PBPrasun Bhattacharya

Prasun Bhattacharya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Prasun Bhattacharya has a total of 116 co-authors. Here are the top co-authors by number of shared publications:

  • Arijit Das

    Department of Transfusion Medicine, Medical College and Hospital, Kolkata, India

    4 shared publications
  • Sumita Pandey

    Department of Transfusion Medicine, Medical College and Hospital, Kolkata, India

    4 shared publications
  • Chikam Maity

    Department of Transfusion Medicine, Medical College and Hospital, Kolkata, India

    3 shared publications
  • Durba Biswas

    Department of Immunohematology and Blood Transfusion Medical College and Hospital Kolkata India

    3 shared publications
  • Krishnendu Mukherjee

    3 shared publications
  • Sandip Paul

    Centre for Health Science and Technology, JIS, Institute of Advanced Studies and Research, Kolkata, West Bengal, India

    3 shared publications

Latest Publications

  • Indication of transfusion of blood components in paediatric and neonatal patients in India: Real‐world multicentre data

    by Satyam Arora, Ruchika Goel, Ratti Ram Sharma, Sangeeta Pahuja, Nidhi Bhatnagar, Arif Vaheedu A A, Ravneet Kaur, Somnath Mukherjee, Prasun Bhattacharya, Lubna Khan, et al.

    Background and Objectives: Globally, there is high variability in paediatric transfusion practices. As per the World Health Organization (WHO), the majority of transfusions in low‐income countries are administered to children under 5 years. This study aimed to characterize the epidemiology and indications for blood component transfusions among neonatal and paediatric patients across India. Materials and Methods: A prospective longitudinal multicentre study was conducted over 6 months (April–September 2022). Standardized data sheets captured age, gender, diagnosis, transfusion indication, component type and first versus repeat transfusion status for all paediatric requests. Results: Twenty‐three medical institutions (combined 32,759 beds) participated in the study. Among 396,092 total blood component requests, 52,658 (13.2%) were for paediatric patients. Most were male (60.1%), aged 5–12 years (26.4%), and 42.7% required >1 transfusion. Red cell components were the most frequently requested (68%), followed by platelets (17.5%) and plasma (12.3%). Medical indications accounted for 67.6% requests, followed by 30.3% surgical indications. Haematology (48%), oncology (17.1%) and infections (10.5%) were the most common medical indications; however, cardiac surgeries (44.2%) and gastrointestinal surgeries (30%) were the most common surgical indications. Haemoglobinopathies (21.4%) were overall the most common indication for the transfusions reported. Conclusion: Paediatric patients accounted for over 13% of all transfusion requests, predominantly for red cells and medical indications (mainly haemoglobinopathy). This represents the first large‐scale epidemiological assessment of paediatric transfusion indications in India and establishes foundational evidence to guide understanding of blood utilization trends in children as well as indicate priority research areas for the future.


  • Open Access

    Mechanical Cold Stimulus Helps Release of PDGF from Platelet Granules: A Pilot Study

    by Biplabendu Talukder, Sunirmal Choudhury, Soumen Saha, Sambit Samanta, Rajib Chakraborty, Prasun Bhattacharya

    Background: Platelets are produced and released into the bloodstream by megakaryocytes, which reside within the bone marrow. It is pivotal in healing, hemostasis, and inducing inflammatory responses. Platelet-derived growth factor (PDGF), a critical cytokine, is released from the alpha granules of platelets and plays a significant role as a stimulator of cell division, blood vessel proliferation, and the proliferation of mesenchymal cells, including fibroblasts, osteoblasts, and vascular smooth muscle cells. PDGF also plays a role in inducing inflammation and promoting wound healing. Aims and Objectives: The study aimed to assess the PDGF concentration in PRP at 24°C and 4°C following cold stimulation. Methods: A total of 24 healthy volunteers participated in this study. A 10 mL blood sample was collected from their antecubital vein using a citrated Vacutainer in an aseptic manner. Four samples were discarded due to hemolysis, and six due to a low platelet count. Fourteen PRP samples were aliquoted into two parts for PDGF estimation at room temperature (22±2°C) and after cold stimulation at 4°C for 10 min using the sandwich ELISA method. Results: Semi-quantitative estimation of PDGF in normal (room temperature) and at 4°C shows a significant difference in OD value (P<0.001). PDGF value showed a moderate, positive correlation with the platelet number in PRP. Conclusion: The study concluded that cold exposure was strongly correlated with an increase in platelet count and PDGF concentration, which may explain the initiation of growth factor-induced rapid wound healing in cold-compressed traumatic injuries in local areas.

