Kristian Ninov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kristian Ninov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Sirakov
Interventional Radiology department, UH St Ivan Rilski, Sofia, Bulgaria
2 shared publications - Stanimir Sirakov
Radiology department, University Hospital St Ivan Rilski, Sofia, Bulgaria
2 shared publications Atanas Kundurdjiev
Clinic of Nephrology, University Hospital St. Iv. Rilski, Medical University, Sofia, Bulgaria
1 shared publicationBorislav Yoshinov
Clinic of Neurology, University Hospital St. Iv. Rilski, Medical University, Sofia, Bulgaria
1 shared publicationG. Vladev
From the Radiology Department (G.V., A.S., S.M., S.S.), UH St Ivan Rilski, Sofia, Bulgaria
1 shared publicationIvana Kalinkova
Clinic of Nephrology, University Hospital St. Iv. Rilski, Medical University, Sofia, Bulgaria
1 shared publication
Latest Publications
- 20 March 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (4) , 712-719
Subacute Stent Deformities as an Underlying Reason for Vessel Stenosis after Flow Diversion with the p64 Stent: Review and Discussion of Biologic Mechanisms and Consequences
Flow-diverter stents are a potent and efficient tool in the instrumentarium of neurointerventional radiologists for the treatment of intracranial aneurysms. With their implementation, some adverse effects and complications such as hemorrhagic and ischemic ones, have been seen as a potential downfall of the method. In-stent stenosis is one such complication, which until now has not received enormous attention due to its seemingly benign characteristic. In our study we propose a different point of view on this matter and aim to establish a potential mechanism for its development: a subacute postprocedural stent deformation, due to segmental vessel constriction as a reaction to the implant. We enrolled 48 patients between the ages of 31 and 71 (8 men) with aneurysms on the distal portions of the ICA, all of whom were treated with the p64 flow-diverter stent, to assess the incidence of this phenomenon, as well as establish a correlation between it and subsequent clinical symptoms. A protocol for short-term follow-up, consisting only of a high-dose fluoroscopy image of the implant (conducted on the 14th postprocedural day) was implemented to assess the state of the implant before endothelization was to be expected. Stent deformities were seen in 58% of cases. One patient with an observed stent deformity presented with several episodes of acute contralateral 1-sided weakness of the limbs. Seventy-one percent of those patients presented with a mild/moderate unilateral headache postprocedurally. A correlation between the deformity and a subsequent narrowing of the parent vessel diameter was established on follow-ups. Notable in-stent stenosis was reported in 35% of all cases. Cases with subacute stent deformities are presented in a nonnegligible percent of flow-diversion therapies with the p64 stent. A statistically significant association between the observed deformation and subsequent in-stent stenosis was observed on follow-up.
- 20 March 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (4) , 712-719
Subacute Stent Deformities as an Underlying Reason for Vessel Stenosis after Flow Diversion with the p64 Stent: Review and Discussion of Biologic Mechanisms and Consequences
Flow-diverter stents are a potent and efficient tool in the instrumentarium of neurointerventional radiologists for the treatment of intracranial aneurysms. With their implementation, some adverse effects and complications such as hemorrhagic and ischemic ones, have been seen as a potential downfall of the method. In-stent stenosis is one such complication, which until now has not received enormous attention due to its seemingly benign characteristic. In our study we propose a different point of view on this matter and aim to establish a potential mechanism for its development: a subacute postprocedural stent deformation, due to segmental vessel constriction as a reaction to the implant. We enrolled 48 patients between the ages of 31 and 71 (8 men) with aneurysms on the distal portions of the ICA, all of whom were treated with the p64 flow-diverter stent, to assess the incidence of this phenomenon, as well as establish a correlation between it and subsequent clinical symptoms. A protocol for short-term follow-up, consisting only of a high-dose fluoroscopy image of the implant (conducted on the 14th postprocedural day) was implemented to assess the state of the implant before endothelization was to be expected. Stent deformities were seen in 58% of cases. One patient with an observed stent deformity presented with several episodes of acute contralateral 1-sided weakness of the limbs. Seventy-one percent of those patients presented with a mild/moderate unilateral headache postprocedurally. A correlation between the deformity and a subsequent narrowing of the parent vessel diameter was established on follow-ups. Notable in-stent stenosis was reported in 35% of all cases. Cases with subacute stent deformities are presented in a nonnegligible percent of flow-diversion therapies with the p64 stent. A statistically significant association between the observed deformation and subsequent in-stent stenosis was observed on follow-up.
- Open Access
- 15 June 2024
- Published by Balkan Association of Nephrology, Dialysis, Transplantation and Artificial Organs in BANTAO Journal
- Vol. 22 (1) , 18-21
A Neurosurgical Patient with Acute Renal Failure
Rhabdomyolysis is a common cause of acute renal failure. It represents a peripheral muscle damage with myoglobinuria and electrolyte disturbances with or without volume changes and renal injury. We present a 47-years-old male patient with traumatic subdural he- matoma who developed acute renal failure after two grand mal seizures. After alkalization, hydration and diuretic treatment renal failure subsided and the patient underwent successful evacuation of hematoma. We discuss the pathogenic mechanisms of development of acute renal injury in rhabdomyolysis.
