric average of the absorption dose and does not strongly depend on the type of radiation for the excitation.- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 063301
Dosimetric calibration of GafChromic HD-V2, MD-V3, and EBT3 films for dose ranges up to 100 kGy
A dosimetric calibration of three types of radiochromic films (GafChromicTM HD-V2, MD-V3, and EBT3) was carried out for absorbed doses (D) ranging up to 100 kGy using a 130 TBq γ-ray source. The optical densities (ODs) of the irradiated films were acquired with the transmission-mode flatbed film scanner EPSON GT-X980. The calibration data were cross-checked using the 20-MeV proton beam from the azimuthally varying field cyclotron at the Research Center for Nuclear Physics in Osaka University. These experimental results not only present the measurable dose ranges of the films depending on the readout wavelength, but also show consistency with our hypothesis that the OD response curve [log(OD)–log(D) curve] is determined by the volumetric average of the absorption dose and does not strongly depend on the type of radiation for the excitation.- 27 May 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (6) , 053306
The conceptual design of 1-ps time resolution neutron detector for fusion reaction history measurement at OMEGA and the National Ignition Facility
The nuclear burn history provides critical information about the dynamics of the hot-spot formation and high-density fuel-shell assembly of an Inertial Confinement Fusion (ICF) implosion, as well as information on the impact of alpha heating, and a multitude of implosion failure mechanisms. Having this information is critical for assessing the energy-confinement time τE and performance of an implosion. As the confinement time of an ICF implosion is a few tens of picoseconds, less than 10-ps time resolution is required for an accurate measurement of the nuclear burn history. In this study, we propose a novel 1-ps time-resolution detection scheme based on the Pockels effect. In particular, a conceptual design for the experiment on the National Ignition Facility and OMEGA are elaborated upon herein. A small organic Pockels crystal “DAST” is designed to be positioned ∼5 mm from the ICF implosion, which is scanned by a chirped pulse generated by a femto-second laser transmitted through a polarization-maintained optical fiber. The originally linearly polarized laser is changed to an elliptically polarized laser by the Pockels crystal when exposed to neutrons, and the modulation of the polarization will be analyzed. Our study using 35-MeV electrons showed that the system impulse response is 0.6 ps. The response time is orders of magnitude shorter than current systems. Through measurements of the nuclear burn history with unprecedented time resolution, this system will help for a better understanding of the dynamics of the hot-spot formation, high-density fuel-shell assembly, and the physics of thermonuclear burn wave propagation.
- 27 May 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (6) , 053306
The conceptual design of 1-ps time resolution neutron detector for fusion reaction history measurement at OMEGA and the National Ignition Facility
The nuclear burn history provides critical information about the dynamics of the hot-spot formation and high-density fuel-shell assembly of an Inertial Confinement Fusion (ICF) implosion, as well as information on the impact of alpha heating, and a multitude of implosion failure mechanisms. Having this information is critical for assessing the energy-confinement time τE and performance of an implosion. As the confinement time of an ICF implosion is a few tens of picoseconds, less than 10-ps time resolution is required for an accurate measurement of the nuclear burn history. In this study, we propose a novel 1-ps time-resolution detection scheme based on the Pockels effect. In particular, a conceptual design for the experiment on the National Ignition Facility and OMEGA are elaborated upon herein. A small organic Pockels crystal “DAST” is designed to be positioned ∼5 mm from the ICF implosion, which is scanned by a chirped pulse generated by a femto-second laser transmitted through a polarization-maintained optical fiber. The originally linearly polarized laser is changed to an elliptically polarized laser by the Pockels crystal when exposed to neutrons, and the modulation of the polarization will be analyzed. Our study using 35-MeV electrons showed that the system impulse response is 0.6 ps. The response time is orders of magnitude shorter than current systems. Through measurements of the nuclear burn history with unprecedented time resolution, this system will help for a better understanding of the dynamics of the hot-spot formation, high-density fuel-shell assembly, and the physics of thermonuclear burn wave propagation.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I128
A large-aperture high-sensitivity avalanche image intensifier panel
A large-aperture high-sensitivity image intensifier panel that consists of an avalanche photodiode array and a light-emitting diode array is presented. The device has 40% quantum efficiency, over 104 optical gain, and 80-ns time resolution. The aperture size of the device is 20 cm, and with the current manufacturing process, it can be scaled to arbitrarily larger sizes. The device can intensify the light from a single particle scintillation emission to an eye-visible bright flash. The image resolution of the device is currently limited by the size of the avalanche photodiode that is 2 mm, although it can be scaled to smaller sizes in the near future. The image intensifier is operated at a small voltage, typically +57 V. The device can be applied to various applications, such as scintillation imaging, night vision cameras, and an image converter from non-visible light (such as infrared or ultraviolet) to visible light.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I128
A large-aperture high-sensitivity avalanche image intensifier panel
A large-aperture high-sensitivity image intensifier panel that consists of an avalanche photodiode array and a light-emitting diode array is presented. The device has 40% quantum efficiency, over 104 optical gain, and 80-ns time resolution. The aperture size of the device is 20 cm, and with the current manufacturing process, it can be scaled to arbitrarily larger sizes. The device can intensify the light from a single particle scintillation emission to an eye-visible bright flash. The image resolution of the device is currently limited by the size of the avalanche photodiode that is 2 mm, although it can be scaled to smaller sizes in the near future. The image intensifier is operated at a small voltage, typically +57 V. The device can be applied to various applications, such as scintillation imaging, night vision cameras, and an image converter from non-visible light (such as infrared or ultraviolet) to visible light.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I114