  • Open Access

    A Pilot Study Observing High Salivary Non-Secretor (se/se) Prevalence in Breast and Ovarian Cancers in Kolkata

    by Adrija Das Biswas, Swarnabindu Banerjee, Prasun Bhattacharya

    Background Breast and ovarian cancers remain major causes of illness and death in women. Secretor status determined by fucosyltransferase 2 (FUT2) gene controls the presence of ABO antigens in all bodily fluids except CSF, and prior studies suggest non-secretor status may be associated with cancer risk. Data on secretor prevalence in breast and ovarian cancers are limited. Methods We performed a pilot case–control study at a government medical college in Kolkata between January and June 2024. The study included 74 women: 37 patients with newly diagnosed breast (n = 23) or ovarian (n = 14) cancer and 37 healthy female blood donors. Unstimulated saliva was collected and tested for secretor status using a hemagglutination inhibition assay. Associations were tested with the chi-square test. Results Among healthy controls, 78% were secretors and 22% were non-secretors. In contrast, 81% of cancer patients were non-secretors and 19% were secretors. By cancer type, non-secretor prevalence was 82.6% in breast cancer and 78.5% in ovarian cancer. The association between non-secretor status and cancer was statistically significant (p < 0.0001). Conclusions In this pilot study, salivary non-secretor status was much more common in women with breast or ovarian cancer than in healthy controls. The findings support larger, population-level and genetic studies to confirm whether FUT2 non-secretor status could serve as a simple, low-cost marker to identify the population at risk. Limitations include small sample size and absence of FUT2 genotyping.

  • An Evaluation of an Absorption Spectroscopy Based Non-invasive Technology (EzeCheck) Versus the Gold Standard Hematology Analyzer for Hemoglobin Estimation

    by Sumita Pandey, Chikam Maity, Biplabendu Talukdar, Sayantan Saha, Arijit Das, Puspak Das, Piyali Dutta, Angela Das, Suchismita Paul, Prasun Bhattacharya

    Anemia affects 1.62 billion people globally, with a high prevalence in vulnerable groups, including 67.1% of children and 59.1% of women in India. Traditional anemia screening methods are invasive, costly, and impractical in remote areas. This study aims to evaluate the EzeCheck non-invasive device for estimating hemoglobin levels, comparing its efficacy with conventional hematology analyzers. The goal is to provide a more accessible and efficient solution for anemia screening, particularly in resourcelimited settings. This hospital-based cross-sectional study was conducted at Medical College and Hospital, Kolkata, from June to November 2024, with ethical approval. The study included patients and healthy voluntary donors from the Transfusion Medicine clinic, Blood Centre, and blood donation camps, excluding individuals with skin thickening, corns, or nail cosmetics. The study was double-blinded, with consent obtained from participants or guardians for children aged 6–12 years. Hemoglobin levels were categorized into six groups based on severity. Data were analyzed using SPSS, with Cohen’s Kappa assessing agreement between the Hematology Analyzer and EzeCheck, and Pearson correlation measuring method reliability. A total of 1125 participants were included, comprising 788 males and 337 females. The study showed substantial agreement between the EzeCheck and Hematology Analyzer. The Pearson correlation of 0.961 indicated a strong positive correlation in hemoglobin measurements. EzeCheck’s performance metrics included 93.54% sensitivity, 86.67% specificity, 83.93% positive predictive value, and 94.75% negative predictive value, with an overall accuracy of 89.60%, confirming its reliability and effectiveness in anemia screening. EzeCheck demonstrated reliable test results in both patients and healthy volunteers, making it an effective tool for patient screening and voluntary blood donation camps, particularly in resource-limited settings.

  • Role of direct antiglobulin test in anemia under evaluation: Its prevalence, laboratory workup, and significance in further patient management—A study from eastern India

    by Sumita Pandey, Chikam Maity, Sambit K. Samanta, Arunansu Talukdar, Arijit Das, Sandip Paul, Prasun Bhattacharya, Pushpak Das

    Introduction and Aims: The direct antiglobulin test (DAT) is an important diagnostic tool for immune hemolytic anemia (IHA). The present study was primarily aimed to identify the prevalence of DAT positivity in anemia patients along with its specificity . A three months follow up of the DAT positive patients were performed for the response during course of illness in terms of transfusion requirement, hemoglobin level, persistence of DAT. Materials and Methods: This cross sectional study was performed at a government medical college on symptomatic anemia patients. At initial evaluation, complete blood count (CBC), blood grouping and DAT were performed in the EDTA blood. DAT positive blood samples were analyzed for their immunoglobulin specificity, auto or alloantibody type. Acid elution and red cell phenotyping were performed wherever applicable.Their clinical presentation, hematological and biochemical parameters of hemolysis were evaluated. Statistical analysis was performed on the results on SPSS (Version 23.0;.USA) and Graph pad Prism version 9. P value <0.05 was considered significant. Results: DAT was present in 64 out of 501 patients with male female ratio 1: 4. Warm AIHA (WAIHA) was 93.7% with secondary WAIHA 60%. IgG was associated in 86% DAT positive samples, Only C3d was 14%. All the 4 cold AIHA (6.3%) had a higher antibody titre and thermal amplitude. DAT strength was directly proportional to the degree of hemolysis. During 3 months follow up , persistence of DAT and blood transfusion requirement was more in secondary WAIHA . Hemoglobin increment was more in primary WAIHA (75%). Conclusion: DAT played a significant role in the diagnosis as well as evaluation of AIHA.