- 15 June 2024
- Published by Balkan Association of Nephrology, Dialysis, Transplantation and Artificial Organs in BANTAO Journal
- Vol. 22 (1) , 18-21
Open AccessA Neurosurgical Patient with Acute Renal Failure
Rhabdomyolysis is a common cause of acute renal failure. It represents a peripheral muscle damage with myoglobinuria and electrolyte disturbances with or without volume changes and renal injury. We present a 47-years-old male patient with traumatic subdural he- matoma who developed acute renal failure after two grand mal seizures. After alkalization, hydration and diuretic treatment renal failure subsided and the patient underwent successful evacuation of hematoma. We discuss the pathogenic mechanisms of development of acute renal injury in rhabdomyolysis.
- Open Access
- 26 May 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (6) , 1148-1156
Comaneci-Assisted Coiling as a Treatment Option for Acutely Ruptured Wide Neck Cerebral Aneurysm: Case Series of 118 Patients
Background: Wide-necked cerebral aneurysms in the setting of acute subarachnoid hemorrhage (SAH) remain difficult to treat with endovascular methods despite recent progress in the neuroendovascular field. Objective: To evaluate the effectiveness and safety of the Comaneci device (Rapid Medical, Israel) in endovascular coil embolization of acutely ruptured, wide-necked sidewall, or bifurcation cerebral aneurysms. Methods: We retrospectively reviewed 45 anterior communicating artery, 24 internal carotid artery, 21 middle cerebral artery bifurcation, 15 anterior cerebral artery, and 13 posterior circulation aneurysms, which were treated using Comaneci-assisted coil embolization from August 2017 to January 2019. We evaluated procedural complications, clinical outcomes, and mid-term angiographic follow-up. Immediate and 90 d-clinical outcome and radiological follow-up were obtained in all patients. Results: Comaneci-assisted coil embolization was performed in 118 acutely ruptured aneurysms. The technique was carried out successfully in all cases. Simultaneous application of 2 separated Comaneci devices was performed in 8/118 cases (6.77%). Periprocedural thromboembolic complications related to the device were seen in 7/118 cases (5.93%) and severe vasospasm of the parent artery after manipulation of the Comaneci device occurred in 5/118 cases (4.2%). The procedural-related morbidity rate was 2.54%, and there was no procedural related mortality. Among the available survivors, angiographic follow-ups were obtained at 3 and 6 mo, and complete aneurysmal obliteration was confirmed in 81/112 (72.3%) and 75/112 (66.9%) cases, respectively. Mid-term follow-up reviewed total recanalization rate of 14.28%. Conclusion: Comaneci-assisted embolization of wide-necked intracranial aneurysms in patients presenting with acute SAH is associated with high procedural safety and adequate occlusion rates. Furthermore, dual antiplatelet therapy can be safely avoided in this patient group.
- 26 May 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (6) , 1148-1156
Open AccessComaneci-Assisted Coiling as a Treatment Option for Acutely Ruptured Wide Neck Cerebral Aneurysm: Case Series of 118 Patients
Background: Wide-necked cerebral aneurysms in the setting of acute subarachnoid hemorrhage (SAH) remain difficult to treat with endovascular methods despite recent progress in the neuroendovascular field. Objective: To evaluate the effectiveness and safety of the Comaneci device (Rapid Medical, Israel) in endovascular coil embolization of acutely ruptured, wide-necked sidewall, or bifurcation cerebral aneurysms. Methods: We retrospectively reviewed 45 anterior communicating artery, 24 internal carotid artery, 21 middle cerebral artery bifurcation, 15 anterior cerebral artery, and 13 posterior circulation aneurysms, which were treated using Comaneci-assisted coil embolization from August 2017 to January 2019. We evaluated procedural complications, clinical outcomes, and mid-term angiographic follow-up. Immediate and 90 d-clinical outcome and radiological follow-up were obtained in all patients. Results: Comaneci-assisted coil embolization was performed in 118 acutely ruptured aneurysms. The technique was carried out successfully in all cases. Simultaneous application of 2 separated Comaneci devices was performed in 8/118 cases (6.77%). Periprocedural thromboembolic complications related to the device were seen in 7/118 cases (5.93%) and severe vasospasm of the parent artery after manipulation of the Comaneci device occurred in 5/118 cases (4.2%). The procedural-related morbidity rate was 2.54%, and there was no procedural related mortality. Among the available survivors, angiographic follow-ups were obtained at 3 and 6 mo, and complete aneurysmal obliteration was confirmed in 81/112 (72.3%) and 75/112 (66.9%) cases, respectively. Mid-term follow-up reviewed total recanalization rate of 14.28%. Conclusion: Comaneci-assisted embolization of wide-necked intracranial aneurysms in patients presenting with acute SAH is associated with high procedural safety and adequate occlusion rates. Furthermore, dual antiplatelet therapy can be safely avoided in this patient group.