A multichannel gated neutron detector with reduced afterpulse for low-yield neutron measurements in intense hard X-ray backgrounds
A design of multichannel gated photomultiplier tube (PMT) is presented for the 960-channel neutron time-of-flight detector at the Institute of Laser Engineering of Osaka University. This is important for the fusion science and the nuclear photonics where intense hard X-rays are generated from the interaction of ultra-short laser pulse of petawatt power density with matter. The hard X-rays often overload PMTs and cause signal-induced background noises called afterpulses, making the detection of subsequent neutrons impossible. For this reason, the PMTs are coupled with an electrical time-gating (ETG) system to avoid overloading. The ETG system disables the PMT by modulating the dynode potential during the primary X-ray flash. An after-pulsing suppression technique is demonstrated by applying a reverse bias voltage between the photocathode and the first dynode. The presented multichannel scheme provides a gate response time of 80 ns, a signal cutoff ratio of 2.5 × 102, and requires reasonably low power consumption.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I114
A multichannel gated neutron detector with reduced afterpulse for low-yield neutron measurements in intense hard X-ray backgrounds
A design of multichannel gated photomultiplier tube (PMT) is presented for the 960-channel neutron time-of-flight detector at the Institute of Laser Engineering of Osaka University. This is important for the fusion science and the nuclear photonics where intense hard X-rays are generated from the interaction of ultra-short laser pulse of petawatt power density with matter. The hard X-rays often overload PMTs and cause signal-induced background noises called afterpulses, making the detection of subsequent neutrons impossible. For this reason, the PMTs are coupled with an electrical time-gating (ETG) system to avoid overloading. The ETG system disables the PMT by modulating the dynode potential during the primary X-ray flash. An after-pulsing suppression technique is demonstrated by applying a reverse bias voltage between the photocathode and the first dynode. The presented multichannel scheme provides a gate response time of 80 ns, a signal cutoff ratio of 2.5 × 102, and requires reasonably low power consumption.
- Open Access
- 1 January 2008
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 43 (3) , 109-113
Development of a Cryogenic Target for the "Fast Ignition Realization Experiment"-Technique for measuring the fuel layer using an interferometer-
- 1 January 2008
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 43 (3) , 109-113
Open AccessDevelopment of a Cryogenic Target for the "Fast Ignition Realization Experiment"-Technique for measuring the fuel layer using an interferometer-
- 20 May 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5374, 918-926
Estimation of emission efficiency for laser-produced EUV plasmas
Extreme Ultra Violet (EUV) light source produced by laser irradiation emits not only the desired EUV light of 13 ~ 14 nm (about 90 eV) but also shorter x-rays. For example, emissions around 4 ~ 8 nm (about 150 ~ 300 eV) and 1 ~ 2.5 nm (about 0.5 ~ 1.2 keV) are experimentally observed from Sn and/or SnO2 plasmas. These emissions are correspond to the N-shell and M-shell transitions, respectively. From the view point of energy balance and efficiency, these transitions should be suppressed. However, they may, to some extent, contribute to provide the 5p and 4f levels with electrons which eventually emit the EUV light and enhance the intensity. To know well about radiative properties and kinematic of the whole plasma, atomic population kinetics and spectral synthesis codes have been developed. These codes can estimate the atomic population with nl-scheme and spectral shapes of the EUV light. Radiation hydrodynamic simulation have been proceeding in this analysis. Finally, the laser intensity dependence of the conversion efficiency calculated by these codes agrees with that of the corresponding experimental results.
- 20 May 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5374, 918-926
Estimation of emission efficiency for laser-produced EUV plasmas
Extreme Ultra Violet (EUV) light source produced by laser irradiation emits not only the desired EUV light of 13 ~ 14 nm (about 90 eV) but also shorter x-rays. For example, emissions around 4 ~ 8 nm (about 150 ~ 300 eV) and 1 ~ 2.5 nm (about 0.5 ~ 1.2 keV) are experimentally observed from Sn and/or SnO2 plasmas. These emissions are correspond to the N-shell and M-shell transitions, respectively. From the view point of energy balance and efficiency, these transitions should be suppressed. However, they may, to some extent, contribute to provide the 5p and 4f levels with electrons which eventually emit the EUV light and enhance the intensity. To know well about radiative properties and kinematic of the whole plasma, atomic population kinetics and spectral synthesis codes have been developed. These codes can estimate the atomic population with nl-scheme and spectral shapes of the EUV light. Radiation hydrodynamic simulation have been proceeding in this analysis. Finally, the laser intensity dependence of the conversion efficiency calculated by these codes agrees with that of the corresponding experimental results.
- Open Access
- 15 August 1990
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 68 (4) , 1483-1488
Three-dimensional imaging of laser imploded targets
Copyright 1990 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Journal of Applied Physics, 68(4), 1483-1488, 1990 and may be found at http://dx.doi.org/10.1063/1.34667
- 15 August 1990
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 68 (4) , 1483-1488
Open AccessThree-dimensional imaging of laser imploded targets
Copyright 1990 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Journal of Applied Physics, 68(4), 1483-1488, 1990 and may be found at http://dx.doi.org/10.1063/1.34667