  • Open Access

    Prevalence of Cytomegalovirus Infections in Blood Donors and the Newborn versus Utility of Leukocyte-reduced Blood Transfusion in the Premature Newborn: An Observation from Eastern India

    by Arijit Das, Dinesh Munian, Chikam Maity, Sumita Pandey, Sandip Paul, Prasun Bhattacharya

    Purpose and Objectives: Leukocyte-reduced blood components prevent the transmission of cytomegalovirus (CMV) infection; however, provision of universal leukoreduced blood involves a huge resource constraint to developing countries. The present study aimed to identify the seroprevalence of CMV among voluntary blood donors and newborns who were transfused with nonleukoreduced blood in the recent past (control). With the availability of leukoreduced blood, the pre- and posttransfusion CMV serology was analyzed in the newborn (cohort) who had received entirely leukoreduced blood to understand its utility. Methods: Eight hundred and fifty-two healthy blood donors and 40 newborns (control) who received nonleukoreduced blood in the recent past were observed for the seroprevalence of CMV. In the other arm, 45 newborns (premature) were transfused with leukoreduced blood and observed for CMV seroprevalence during both pre- and posttransfusion periods. To identify the evidence of recent infection in these population, CMV immunoglobulin G (IgG) avidity was performed in a proportion of the participants in all the groups. Quality control of the leukoreduced blood components was also checked as per standards. Results: The overall seroprevalence of CMV in blood donors, posttransfused newborns (control), and the cohort group was high. In the blood donors, a limited number of CMV IgG avidity tests showed a high infectivity rate (85.19%). A similar result was also observed in the newborn population in both the groups for recent CMV infections. Conclusion: The present study showed a high prevalence of CMV infections in blood donors and newborns. The leukoreduced blood transfusion might be effective for preventing other serious adverse outcomes except CMV.


  • Open Access

    Clinical Trial Subgroup Analyses to Investigate Clinical and Immunological Outcomes of Convalescent Plasma Therapy in Severe COVID-19

    by Deblina Raychaudhuri, Purbita Bandopadhyay, Ranit D’rOzario, Jafar Sarif, Yogiraj Ray, Shekhar Ranjan Paul, Praveen Singh, Kausik Chaudhuri, Ritwik Bhaduri, Rajesh Pandey, et al.


  • A prospective study on COVID‐19 convalescent plasma donor (CCP) recruitment strategies in a resource constrained blood centre

    by Durba Biswas, Chikam Maiti, Biplabendu Talukder, Azharuddin, Sayantan Saha, Sumita Pandey, Arijit Das, Setu Das Adhikari, Yogiraj Ray, Biswanath S. Sarkar, et al.

    Background and objectives The Covid‐19 pandemic has spread across 87 million people with more than 1.8 million deaths in the world. As there is no definite treatment modality, the use of convalescent plasma has become increasingly popular worldwide. This study aimed to identify an appropriate strategy of donor recruitment and to evaluate the appropriateness of pre‐set plasma donation guidelines. Material and methods In this prospective study conducted from May ‐ September 2020, the donors were recruited under the following two circumstances: Group I, patients in the post‐Covid‐19 follow‐up in the clinic, and Group II, patients recovered from Covid‐19 recruited through mass and electronic media. A pre‐set donor selection criteria and laboratory investigation was designed according to national and international guidelines. Approximately 500 ml of Covid‐19 convalescent plasma (CCP) was collected from recovered individuals in each group by two different cell separators. The overall donor’s attendance rate, deferral rate, adverse events and donor compliance was analyzed and compared between the 2 groups. Results There was significant difference in attendance in relation to registration between the groups (p <0.0001). Donor deferral was significantly higher in group I compared to group II. The single most frequent cause of donor deferral was low antibody index (p =0.0001). The total donor adverse event rate in CCP donation was significantly lower compared to routine plateletpheresis procedures. The donor’s compliance to blood centre’s protocol was satisfactory in both the groups. Conclusion Recruitment of patients in the post–covid‐19 follow‐up in the clinic was more effective than the general recruitment through mass and electronic media for convalescence plasma donation in a resource constrained blood centre.